Kemet C430C105J1R5TA7200 Aximax, 400 series, conformally coated, x7r dielectric, 25 - 250 vdc (commercial grade) Datasheet

Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated,
X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Overview
KEMET’s Aximax conformally coated axial leaded ceramic
capacitors in X7R dielectric feature a 125°C maximum
operating temperature. The Electronics Industries Alliance
(EIA) characterizes X7R dielectric as a Class II "temperature
stable" material. Components of this classification are fixed,
ceramic dielectric capacitors suited for bypass and decoupling
applications or for frequency discriminating circuits where Q
and stability of capacitance characteristics are not critical. X7R
exhibits a predictable change in capacitance with respect to time
and voltage and boasts a minimal change in capacitance with
reference to ambient temperature. Capacitance change is limited
to ±15% from −55°C to +125°C.
These devices meets the flame test requirements outlined in UL
Standard 94V–0.
Benefits
•
•
•
•
•
•
•
•
•
•
•
Axial leaded form factor
Conformally coated
Encapsulation meets flammability standard UL 94V–0
Operating temperature range of −55°C to +125°C
Lead (Pb)-free, RoHS and REACH compliant
X7R Temperature stable dielectric
DC voltage ratings of 25 V, 50 V, 100 V, 200 V, and 250 V
Capacitance offerings ranging from 10 pF to 10 μF
Available capacitance tolerances of ±5%, ±10% and ±20%
Non-polar device, minimizing installation concerns
100% pure matte tin-plated lead finish allowing for
excellent solderability
• SnPb-plated lead finish option available upon request
(Sn60/Pb40)
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
Ordering Information
C
Ceramic
410
Style/ Specification/
Size
Series
410
412
420
430
440
1
2
C
C=
Standard
105
Capacitance
Code (pF)
First two digits
represent
significant
figures. Third
digit specifies
number of
zeros.
K
Capacitance
Tolerance1
J = ±5%
K = ±10%
M = ±20%
3
R
Rated
Voltage Dielectric
(VDC)
3 = 25
R=
5 = 50
X7R
1 = 100
2 = 200
A = 250
5
T
A
7200
Design
Lead Finish2
Failure
Rate
Packaging
(C-Spec)
5=
Multilayer
T = 100% Matte Sn
H = SnPb (60/40)
A=
N/A
Blank = Bulk
7200 = 12" Reel
7293 = Ammo
Pack
Additional capacitance tolerance offerings may be available. Contact KEMET for details.
Lead materials:
Standard: 100% matte tin (Sn) with nickel (Ni) underplate and steel core ( “T” designation).
Alternative 1: 60% tin (Sn)/40% lead (Pb) finish with copper-clad steel core ( “H” designation).
Alternative 2: 60% tin (Sn)/40% lead (Pb) finish with 100% copper core (available with “H” designation code with C-Spec).
Contact KEMET for C-Spec details.
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
1
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Applications
Typical applications include decoupling, bypass, filtering and transient voltage suppression.
Application Notes
These devices are not recommended for use in overmold applications and/or processes.
Dimensions – Inches (Millimeters)
LL
L
D
LD
Series
C41X
C42X
C43X
C44X
0.015 (0.38)
Maximum
Style/
Size
L
Length
Maximum
D
Diameter
Maximum
410
0.170 (4.32)
0.095 (2.31)
412
0.170 (4.32)
0.120 (3.05)
420
430
440
0.200 (5.08)
0.240 (6.10)
0.260 (6.60)
0.100 (2.54)
0.150 (3.81)
0.150 (3.81)
LD
Lead Diameter
LL
Lead Length
Minimum
0.020+0.001/−0.003
1.0+0.001/−003
(0.51+0.025/−0.076) (25.4+0.025/−0.076)
Qualification/Certification
Commercial Grade products are subject to internal qualification. Details regarding test methods and conditions are
referenced in Table 2, Performance & Reliability.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
2
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Environmental Compliance
Lead (Pb)-free, REACH and RoHS compliant without exemptions when ordered with a 100% tin (Sn) wire lead finish.
