Bel FXP1500-32G Ac-dc power supply Datasheet

The FXP1500-32G is a 1500 watt, power factor
corrected (PFC) front-end, which provides a useradjustable 32 VDC (26-38 VDC range) main output
for test & measurement, RF amplifiers and
transmitters, factory automation, semiconductor
equipment, and other distributed power applications.
The FXP1500-32G provides for true hot-swap with
AC and DC connections at the rear of the model and
can be used for redundant system applications. Its
very small dimensions allow configuration of up to
three units in a 1U rack (up to 4500 W).2 The highlyefficient thermal design with internal fan cooling
permits its use in wide operating voltage and
temperature ranges to provide very high reliability.
















28 VDC, 32 VDC and 36 VDC output voltage preset
via VID pins
Margining via I2C
Active current/load sharing
Wide input voltage range 85-264 VAC
Highly-efficient topology yields 89% at 230 VAC
1U high: 5.6” x 1.6” x 12” cassette
Input fuse protected I2C
interface status and control
High density design:13.4W/in3
Up to 4500 W in a 1U-high, 19-inch wide rack
Standby voltage 5 VDC/1A
Adjustable output voltage
Overtemperature, output overvoltage and output
overcurrent protection
ORing circuit for true redundant operation
Status LEDs: AC OK, DC OK, Fan
Fail/Overtemperature Fail
Auto select power limits
Status information is provided with front panel LEDs,
logic signals, and via the I2C management interface.
In addition, the I2C bus can enable the power supply,
control the fan speed, adjust the output voltage, and
set the output current limit.
The FXP1500-32G meets international safety
standards and displays the CE-Mark for the
European Low Voltage Directive (LVD).

