Systemsensor H12/24K Selectable output strobe and horn strobe Datasheet

A u d i b l e / V i s i b l e
N o t i f i c a t i o n
Selectable Output Strobe
and Horn/Strobes
Models Available
Strobes
Red
S1224MC
S1224MCP
S1224MCK
S1224MCSP
Horn/Strobes
Red
P1224MC
P1224MCP
P1224MCK
P1224MCSP
Horns
Red
H12/24
H12/24K
P1224MC Horn/Strobe
White
S1224MCW
S1224MCPW
White
P1224MCW
P1224MCPW
White
H12/24W
S1224MC Strobe
Product Overview
Operates on either 12V or 24V
Widest range of candela options:
12V: 15 and 15/75 candela
24V: 15, 15/75, 30, 75, 110 candela
Easy candela selection
Lower current draw
Easy DIP switch selection for horn
options
Easy mounting with QuickClick™
Synchronizable with MDL
Sync•Circuit™ module
Meets UL1971, NFPA72, and ADA
signaling requirements
All strobe and horn/strobe models incorporate
a new patented voltage booster design that has
a more consistent flash bulb voltage over the
range of candela selections. The benefit to the
customer is a high quality strobe device.
7125-1209:222
7135-1209:223
3014150
S5512
S4011
122-02-E
126-02-E
SpectrAlert® Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced features that include the widest range of candela options available and the capability to
recognize and self-adjust for either 12 or 24 volt operation. With an overall feature
set that combines performance, installation ease, flexibility, and a consistent,
aesthetically pleasing appearance, the SpectrAlert Selectable Output devices
provide both the innovation and efficiency synonymous with the SpectrAlert name.
Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes
offer key performance features long associated with the SpectrAlert name. The selectable candela strobes and horn/strobes offer average current draws that are not only
lower than conventional fixed-candela SpectrAlert products, but also lower than similar
selectable candela products. By consuming less current, the ability to connect even more
devices per loop is possible, resulting in a lower installed cost.
Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the
same installation-friendly features synonymous with the SpectrAlert name, such as the
option of 2- and 4-wire operation; the ability to use standard size backboxes with no
encroachment into the box; and universal mounting incorporating the labor-saving
QuickClick™ feature. Such labor-savings features make wire connections simple and fast,
further reducing installed cost.
Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest
range of candela options. In addition, the selectable output strobes and horn/strobes
can operate on either 12V or 24V, with no setting required; the device recognizes and
self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options
continue to be available, in either an Electromechanical or 3kHz pattern.
Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate
the same stylish, low profile design of the conventional SpectrAlert products, for a consistent and aesthetically pleasing appearance across the entire product line.
Engineering Specifications
General
SpectrAlert horns, strobes and horn/strobes shall be capable of
mounting to a standard 4˝ × 4˝ × 11/ 2˝ back box or a single gang
2˝ × 4˝ × 17/ 8˝ back box using the universal mounting plate
included with each SpectrAlert product. Also, SpectrAlert products, when used in conjunction with the accessory Sync•Circuit
Module, shall be powered from a non-coded power supply
and shall operate on 12 or 24 volts. 12 volt rated devices shall
have an operating voltage range of 9–17.5 volts. 24-volt rated
devices shall have an operating voltage range or 17–33 volts.
SpectrAlert products shall have an operating temperature of
32° to 120°F and operate from a regulated DC or full wave
rectified, unfiltered power supply.
Strobe
Strobe shall be a System Sensor SpectrAlert Model _______
listed to UL 1971 and be approved for fire protective service. The
strobe shall be wired as a primary signaling notification appliance
and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the
strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.
Horn/Strobe Combination
Horn/Strobe shall be a System Sensor SpectrAlert Model
_______ listed to UL 1971 and UL 464 and shall be approved for
fire protective service. Horn/strobe shall be wired as a primary
signaling notification appliance and comply with the Americans
with Disabilities Act requirements for visible signaling appliances,
flashing at 1Hz over the strobe’s entire operating voltage range.
The strobe light shall consist of a xenon flash tube and associated
lens/reflector system. The horn shall have two tone options, two
audibility options (at 24 volts) and the option to switch between
a temporal 3 pattern and a non-temporal continuous pattern.
Strobes shall be powered independently of the sounder with the
removal of factory installed jumper wires. The horn on horn/
strobe models shall operate on a coded or non-coded power supply (the strobe must be powered continuously).
Synchronization Module
Module shall be a System Sensor Sync•Circuit _______ listed
to UL 464 and shall be approved for fire protective service. The
module shall synchronize SpectrAlert strobes at 1Hz and horns
at temporal 3. Also, the module shall silence the horns on horn/
strobe models, while operating the strobes, over a single pair of
wires. The module shall be capable of mounting to a 411/16˝ ×
411/16˝ × 21/8˝ back box and shall control two Style Y (class B) or
one Style Z (class A) circuit. Module shall be capable of multiple
zone synchronization by daisy chaining multiple modules together
and re-synchronizing each other along the chain. The module
shall not operate on a coded power supply.
