Hynix HY29F040AT-15 512k x 8-bit cmos 5.0 volt-only, sector erase flash memory Datasheet

HY29F040A Series
512K x 8-bit CMOS 5.0 volt-only, Sector Erase Flash Memory
KEY FEATURES
· 5.0 V ± 10% Read, Program, and Erase
- Minimizes system-level power requirements
· High performance
- 55 ns access time
· Compatible with JEDEC-Standard Commands
- Uses software commands, pinouts, and
packages following industry standards for
single power supply Flash memory
· Minimum 100,000 Program/Erase Cycles
· Sector Erase Architecture
- Eight equal size sectors of 64K bytes each
- Any combination of sectors can be erased
concurrently; also supports full chip erase
· Erase Suspend/Resume
- Suspend a sector erase operation to allow a
data read or programming in a sector not
being erased within the same device
· Internal Erase Algorithms
- Automatically erases a sector, any combination
of sectors, or the entire chip
· Internal Programming Algorithms
- Automatically programs and verifies data at a
specified address.
· Low Power Consumption
- 40 mA maximum active read current
- 60 mA maximum program/erase current
- 5 mA maximum standby current
· Sector Protection
- Hardware method disables any combination
of sectors from a program or erase operation
DESCRIPTION
The HY29F040A is a 4 Megabit, 5.0 volt-only CMOS
Flash memory device organized as a 512K bytes
of 8 bits each. The device is offered in standard
32-pin PDIP, 32-pin PLCC and 32-pin TSOP packages. It is designed to be programmed and
erased in-system with a 5.0 volt power-supply and
can also be reprogrammed in standard PROM
programmers.
The HY29F040A offers access times of 55 ns, 70
ns, 90 ns, 120 ns and 150 ns. The device has separate chip enable (/CE), write enable (/WE) and output enable (/OE) controls. Hyundai Flash memory
devices reliably store memory data even after
100,000 program/erase cycles.
The HY29F040A is entirely pin and command set
compatible with the JEDEC standard for 4 Megabit Flash memory devices. The commands are written to the command register using standard microprocessor write timings. Register contents serve as
input to an internal state-machine which controls
the erase and programming circuitry. Write cycles
also internally latch addresses and data needed
for the programming and erase operations.
The HY29F040A is programmed by executing the
program command sequence. This will start the
internal byte programming algorithm that
automatically times the program pulse width and
also verifies the proper cell margin. Erase is
accomplished by executing either sector erase or
chip erase command sequence. This will start the
internal erasing algorithm that automatically times
the erase pulse width and also verifies the proper
cell margin. No preprogramming is required prior to
execution of the internal erase algorithm. Sectors
of the HY29F040A Flash memory array are electrically erased via Fowler-Nordheim tunneling. Bytes
are programmed one byte at a time using a hot
electron injection mechanism.
The HY29F040A features a sector erase architecture.
The device memory array is divided into 8 sectors of
64K bytes each. The sectors can be erased individually or in groups without affecting the data in
other sectors. The multiple sector erase and full
chip erase capabilities add flexibility to altering the
data in the device. To protect data in the device
from accidental program and erase, the device
also has a sector protect function. This function
hardware write protects the selected sectors. The sector
This document is a general product description and is subject to change without notice. Hyundai Electronics does not assume any
responsibility for use of circuits described. No patent licences are implied.
Rev.03/Aug.97
Hyundai Semiconductor
protect and sector unprotect features can be enabled in a PROM programmer.
The HY29F040A needs a single 5.0 volt powersupply for read, program and erase operation. Internally generated and well regulated voltages are
provided for program and erase operation. A low
Vcc detector inhibits write operations on loss of
power. End of program or erase is detected by /Data
Polling of DQ7 or by the Toggle Bit feature on DQ6.
Once program or erase cycle is successfully completed, the device internally resets to the Read
mode.
BLOCK DIAGRAM
DQ 0-DQ7
E rase V oltage
G en erato r
Vcc
Vss
Input/O utpu t
B uffers
State
C ontrol
WE
Com mand
R egister
P G M V oltage
G en erato r
Chip E nable
O u tput E nable
Log ic
CE
OE
STB
Y-D ecoder
V cc D etector
Tim e r
A 0-A18
2
HY29F040A
A ddress
Latch
STB
Data Latch
Y -G ating
Cell M atrix
X-D ecoder
PIN DESCRIPTION
Pin Name
Pin Function
A0 - A18
Address Inputs
DQ0 - DQ7
Data Input/Output
/CE
Chip Enable
/OE
Output Enable
/WE
Write Enable
Vss
Device Ground
Vcc
Device Power Supply
(5.0V ± 10 % for -70, -90, -120 and -150)
(5.0V ± 5 % for -55)
PIN CONNECTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
OE
A1 0
CE
DQ 7
DQ 6
DQ 5
DQ 4
DQ 3
V ss
DQ 2
DQ 1
DQ 0
A0
A1
A2
A3
OE
A1 0
CE
DQ 7
DQ 6
DQ 5
DQ 4
DQ 3
V ss
DQ 2
DQ 1
DQ 0
A0
A1
A2
A3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
3322
3311
3300
2299
2288
2277
2266
2255
2244
2233
2222
2211
2200
1199
1188
1177
27
A8
A4
7
26
8
25
A1 7
6
WE
A1 3
A6
30
A1 4
A7
28
V cc
29
5
31
4
A1 8
A1 7
A1 2
32
30
A1 6
3
1
WE
A1 5
A1 5
V cc
31
2
32
2
A1 2
1
A1 6
3
A1 8
A5
A1 1
A9
A8
A1 3
A1 4
A1 7
WE
V cc
A1 8
A1 6
A1 5
A1 2
A7
A6
A5
A4
Reverse TSOP
4
Standard TSOP
A7
5
29
A1 4
A6
6
28
A1 3
A5
7
27
A8
A1 1
A4
8
26
A9
9
25
A1 1
A9
A1 0
A2
10
24
OE
A1
11
22
CE
A1
11
23
A1 0
A0
12
21
DQ 7
A0
12
22
CE
DQ 0
13
20
DQ 6
DQ 0
13
21
DQ 7
DQ 1
14
19
DQ 5
DQ 2
15
18
DQ 4
V ss
16
17
DQ 3
PDIP
DQ 6
DQ 5
DQ 4
DQ 3
V ss
DQ 2
20
23
19
10
18
A2
17
OE
16
24
15
9
14
A3
A3
DQ 1
A1 1
A9
A8
A1 3
A1 4
A1 7
WE
V cc
A1 8
A1 6
A1 5
A1 2
A7
A6
A5
A4
PLCC
HY29F040A
3
BUS OPERATION
Table 1. Bus Operations(1)
OPERATION
/CE
/OE
/WE
A0
A1
A6
A9
I/O
Electronic ID Manufacturer Code(2)
L
L
H
L
L
L
VID
Code
Electronic ID Device Code(2)
L
L
H
H
L
L
VID
Code
Read(3)
L
L
H
A0
A1
A6
A9
DOUT
Standby
H
X
X
X
X
X
X
High Z
Output Disable
L
H
H
X
X
X
X
High Z
Write
L
H
L
A0
A1
A6
A9
DIN(4)
Enable Sector Protect
L
VID
L
X
X
X
VID
X
Verify Sector Protect
L
L
H
L
H
L
VID
Code
Notes:
1. L = VIL, H = VIH, X = Don’t Care. See DC Characteristics for voltage levels.
2. Manufacturer and device codes may also be accessed via a command register sequence. Refer to Table 4.
3. /WE can be VIL if /CE is VIL, /OE at VIH initiates the write operations.