Test & Measurement,

RF Amplifiers & Transmitters

Factory Automation

Semiconductor & LD-MOS Based Equipment

other Distributed Power Applications
North America
+1-866.513.2839
Asia-Pacific
+86.755.29885888
Europe, Middle East
+353 61 225 977
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
MODEL
2
3
OUTPUT 2
Vo nom
Io max
Vo nom
Io max
VDC
ADC
VDC
85 – 264
32
46.9
5
FXP1500-32G
1
OUTPUT 1
INPUT VOLTAGE
VAC
AUTO SELECTED 1
COMPATIBLE
SHELF 2
ADC
RATED
POWER
W
1
1505 3
FXR-3-32G
The available output power is automatically adjusted depending on the input voltage.
1U standard rack FXR-3-32G for FXP1500-32G is available from Bel Power Solutions.
Automatic derating of main output below 108 VAC to: Io max = 37.5 A (1200 W).
Stress in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability,
or cause permanent damage to the converter.
PARAMETER
Input voltage
CONDITIONS/DESCRIPTION
MIN
MAX
UNIT
264
300
VAC
VAC
0
70
°C
-40
85
°C
Continuous Transient, 60 ms max.
Vi min-Vi max, Io nom, cooling by internal fan
Operating ambient temperature
100 % load from 0 to 50°C
linear derating to 50% load from 50°C to 70°C
Storage temperature
Non-Operating
Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated.
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNIT
Input Voltage
85
230
264
VAC
Input Frequency
47
50/60
63
Hz
Turn-On Input Voltage
Ramping up
79
-
85
VAC
Turn-Off Input Voltage
Ramping down
70
-
78
VAC
Inrush Current Limitation
115/230 VAC acc. ETS 300 132-1
< 100 ms
50
Apk
Hold-Up Time
After last AC line peak ,Vi = 230 VAC, Po nom
Power Factor
Vi nom, Io nom
Efficiency
Vi = 230 VAC, Vo nom, Io nom, Tc=25°C
20
ms
0.95
W/VA
89
Max Input Current
89.5
%
20
Arms
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated.
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Total Output Voltage Range
Adjustable via T4, T5 pins & I2C
26
NOM
Adjustable via I2C from any set point.
Note: all changes to Vo1 made via I2C are volatile and are lost
upon power cycling the PSU
28V set point
32V set point
36V set point
Io1 nom @ Vi =105 VAC – 264 VAC, Po 1.5 kW
28V set point
32V set point
36V set point
Output Voltage Trimming
Overvoltage Protection Latching
UNITS
38
VDC
VDC
VDC
VDC
+2
VDC
28
32
36
Adjustable via T4, T5 pins
(LL = 28 V, LH = HL = 32 V, HH = 36 V)
Output Voltage Set Point
MAX
-2
35
40
45
VDC
VDC
VDC
46.9
46.9
41.7
ADC
ADC
ADC
42.9
37.5
33.4
1.0
48.8
50.8
39.0
41.0
1.3
ADC
ADC
ADC
ADC
ADC
ADC
ADC
ADC
ADC
Nominal Current Output 1
Io1 nom @ Vi = 85 VAC – 105 VAC, Po 1.2 kW
28V set point
32V set point
36V set point
Nominal Current Output 2
Io2 nom @ Vi = 85 VAC – 265 VAC, Po 5 W
Io1 max @ Vi = 105 VAC – 264 VAC high droop
hic-cup
Current Limit Output 1
Io1 max @ Vi = 85 VAC – 105 VAC high droop
hic-cup
Current Limit Output 2
Io2 max @ Vi = 85 VAC – 265 VAC
Static Line Regulation Output 1
Vi min - Vi max, 50 % Io nom
Vi = 230 V, 0-100 % Io nom Vo : full
load (46.9 ADC) to no load
Static Load Regulation Output 1
(Droop Characteristic)
-0.5
31.68
-1.0
Load change 1 % <─> 100 % Io nom, dIo/dt =1 A/µs
Voltage deviation (droop + over- or undershoot)
Max. recovery time to within 1 % of Vo1 nom
Time required for output within regulation
after initial application of AC-input (Vi nom, Io nom)
after removal of inhibit (Vi nom, Io nom)
Vi nom, Io nom, 20 MHz bandwidth
Vo1
Vo2
Total compensation for cable losses
Difference in current between two units for Vo1 above 10 %
load. Active current share pin with its 1kΩ internal impedance
enables control of output voltage. Voltage on this pin is
proportional to output current, 2V at Io1 nom
Dynamic Load Regulation
Start-Up Time
Output Voltage Ripple & Noise
Remote Sense
Active Current Share
PARAMETER
CONDITIONS/DESCRIPTION
Input Fuse
Not user accessible
-4
+4
2000
% Vo nom
µs
1.5
s
ms
320
50
500
mVpp
mVpp
mV
5
ADC
MIN
NOM
MAX
UNIT
25AF
with NTCs
Output
Over-Temperature Protection
% Vo nom
mV/A
VDC
% Vo nom
100
Inrush Current Limitation
Overvoltage Protection Latching
32
0.5
13.6
32.32
+1.0
No-load, short circuit, and overload proof
1
Absolute
40
V
Automatic power shutdown at TC
95
°C
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
PARAMETER
TYPE 4
Visual Status Indication
FP
I2C Communication Bus
OC[S1, S2]
CONDITIONS/DESCRIPTION
•
•
•
DC OK (green)
AC OK (green)
Fan fail & Over-temperature (amber)
• Monitors alarm functions and allows control of specific parameters.
• Uses standard Philips two wire bus (SCL and SDA signal lines)
LED indicators 5
2
I C Communication Bus
Addressing
PS Present Pin
PS Main Output Remote
Shutdown
Power Supply OK
DC Current Fail
OC[T1-T3]
OC[U3]
OC[R1]
FP
I2C
2
IC
AC Fail / Power Down
Warning
OC[U2] & I2C