Product ordered with tin/ lead (Sn60/Pb40) wire lead finish do not meet RoHS criteria.
Series
400 (C4XX)
1
Termination
Finish
(Wire Lead)
RoHS
Compliant
RoHS
Exemption
Code
REACH
Compliant1
Halogen
Free
100% Matte Sn
Yes
n/a
Yes
Yes
Sn60/Pb40
No
n/a
Yes
Yes
REACH compliance indicates product does not contain Substance/s of Very High Concern (SVHC)
Electrical Parameters/Characteristics
Item
Parameters/Characteristics
Operating Temperature Range
−55°C to +125°C Capacitance Change with Reference to
+25°C and 0 VDC Applied (TCC)
±15%
Aging Rate (Maximum % Cap Loss/Decade Hour)
3.0%
Dielectric Withstanding Voltage
Dissipation Factor (DF) Maximum Limit at 25°C
Insulation Resistance (IR) Limit at 25°C
250% of rated voltage
(5±1 second and charge/discharge not exceeding 50 mA at 25°C)
See Dissipation Factor Limit Table
See Insulation Resistance Limit Table
(Rated voltage applied for 120±5 seconds at 25°C)
Regarding aging rate: Capacitance measurements (including tolerance) are indexed to a referee time of 1,000 hours.
To obtain IR limit, divide MΩ-µF value by the capacitance and compare to GΩ limit. Select the lower of the two limits.
Capacitance and dissipation factor (DF) measured under the following conditions:
1 kHz ±50 Hz and 1.0 ±0.2 Vrms if capacitance ≤ 10 µF
120 Hz ±10 Hz and 0.5 ±0.1 Vrms if capacitance > 10 µF
Note: When measuring capacitance it is important to ensure the set voltage level is held constant. The HP4284 and Agilent E4980 have a feature known
as Automatic Level Control (ALC). The ALC feature should be switched to "ON."
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
3
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Insulation Resistance Limit Table
Style/Size
1,000 megohm microfarads
or 100GΩ
500 megohm microfarads
or 10GΩ
410
< 0.15µF
≥ 0.15µF
412
< 0.15µF
≥ 0.15µF
420
< 0.47µF
≥ 0.47µF
430
< 0.47µF
≥ 0.47µF
440
< 0.47µF
≥ 0.47µF
Post Environmental Limits
High Temperature Life, Biased Humidity and Storage Life
Style/Size
Rated
DC Voltage
>25
C410
25
C412, C420,
C440
Capacitance
Value
Dissipation Factor
(Maximum %)
< 1.0µF
3.0
≥ 1.0 μF
20.0
< 2.2 μF
5.0
≥ 2.2 μF
20.0
>25
All
25
>25
C430
25
3.0
Capacitance
Shift
± 20% Insulation
Resistance
10% of Initial
Limit
5.0
All
3.0
< 10.0µF
5.0
≥ 10.0 μF
20.0
Dissipation Factor (DF) Limit Table
Style/Size
Rated
DC Voltage
25
C410
> 25
C412, C420, C440
C430
25
> 25
25
> 25
Rated
Capacitance
Dissipation Factor
(Maximum %)
< 2.2 μF
3.5
≥ 2.2 μF
10.0
< 1.0 μF
2.5
≥ 1.0 μF
10.0
All
3.5
2.5
< 10.0 μF
3.5
≥ 10.0 μF
10.0
All
2.5
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
4
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Table 1A – C410 Style/Size, Capacitance Range Waterfall
C410 Style/Size (0.095" Diameter x 0.170" Length)
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
Capacitance
10pF
12pF
15pF
18pF
22pF
27pF
33pF
39pF
47pF
56pF
68pF
82pF
100pF
120pF
150pF
180pF
220pF
270pF
330pF
390pF
470pF
560pF
680pF
820pF
1000pF
1200pF
1500pF
1800pF
2200pF
2700pF
3300pF
3900pF
4700pF
5600pF
6800pF
8200pF
0.01µF
0.012µF
0.015µF
0.018µF
0.022µF
0.027µF
0.033µF
0.039µF
0.047µF
0.056µF
0.068µF
0.082µF
0.1µF
0.12µF
0.15µF
0.18µF
0.22µF
0.27µF
0.33µF
0.39µF
0.47µF
0.56µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
J = ±5%
K = ±10%
M = ±20%
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
5
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Table 1A – C410 Style/Size, Capacitance Range Waterfall cont'd
C410 Style/Size (0.095" Diameter x 0.170" Length)
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
Capacitance
0.68µF
