EMI Suppression Capacitors B 81 130 X2 / 275 Vac X2 capacitors with very small dimensions Rated ac voltage 275 V, 50/60 Hz Construction ■ ■ ■ ■ Dielectric: polypropylene (MKP) Plastic case (UL 94 V-0) Epoxy resin sealing, flame-retardant Impregnated Features ■ Very small dimensions ■ Self-healing properties Lead spacing ± 0,4 Terminals ■ Parallel wire leads, tinned ■ Two standard lead lengths available: 6 mm und 26 mm Other lead lengths available upon request. Lead diameter Lead length l1 ∅d (mm) (mm) 10 mm 0,6 6–1 — ≥ 15 mm 0,8 6–1 26 ± 2 Lead spacing = 10 mm Lead spacing ≥ 15 mm (22 nF ... 1,0 µF) Marking Manufacturer’s logo and lot number date code, rated capacitance (coded), capacitance tolerance (code letter), rated ac voltage, type number, interference suppression sub-class (X2), style (MKP), climatic category, awarded marks of conformity. AAAAA C1103 XX-10n M 275V~ AAAAA C1104 XX-µ1 M 275V~ B81130 X2 MKP/SH 40/100/21/C B81130 X2 MKP/SH 40/100/21/C V D E V D E IEC 384-14(2) KMK0570-T AAAAA C1155 XX-1µ5 M 275V~ B81130 X2 MKP/SH 40/100/21/C Bulk (untaped) Taped (Ammo pack or reel) For notes on taping, refer to chapter “Taping and packing”, page 274. V D E IEC 384-14(2) 1) 250 V~ KMK0699-I Marks of conformity Marks of conformity 250 V~ KMK0571-2 Lead spacing = 27,5 mm (1,5 and 2,2 µF) Delivery mode 250 V~ Standards Certificate EN 132400 / IEC 384-14, 2nd edition UL 1414 (VR = 250 Vac) Approved by UL according to CSA C22.2 No. 0; 1 (V R = 250 Vac) 18643-4670-1010/A1G E97863/97NK11940A E97863/97NK11940A 1) Not for 1,5 and 2,2 µF 231 12/00 X2 B 81 130 275 Vac Ordering codes and packing units Maximum dimensions b×h×l (mm) Ordering code1) Packing units (pcs) Ammo Reel Untaped pack Lead length 6 mm 26 mm Lead spacing ± 0,4 mm CR 10 10 nF 15 nF 22 nF 33 nF 33 nF 47 nF 4,0 × 9,0 × 13,0 4,0 × 9,0 × 13,0 5,0 × 11,0 × 13,0 5,0 × 11,0 × 13,0 6,0 × 12,0 × 13,0 6,0 × 12,0 × 13,0 B81130-C1103-+*** 1000 B81130-C1153-+*** 1000 B81130-C1223-+*** 830 B81130-C1333-M*** 830 B81130-A1333-+*** 680 B81130-C1473-+*** 680 1700 1700 1300 1300 1100 1100 1000 1000 1000 1000 1000 1000 — — — — — — 15 22 nF 33 nF 47 nF 68 nF 0,10 µF 0,10 µF 0,15 µF 0,22 µF 5,0 × 10,5 × 18,0 5,0 × 10,5 × 18,0 5,0 × 10,5 × 18,0 6,0 × 11,0 × 18,0 6,0 × 12,0 × 18,0 7,0 × 12,5 × 18,0 8,5 × 14,5 × 18,0 9,0 × 17,5 × 18,0 B81130-B1223-+*** 1170 B81130-B1333-+*** 1170 B81130-B1473-+*** 1170 B81130-C1683-+*** 960 B81130-C1104-M*** 960 B81130-A1104-+*** 830 B81130-C1154-+*** 680 B81130-C1224-+*** 640 1300 1300 1300 1100 1100 900 700 700 1000 1000 1000 1000 1000 1000 500 500 1000 1000 1000 1000 1000 800 500 500 22,5 0,15 µF 6,0 × 15,0 × 26,5 0,22 µF 7,0 × 16,0 × 26,5 0,33 µF 8,5 × 16,5 × 26,5 0,47 µF 10,5 × 16,5 × 26,5 0,47 µF 10,5 × 18,5 × 26,5 0,68 µF 11,0 × 20,5 × 26,5 B81130-B1154-+*** B81130-B1224-+*** B81130-C1334-+*** B81130-C1474-M*** B81130-A1474-+*** B81130-C1684-M*** 700 600 500 400 400 350 720 630 510 540 540 510 500 500 450 350 300 300 27,5 0,47 µF 0,68 µF 1,0 µF 1,0 µF 1,5 µF 1,5 µF 2,2 µF 2,2 µF B81130-B1474-+*** B81130-B1684-+*** B81130-C1105-M*** B81130-A1105-+*** B81130-C1155-M*** B81130-A1155-+*** B81130-C1225-M*** B81130-A1225-+*** 350 350 300 250 — — — — 320 320 280 260 240 200 200 180 200 200 200 150 150 100 100 100 11,0 × 21,0 × 31,5 11,0 × 21,0 × 31,5 12,5 × 21,5 × 31,5 13,5 × 23,0 × 31,5 15,0 × 24,5 × 31,5 18,0 × 27,5 × 31,5 18,0 × 27,5 × 31,5 19,0 × 30,0 × 31,5 680 580 480 390 390 370 — — — — — — — — Capacitance tolerance: ± 20 % =ˆ M, ± 10 % =ˆ K (closer tolerances upon request) 1) Replace the + by the code letter for the required capacitance tolerance. Replace the *** by the code number for the required lead length or packing. 000 = lead length 6 mm (untaped) 026 = lead length 26 mm (untaped) 289 = taped, Ammo pack 189 = taped, reel 232 12/00 B 81 130 X2 275 Vac Technical data Climatic category in accordance with IEC 60068-1 40/100/21 Lower category temperature Tmin Upper category temperature Tmax − 40 °C + 100 °C Passive flammability category in accordance with IEC 40 (CO) 752 C Damp heat test 21 days/40 °C/93 % relative humidity Limit values after damp heat test Capacitance change |∆C/C| Dissipation factor change ∆ tan δ Insulation resistance Ris or time constant τ = C R ⋅ Ris Permissible continuous ac voltage 275 V (50/60 Hz) Permissible continuous dc voltage 560 V DC test voltage 2121 V, 2 s Dissipation factor tan δ (in 10−3) at 20 °C (upper limit values) Insulation resistance R is or time constant τ = CR ⋅ R is at 20 °C, rel. humidity ≤ 65 % (minimum as-delivered values) ≤3% ≤ 0,5 ⋅ 10−3 (at 1 kHz) ≤ 1,0 ⋅ 10−3 (at 10 kHz) ≥ 50 % of minimum as-delivered values at CR ≤ 0,1 µF 1 kHz 1,0 100 kHz 5 CR ≤ 0,33 µF 100 GΩ 0,1 µF < CR ≤ 1 µF C R > 1 µF 1,0 10 C R > 0,33 µF 30 000 s Impedance Z versus frequency f (typical values) 233 12/00 1,0 13 X2 B 81 130 275 Vac Pulse handling capability Maximum permissible voltage change per unit of time for non-sinusoidal voltages (pulse, sawtooth). VR 275 Vac Max. rate of voltage rise V pp/τ in V/µs (for V pp = V̂R) Lead spacing 10 mm 15 mm 22,5 mm 27,5 mm 290 110 50 30 For V pp < V̂R, the permissible voltage rise rate V pp/τ may be multiplied by the factor V̂R/V pp. Also refer to the calculation example in chapter “General technical information”, page 302. VR 275 Vac Pulse characteristic k 0 in V2/µs (for V pp ≤ V̂R) Lead spacing 10 mm 15 mm 22,5 mm 27,5 mm 220 000 80 000 35 000 21 000 234 12/00 Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1