Specifications
Walk Test
SpectrAlert horn/strobe and horn only
work on “walk tests” with time durations of 4 seconds or greater
Input Terminals
12 to 18 AWG
Dimensions
Strobe and horn/strobe with universal
plate
5˝ × 5 5/8˝ × 2 15/16˝
Strobe and horn/strobe with small
footprint plate
3 3/8˝ × 5 5/8˝ × 2 5/16˝
Weight, horn only
7.2 oz.
Voltages
12 or 24VDC and FWR1 unfiltered
Weight, strobe and horn/strobe
8.8 oz.
Operating voltage range
12V: 8–17.5V; 24V: 16–33V
Mounting
4˝ × 4˝ × 1 1/2˝ or 2˝ × 4˝ × 1 7/8˝
standard boxes
Operating voltage range (with
Sync•Circuit module, MDL)2
12V: 9–17.5V; 24V: 17–33V
Operating Temperature (Indoor)
32°F to 120°F (0°C to 49°C)
U.S. Patent Numbers
5,593,569
5,914,665
6,049,446
Maximum humidity (Indoor)
95% as tested per UL464
Horn with universal mounting plate
5˝ × 5 5/8˝ × 1 5/16˝
Outdoor (K Series) Operating Temperature
–40°F to 151°F
(–40°C to 66°C)
Horn without mounting plate
2 15/16˝ × 5 5/16˝ × 1 5/16˝
Outdoor rating
NEMA 3R (per UL 50)
Notes:
1. Full Wave Rectified (FWR) voltage is a non-regulated, time-var ying power source that is used on some power supply and panel outputs.
2. The MDL causes a one-volt voltage drop in the notification appliance circuit.
Table 1-A: SpectrAlert Strobe UL Max. Current Draw
FWR Operating
Current–Strobe
(mA RMS)
8-17.5V
16-33V
112
64
135
74
93
158
208
DC Operating
Current–Strobe
(mA RMS)
8-17.5V
16-33V
127
59
127
69
90
160
209
Explanation of Published Voltage, Current, and SPL
Specifications
In May 2004 Underwriters Laboratories changed standard
UL 1971 to require that operating current measuremments
are made using RMS (root mean square) instead of peak
or average values. RMS measurements more accurately
predict the power consumption of a device since they take
into account the entire current draw profile including surge,
repetitive surge, and peak values. The published RMS current is the maximum operating current of that device within
its operating voltage range. This current maximum may or
Table 1-B: Horn UL Max. Current Draw Measurements (mA RMS) may not occur at the endpoints of the voltage range.
Candela
Setting
15
15/75
30
75
110
DC
Selectable Horn Tones
Temporal
NonTemporal
FWR
8-17.5V
16-33V
8-17.5V
16-33V
Low
Volume
Electromechanical
15
23
13
23
3000 Hz Interrupted
15
33
13
23
High
Volume
Electromechanical
36
53
20
44
3000 Hz Interrupted
43
57
21
40
Low
Volume
Electromechanical
16
37
19
29
3000 Hz Interrupted
16
32
18
33
High
Volume
Electromechanical
38
49
46
49
3000 Hz Interrupted
44
56
42
58
Table 1-C: 12VDC Horn/Strobe UL Max. Current Draw
Measurements (mA RMS)
1. Current draw for strobe-only products is shown in Table 1-A.
High Volume
Candela
Setting
Electromechanical
3000 Hz
Electromechanical
3000 Hz
15
111
111
112
112
15/75
127
127
126
129
15
113
112
114
115
15/75
128
128
130
134
Non-Temporal
2. Current draw for horn-only products is shown in Table 1-B.
3. 12VDC 2-wire horn/strobe current is shown in Table 1-C.
4. 24VDC 2-wire horn/strobe current draw is shown in Table
1-D.
5. Current draw for other horn/strobe power supplies can be
calculated by adding the strobe current in Table 1-A to the
horn current in Table 1-B from the chosen settings.
SpectrAlert Strobe Candela Selections
Table 1-D: 24VDC Horn/Strobe UL Max. Current Draw
Measurements (mA RMS)
For strobe candela selection, adjust slide switch located on the
rear of the product while watching the viewing window on the
side of the reflector.
Temporal
Low Volume
During May 2004, UL also changed the way they list the
voltage range of a device. All 12V products will be listed
between 8 – 17.5V and all 24V products will be listed
between 16 – 33V. Those devices are considered “regulated”. Any product that does not operate within these ranges
will be listed as a “special application” with its operating
voltage specified on the device.