4. Refer to Table 4 for valid DIN during a write operation.
Table 2. Sector Protection Verify Electronic ID Codes
Type
A18
A17
A16
A6
A1
A0
Code
HEX
DQ7
DQ6
DQ5
DQ4
Manufacture Code
X
X
X
V IL
VIL
V IL
ADH
1
0
1
0
HY29F040A
Device Code
X
X
X
V IL
VIL
VIH
A4H
1
0
1
0
0
0
Sector Protection
Sector Addresses
V IL
V IH
V IL
01H
(1)
DQ2
DQ1
DQ0
1
1
0
1
0
0
1
0
0
0
0
0
0
1
Notes:
1. Outputs 01H at protected sector addresses, and output 00H at unprotected sector addresses.
4
HY29F040A
DQ3
Table 3. Sector Addresses
A18
A17
A16
Address Range
SA0
0
0
0
00000H - 0FFFFH
SA1
0
0
1
10000H - 1FFFFH
SA2
0
1
0
20000H - 2FFFFH
SA3
0
1
1
30000H - 3FFFFH
SA4
1
0
0
40000H - 4FFFFH
SA5
1
0
1
50000H - 5FFFFH
SA6
1
1
0
60000H - 6FFFFH
SA7
1
1
1
70000H - 7FFFFH
Electronic ID Mode
Read Mode
The Electronic ID mode allows the reading out of
a binary code from the device and will identify its
manufacturer and device type. This mode is intended for use by programming equipment for the
purpose of automatically matching the device to be
programmed with its corresponding programming
algorithm. This mode is functional over the entire
temperature range of the device.
The HY29F040A has three control functions which
must be satisfied to obtain data at the outputs. /
CE is the power control and should be used for
device selection. /OE is the output control and
should be used to gate data to the output pins if a
device is selected. As shown in Table 1, /WE
should be held at VIH, except in Write mode and
Enable Sector Protect mode.
To activate this mode, the programming equipment
must force VID (11.5V to 12.5V) on address pin
A9. Two identifier bytes may then be sequenced
from the device outputs by toggling address A0
from VIL to VIH. All addresses are don’t cares except A0, A1, A6, and A9.
Address access time (tACC) is equal to the delay
from stable addresses to valid output data. The
chip enable access time (tCE) is the delay from
stable addresses and stable /CE to valid data at
the output pins. The output enable access time is
the delay from the falling edge of /OE to valid data
at the output pins (assuming the addresses have
been stable for at least tACC-tOE time).
The manufacturer and device codes may also be
read via the command register, (i.e., when
HY29F040A is erased or programmed in a system
without access to high voltage on the A9 pin). The
command sequence is illustrated in Table 4 (refer
to Electronic ID Command section).
Byte 0 (A0=VIL) represents the manufacturer’s code
(Hyundai Electronics=ADH) and byte 1 (A0=VIH)
the device identifier code (HY29F040A=A4H).
These two bytes are given in Table 2. All identifiers for manufacturer and devices will exhibit odd
parity with the MSB (DQ7) defined as the parity
bit. To permit reading of the proper device codes
when executing the Electronic ID, A1 must be VIL
(see Table 2).
Standby Mode
The HY29F040A has two standby modes: a CMOS
standby mode (/CE input held at Vcc ± 0.5V), when
current consumed is typically less than 1 mA; and a
TTL standby mode (/CE is held at VIH) when the
typical current required is reduced to 1 mA. In
standby mode, outputs are in a high impedance
state, independent of /OE input.
If the device is deselected during programming or
erase, the device will draw active current until the
programming or erase operation is completed.
HY29F040A
5
Output Disable Mode
With the /OE input at a logic high level (VIH), output
from the device is disabled. This will cause the
output pins to be in a high impedance state. It is
shown in Table 1 that /CE = VIL and /WE = VIH for
Output Disable. This is to differentiate Output Disable mode from Write mode and to prevent
inadvertant writes during Output Disable.
Write Mode
Device programming and erase are accomplished
via the command register. The contents of the register serve as inputs to the internal state machine.
Outputs of the state machine dictate the function
of the device.
The command register itself does not occupy any
addressable memory locations. The register is a
latch used to store the commands along with the
addresses and data information needed to execute
the command. The command register is written
by bringing /WE to VIL, while /CE is at VIL and /OE
is at VIH. Addresses are latched on the falling edge
of /WE or /CE, whichever happens later, while data
is latched on the rising edge of /WE or /CE, whichever happens first. Standard microprocessor
write timings are used. Refer to AC Characteristics for Programming/Erase and their respective
Timing Waveforms for specific timing parameters.
Enable Sector Protect and Verify
Sector Protect Modes
mode that disables both Programming and Erase
operation to protected sectors. In this device there
are 8 sectors of 64K bytes each. The sector protect
feature is enabled using programming equipment
at the user’s site. The device is shipped from
Hyundai’s factory with all sectors unprotected.
To activate the Sector Protect mode, the user
must force VID on address pin A9 and control pin /
OE. The sector addresses (A18, A17 and A16)
should be set to the sector to be protected (see
Table 3 for the sector address for each of the eight
individual sectors). Programming of the protection circuitry starts on the falling edge of /WE pulse
and is terminated with the rising edge of
/WE. Sector addresses must be held fixed during
the /WE pulse.
To verify programming of the protection circuitry,
the programming equipment must force VID on the
address pin A9 with /CE and /OE at V IL and
/WE at VIH. As shown in Table 2, scanning the
sector addresses (A18, A17 and A16) while (A6,
A1 and A0) = (0, 1, 0) will produce a 01H code at
the device output pins for a protected sector. In
the Verify Sector Protect mode, the device will read
00H for an unprotected sector. In this mode, the
lower order addresses, except for A0, A1 and A6,
are don’t care. Address locations with A1 = VIL are
reserved for electronic ID manufacturer and device codes. It is also possible to determine if a
sector is protected in-system by writing the Electronic ID command (described in the Electronic
ID command section below).
The HY29F040A has a hardware Sector Protect
6
HY29F040A
COMMAND DEFINITIONS
Device operations are selected by writing
specific address and data sequences into the
Command register. Writing incorrect addresses
and data values or writing them in the improper
sequence will reset the device to Read mode.
Table 4 defines the valid register command
sequences. Either Read/Reset command will
reset the device (when applicable).
Table 4. Command Definitions(1,2,3,4)
Command
Sequence
Bus
Write
Cycles
Req'd
First Bus
Write Cycle
Addr
Data
Second Bus
Write Cycle
Addr
Data
Third Bus
Write Cycle
Addr
Data
Fourth Bus
Write Cycle
Fifth Bus
Write Cycle
Addr
Addr
Data
Addr
Data
Sixth Bus
Write Cycle
Data
Read/Reset
1
XXXH
F0H
RA
RD
Read/Reset
4
5555H
AAH
2AAAH
55H
5555H
F0H
RA
RD
Electronic ID
4
5555H
AAH
2AAAH
55H
5555H
90H
XX00H
ADH
XX01H
A4H
Byte Program
4
5555H
AAH
2AAAH
55H
5555H
A0H
PA
PD
Chip Erase
6
5555H
AAH
2AAAH
55H
5555H
80H
5555H
AAH
2AAAH
55H
5555H
10H
Sector Erase
6
5555H
AAH
2AAAH
55H
5555H
80H
5555H
AAH
2AAAH
55H
SA
30H
Erase Suspend
1
XXXH
B0H
Erase Resume
1
XXXH
30H
Notes:
1. Bus Operations are defined in Table 1.
2. For a Command Sequence, address bits A15, A14, A13, A12, and A11 = X = Don’t care. Address bits A18, A17, A16,
and A15 = X = Don’t care for all address commands except for Program Address(PA) and Sector Address(SA).
