General C8024 Rg 59/u type coaxial & 2/c 18 awg siamese cctv - cable Datasheet

PRODUCT DATA SHEET
Part Number:
C8024
Revision Level:
04
Date:
1C 22 SBC FMPE OA BS, 2C 18 AWG BC PVC,
SIAMESE FR-PVC JKT
05/14/2012
RG 59/U Type Coaxial & 2/C 18 AWG
Siamese CCTV - Cable
A.
CONSTRUCTION A
DIAMETERS
1)
CONDUCTOR:
#22 AWG 7/30 Bare Copper
0.030” nom.
2)
3)
B.
1)
2)
INSULATION:
BRAID SHIELD:
CONSTRUCTION B
CONDUCTOR:
INSULATION:
0.057” Wall Foamed Polyethylene
Bare Copper Braid (95% Coverage)
0.144” nom.
0.171” nom.
#18 AWG 7/.0152 Bare Copper
0.010” Wall Polyvinyl Chloride
0.046” nom.
0.066” nom.
3)
CABLE:
2 conductors (Black, Red)
0.132” nom.
C.
1)
FINAL CABLE
JACKET:
0.032” Wall FR-Polyvinyl Chloride
2)
PRINT LEGEND:
D.
INDUSTRY APPROVALS
Major dim:
0.460” +/- 0.024”
Minor dim:
0.242” +/- 0.012”
CAROL (R) -- C8024 -- RG 59/U TYPE COAX – 1C 22 AWG + 2C 18 AWG
CL2 (ETL) OR CM c(ETL)us 75C 3084997 — MADE IN USA (MFG CODE;
MM/YY & TRU-MARK SEQ. FT. MKGS)
UL Standards 13
National Electric Code
Type CL2 (ETL)
Article 725
UL & CSA Standards 444
National Electric Code
EU 2002/95/EC
Type CM c(ETL)us
Article 800
RoHS Compliant
E.
ELECTRICAL PROPERTIES
1)
2)
3)
4)
5)
6)
7)
8)
9)
TEMPERATURE:
SUGGESTED WORKING VOLTAGE (Vrms):
CONDUCTOR D.C. RESISTANCE A:
CONDUCTOR D.C. RESISTANCE B:
SHIELD RESISTANCE A:
MUTUAL CAPACITANCE A:
CAPACITANCE B: (Conductor – Conductor)
CHARACTERISTIC IMPEDANCE A:
Attenuation:
-20C to +75C
300V MAX
14.8 Ohms/1000 ft. nom. @ 20 C
6.65 Ohms/1000 ft. nom. @ 20 C
3.00 Ohms/1000 ft. nom. @ 20 C
17 pF/ft. @ 1 kHz nom.
18.0 pF/ft. @ 1kHz nom.
77 Ohms @ 1 MHz nom.
FREQ. (MHz)
1
10
50
100
200
500
1000
dB/100 ft.
0.26
0.91
2.09
3.00
4.33
7.03
10.64
Note: Data are subject to change without notice. Contact your Customer Service representative for latest information.
Rev. 1: –revise diameter from .146 to .144, shld res from 2.0 to 3.0 , DCR; and correct cond strand from 18 16/30 to 18 7/.0152 ,
correct cap from 45 to 35 and imp from 43 ohms to 65 ohms and remove cap-ground on B // GT ( February 25, 2010)
Rev. 2: remove CATV from print legend - GT – 3/16/2010
Rev. 3: correct cap on (B) from 30 to 18 based on actual test data (17.33) , remove Imp ( B); add drawing , remove jkt color – GT (
04/21/2010)
Rev. 4: revise spec from UL to ETL, Remove AWM GT/ 5/14/12
Similar pages