0.82µF
1.0µF
2.2µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
684
824
105
225
684
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
J = ±5%
K = ±10%
M = ±20%
105
Table 1B – C412 Style/Size, Capacitance Range Waterfall
C412 Style/Size (0.120" Diameter x 0.170" Length)
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
Capacitance
470pF
560pF
680pF
820pF
1000pF
1200pF
1500pF
1800pF
2200pF
2700pF
3300pF
3900pF
4700pF
5600pF
6800pF
8200pF
0.01µF
0.012µF
0.015µF
0.018µF
0.022µF
0.027µF
0.033µF
0.039µF
0.047µF
0.056µF
0.068µF
0.082µF
0.1µF
0.12µF
0.15µF
0.18µF
0.22µF
0.27µF
0.33µF
0.39µF
0.47µF
0.56µF
0.68µF
0.82µF
1.0µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
J = ±5%
K = ±10%
M = ±20%
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
6
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Table 1C – C420 Style/Size, Capacitance Range Waterfall
C420 Style/Size (0.100" Diameter x 0.200" Length)
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
Capacitance
470pF
560pF
680pF
820pF
1000pF
1200pF
1500pF
1800pF
2200pF
2700pF
3300pF
3900pF
4700pF
5600pF
6800pF
8200pF
0.01µF
0.012µF
0.015µF
0.018µF
0.022µF
0.027µF
0.033µF
0.039µF
0.047µF
0.056µF
0.068µF
0.082µF
0.1µF
0.12µF
0.15µF
0.18µF
0.22µF
0.27µF
0.33µF
0.39µF
0.47µF
0.56µF
0.68µF
0.82µF
1.0µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
123
153
183
223
273
333
393
473
563
683
823
104
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
J = ±5%
K = ±10%
M = ±20%
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
7
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Table 1D – C430 Style/Size, Capacitance Range Waterfall
C430 Style/Size (0.150" Diameter x 0.240" Length)
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
Capacitance
0.022µF
0.027µF
0.033µF
0.039µF
0.047µF
0.056µF
0.068µF
0.082µF
0.1µF
0.12µF
0.15µF
0.18µF
0.22µF
0.27µF
0.33µF
0.39µF
0.47µF
0.56µF
0.68µF
0.82µF
1.0µF
1.2µF
1.5µF
1.8µF
2.0µF
2.2µF
2.7µF
3.3µF
3.9µF
4.7µF
10µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
125
155
185
205
225
275
335
395
475
106*
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
125
155
185
205
225
223
273
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
223
273
333
393
473
563
683
823
104
124
154
223
273
333
393
473
563
683
823
104
124
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
J = ±5%
K = ±10%
M = ±20%
* Only available on K and M tolerances.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
8
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Table 1E – C440 Style/Size, Capacitance Range Waterfall
C440 Style/Size (0.150" Diameter x 0.260" Length)
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
Capacitance
0.033µF
0.039µF
0.047µF
0.056µF
0.068µF
0.082µF
0.1µF
0.12µF
0.15µF
0.18µF
0.22µF
0.27µF
0.33µF
0.39µF
0.47µF
0.56µF
0.68µF
0.82µF
1.0µF
1.2µF
1.5µF
1.8µF
2.0µF
2.2µF
2.7µF
3.3µF
3.9µF
4.7µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
125
155
185
205
225
275
335
395
475
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
564
684
824
105
125
155
185
205
225
333
393
473
563
683
823
104
124
154
184
224
274
334
394
474
333
393
473
563
683
823
104
124
333
393
473
563
683
823
104
124
Rated Voltage (VDC)
25
50
100
200
250
Voltage Code
3
5
1
2
A
J = ±5%
K = ±10%
M = ±20%
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
9
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Soldering Process
Recommended Soldering Methods:
• Solder Wave
• Hand Soldering (Manual)
Recommended Soldering Profile:
• Optimum Wave Solder Profile
Solder Wave Peak
Temperature 260ºC
Entrance to Solder Wave
