0-10V Dimmable Constant Current Mode 60-DBFE Series www.linkcom.com.tw For more information, please contact with: [email protected] FEATURES: ● AC Input 90~305 Vac Nominal ● Built-in Active Power Factor Correction ● Protection: SCP / OVP / OTP ● High Operating Ambient Temp.: -20℃~+60℃ ● THD: <20% @ 277VAC Full Load ● Surge Protection: L-N 1 kV, L/N-FG 2 kV ● Safety: UL ● EMI: Meets CE / Meets FCC ● Comply with Indoor/Outdoor Waterproof (IP 67) ● Warranty: 3 years (refer to LinkCom warranty policy) ● 0-10V dimming ● RoHS Compliant PRODUCT SPECIFICATION DC OUTPUT POWER(W) DC OUTPUT VOLTAGE(V) OUTPUT CURRENT(A) OUTPUT CURRENT TOLERANCE EFFICIENCY O/P NOISE (pk-pk,V) DBFE0060U132 62.4 42-48V 1.3 ±5% 86% 4.6V DBFE0060U142 58.8 33-42V 1.4 ±5% 86% 4.2V DBFE0060U152 60.0 30-40V 1.5 ±5% 86% 4V DBFE0060U172 61.2 30-36V 1.7 ±5% 86% 3.6V DBFE0060U212 63.0 24-30V 2.1 ±5% 86% 3.6V DBFE0060U252 60.0 19-24V 2.5 ±5% 86% 2.7V DBFE0050U432 51.6 9-12V 4.3 ±5% 82% 2V MODEL ELECTRICAL SPECIFICATION INPUT VOLTAGE RANGE 90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac INPUT FREQUENCY Range: 47-63Hz, Normal: 50-60Hz ACTIVE POWER FACTOR > 0.95 @ 110 Vac; > 0.9 @ 230 Vac THD < 20% at Full Load 100-277 Vac TURN ON DELAY TIME 3000 ms at Full Load 115 Vac / 230 Vac AC CURRENT 0.8 A / 110 Vac; 0.4 A / 230 Vac INRUSH CURRENT (typ) Cold Start 50 A @ 230 Vac LEAKAGE CURRENT < 0.75 mA at 277 Vac SHORT CIRCUIT PROTECTION OVER VOLTAGE PROTECTION automatically after the fault condition is removed OVER TEMP. PROTECTION -20℃ ~ +60 ℃ @ Full Load 110-277 Vac OPERATING TEMP. -40 ℃ ~ +80 ℃ STORAGE TEMP. RELATIVE HUMIDITY 10% to +90%, non-cond. SAFETY UL 8750 EMI Meets FCC Part15 / Meets EN 55015 WITHSTAND VOLTAGE I/P-O/P:4242 Vdc, I/P-FG:2500 Vdc,I/P-CASE : 2500 Vdc ISOLATION RESISTANCE I/P-O/P, I/P-FG,O/P-FG : >10M Ω / 500 Vdc / 25℃ / 70% RH DIMENSION (L*W*H) 158 * 58 * 39.4 mm【6.22 * 2.28 * 1.55 inch】 (1) All parameters specified at 230 Vac input unless otherwise noted. (2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load. (3) Ripple and Noise measured directly at pins/terminals at nom. load, pk-pk at 20MHz bandwidth. (4) Specified for free-air convection cooling. (5) Minimum load is NOT required for proper operation . (6) 100% Production Tested. *REFERENCE: www.linkcom.com.tw *Please contact [email protected], [email protected] for more information Linkcom Manufacturing Co., Ltd. 5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw 0-10V Dimmable Constant Current Mode 60-DBFE Series www.linkcom.com.tw For more information, please contact with: [email protected] DIMENSIONS Tc Max. DBFE0060U252 as Tc Max. Reference *REFERENCE: www.linkcom.com.tw Linkcom Manufacturing Co., Ltd. 5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw 0-10V Dimmable Constant Current Mode 60-DBFE Series www.linkcom.com.tw For more information, please contact with: [email protected] DIMMING OPERATION (Typical) Parameters Absolute maximum voltageon on the 0-10(+) Purple Wire Source current on the 0-10V(+) Purple Wire Minimum Typical 1V ─ Maximum 10V 0mA ─ 1mA 0-10V Analog Dimming Typical Circuit (Leviton) IP710 Dimmer Purple(+) PDBFE0060XXXX-00G V Gray(-) (Lutron) NTSTV-DV Dimmer Red(+) Black(-) Dimming Performance 110% 100% 90% Output Current (%) 80% 70% 60% 50% 40% 30% 20% 10% 0% 0 1 2 3 4 5 6 7 8 9 10 Dimming input(Vdc) Notes: 1. 0-10V Dimmable must be connect to extra two wires +Purple/-Gray on the output side. 2. Recommended dimmers are Leviton IP710,Lutron NTSTV-DV or equivalent. 3. If output side wires +Purple/-Gray are open, the output current Io will be 100%. Linkcom Manufacturing Co., Ltd. 5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw 0-10V Dimmable Constant Current Mode 60-DBFE Series www.linkcom.com.tw For more information, please contact with: [email protected] Output Current vs. Load (DBFE-060U132-00) Output Current vs. Load Output Current (A) 1.320 1.310 1.300 Vin=100 Vin=120 1.290 Vin=200 Vin=230 Vin=277 1.280 84% 86% 88% 90% 92% 94% 96% 98% 100% 102% Load (%) Power Factor vs. Load (DBFE-060U132-00) PF vs. Load 1.00 Power Factor 0.95 0.90 Vin=100 Vin=120 0.85 Vin=200 Vin=230 Vin=277 0.80 86% 88% 90% 92% 94% 96% 98% 100% 102% Load (%) Efficiency vs. Load (DBFE-060U132-00) Efficiency vs. Load 90.0% Efficiency (%) 88.0% 86.0% Vin=100 84.0% Vin=120 Vin=200 82.0% Vin=230 Vin=277 80.0% 86% 88% 90% 92% 94% 96% 98% 100% 102% Load (%) Linkcom Manufacturing Co., Ltd. 5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw 0-10V Dimmable Constant Current Mode 60-DBFE Series www.linkcom.com.tw For more information, please contact with: [email protected] THD vs. Load (DBFE-060U132-00) THD vs. Load 20% THD (%) 15% 10% Vin=100 Vin=120 5% Vin=200 Vin=230 Vin=277 0% 86% 88% 90% 92% 94% 96% 98% 100% 102% Load (%) Linkcom Manufacturing Co., Ltd. 5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw