LOW PASS FILTER SURFACE MOUNT MODEL: FLS-12 Fc = 12 MHz CUT-OFF FREQUENCY FEATURES: ► Small Size ► Optimum Performance 0.0 0.3 Passband Insertion Loss (dB) 0.5 0.8 1.0 1.3 1.5 1.8 2.0 2.3 2.5 2.8 3.0 0 1 2 3 4 5 6 7 8 9 10 11 Frequency (MHz) SPECIFICATIONS (Rev. A 10/10/07) Passband DC-10.7 MHz 3 dB Cut-off Frequency 12 MHz Passband Insertion Loss 1.0 dB (Max.) Stopband Frequencies @ 21 MHz @ 19 MHz @ 16 MHz Power Rating 1 Watt (Max.) Impedance 50 Ohms (Nom.) VSWR (Passband) 1.35:1 dB (Typ.) Operating Temperature Range -40 to +85 °C Package # 102S 35 dB (Min.) 23 dB (Min.) 20 dB (Min.) PORT CONFIGURATION Copyright © 2007 Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com Input Output Gnd. 1 8 All Other 12 LOW PASS FILTER SURFACE MOUNT MODEL: FLS-12 Fc = 12 MHz CUT-OFF FREQUENCY 10 20 30 40 50 60 70 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Frequency (MHz) 0 Return Loss (dB) 10 20 30 40 50 60 0 1 2 3 4 5 6 7 8 Frequency (MHz) S11 IN R.L S22 OUT R.L Copyright © 2007 Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com 9 10 11 12 PERFORMANCE PLOTS Transmission Response - Stopband Atten. (dB) 0 LOW PASS FILTER SURFACE MOUNT MODEL: FLS-12 Fc = 12 MHz CUT-OFF FREQUENCY Insertion Phase (deg.) -50 -100 -150 -200 -250 0 1 2 3 4 5 6 7 8 9 10 11 12 10 11 12 Frequency (MHz) 90 80 Group Delay (nSec) 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8 Frequency (MHz) Copyright © 2007 Synergy Microwave Corporation 201 McLean Boulevard • Paterson, New Jersey 07504 • Tel: (973) 881-8800 • Fax: (973) 881-8361 E-Mail: [email protected] • World Wide Web: http://www.synergymwave.com 9 PERFORMANCE PLOTS 0