In the case of Sector Address, address bit A15 = X = Don’t care for all addresses except for Program Address (PA)
and Sector Addresses (SA).
3. RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses are latched on the falling edge of the /WE pulse.
PD = Data to be programmed at location PA. Data is latched on the falling edge of /WE.
SA = Address of the sector to be erased (see Table 3).
4. The Erase Suspend (B0H) and Erase Resume (30H) commands are valid only while the Sector Erase operation
is in progress.
HY29F040A
7
Read/Reset Command
The read or reset operation is initiated by writing
the Read/Reset command sequence in to the command register. Microprocessor read cycles retrieve
the data from the memory. The device remains
enabled for reads until the command register contents are changed.
The device will automatically power-up in the Read/
Reset mode. In this case, a command sequence
is not needed to read the memory data. This default power-up to Read mode ensures that no spurious changes of the data can take place during
the power transitions. Refer to the AC Characteristics for Read-Only Operation and the respective
Timing Waveforms for the specific timing parameters.
Electronic ID Command
The HY29F040A contains an Electronic ID command to supplement the traditional PROM
programming method described in the Electronic
ID Mode section. The operation is initiated by
writing the Electronic ID command sequence into
the command register. Following the command
write, a read cycle from address XX00H retrieves
manufacturer code of ADH. A read cycle from address XX01H returns the device code A4H (see
Table 2). All manufacturer and device codes will
exhibit odd parity with the MSB (DQ7) defined as
the parity bit.
The Electronic ID command can also be used
to identify protected sectors. After writing the
Electronic ID command sequence, the CPU can
scan the sector addresses (A18, A17, A16) while
(A6, A1, A0) = (0, 1, 0). Protected sectors will
return 01H on the data outputs and unprotected
sectors will return 00H. To terminate the operation, it
is necessary to write the Read/Reset command
sequence into the command register.
Upon executing the Byte Programming command
sequence, the device’s internal state machine executes an internal byte programming algorithm. The
system is not required to provide further controls or timings. The device will automatically provide adequate internally generated program pulses
and verify the programmed cell margin of the byte.
During byte programming operation, data bit DQ7
shows the complement of the program data. This
operation is known as /Data Polling. The internal
byte programming algorithm has completed it’s
operation when the data on DQ7 is equivalent to
the last data written to this bit (see Write Operation
Status section). At the completion of the byte programming algorithm, the device returns to the read
mode. At this time, the address pins are no longer
latched. Therefore, the system must supply the last
program address at the completion of the byte programming operation to read the correct program
data on DQ7.
Byte programming is allowed in any sequence, and
across sector boundaries. However, remember that
a data “0” cannot be programmed to a data ”1".
Only erase operations can convert a logical ”0" to a
logical “1”. Attempting to program data from “0” to
“1” may cause the device to exceed time limits, or
even worse, result in an apparent success according to the /Data Polling algorithm. In the later case,
however, a subsequent read of this bit will show
that the data is still a logical “0”.
Figure 1 illustrates the Byte Programming
Algorithm using typical command strings and bus
operations.
Chip Erase Command
Byte Programming Command
The HY29F040A is programmed one byte at a time.
Programming is a four bus cycle operation (see
Table 4). The program address (PA) is latched on
8
the falling edge of /CE or /WE, whichever happens later, and program data (PD) is latched on
the rising edge of /CE or /WE, whichever happens
first. The rising edge of /CE or /WE, whichever
happens first, begins byte programming.
Chip erase is a six bus cycle operation (see Table 4).
Chip erase begins on the rising edge of the last /
WE pulse in the command sequence. There are
two 'unlock' write cycles. These are followed by
HY29F040A
writing the "set-up" command. Two more 'unlock'
write cycles are then followed by the chip erase
command.
Upon executing the Chip Erase command
sequence, the device’s internal state machine
executes an internal erase algorithm. The system is
not required to provide further controls or timings.
The device will automatically provide adequate internally generated erase pulses and verify chip
erase within the proper cell margins. During chip
erase, all sectors of the device are erased except
protected sectors.
During Chip Erase, data bit DQ7 shows a logical
“0”. This operation is known as /Data Polling. The
erase operation is completed when the data on DQ7
is a logical “1” (see Write Operation Status section). Upon completion of the Chip Erase
operation, the device returns to read mode. At this
time, the address pins are no longer latched. Note
that /Data Polling must be performed at a sector
address within any of the sectors being erased and
not a protected sector to ensure that DQ7 returns
a logical “1” upon completion of the Chip Erase
operation.
Figure 2 illustrates the Chip Erase Algorithm
using typical command strings and bus operations.
The device will ignore any commands written to
the chip during execution of the internal Chip Erase
algorithm.
Sector Erase Command
Sector erase is a six bus cycle operation (see Table
5). There are two 'unlock' write cycles that are followed by writing the "set-up" command. Two more
"unlock" write cycles are then followed by the sector erase command. The sector address (any address location within the desired sector) is latched
on the falling edge of /WE, while the command data
is latched on the rising edge of /WE. An internal device timer initiates Sector Erase operation after 100
ms ± 20% (80 ms to 120 ms) from the rising edge of
the /WE pulse for the last Sector Erase command
entered on the device.
Upon executing the Sector Erase command
sequence, the device’s internal state machine
executes an internal erase algorithm. The system is
not required to provide further controls or
timings. The device will automatically provide
adequate internally generated erase pulses and
verify sector erase within the proper cell margins.
Protected sectors of the device will not be erased,
even if they are selected with the Sector Erase
command.
Multiple sectors can be erased sequentially by writing the sixth bus cycle command of the Sector Erase
command for each sector to be erased. The time
between initiation of the next Sector Erase command must be less than 80 ms to guarantee acceptance of the command by the internal state machine. The time-out window can be monitored via
the write operation status pin DQ3 (refer to the Write
Operation Status section for Sector Erase Timer
operation). It is recommended that CPU interrupts
be disabled during this time to ensure that the subsequent Sector Erase commands can be initiated
within the 80 ms window. The interrupts can be reenabled after the last Sector Erase command is
written. As mentioned above, an internal device timer
will initiate the Sector Erase operation 100 ms ± 20%
(80 ms to 120 ms) from the rising edge of the last /
WE pulse. The Sector Erase Timer Write Operation
Status pin (DQ3) can be used to monitor the time out
window. If another falling edge of the /WE occurs
within the 100 ms time-out window, the internal device timer is reset. Loading the sector erase buffer
may be done in any sequence and with any number of sectors.
Any command other than Sector Erase or Erase
Suspend or Erase Resume during this period and
afterwards will reset the device to read mode, ignoring the previous command string. Resetting the
device after it has begun execution of a Sector
Erase operation will result in the data in the operated sectors being undefined. In this case, restart
the Sector Erase operation on those sectors and
allow them to complete the Erase operation.
When erasing a sector or multiple sectors, the data
in the unselected sectors remains unaffected. The
system is not required to provide any controls or
timings during these operations.
HY29F040A
9
During Sector Erase operation, data bit DQ7 shows
a logical “0”. This operation is known as
/Data Polling. Sector Erase operation is complete
when data on DQ7 is a logical “1” (see Write Operation Status section) at which time the
device returns to read mode. At this time, the
address pins are no longer latched. Note that
/Data Polling must be performed at a sector
address within any of the sectors being erased and
not a protected sector to ensure that DQ7 returns
a logical “1” upon completion of the Sector Erase
operation.