Degrees – Cº
Flux Zone
250
225
200
175
150
125
100
75
50
25
Exit from Solder Wave
(Time in Wave – 2 to 4 Seconds)
Preheat Zone
Hot Air Debridging
Exit from
Solder
Machine
80ºC
to 120ºC
Entrance
to Solder
Machine
Free
Air
Cool
Bottom Side
Temperature
Range
Entrance to
In-Line Cleaner
Exit from
In-Line Cleaner
(time in cleaner
may be less)
Immersion in
Cleaning
Vapor
150ºC
Maximum
Top Side
Nominal
0
1
2
3
Time (Minutes)
4
5
6
Mounting
All encased capacitors will pass the Resistance to Soldering Heat of MIL-STD-202, Method 210, Condition C. This test
simulates wave solder topside board mount product. This demonstration of resistance to solder heat is in accordance with
what is believed to be the industry standard. More severe treatment must be considered reflective of an improper soldering
process.
The above figure is a recommended solder wave profile for both axial and radial leaded ceramic capacitors.
• Hand Soldering (Manual)
Manual Solder Profile with Pre-heating
Soldering
Gradual Cooling
Gradual Preheat
60 – 120 Seconds
Recommend 2.5ºC/second
Maximum 3 seconds
Delta T < = 120ºC
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
10
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions
Stress
Reference
Solderability
J-STD-002
Temperature Cycling
JESD22 Method JA-104
Test or Inspection Method
Magnification 50X. Conditions:
a) Method A, at 235°C, Category 3
5 cycles (−55°C to +125°C), measurement at 24 hours +/−4 hours after test conclusion.
Load humidity, 1,000 hours 85°C/85%RH and rated voltage. Add 100 K ohm resistor.
Measurement at 24 hours +/−4 hours after test conclusion.
Low volt humidity, 1,000 hours 85C°/85%RH and 1.5 V. Add 100 K ohm resistor.
Measurement at 24 hours +/−4 hours after test conclusion.
t = 24 hours/cycle. Steps 7a & 7b not required. Unpowered. Measurement at 24 hours +/−4
hours after test conclusion.
−55ºC to +125°C. Note: Number of cycles required = 300. Maximum transfer time = 20
seconds. Dwell time −15 minutes. Air – Air.
Biased Humidity
MIL-STD-202 Method 103
Moisture Resistance
MIL-STD-202 Method 106
Thermal Shock
MIL-STD-202 Method 107
High Temperature Life
MIL-STD-202 Method 108
/ EIA -198
Storage Life
MIL-STD-202 Method 108
125°C, 0 VDC for 1,000 hours.
MIL-STD-202 Method 204
5 g for 20 minutes, 12 cycles each of 3 orientations. Note: Use 8"X5" PCB .031" thick 7
secure points on one long side and 2 secure points at corners of opposite sides. Parts
mounted within 2" from any secure point. Test from 10-2000 Hz.
Vibration
Resistance to Soldering
MIL-STD-202 Method 210
Heat
1,000 hours at 125°C (85°C for Z5U) with 1 X rated voltage applied.
Condition B. No preheat of samples. Note: single wave solder – procedure 2.
Terminal Strength
MIL-STD-202 Method 211
Conditions A (454g), Condition C (227g)
Mechanical Shock
MIL-STD-202 Method 213
Figure 1 of Method 213, Condition C.
Resistance to Solvents MIL-STD-202 Method 215
Add aqueous wash chemical – OKEM Clean or equivalent. Storage & Handling
The un-mounted storage life of a leaded ceramic capacitor is dependent upon storage and atmospheric conditions as
well as packaging materials. While the ceramic chips enveloped under the epoxy coating themselves are quite robust
in most environments, solderability of the wire lead on the final epoxy-coated product will be degraded by exposure to
high temperatures, high humidity, corrosive atmospheres, and long term storage. In addition, packaging materials will be
degraded by high temperature and exposure to direct sunlight–reels may soften or warp, and tape peel force may increase.
