MPU-250F Series Single Output 250W Power Factor Corrected AC/DC Power Supplies Key Features: • Small 250W Supply • PFC to EN 61000-3-2 “A” • EN 60950 Approved (UL) • CE Certified • FCC Class B Emissions • Universal AC Input • Internal Fan • Small 5” x 3.2” x 1.5” Size Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions Input Voltage Range Autoranging Input Frequency Input Current, Full Load Inrush Current, Cold Start Leakage Current Power Factor Correction Input Protection Min. 90 180 47 Typ. 110 VAC 6 220 VAC 3 110 VAC 220 VAC 264 VAC Meets EN 61000-3-2 Class A T8A/250V Fuse Max. 132 264 63 Units VAC Hz A 35 70 1.0 A mA Output Parameter Output Voltage Adjustment Output Regulation, See Note 1 Hold Time Ripple & Noise (20 MHz) See Note 2 Overload Protection Over Voltage Protection Over Temperature Protection Temperature Coefficient Transient Recovery Time, See Note 4 Transient Response Deviation Overshoot/Undershoot Turn On Delay Output Short Circuit Conditions Min. By Trim Pot Typ. ±5.0 ±1.0 Max. 110 VAC, 80% Load 20 See Model Selection Guide Autorecovery 110 140 >130% of Rated Output Voltage. Recycle AC Input. Autorecovery +110 ±0.04 2.5 50% Load Change 5 At Turn On/Off ±5.0 230 VAC 1 Continuous With Autorecovery Units % % mSec % ºC %/ºC mS % % S General Parameter Isolation Voltage, See Note 5 Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Primary - Core Fixed Min. 3,000 1,500 1,500 Typ. Max. Units VAC 25 kHz Interface Signals Power Supply On Green LED on the PCB Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. A TTL low signal inhibits the output. Hiccup mode. Power Good Signal MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Remote On/Off Environmental Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Operating Humidity Conditions Min. Typ. Max. Units 0 +25 +70 ºC 2.5%/ ºC from +50 ºC to + 70 ºC -20 +85 ºC See Model Selection Guide RH, Non-condensing 90 % Ambient Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 30ºC, Gnd Benign 100 kHours UL 60950, EN 60950 Compliance to EN 55022 (CISPR22) Class B; EN 61000-3-2,3 EN 61000-4-2,3,4,5,6,11; EN 55024; CE Marked (LVD) Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Model Number MPU-250S-12yF MPU-250S-15yF MPU-250S-24yF MPU-250S-48yF Output Voltage (VDC) PreSet 12 VDC 15 VDC 24 VDC 48 VDC Range 11.0 - 13.8 14.0 - 15.5 21.0 - 26.0 44.0 - 52.0 Output Current (Max. A) Ripple & Noise (% p-p) 20.83 16.66 10.42 5.21 ±1% ±1% ±1% ±1% Efficiency (%) Models with other output voltage levels are available (i.e. 5 VDC, 30 VDC, etc) Contact the factory for details at: [email protected] 80% 80% 80% 80% Notes: 1. Output regulation includes line & load. 2. Ripple & noise is measured from 10 Hz to 20 MHz. Connection to the unit is made with 0.1 µF ceramic & 22 µF electrolytic capacitors connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation specifications are production HI-Pot tested for 3 seconds. 5. The full output range (see table) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within the range without affecting the agency certification. For more information, contact the factory. 6. Output power is given for the factory preset voltage. The maximum continuous output power level is 300W. All models provide a peak power level of 600W for a maximum duration of 500 µS. For more information, contact the factory. 7. Each unit includes an input fuse (250V/8A). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Model Number Mechanical Dimensions Connections Input Connector (CN1): • Terminal Block: Howder HD-601-3P 3 pins, 6.35 mm Centers • Molex Mating Part No: Molex 09-91-0500 or equivalent (two pins removed) Pin Function 1 2 3 AC-Line AC-Neutral Field Ground Output Connector (CN2): • Terminal Block: Howder HD-601-4P 4 pins, 6.35 mm Centers • Molex Mating Part No: Molex 09-91-0600 or equivalent Pin Molex 1 2 3 4 5 6 +VOUT +VOUT +VOUT -VOUT -VOUT -VOUT Pin Howder 1 2 3 4 +VOUT +VOUT -VOUT -VOUT Logic Signal Connector (CN3): • Mating Part No: JST XHP-3 or equivalent (CHYAO SHIUNN JS-2001-03) • Mating Pins: JST SXH-002T-PO.6 For AWG 30 to 26 MicroPower Direct Pin Function 1 2 3 Power Good Remote On/Off Common Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]