Figure 2 illustrates the Sector Erase Algorithm using typical command strings and bus operations.
During execution of the Sector Erase command, only
the Erase Suspend and Erase Resume commands are allowed. All other commands will reset
the device to read mode. Note: Do not attempt to
write an invalid command sequence during the
sector erase operation. Doing so will terminate the
sector erase operation and the device will reset to
the read mode.
Erase Suspend/Erase Resume
Commands
The Erase Suspend command allows the user to
interrupt a Sector Erase operation and read data
from or program to a sector that is not being erased.
The Erase Suspend command onthe HY29F040 also
allows for Byte Programming during the suspended
erase from a sector not being erased. The Erase
Suspend command is applicable only during Sector
Erase operation and will be ignored if written during
the Chip Erase operation or Byte Programming operation. The Erase Suspend command (B0H) will
be allowed only during the Sector Erase operation, including, but not limited to, the sector erase
time-out period after any Sector Erase commands
(30H) have been initiated.
10
Writing the Erase Suspend command during the
time-out will result in immediate termination of the
time-out period. Any subsequent writes of the Sector Erase command will be taken as the Erase
Resume command (30H). Note that any other commands during the time-out will reset the
device to the read mode. The address pins are
don’t-cares when writing the Erase Suspend or
Erase Resume commands.
When the Erase Suspend command is written during a Sector Erase operation, the chip will take a
maximum of 15 ms to suspend the erase operation and go into erase suspended-read mode.
During this time, the system can monitor the /Data
Polling or Toggle Bit write operation status flags to
determine when the device has entered erase suspend-read mode (see Write Operation Status section). The system must use an address of an erasing sector to monitor /Data Polling or Toggle Bit to
determine if the Sector Erase operation has been
suspended.
In the erase suspend-read mode, the system can
read data from any sector that is not being erased.
A read from a sector being erased may result in
invalid data.
After the system writes the Erase Suspend command and waits until the Toggle Bit stops toggling,
data reads from the device may then be performed.
Any further writes of the Erase Suspend command
at this time will be ignored.
To resume operation of Sector Erase, the Erase
Resume command (30H) should be written. Any
further writes of the Erase Resume command at
this point will be ignored. Another Erase Suspend
command can be written after the chip has resumed the Sector Erase operation.
HY29F040A
WRITE OPERATION STATUS
Table 5. Write Operation Status Flags (1)
In Progress
Status
DQ7
DQ6
DQ5
DQ3
Byte Programming Operation
Chip or Sector Erase Operation
Erase Suspend Erase Suspended Sector
/DQ7
0
1
Toggle
Toggle
No Toggle
0
0
0
0
1
N/A
Mode
Data
Data
Data
Data
/DQ7
Toggle
1
0
0
Toggle
1
1
/DQ7
Toggle
1
1
Non-Erase Suspended Sector
Exceeded
Byte Programming Operation
Time Limits
Chip or Sector Erase Operation
Program in Erase Suspend Mode
Notes:
1. DQ0, DQ1, DQ2, DQ4 are reserve pins for future use.
DQ7
/Data Polling
The HY29F040A device features /Data Polling as
a method to indicate to the host the status of the
Byte Programming, Chip Erase, and Sector Erase
operations. When the Byte Programming operation is in progress, an attempt to read the device
will produce the compliment of the data last written to DQ7. Upon completion of the Byte Programming operation, an attempt to read the device will
produce the true data last written to DQ7. When
the Chip Erase or Sector Erase operation is in
progress, an attempt to read the device will produce
a logical “0” at the DQ7 output. Upon completion of
the Chip Erase or Sector Erase operation, an attempt to read the device will produce a logical ”1" at
the DQ7 output. The flowchart for /Data Polling (DQ7)
is shown in Figure 3.
For Chip Erase, the /Data Polling is valid after the
rising edge of the sixth /WE pulse in the six write
pulse sequence. For Sector Erase, the /Data Polling is valid after the last rising edge of the sector
erase /WE pulse. For both Chip Erase and Sector Erase, /Data Polling must be performed at sector address within any of the sectors being erased
and not a protected sector. Otherwise, the /Data
Polling status may not be valid. Once the Internal
Algorithm operation is close to being completed,
the HY29F040A data pins (DQ7) may change asyn-
chronously while the output enable (/OE) is asserted low. This means that the device is driving status information on DQ7 at one instant of time and
valid data at the next instant of time. Depending on
when the system samples the DQ7 output, it may
read the status or valid data. Even if the device has
completed the Internal Algorithm operation and DQ7
has a valid data, data outputs on DQ0-DQ6 may be
still invalid. Valid data on DQ0-DQ7 will be read on
successive read attempts.
The Data Polling feature is only active during the
Byte Programming operation, Chip Erase
operation, Sector Erase Operation, or sector
erase time-out window (see Table 5).
DQ6
Toggle Bit
The HY29F040A also features the “Toggle Bit”
as a method to indicate to the host system the
status of the Internal Programming and Erase
Algorithms. The flowchart for Toggle Bit (DQ6) is
shown in Figure 4.
During an Internal Programming or Erase Algorithm
cycle, successive attempts to read (/OE toggling)
data from the device will result in DQ6 toggling
between one and zero. Once the Internal Programming or Erase operation is completed, DQ6
will stop toggling and valid data will be read on the
HY29F040A
11
next successive attempts. During Byte Programming,
the Toggle Bit is valid after the rising edge of the
fourth /WE pulse in the four write pulse
sequence. For Chip Erase, the Toggle Bit is valid
after the rising edge of the sixth /WE pulse in the
six write pulse sequence. For Sector Erase, the
Toggle Bit is valid after the last rising edge of the
sector erase /WE pulse. The Toggle Bit is also
active during the sector erase time-out window.
In Byte Programming, if the sector being written to is
protected, the Toggle Bit toggles for about 2 ms and
then stops toggling without the data having changed.
In Chip Erase or Sector Erase, the device will
erase all the selected sectors except for the ones
that are protected. If all selected sectors are protected, the chip will toggle the Toggle Bit for about
100 ms and then drop back into read mode, having
changed none of the data. Either /CE or /OE toggling will cause the DQ6 Toggle Bit to toggle.
DQ5
Exceeded Timing Limits
DQ5 will indicate if Byte Programming, Chip Erase,
or Sector Erase time has exceeded the specified
limits (internal pulse count) of the device. Under
these conditions DQ5 will produce a logical “1”. This
is a failure condition that indicates the program or erase
cycle was not successfully completed. /Data Polling is the only operating function of the device under
this condition. The /OE and /WE pins will control
output disable functions as described in Table 1.
If this failure condition occurs during Sector Erase
operation, it indicates a particular sector is bad
and it may not be reused. However, other sectors
are still functional and may continue to be used
for the program or erase operation. To use other
sectors of the device, it must be reset to Read
mode. Write the Read/Reset command sequence
to the device, and then execute the Byte Programming or Sector Erase command sequence. This
allows the system to continue to use the other
active sectors in the device.
Erase operation, it indicates the entire chip is bad
or combination of sectors are bad. In this situation, the chip should not be reused.
If this failure condition occurs during the Byte Programming operation, it indicates the entire sector
containing that byte is bad and this sector may not
be reused (other sectors are still functional and can
be reused).
The DQ5 failure condition may also appear if a
user tries to program a non-blank location without
erasing. In this example, the device may exceed time
limits and not complete the Internal Algorithm operation. Hence, the system never reads valid data
on DQ7 bit, and DQ6 never stops toggling. Once
the device has exceeded timing limits, the DQ5
bit will indicate a “1”.
