MPD MPM08D0503MB Mpm-08mb sery Datasheet

MPM-08MB Series
Single & Dual Output, 8W
Miniature “Power Brick”
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 8W Output Power
• Miniature Case
• Wide 90-305 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Meets EN 55022 B
• Eight Standard Models
• >350 kHour MTBF
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
Typ.
90
120
47
See Model Selection Guide
115 VAC
25.0
230 VAC
45.0
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Leakage Current
EMI
EMC
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation, See Note 2
Load Regulation, See Note 3
Ripple (20 MHz), See Note 4
Noise
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Short Circuit Protection, See Note 5
Overload Protection
General
Parameter
Isolation Voltage
Isolation Resistance
EMI/RFI
EMC Compliance
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Switching Frequency
Environmental
Parameter
Operating Temperature Range, Ambient
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Vibration
Safety Approvals
Safety Class
Max.
305
430
440
Units
VAC
VDC
Hz
A Pk
0.25
mA
Max.
Units
Meets CISPR Pub. 22/FCC Class B
Meets EN 55024
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Note 1
±2.0
VIN = Min to Max
±0.2
See Model Selection Guide
3.3, 5, 9 12, 15 Vout Models
24 Vout Models
Dual Output Models
3.3, 5, 9 12, 15 Vout Models
24 Vout Models
Dual Output Models
115 VAC
10
230 VAC
75
±0.02
Zener Diode Clamp
120
Continuous (Autorecovery)
115
150
Conditions
Input to Output
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
3,000
100
Typ.
%
%
100
150
100
150
200
150
mV P - P
mV P - P
mSec
%/°C
% of VO
% of IO
Units
VAC
M⍀
EN 55022 Level B
EN 61000-4-2 Level B
EN 61000-4-3
EN 61000-4-4 Level 3 2 kV
EN 61000-4-5 Level 3 1kV/2 kV
132
kHz
Conditions
5.0/3.3 Vout Model
All Other Models
Max.
Min.
Typ.
Max.
-25
+25
+70
-40
+25
+70
-40
+125
Free Air Convection (See Derating Curves)
RH, Non-condensing
95
Units
°C
°C
%
1.44 x 1.06 x 1.04 Inches (36.5 x 27.0 x 26.4 mm)
Non-Conductive Plastic & Fiberglass (UL94-V0)
1.58 Oz (45g)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
350
kHours
10~55 Hz, 20G 1 min/1 Cycle. Period of 3 min each along X, Y &Z Axis
UL, cUL; File No. E245422
IEC 61140 Class II
www.micropowerdirect.com
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Current (A)
115 VAC
0.190
0.190
0.190
0.190
0.190
0.190
230 VAC
0.120
0.120
0.120
0.120
0.120
0.120
MPM-08D-0503MB
0.200
0.125
MPM-08D-1205MB
0.200
0.125
MPM-08S-03MB
MPM-08S-05MB
MPM-08S-09MB
MPM-08S-12MB
MPM-08S-15MB
MPM-08S-24MB
Output
Voltage
(VDC)
3.3
5.0
9.0
12.0
15.0
24.0
5.0
3.3
12.0
5.0
Load
Regulation
Current
Max. (A)
2.000
1.600
0.888
0.666
0.533
0.335
1.600
0.310
0.666
0.100
Min. (%)
0.0
0.0
0.0
0.0
0.0
0.0
25.0
25.0
25.0
25.0
Notes:
1. The output voltage accuracy of the V2 output (pin 5) on dual outputs is ±15% for the MPM-08D0503MB, and ±10% for the MPM-08D-1205MB.
2. The line regulation of the dual output models is ±2.0% for the V1 output (pin 4), and ±3% for
the V2 output (pin 5).
3. Load regulation is measured from 10% load to 100% load.
4. Ripple and noise are measured at 20 Mhz bandwidth with a 0.1µF and a 47 µF capacitor connected in parallel as close to the unit output terminals as possible.
5. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when
the fault condition is removed.
6. Operation under no load conditions will not damage single output units. For dual output units, minimum load
requirements are given in the table above.
7. It is recommended that a fuse be used on the input of a power supply for protection. For the
MPM-08MB series, a 2A/250 VAC slow blow should be used.
(% Max)
Maximum
Capacitive
Load
(µF)
±3.0
±2.0
±0.5
±0.5
±0.5
±0.5
±0.5
±5.0
±0.5
±5.0
26,000
6,000
2,300
1,050
440
180
4,500
3,800
260
3,800
Maximum
Efficiency
Output
Power
(%, Typ)
(W)
6.60
8.00
8.00
8.00
8.00
8.00
72
78
79
79
80
81
9.00
76
8.50
79
Mechanical Dimensions
Derating Curve - Single Output Models
Derating Curve - Dual Output Models
Pin Connections
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Pin
Single
Dual
1
AC-Line
2
AC-Neutral
3
-Vout
Common
4
+Vout
Vout1
5
NC
Vout2
NC = No Connection
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages