Kemet F862DI224K310C F862 series for harsh environmental conditions class x2, 310 vac Datasheet

Metallized Polypropylene
Film Capacitors
AUTOMOTIVE
Electronic Components
F862 Series for Harsh Environmental Conditions
Class X2, 310 VAC
Why Choose KEMET
KEMET Electronics Corporation is a leading
global supplier of electronic components. We
offer our customers the broadest selection of
capacitor technologies in the industry, along
with an expanding range of electromechanical
devices, electromagnetic compatibility solutions
and supercapacitors. Our vision is to be the
preferred supplier of electronic component
solutions for customers demanding the highest
standards of quality, delivery and service.
Applications
Across-the-line EMI filtering and connection in series with the mains
for high stability grade applications in severe ambient conditions:
•
•
•
•
•
Capacitive power supplies
Energy meters
DC applications
Industrial
Automotive
L1
Product Checklist
• Does your product use AC line power supply?
• What is the nominal AC line voltage?
• What is the circuit position and function
of the capacitor?
• Are there any voltage spikes expected?
• What is the ripple current spectrum?
• What is the capacitance value?
• What is the required capacitance stability?
• What is the size and lead spacing required?
• Are there any environmental concerns such
as temperature, moisture or vibration?
F1
CY
CX
Power line
D1
equipment
L2
D3
VAC
D2
CY
X2 in Parallel to the Mains
D4
Vout
X2 in Series with the Mains
Overview
X2 rated capacitors such as the F862 Series are required to achieve a stable performance during
operational life while meeting safety requirements. The metallized film dielectric is a key factor
with regards to the safety aspect. For example, the polypropylene dielectric provides excellent
self-healing characteristics. However, improvements were necessary to maintain stability in high
temperature and high humidity environments. KEMET recognized this challenges and researched
materials that would produce more robust parts for extreme applications. As a result, improvements
to all of the major capacitor components have been implemented, including the metallization layer,
the film used as the dielectric, the resin which fills the package, and the box (or case). With these
changes, the F862 offers very high capacitance stability while still meeting ENEC, CUL and CQC
international safety requirements.
THB Test at 85°C; 85% R.H.; 240 VAC
THB Test at 85°C; 85% R.H.; 240 VAC
Test time (hrs)
1000
0
-2
Test time (hrs)
250
500
750
1000
1250
1500
1750
2000
-4
-6
100
AC/C (%)
• High capacitance and dissipation factor stability
even in severe ambient conditions such as
high temperature and relative humidity
• Qualification based on AEC-Q200 guidelines
• Approvals: ENEC, UL, cUL, CQC
• Lead spacing of 15.0 – 27.5 mm
• Operating temperature range of -40˚C
to +110˚C
• Climatic category: 40/110/56, IEC 60068-1
• RoHS compliant and lead-free terminations
• 100% screening factory test at 1,900 VDC
• Tape in accordance with IEC 60286-2
• THB test at 85°C, 85% RH and 240 VAC for
1,000 hours
DISSIPATION FACTOR (10-4)
Features & Benefits
10
-8
-10
-12
-14
-16
-18
1
0
250
500
750
1000
1250
1500
1750
Dissipation Factor Stability
2000
-20
Capacitance Stability
www.kemet.com/f862
SA1016
Copyright © 2016 KEMET
Metallized Polypropylene
Film Capacitors
AUTOMOTIVE
Electronic Components
F862 Series for Harsh Environmental Conditions
Class X2, 310 VAC
Ordering Information
F
862
B
C
104
M
310
C
Capacitor Class
Series
Lead Spacing (mm)
Size Code
Capacitance Code (pF)
Capacitance Tolerance
Voltage (VAC)
Packaging
F = Film
X2, Metallized
Polypropylene
B = 15
D = 22.5
F = 27.5
See Dimensions Table
First two digits represent
significant figures. Third digit
specifies number of zeros.
310
See Ordering Options Table
K = ±10%
M = ±20%
Electrical/Physical Characteristics
Rated Voltage
310 VAC (50/60 Hz)
Capacitance Range
0.1 to 4.7 µF
Tolerance
±10%, ±20%
Temperature Range
-40°C to 110°C
Climatic Category
40/110/56
Case Size
See Dimensions Table
Maximum Values at +23°C
Dissipation Factor
1 kHz
C ≤ 0.1 µF
C > 0.1 µF
0.30%
0.20%
Minimum Values Between Terminals
Insulation Resistance
C ≤ 0.33 µF
≥ 30,000 MΩ
C > 0.33 µF
≥ 10,000 MΩ-µF
Temperature Humidity Bias (THB)
Environmental Test
85°C, 85% RH and 240 VAC, 1,000 hours. Capacitance change (∆C/C): ≤ 10%. Dissipation factor change (∆tan δ): ≤ 5 * 10−3 (at 1 kHz)
Insulation resistance Rins or time constant τ = CR. Rins: ≥ 50% of initial limit.
Dimensions Table
Capacitance Value
(µF)
0.1
0.15
0.22
0.33
0.39
0.47
0.56
0.15
0.22
0.33
0.39
0.47
0.56
0.68
0.82
1.0
1.2
1.0
1.5
2.2
3.3
4.7
Box Code
BK
BK
BP
BS
BS
BY
BZ
DB
DI
DJ
DJ
DO
DO
DP
DP
DU
DU
FC
FI
FN
FS
FY
B
7.5
7.5
8.5
10.0
10.0
11.0
12.0
6.0
7.0
8.5
8.5
10.0
10.0
11.0
11.0
13.0
13.0
11.0
13.0
14.0
19.0
22.0
Maximum Dimensions in mm
H
13.5
13.5
14.5
16.0
16.0
19.0
20.0
14.5
16.0
17.0
17.0
18.5
18.5
20.0
20.0
22.0
22.0
20.0
25.0
28.0
29.0
37.0
L
18.0
18.0
18.0
18.0
18.0
18.0
18.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
31.5
31.5
31.5
31.5
31.5
Lead Spacing
p
15.0
15.0
15.0
15.0
15.0
15.0
15.0
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
22.5
27.5
27.5
27.5
27.5
27.5
dV/dt
(V/µs)
400
400
400
400
400
400
400
200
200
200
200
200
200
200
200
200
200
150
150
150
150
150
Part Number
F862BK104(1)310(2)
F862BK154(1)310(2)
F862BP224(1)310(2)
F862BS334(1)310(2)
F862BS394(1)310(2)
F862BY474(1)310(2)
F862BZ564(1)310(2)
F862DB154(1)310(2)
F862DI224(1)310(2)
F862DJ334(1)310(2)
F862DJ394(1)310(2)
F862DO474(1)310(2)
F862DO564(1)310(2)
F862DP684(1)310(2)
F862DP824(1)310(2)
F862DU105(1)310(2)
F862DU125(1)310(2)
F862FC105(1)310(2)
F862FI155(1)310(2)
F862FN225(1)310(2)
F862FS335(1)310(2)
F862FY475(1)310(2)
(1) M = ±20%, K = ±10%
(2) Insert lead and packaging code. See table for available options.
SA1016
Copyright © 2016 KEMET