KEMET recommends storing the un-mounted capacitors in their original packaging, in a location away from direct sunlight,
and where the temperature and relative humidity do not exceed 40 degrees centigrade and 70% respectively. For optimum
solderability, capacitor stock should be used promptly, preferably within 18 months of receipt. For applications requiring
pre-tinning of components, storage life may be extended if solderability is verified. Before cleaning, bonding or molding these
devices, it is important to verify that your process does not affect product quality and performance. KEMET recommends
testing and evaluating the performance of a cleaned, bonded or molded product prior to implementing and/or qualifying any
of these processes.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
11
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Construction
Detailed Cross Section
Finish Layer
(Sn)
Finish Layer
(Sn)
Epoxy
Barrier Layer
Encapsulation
(Ni)
External Electrode
(Cu)
Dielectric Material
(BaTiO3)
Barrier Layer
(Ni)
External Electrode
(Cu)
Inner Electrodes
(Ni)
Epoxy
Encapsulation
Lead Wire
Lead Attach Solder
(Sn95/Sb5)
Inner Electrodes
(Ni)
Alt 1
Std
Core Metal
Barrier Layer
Steel
Cu
Ni
100% 60% Sn
Finish Layer Matte Sn 40% Pb
Alt 2
Cu
—
60% Sn
40% Pb
Dielectric
Material (BaTiO3)
Inner Electrodes
(Ni)
Marking
KEMET
Trademark
Rated
Capacitance
1
Rated Working
DC Voltage
K3R
475K
1520
Dielectric Code
Capacitance
Tolerance
15
20
Manufacturing Year:
15 = 2015
Manufacturing Week:
20 = Week 20
(of mfg. calendar year)
Date Code1
(Available as
an option only)
To properly request the inclusion of the date code in the marking, ordering code please contact your KEMET representative.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
12
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Packaging Quantities
Style/Size
Standard
Bulk
Quantity
410
300/Box
412
200/Box
420
300/Box
430
200/Box
440
200/Box
Ammo Pack
Quantity
Maximum
Reel
Quantity
Maximum
(12" Reel)
4000
5000
2000
2500
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
13
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
Tape & Reel Packaging Information
KEMET offers standard reeling of molded and conformally
coated axial leaded ceramic capacitors for automatic insertion
or lead forming machines in accordance with EIA standard
296. KEMET’s internal specification four-digit suffix, 7200, is
placed at the end of the part number to designate tape and reel
packaging, e.g., C410C104Z5U5CA7200.
Paper (50 lb.) test minimum is inserted between the layers
of capacitors wound on reels for component pitch ≤ 0.400".
Capacitor lead length may extend only a maximum of .0625"
(1.59 mm) beyond the tapes’ edges. Capacitors are centered in
a row between the two tapes and will deviate only ± 0.031" (0.79
mm) from the row center. A minimum of 36" (91.5 cm) leader
tape is provided at each finished length of taped components.
Universal splicing clips are used to connect the tape.
Table 3 – Ceramic Axial Tape and Reel Dimensions
Metric will govern
Dimensions — Millimeters (Inches)
Axial Capacitor
Body Diameter
0.0 to 5.0
(0.0 to 0.197)
A
±0.5 (0.020)
B
±1.5 (0.059)*
5.0 (0.197)
52.4 (2.062)
Symbol Reference Table
A
B
Component Pitch
Inside Tape Spacing
* Inside tape spacing dimension (B) is determined by the body diameter of the capacitor.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
14
Axial Leaded Multilayer Ceramic Capacitors
Aximax, 400 Series, Conformally Coated, X7R Dielectric, 25 – 250 VDC (Commercial Grade)
KEMET Electronic Corporation Sales Offices
For a complete list of our global sales offices, please visit www.kemet.com/sales.
Disclaimer
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1041_AXIMAX_X7R • 1/10/2017
15
Similar pages