Artesyn ADN20-24-1PM-C Total power: 120-960 watt Datasheet

POWER
ADN-C Series
120 - 960 Watts
Data Sheet
Total Power: 120-960 Watts
Input Voltage: 85-264 Vac,
90-375 Vdc
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Slim form factor
ƒƒ Five year warranty
ƒƒ High efficiency > 90% Typ.
ƒƒ Full power at 60 °C
ƒƒ Power Boost™
ƒƒ Industrial grade design
• Metal mounting clip
• Metal case
ƒƒ MTBF > 450,000h demonstrated
at 40 °C
ƒƒ Active PFC > 0.92
ƒƒ Adjustable output
ƒƒ Overvoltage protection with
autorecovery
ƒƒ Continuous short circuit and overload
protection
ƒƒ SEMI F47 Sag Immunity
ƒƒ New visual diagnostic LED
ƒƒ Three Status LEDs
• Input
• Output
• Alarm
ƒƒ DC OK relay
ƒƒ Parallel operation capability
ƒƒ Screw terminal connections
ƒƒ RoHS compliant
ƒƒ No tools required for mounting
SAFETY
ƒƒ UL508, cULus Listed
ƒƒ UL 60950-1, cURus
ƒƒ IEC60950-1
ƒƒ Class I, Div 2 Hazardous Locations
ƒƒ ATEX Certified on selected models
ƒƒ IP20
ƒƒ CE
Electrical Specifications
Input
AC input range
Nominal: 100-240 Vac/115-230 Vac/85-264 Vac
DC input range
90-375 Vdc
Frequency
47-67 Hz, 400 Hz
Efficiency
> 90%
Inrush current (typical)
< 15A or < 60A depending on model
PFC
Active, better than 0.92
Output
Nominal voltage
24 Vdc (22.5-28.5 Vdc Adj): ADN5-24-1PM-C & ADN10-24-1PM-C
24 Vdc (24-28 Vdc Adj): ADN20-24-1PM-C & ADN40-24-1PM-C
Initial voltage setting
24.5 V ± 1%
Hold-up time
> 20 ms at full load (100 Vac Input @ Tamb = +25 °C)
Voltage regulation
< ± 2% (combination line, load, time and temperature related changes)
Ripple
< 50 mVpp: ADN5-24-1PM-C & ADN10-24-1PM-C
< 100 mVpp: ADN20-24-1PM-C & ADN40-24-1PM-C
Back EMF immunity
< 35 Vdc
Power Boost™
1.5 x Nominal current for 2 or 4 seconds depending on model
Short circuit current
1.5 x Nominal current at near zero volts at short circuit condition
Parallel operation
Switch selectable single unit or parallel unit operation. Units will not be
damaged by parallel operation (regardless of switch position setting)
Ouput noise suppression
Radiated EMI values below EN61000-6-2
Overvoltage protection
> 30.5 Vdc but < 33 Vdc, auto recovery
Line and load regulation
< 0.5%
Time and temperature drift
< 1%
ADN-C Series Data Sheet
General Specifications
EMC emissions
EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including
Annex. A, EN61000-3-2
EMC immunity
EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3,
EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Installation class 4, EN61000-4-11, IEC
61000-4-34 voltage dip immunity standard
Warranty
5 Years
General protection safety
Protected against continuous short-circuit, continuous overload, continous open circuit. Protection Class 1
(IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1)
Status indicators
Visual: Three (3) status LEDs (Input, Output, Alarm) Relay: N.O. contact rated 200 mA/50 Vdc
LED Diagnostics
LED
OK
Loss of Ac
Low Ac
No Dc
High Load
Overload
Hot
Too Hot
Input
Green
---
Yellow
Green
Green
Green
Green
Green
Output
Green
---
Green
---
Yellow
Yellow
Green
---
Alarm
---
---
---
Red
Yellow
Red
Yellow
Yellow
Environmental Specifications
Storage temperature
-40 °C to + 85 °C; All models
Operating temperature
From -25 °C to 70 °C. Derate starting at 60 °C; All models
Up to 50% load permissable with horizontal or on top mounting orientation
Other Features
External fusing
Not required. Unit provides internal fuse (not accessible)
Mounting orientation
Standard: Vertical, Optional: Horizontal or on Top
Simple snap-on to DIN TS35/7.5 or TS35/15 rail system
Ventilation
Normal convection, No fan required
Cooling spacing
ADN5-24-1PM-C & ADN10-24-1PM-C:
ADN20-24-1PM-C:
ADN40-24-1PM-C:
Connections
Input: Screw terminals, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid conductors
Output:Two terminals per output, connector size range: 16-10 AWG (1.5 - 6 mm2) for solid conductors
One terminal per output for ADC40-24-1PM-C, connector size range: 7-6 AWG (10.6 - 13 mm2) for
solid conductors
15 mm in front, 25 mm above and below, 10 mm left and right
15 mm in front, 40 mm above and below, 10 mm left and right
15 mm in front, 25 mm above and below, 25 mm left and right
ADN-C Series Data Sheet
Ordering Information
MTBF
Model Number
Power
Input Voltage
Weight
Current
Case Type
ADN5-24-1PM-C
120 W
85-264 Vac
90-375 Vdc*
1.10 lbs (500 g)
5 A @ 24 Vdc
Metal with mounting clip
550,000 hours
ADN10-24-1PM-C
240 W
1.98 lbs (900 g)
10 A @ 24 Vdc
Metal with mounting clip
550,000 hours
ADN20-24-1PM-C
480 W
2.6 lbs (1200 g)
20 A @ 24 Vdc
Metal with mounting clip
450,000 hours
ADN40-24-1PM-C
960 W
6.0 lbs (2750 g)
40 A @ 24 Vdc
Metal with mounting clip
500,000 hours
85-264 Vac
90-375 Vdc*
85-264 Vac
90-375 Vdc*
100-240 Vac
Demonstrated at 40 °C
*No UL listed for DC input
Dimensions
Height
Width
Depth
ADN5-24-1PM-C
4.85 in (123 mm)
1.97 in (50 mm)
4.37 (111 mm)
ADN10-24-1PM-C
4.85 in (123 mm)
2.36 in (60 mm)
4.37 (111 mm)
ADN20-24-1PM-C
4.85 in (123 mm)
3.42 in (87 mm)
4.96 in (126 mm)
ADN40-24-1PM-C
4.85 in (123 mm)
7.09 in (180 mm)
4.81 in (122 mm)
Mechanical Drawing
D
W
+
-
+
OK
24 VDC / 5 A
Input
Output
Alarm
22.5 - 28/5 Vdc
Single
H
Parallel
ADN5-24-1PM-C
C
U
L
US LISTED
115/230 V ~ 2.2/1.0 A 50/60 HZ
N
L
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2015 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
ADN-C DS 09Dec2015
Similar pages