Notes
Temporal
Low Volume
Similarly, UL tests the audibility of devices in accordance
with UL 464 by measuring them across the operating voltage range to determine the minimum sound pressure level
produced at any particular setting.
High Volume
Candela
Setting
Electromechanical
3000 Hz
Electromechanical
3000 Hz
15
71
70
73
75
15/75
86
85
87
88
30
99
98
100
100
75
166
166
167
170
110
209
209
210
213
Permissible Candela Settings
Candela
Setting
Non-Temporal
15
74
74
79
82
15/75
86
88
93
96
30
101
101
107
110
75
167
167
173
176
110
213
213
218
222
Viewing Window
A0133-00
Operating Voltage
12V
24V
15
OK
OK
15/75
OK
OK
30
OK
75
OK
110
OK
SpectrAlert Horn Sound Measurements (dBA)
Selectable Horn Tones
Temporal
NonTemporal
Typical weatherproof mounting with universal plate
8-17.5V
16-33V
Low
Volume
Electromechanical
67
75
3000 Hz Interrupted
68
75
High
Volume
Electromechanical
71
80
3000 Hz Interrupted
72
81
Low
Volume
Electromechanical
71
79
3000 Hz Interrupted
72
79
High
Volume
Electromechanical
76
84
3000 Hz Interrupted
77
86
WBB
Gasket
Conduit
Entrance
DIP Switch Operation on P1224MC
OFF
ON
Low
Factory
Default
Plate
#8-36 x 1/2˝ Flat Head
Screw (4 total)
Slot
Paper Liner
For Plate
Gasket
Locking Rib
A0135-02
DIP Switch
High
Temporal
Non-Temporal
Electromech.
3000Hz
Base (rear)
A0110-00
SpectrAlert Ordering Information
Model
Description
Model
Description
P1224MC
Selectable Output Horn/Strobe, 12/24 volt, red
H12/24
Horn, 12/24 volt, red
P1224MCW
Selectable Output Horn/Strobe, 12/24 volt, white
H12/24W
Horn, 12/24 volt, white
P1224MCP
Selectable Output Horn/Strobe, 12/24 volt, red,
plain housing
H12/24K
Horn, 12/24 volt, red, outdoor
P1224MCPW
Selectable Output Horn/Strobe, 12/24 volt,
white, plain housing
Accessories
MDL
Sync•Circuit Module, red
MDLW
Sync•Circuit Module, white
P1224MCK
Selectable Output Horn/Strobe, 12/24 volt, red,
outdoor
MDLWA
Sync•Circuit Module, white, Canadian model
P1224MCSP
Selectable Output Horn/Strobe, 12/24 volt, red,
“FUEGO” housing
S-MP
Small Footprint Mounting Plate, red, for singlegang back box
S1224MC
Selectable Output Strobe, 12/24 volt, red
S-MPW
S1224MCW
Selectable Output Strobe, 12/24 volt, white
Small Footprint Mounting Plate, white, for singlegang back box
S1224MCP
Selectable Output Strobe, 12/24 volt, red, plain
housing
BBS
Sur face Mount Back Box Skir t, red
BBSW
Sur face Mount Back Box Skir t, white
S1224MCPW
Selectable Output Strobe, 12/24 volt, white,
plain housing
D-MP
Universal Mounting Plate (replacement), red
D-MPW
Universal Mounting Plate (replacement), white
WBB
Weatherproof Back Box
S1224MCK
Selectable Output Strobe, 12/24 volt, red,
outdoor
S1224MCSP
Selectable Output Strobe, 12/24 volt, red,
“FUEGO” housing
Notes
All of these SpectrAlert products are designed for wall mount only. All outdoor models must use weatherproof back box model WBB. Installation of
less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of
the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/
strobes are recommended for 20′ × 20′ rooms or less.
System Sensor Sales and Service
System Sensor Headquarters
3825 Ohio Avenue
St. Charles, IL 60174
Ph: 800/SENSOR2
Fx: 630/377-6495
www.systemsensor.com
System Sensor Canada
Ph: 905.812.0767
Fx: 905.812.0771
System Sensor in China
Ph: 86.29.8832.0119
Fx: 86.29.8832.5119
System Sensor – Far East
Ph: 85.22.191.9003
Fx: 85.22.736.6580
System Sensor – India
Ph: 91.124.237.1770 x.2700
Fx: 91.124.237.3118
System Sensor Europe
Ph: 44.1403.276500
Fx: 44.1403.276501
System Sensor in Singapore
Ph: 65.6273.2230
Fx: 65.6273.2610
System Sensor – Australia
Ph: 613.54.281.142
Fx: 613.54.281.172
System Sensor – Russia
Ph: 70.95.937.7982
Fx: 70.95.937.7983
­© 2005 System Sensor. The company reserves the right to change product specifications without notice.
A05-0325-006•9/05•#1526
Similar pages