Mean Well DRP-240-24 240w single output industrial din rail power supply Datasheet

240W Single Output Industrial DIN RAIL Power Supply
DRP-240
series
Features :
Universal AC input / Full range
Built in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508(industrial control equipment)approved
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
3 years warranty
SPECIFICATION
MODEL
OUTPUT
DRP-240-24
DRP-240-48
DC VOLTAGE
24V
48V
RATED CURRENT
10A
5A
CURRENT RANGE
0 ~ 10A
0 ~ 5A
RATED POWER
240W
240W
RIPPLE & NOISE (max.) Note.2 80mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
48 ~ 53V
1.0%
24 ~ 28V
VOLTAGE TOLERANCE Note.3 1.0%
LINE REGULATION
0.5%
LOAD REGULATION
1.0%
24ms/230VAC
HOLD UP TIME (Typ.)
INPUT
Note.5 85 ~ 264VAC
47 ~ 63Hz
0.96/230VAC
84%
0.99/115VAC at full load
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
2.8A/115VAC
1.4A/230VAC
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
(Note 4)
COLD START 27A/115VAC
45A/230VAC
<3.5mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
54 ~ 60V
30 ~ 36V
Protection type : Shut down o/p voltage, re-power on to recover
100
5 (TSW1)detect on heat sink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-10 ~ +70
(Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
UL508, UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55011,EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
DIMENSION
PACKING
NOTE
85%
ISOLATION RESISTANCE
EMS IMMUNITY
MTBF
OTHERS
24ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
OVERLOAD
EMC
800ms, 40ms/115VAC at full load
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
LEAKAGE CURRENT
SAFETY &
1.0%
800ms, 40ms/230VAC
SETUP, RISE TIME
VOLTAGE RANGE
0.5%
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
105.5Khrs min. MIL-HDBK-217F (25
125.5*125.2*100mm (W*H*D)
1.2Kg; 12pcs/15.5Kg/1.29CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:DRP-240-SPEC 2008-04-07
DRP-240
240W Single Output Industrial DIN RAIL Power Supply
Mechanical Specification
Case No. 922A
series
Unit:mm
125.5
100
125.2
TB1
LED
3 2 1
TB2
4 3 2 1
Terminal Pin Number Assignment (TB1)
+V ADJ.
Pin No.
1
2
3
35
ADMISSIBLE DIN-RAIL: TS35/7.5 OR TS35/15
Assignment
FG
AC/N
AC/L
Terminal Pin Number Assignment (TB2)
Pin No.
1,2
3,4
Assignment
DC OUTPUT +V
DC OUTPUT -V
Block Diagram
fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
PFC
CIRCUIT
RECTIFIERS
&
FILTER
POWER
SWITCHING
FG
O.L.P.
+V
-V
CONSTANT
CURRENT
LIMITING &
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
O.T.P.
Derating Curve
Output derating VS input voltage
Ta=25
100
100
230VAC
90
80
80
70
110VAC
LOAD (%)
LOAD (%)
60
40
20
60
50
40
-10
0
10
20
30
40
50 55 60
AMBIENT TEMPERATURE ( )
70 (VERTICAL)
Vin: -- 230VAC
110VAC
85
100
110
135
155
230
264
INPUT VOLTAGE (V) 60Hz
File Name:DRP-240-SPEC 2008-04-07