DQ3
Sector Erase Timer
After the completion of the initial Sector Erase command sequence, the sector erase time-out window will begin. DQ3 will remain low until the timeout window is closed. /Data Polling and Toggle Bit
are valid after the initial Sector Erase command
sequence.
If /Data Polling or the Toggle Bit indicates the device has been written with a valid erase
command, DQ3 may be used to determine if the
Sector Erase time-out window is still open. If DQ3
is a logical “1”, the internally controlled erase cycle
has begun. Attempts to write subsequent command to the device will be ignored until the erase
operation is completed as indicated by /Data Polling or Toggle Bit. If DQ3 is a logical ”0", the device
will accept additional Sector Erase commands.
To insure the command has been accepted, the
system software should check the status of DQ3
prior to and following each subsequent Sector
Erase command. If DQ3 were high on the second
status check, the command may not have been
accepted. Refer to Table 5: Write Operation Status Flags.
If this failure condition occurs during the Chip
12
HY29F040A
DATA PROTECTION
Power-Up Write Inhibit
The HY29F040A is designed to offer protection
against accidental erasure or programming
caused by spurious system level signals that may
exist during power transitions. During power-up the
device automatically resets the internal state machine in the Read mode. Also, with its control register architecture, alteration of the memory contents only occurs after successful completion of specific multi-bus cycle command sequences. The
device also incorporates several features to prevent inadvertent write cycles resulting from Vcc
power-up and power-down transitions or
system noise.
Power-up of the device with /WE = /CE = VIL and
/OE = VIH will not accept commands on the rising
edge of /WE. The internal state machine is
automatically reset to Read mode on power-up.
Sector Protection
Sectors of the HY29F040A may be hardware
protected at the users factory. The protection
circuitry will disable both program and erase
functions for the protected sectors. Requests to
program or erase a protected sector will be
ignored by the device. Sector protection is
accomplished in a PROM programmer.
Low Vcc Write Inhibit
To avoid initiation of a write cycle during Vcc powerup and power-down, a write cycle is locked out for
Vcc less than 3.2V (typically 3.7V). If Vcc < VLKO,
the command register is disabled and all internal
programming/erase circuits are disabled. Under
this condition the device will reset to the Read
mode. Subsequent writes will be ignored until the
Vcc level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct to prevent unintentional writes when
Vcc is above 3.2V.
The HY29F040A features hardware sector protection that will disable both program and erase
operations to an individual sector or any group of
sectors. To activate this mode, programming
equipment must force VID on control pin /OE and
address pin A9. Sector addresses should be set
using higher address lines A18, A17 and A16. The
protection mechanism begins on the falling edge
of the /WE pulse and is terminated with the rising
edge of /WE. See Figures 13 and 14 for details of
implementing Sector Protect.
Sector Unprotect
Write Pulse “Glitch” Protection
Noise pulses of less than 5 ns (typical) on /OE,
/CE or /WE will not initiate a write cycle.
Logical Inhibit
Writing is inhibited by holding any one of
/OE = VIL, /CE = VIH , or /WE = VIH. To initiate a
write cycle /CE and /WE must be a logical “0” while
/OE is a logical “1”.
The HY29F040A also features a sector unprotect
mode, so that a protected sector may be unprotected to incorporate any changes in the code.
Protecting all sectors is necessary before
unprotecting any sector(s). Sector unprotection is
accomplished in a PROM programmer. See Figures 15 and 16 for details of implementing Sector
Unprotect.
HY29F040A
13
START
Write Program Command Sequence
(see below)
/Data Polling Device
NO
Increment Address
Last Address
?
YES
Programming Completed
Program Command Sequence (Address/Command)
5555H/AAH
2AAAH/55H
5555H/A0H
Program Address/Program Data
Figure 1. Internal Programming Algorithm
14
HY29F040A
Start
W rite E rase C om m and Sequ ence
(see below)
/Data P olling or Toggle Bit
S uccessfu lly C om p leted
E rase C o m p leted
Ch ip E rase Com m and Sequ ence
(A ddress/C om m and)
Ind ividual S e ctor/M ultiple Se ctor
E rase C om m and Sequ ence
(A ddress/C om m and)
5555 H /AA H
5555 H /AA H
2A A AH /55H
2A A AH /55H
5 555H /80H
5 555H /80H
5555 H /AA H
5555 H /AA H
2A A AH /55H
2A A AH /55H
5 555H /10H
S ector A d dre ss/30 H
S ector A d dre ss/30 H
A dd itio na l s ect or
eras e c om m a nd s
a re o ptiona l
S ector A d dre ss/30 H
Figure 2. Internal Erase Algorithm
HY29F040A
15
START
VA
Read Byte
(DQ0-DQ7), Addr = VA
=
=
=
DQ7 = Data
?
Byte address for programming
Any of the sector addresses
within the sector being erased
during sector erase operation.
XXXXH during Chip Erase
YES
NO
NO
DQ5 = 1
?
YES
Read Byte
(DQ0-DQ7), Addr = VA
DQ7 = Data
?
YES
NO
Fail
Pass
Notes:
1. DQ7 is rechecked even if DQ5 = logical “1” because DQ7 may change simultaneously with DQ5.
Figure 3. /Data Polling Algorithm
16
HY29F040A
START
Read Byte
(DQ0-DQ7)
DQ6 = Toggle
?
NO
YES
NO
DQ5 = 1
?
YES
Read Byte
(DQ0-DQ7)
DQ6 = Toggle
?
NO
YES
Fail
Pass
Notes:
1. DQ6 is rechecked even if DQ5 = logical “1” because DQ6 may stop toggling at the same
time as DQ5 changing to a logical ”1".
Figure 4. Toggle Bit Algorithm
HY29F040A
17
ABSOLUTE MAXIMUM RATINGS
OPERATING RANGES
Storage Temperature
Plastic Package .............................. -65°C to + 125°C
Ambient Temperature
With Power Applied .......................... -55°C to + 125°C
Voltage with Respect to Ground
All pins except A9 (1) .......................... -2.0V to + 7.0V
Vcc(1) ............................................... -2.0V to + 7.0V
A9(2) ............................................... -2.0V to + 14.0V
Output Short Circuit Current(3) ......................... 200 mA
Notes:
1. Minimum DC voltage on input or I/O pins
is - 0.5V. During voltage transitions, inputs may
overshoot Vss to -2.0V for periods of up to 20 ns.
Maximum DC voltage on output and I/O pins is Vcc +
0.5V. During Voltage transitions, outputs may
overshoot to Vcc + 2.0V for periods up to 20 ns.
Commercial( C) Devices ..................... 0°C to + 70°C
Industrial (I) Devices ........................ -40°C to + 85°C
Extended (E) Devices ..................... -55°C to + 125°C
Vcc Supply Voltages .................................................
Vcc for HY29F040A-55 .................. + 4.75V to + 5.25V
Vcc for HY29F040A-70, -90, -120, -150
.......................................................... + 4.5V to + 5.5V
Notes:
1. Operating ranges define those limits between which
the functionality of the device is guaranteed.
2. Minimum DC input voltage on A9 pin is -0.5V.
During voltage transitions, A9 may overshoot Vss
to -2.0V for periods of up to 20 ns. Maximum DC input
voltage on A9 is + 13.5V which may overshoot to 14.0V
for periods of up to 20 ns.
3.
No more than one output shorted at a time. Duration
of the short circuit should not be greater than one
second.
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device at these or any other conditions above those
18
indicated in the operational sections of this specification
is not implied. Exposure of the device to absolute maximum rating conditions for extended periods may affect
device reliability.
HY29F040A
20 ns
20 ns
+0.8 V
-0.5 V
- 2.0 V
20 ns
Figure 5. Maximum Negative Overshoot Waveform
20 ns
VCC + 2.0 V
VCC + 0.5 V
2.0 V
20 ns
20 ns
Figure 6. Maximum Positive Overshoot Waveform
HY29F040A
19
DC CHARACTERISTICS
TTL/NMOS Compatible
Parameter
Symbol
Parameter Description
Test Conditions
ILI
Input Load Current
VIN = Vss to Vcc, Vcc = Vcc Max.
ILIT
A9 Input Load Current
Vcc = Vcc Max., A9 = VID
ILO
Output Leakage Current
VOUT = Vss to Vcc, Vcc = Vcc Max.
ICC1
Vcc Active Current(1)
/CE = VIL, /OE = VIH
ICC2
Vcc Active Current(2,3)
ICC3
Vcc Standby Current
VIL
Input Low Level
VIH
Input High Level
VID
Voltage for Electronic ID
Min.
Max.
Unit
±1.0
mA
50
mA
±1.0
mA
40
mA
/CE = VIL, /OE = VIH
60
mA
Vcc = Vcc Max., /CE = VIH
1.0
mA
-0.5
0.8
V
2.0
Vcc
and Sector Protect
Vcc = 5.0 V
VOL
Output Low Voltage
IOL = 12 mA, Vcc = Vcc Min.
VOH
Output High Voltage
IOH = -2.5 mA, Vcc = Vcc Min.
VLKO
Low Vcc Lock-Out Voltage
11.5
+ 0.5
V
12.5
V
0.45
V
2.4
3.2
V
4.2
Notes:
1. The Icc current listed includes both the DC operating current and the frequency dependent component
(at 6 MHz). The frequency component typically is less than 1 mA/MHz, with /OE at VIH.
2. Icc active while Internal Algorithm (program or erase) is in progress.
3. Not 100% tested.
20
HY29F040A
V
DC CHARACTERISTICS (continued)
CMOS Compatible
Parameter
Symbol
Parameter Description
Test Conditions
ILI
Input Load Current
VIN = Vss to Vcc, Vcc = Vcc Max.
ILIT
A9 Input Load Current
Vcc = Vcc Max., A9 = VID
ILO
Output Leakage Current
VOUT = Vss to Vcc, Vcc = Vcc Max.
ICC1
Min.
Max.
Unit
±1.0
mA
50
mA
±1.0
mA
(1)
/CE = VIL, /OE = VIH
40
mA
(2,3)
/CE = VIL, /OE = VIH
60
mA
Vcc = Vcc Max., /CE = Vcc ± 0.5V
5.0
mA
V
Vcc Active Current
ICC2
Vcc Active Current
ICC3
Vcc Standby Current
VIL
Input Low Level
-0.5
0.8
VIH
Input High Level
0.7x
Vcc
Vcc
+ 0.3
V
VID
Voltage for Electronic ID
11.5
12.5
V
0.45
V
and Sector Protect
Vcc = 5.0 V
VOL
Output Low Voltage
IOL = 12 mA, Vcc = Vcc Min.
VOH1
Output High Voltage
IOH = -2.5 mA, Vcc = Vcc Min.
0.85x
V
Vcc
VOH2
IOH = -100 mA, Vcc = Vcc Min.
Vcc
V
-0.4
VLKO
Low Vcc Lock-out Voltage
3.2
4.2
V
Notes:
1. The Icc current listed includes both the DC operating current and the frequency dependent component (at 6 MHz).
The frequency component typically is less than 1 mA/MHz, with /OE at VIH.
2. Icc active while Internal Algorithm (program or erase) is in progress.
3. Not 100% tested.
HY29F040A
21
AC CHARACTERISTICS
Read Only Operations
Parameter Symbol
Description
Test Setup
-55(1)
-70(2)
-90 (2)
-120 (2) - 150(2)
Unit
JEDEC Standard
tAVAV
tRC
Read Cycle Time(3)
tAVQV
tACC
Address to
/CE = VIL
Output Delay
/OE = VIL
tELQV
tCE
Chip Enable to
/OE = VIL
Min.
55
70
90
120
150
ns
Max.
55
70
90
120
150
ns
Max.
55
70
90
120
150
ns
Max.
25
30
35
50
55
ns
Max.
18
20
20
30
35
ns
18
20
20
30
35
ns
0
0
0
0
0
ns
Output Delay
tGLQV
tOE
Output Enable to
Output Delay
tEHQZ
tHZ
Chip Enable to
Output High Z(3,4)
tGHQZ
tDF
Output Enable to
Output High Z(3,4)
t AXQX
tOH
Output Hold Time
from Addresses,
/CE or /OE,
Whichever
Occurs First
Min.
Notes:
1. Test Conditions:
2. Test Conditions:
Output Load: 1 TTL gate and 30 pF
Output Load: 1 TTL gate and 100 pF
Input rise and fall times: 5 ns
Input rise and fall times: 20 ns
Input pulse levels: 0.0 V to 3.0 V
Input pulse levels: 0.45 V to 2.4 V
Timing measurement reference level
Timing measurement reference level
Input: 1.5 V
Input: 0.8 and 2.0 V
Output: 1.5 V
Output: 0.8 and 2.0 V
22
HY29F040A
3. Output driver disable time.
4. Not 100% tested.
5.0 V
IN30 64 or
Equivalent
2.7 KO hm
D EV IC E
U ND E R
TE S T
CL
6.2 KO hm
D iode s = IN 3064
or Equivalent
Notes:
1. For -55: CL = 30pF including jig capacitance.
2. For all others: CL = 100pF including jig capacitance.
Figure 7. Test Condition
HY29F040A
23
AC CHARACTERISTICS
Programming/Erase Operations
Parameter Symbols
JEDEC Standard
Description
(1)
-55
-70
-90
-120
-150
Unit
ns
tAVAV
tWC
Write Cycle Time
Min.
55
70
90
120
150
tAVWL
t AS
Address Setup Time
Min.
0
0
0
0
0
ns
t WLAX
tAH
Address Hold Time
Min.
40
45
45
50
50
ns
tDVWH
tDS
Data Setup Time
Min.
25
30
45
50
50
ns
ns
tWHDX
tDH
Data Hold Time
Min.
0
0
0
0
0
t OES
Output Enable Setup Time
Min.
0
0
0
0
0
ns
tOEH
Output
Read(1)
Min.
0
0
0
0
0
ns
Enable
Hold Time
Toggle Bit &
/Data Polling(1)
Min.
10
10
10
10
10
ns
tGHWL
tGHWL
Read Recover Time Before Write Min.
0
0
0
0
0
ns
tELWL
tCS
/CE Setup Time
Min.
0
0
0
0
0
ns
WHEH
tCH
/CE Hold Time
Min.
0
0
0
0
0
ns
t
tWLWH
tWP
Write Pulse Width
Min.
30
35
45
50
50
ns
tWHWL
t WPH
Write Pulse Width High
Min.
20
20
20
20
20
ns
tWHWH1
tWHWH1
Typ.
7
7
7
7
7
ms
Max.
1.0
1.0
1.0
1.0
1.0
ms
tWHWH2
tWHWH2
Typ.
1.0
1.0
1.0
1.0
1.0
sec
Max.
15
15
15
15
15
sec
tWHWH3
tWHWH3
t VCS
Byte Programming Operation
Sector Erase Operation
Chip Erase Operation
Vcc Setup Time(1)
(1,2)
Typ.
8
8
8
8
8
sec
Max.
120
120
120
120
120
sec
Min.
50
50
50
50
50
ms
t VIDR
Rise Time to VID
Min.
500
500
500
500
500
ns
tOESP
/OE Setup Time to /WE Active(1,2)
Min.
4
4
4
4
4
ms
tVLHT
Voltage Transition Time (1,2)
Min.
4
4
4
4
4
ms
t WPP1
Sector Protect Write Pulse Width(2)
Min.
100
100
100
100
100
ms
(2)
t WPP2
Sector Unprotect Write Pulse Width
Min.
10
10
10
10
10
ms
t CSP
/CE Setup Time to /WE Active(1, 2)
Min.
4
4
4
4
4
ns
Notes:
1. Not 100% tested.
2. These timings are for Sector Protect and/or Sector Unprotect operations.
24
HY29F040A
SWITCHING WAVEFORMS
WAVEFORM
INPUTS
OUTPUTS
Must Be Steady
Will Be Steady
May Change
from H to L
Will Be Changing
from H to L
May Change
from L to H
Will Be Changing
from L to H
Don’t Care,
Any Change
Permitted
Changing, State
Unknown
Does Not
Apply
Center Line is
High Impedance
“Off” State
tRC
Addresses
Address Stable
tACC
CE
tHZ
tOE
OE
tDF
tOEH
WE
tCE
Outputs
tOH
High Z
High Z
Output Valid
Figure 8. AC Waveforms for Read Operations
HY29F040A
25
SWITCHING WAVEFORMS
Data Polling
Addresses
5555H
PA
PA
tAH
tWC
tAS
CE
tGHWL
OE
tWP
tWHWH1
WE
tWPH
tCS
tDH
Data
A0H
PD
DQ7
tDS
5.0V
VCC
GND
Notes:
1. PA is address of the memory location to be programmed.
2. PD is data to be programmed at byte address.
3. /DQ7 is the output of the complement of the data written to the device.
4. DOUT is the output of the data written to the device.
5. Figure indicates last two bus cycles of four bus cycle sequence.
Figure 9. AC Waveforms Program Operations
26
HY29F040A
DOUT
SWITCHING WAVEFORMS
tAS
tAH
Addresses
5555H
2AAAH
5555H
5555H
2AAAH
SA
CE
tGHWL
OE
tWP
WE
tWPH
tCS
tDH
Data
AAH
55H
80H
AAH
55H
10H/30H
tDS
tVCS
5.0V
VCC
GND
Notes:
1. SA is the sector address for Sector Erase. Address = X = Don’t Care for Chip Erase.
Figure 10. AC Waveforms Chip/Sector Erase Operations
HY29F040A
27
SWITCHING WAVEFORMS
tC H
CE
tD F
tO E
OE
tO E H
WE
tC E
tO H
H ig h
Z
DQ 7
DQ 7
D Q 7 = V a lid D a ta
tW H W H 1 o r 2
D a ta
D Q 0 -D Q 7
V a lid D a ta
D Q 0 -D Q 6= In valid
D Q 0 -D Q 6
tO E
5 .0 V
VC C
GN D
Notes:
1. DQ7 = Valid Data (The device has completed the internal program or erase operation.)
Figure 11. AC Waveforms for /Data Polling during Internal Algorithm Operations
28
HY29F040A
SWITCHING WAVEFORMS
CE
tO E H
WE
tO E S
OE
Data
Data
(D Q0-D Q7)
DQ 6 = Toggle
DQ6 =
S top Tog gling
DQ 6 = Toggle
DQ 0-DQ 7
V alid
tO E
5.0V
VCC
GND
Notes:
1. DQ6 stops toggling (The device has completed the internal program or erase operation)
Figure 12. AC Waveforms for Toggle Bit during Internal Algorithm Operations
HY29F040A
29
STAR T
S et U p S e c tor A d dres s
(A 1 8 , A 17, A 1 6)
P LS C N T = 1
A 9 = V ID
/O E = V ID
/C E = V IL
A ctivat e /W E P uls e
T im e O u t 10 0 µs
P ow e r D ow n / O E
/W E = V IH
/C E = /O E = V IL
A 9 R em ai ns a t V ID
Im p lem en t P L S C N T
A d d res s = S A
A 0 = V IL , A 1 = V IH , A 6 = V IL
No
P L S C NT = 25
?
Re ad fro m S ec tor
No
D ata = 01H
?
Yes
D e vic e F a ile d
Yes
P rote ct
A not her S ect o r?
No
P o w er D o wn A 9
S ec tor P ro te c t C om ple te
Figure 13. Sector Protection Algorithm
30
HY29F040A
Yes
SWITCHING WAVEFORMS
A18
A17
A16
SAX
SAY
12V
A9
tVLHT
tVLHT
12V
OE
tVLHT
CE
t CSP
tWPP1
WE
A0
A1
A6
Data
O1H
tOE
5.0V
VCC
GND
Notes:
1. SAX = Sector Address for initial sector
2. SAY = Sector Address for next sector
Figure 14. AC Waveforms for Sector Protection
HY29F040A
31
Start
Protect All Sectors
PLSCNT = 1
Set Up Sector Unprotect Mode
A6 = A12 = A16 = VIH
A9 = VID
/CE = VID
/OE = VID
Activate /WE Pulse
Time Out 10 ms
Increment PLSCNT
/WE = VIH
/CE = /OE = VIL
A9 Remains at VID
Set Up Sector Address = SA0
A0 = VIL, A1 = VIH, A6 = VIH
No
Read Data from Device
Yes
Increment Sector Address
No
Data = 00H
?
PLSCNT= 1000
?
Yes
No
Sector
Address = SA7
?
Yes
Device Failed
Yes
Power Down A9
Sector Unprotect Complete
Notes:
1. SA0 = Sector Address for initial sector
2. SA7 = Sector Address for the last sector
Figure 15. Sector Unprotect Algorithm
32
HY29F040A
SWITCHING WAVEFORMS
A6
A12
SA0
A16
12V
A9
12V
t VLHT
CE
t CE
t VLHT
12V
OE
t OESP
t VLHT
WE
t WPP2
A18
SA0
A17
A0
A1
Data
VCC
00H
5.0V
Notes:
1. Starts with SA0 and sequences to SA7.
2. See Figure 15 for details.
Figure 16. AC Waveforms for Sector Unprotect
HY29F040A
33
AC CHARACTERISTICS
Write / Erase / Program Operations
Alternate /CE Controlled Writes
Parameter
Symbols
JEDEC
Standard
Description
(1)
-55
-70
-90
-120
-150
Unit
tAVAV
tWC
Write Cycle Time
Min.
55
70
90
120
150
ns
tAVEL
tAS
Address Setup Time
Min.
0
0
0
0
0
ns
tELAX
tAH
Address Hold Time
Min.
40
45
45
50
50
ns
tDVEH
tDS
Data Setup Time Min.
25
30
45
50
50
ns
tEHDX
tDH
Data Hold Time
Min.
0
0
0
0
0
tOES
Output Enable Setup Time
Min.
0
0
0
0
0
ns
tOEH
Output
Read(1)
Min.
0
0
0
0
0
ns
Enable
Toggle Bit and
Min.
10
10
10
10
10
ns
Hold Time
/Data Polling(1)
ns
tGHEL
tGHEL
Read Recover Time Before Write
Min.
0
0
0
0
0
ns
tWLEL
tWS
/WE Setup Time
Min.
0
0
0
0
0
ns
tEHWH
t WH
/WE Hold Time
Min.
0
0
0
0
0
ns
tELEH
tCP
/CE Pulse Width
Min.
30
35
45
50
50
ns
tEHEL
tCPH
/CE Pulse Width High
Min.
20
20
20
20
20
ns
tWHWH1
tWHWH1
Byte Programming Operation
tWHWH2
tWHWH3
tWHWH2
tWHWH3
Sector Erase Operation(2)
Chip Erase Operation(2)
(1)
tVCS
VCC Set Up Time
tVIDR
Rise Time to VID(1,2)
tCESP
tVLHT
(1,2)
/OE Setup Time to /WE Active
(1,2)
Voltage Transition Time
(2)
Typ.
7
7
7
7
7
ms
Max.
1.0
1.0
1.0
1.0
1.0
ms
Typ.
1
1
1
1
1
sec
Max.
15
15
15
15
15
sec
Typ.
8
8
8
8
8
sec
Max.
120
120
120
120
120
sec
Min.
50
50
50
50
50
ms
Min.
500
500
500
500
500
ns
Min.
4
4
4
4
4
ms
Min.
4
4
4
4
4
ms
tWPP1
Sector Protect Write Pulse Width
Min.
100
100
100
100
100
ms
tWPP2
Sector Unprotect Write Pulse Width(2) Min.
10
10
10
10
10
ms
tCSP
/CE Setup Time to /WE Active(1,2)
4
4
4
4
4
ns
Min.
Notes:
1. Not 100% tested.
2. These timings are for Sector Protect and/or Sector Unprotect operations.
34
HY29F040A
SWITCHING WAVEFORMS
Data Polling
Addresses
5555H
PA
tWC
PA
tAH
tAS
WE
tGHEL
OE
tCP
tWHWH1
CE
tWS
tCPH
tDH
Data
AOH
PD
DQ7
DOUT
tDS
VCC
Notes:
1. PA is address of the memory location to be programmed.
2. PD is data to be programmed at byte address.
3. DQ7 is the output of the complement of the data written to the device.
4. DOUT is the output of the data written to the device.
5. Figure indicates last two bus cycles of four bus cycle sequence.
Figure 17. Alternate /CE Controlled Program Operation Timings
HY29F040A
35
ERASE AND PROGRAMMING PERFORMANCE
Parameter
Limits
Min.
Sector Erase Time
Unit
Typ.
Max.
1.0
15
sec
sec
Chip Erase Time
8
120
Byte Programming Time
7
1000
ms
Chip Programming Time
7
25
sec
Erase/Program Cycles
100,000
1,000,000
cycles
LATCH UP CHARACTERISTICS
Parameter
Min.
Max.
Input Voltage with respect to Vss on all I/O pins
-1.0V
Vcc + 1.0V
-100 mA
+ 100 mA
Vcc Current
Notes:
1. Includes all pins except Vcc. Test conditions: Vcc = 5.0V, one pin at a time.
PDIP PIN CAPACITANCE
Parameter Symbol
Parameter Description
Test Setup
Typ.
Max.
Unit
CIN
Input Capacitance
VIN = 0
4
6
pF
COUT
Output Capacitance
VOUT = 0
8
12
pF
CIN2
Control Pin Capacitance
VIN = 0
8
12
pF
Test Setup
Typ.
Max.
Unit
Notes:
1. Sampled, not 100% tested.
2. Test conditions TA = 25°C, f = 1.0 Mhz
PLCC PIN CAPACITANCE
Parameter Symbol
Parameter Description
CIN
Input Capacitance
VIN = 0
4
6
pF
COUT
Output Capacitance
VOUT = 0
8
12
pF
CIN2
Control Pin Capacitance
VIN = 0
8
12
pF
Notes:
1. Sampled, not 100% tested.
2. Test conditions TA = 25°C, f = 1.0 Mhz
TSOP PIN CAPACITANCE
Parameter Symbol
Parameter Description
Test Setup
Typ.
Max.
Unit
CIN
Input Capacitance
VIN = 0
6
7.5
pF
COUT
Output Capacitance
VOUT = 0
8.5
12
pF
CIN2
Control Pin Capacitance
VIN = 0
7.5
9
pF
Notes:
1. Sampled, not 100% tested.
2. Test conditions TA = 25°C, f = 1.0 MHz.
36
HY29F040A
DATA RETENTION
Parameter
Test Conditions
Minimum
Unit
Minimum Pattern Data Retention Time
150OC
10
Years
125OC
20
Years
HY29F040A
37
PACKAGE DRAWINGS - Physical Dimensions
TSOP32
0.95
32-Pin Standard Thin Small Outline Package (measured in millimeters)
1.05
Pin 1 I.D.
1
17
7.90
8.10
16
0.50 BSC
32
18.30
18.50
0.05
0.15
19.80
20.20
.0.08
.0.20
1.20
MAX
.0.18
.0.21
o
0
o
5
0.25MM (0.0098") BSC
.015
.060
PDIP32
32-Pin Plastic DIP (measured in inches)
1.640
1.680
32
.600
17
.625
.530
.008
.580
.015
Pin 1 I.D.
16
.630
.700
O
.005 MIN
.045
.065
0
10
O
.140
.225
.040
.225
SEATING PLANE
.120
.160
38
.090
.110
.014
.022
.015
.060
HY29F040A
PACKAGE DRAWINGS - Physical Dimensions
PLCC32
32-Pin Plastic Leaded Chip Carrier (measured in inches)
.485
.495
.447
.453
.009
.015
Pin 1 I.D.
.042
.056
.585 .547
.595 .553
.125
.140 .080
.095
SEATING
PLANE
.026
.032
.400
REF
.013
.021
.490
.530
.050 REF.
TOP VIEW
SIDE VIEW
HY29F040A
39
ORDERING INFORMATION
Hyundai products are available in several packages and operating ranges.
The order number (Valid Combination) is formed by a combination of the following:
HY29F040A
X
–X
X
X
SPECIAL INSTRUCTIONS
TEMPERATURE RANGE
Blank = Commercial (0OC to +70OC)
I = Industrial (–40OC to +85OC)
E = Extended (–55OC to +125OC)
SPEED OPTION
See Product Selector Guide and
Valid Combinations
PACKAGE TYPE
P = 32-Pin Plastic DIP (PDIP)
C = 32-Pin Rectangular Plasteic Leaded
Chip Carrier (PLCC)
T = 32-Pin Thin Small Outline Package
(TSOP) Standard Pinout
R = 32-Pin Thin Small Outline Package
(TSOP) Reverse Pinout
VALID COMBINATIONS
40
55ns
P-55, C-55, T-55, R-55
P-55I, C-55I, T-55I, R-55I
P-55E, C-55E, T-55E, R-55E
70ns
P-70, C-70, T-70, R-70
P-70I, C-70I, T-70I, R-70I
P-70E, C-70E, T-70E, R-70E
90ns
P-90, C-90, T-90, R-90
P-90I, C-90I, T-90I, R-90I
P-90E, C-90E, T-90E, R-90E
120ns
P-12, C-12, T-12, R-12
P-12I, C-12I, T-12I, R-12I
P-12E, C-12E, T-12E, R-12E
150ns
P-15, C-15, T-15, R-15
P-15I, C-15I, T-15I, R-15I
P-15E, C-15E, T-15E, R-15E
DEVICE NUMBER/DESCRIPTION
HY29F040A
4 Megabit (512K x 8-Bit) CMOS 5.0 volt-only.
Sector Erase Flash Memory.
VALID COMBINATIONS
Valid Combinations List configurations planned to
be supported in volume for this device. Consult the
local Hyundai sales office to confirm availability of
specific valid combinations and to check on newly
released combinations.
HY29F040A
Similar pages