DC fail / Output Voltage Fault
OC[U4] & I2C
Critical Temperature
Warning/Fan Fail
OC[U1] & I2C
DC Voltage Monitoring
I2C
DC Current Monitoring
I2C
Active Current Share
Interconnect
VO1 Presets
OC[R4]
OC[T4,T5]
VO1 Voltage Trimming
(Margining)
I2C
Fan Speed Control
I2C
Fan OK/FAIL
Synchronized Startup Pin
4
5
OC[U1] & I2C
OC[R5]
Three lines provide up to 8 separate PSU I2C addresses
• Used by system to indicate a PSU is installed in a system shelf
• Contact closure to logic ground ( internal pull-down resistor of 1 kΩ)
• TTL compatible signal, inhibited when open contact, high or at TTL logic “1”
• Signal referenced to logic return (LRTN)
Two position switch in series with OC signal (logical AND) allows local enable/disable;
“0” Position => PS disabled; “1” Position => PS Enabled
AC OK & DC OK & no overcurrent & no over-temperature & fans working
Reports over-current condition on main output, IO1
Provides a warning that the input power has failed at least 5 ms before the output falls
out of regulation (<90% VO1 set).
• Open collector signal with 20 mA pull-down capability, referenced to logic return
(LRTN).
• AC fail will go high or open during power fail condition and will go low when input is
within the operating range.
• A Power Fail warning will turn off the front panel green AC OK LED.
Internal under-voltage and overvoltage supervision of VO1.
• Open collector signal with 20 mA pull-down capability, referenced to logic return
(LRTN).
• DC fail will go high or open if Vo1 < 90% or VO1> 110% of VO1 set, measured in front
of the ORing FETs.
• Green LED on the front panel indicates normal operation; LED will flash if in parallel
operation VO1 is OK, but the unit is disabled.
Indicates the PSU operating temperature has reached [Tshut-down – 10K] Indicates if the
unit is in over-temperature shutdown.
• Open collector signal with 20 mA pull-down capability, referenced to logic return
(LRTN).
• The OC-output will go low 100 ms before an over-temperature condition shuts
down the unit.
• An amber LED on the front panel indicates over-temperature or fan fail.
Monitors the main output voltage, VO1, seen at the output connector.
Accuracy is ±1% over setting range and temperature.
Monitors the output current IO1 : Accuracy ± 1% over the load range.
Line must be connected to all paralleled PSUs to allow active current share functionality
between units
Output voltage is preset per programming of T4, T5
• T4/T5 = LOW / LOW => VO1=28VDC
• T4/T5 = LOW / HIGH = HIGH / LOW => VO1=32VDC
• T4/T5 = HIGH / HIGH => VO1=36VDC
Output voltage trimming Vo1: ±2 VDC
Setting accuracy over I2C: ± 50mV at VO1nom, ± 150 mV over setting range
Two fan speed levels automatically set depending on the internal temperature. The fan
speed can be set to full speed or automatic control via I2C command.
Indicates if the cooling fans are operating or have failed.
Overcurrent signal which can be used for synchronous startup of units in parallel or to
recover from an overload condition.
Abbreviations used:
OC[#] => Hardwired signal accessible at PSU output connector, with pin number reference
FP
=> Provided by devices located on PSU Front panel
I2C
=> Signal provided over I2C communication system.
Detailed I2C information is available from the specific model’s I2C Manual found on the Bel Power Solutions web site.
See LED Function table for further details
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
PARAMETER
Altitude
Relative Humidity,
Non-Condensing
Temperature Coefficient
Shock
Sinusoidal Vibration
Random Vibration
MTBF
CONDITIONS/DESCRIPTION
Operating
Non-Operating
Operating
Storage
0 °C to 70 °C (after 15 min warm-up)
IEC/EN 60068-2-27, 11 ms
IEC/EN 60068-2-6
2-8 Hz
8-200 Hz
200-500 Hz
10-2000 Hz
Calculated per Bellcore (SR-332, Issue 1):
GB 25°C
Demonstrated
MIN
NOM
10
5
MAX
10 k
40 k
90
95
0.02
40
7.5
2
4
6.15
UNIT
ASL Ft.
ASL Ft.
% RH
% RH
%/K
gpk
mil
gpk
gpk
grms
230
250
kh kh
Maximum electric strength testing is performed in the factory according to EN50514, IEC/EN60950-1 2nd ed. and
UL/CSA60950-1 2nd ed. Input-to-output electric strength tests should not be repeated in the field. Bel Power Solutions will
not honor any warranty claims resulting from electric strength field tests.
PARAMETER
Agency Approvals
Insulation Safety Rating
Electric Strength Test Voltage
6
CONDITIONS/DESCRIPTION
MIN
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1;
CE Mark for LVD
Input to case
Input to output
Output to case
Input to case
Input to output
Output to case
Output 1 to output 2
NOM
MAX
UNIT
Basic
Reinforced
Functional
2.121
Note 6
0.1
0.1
kVDC
kVDC
kVDC
kVDC
Subassemblies are pre-tested with 4.2 kVDC in accordance with EN50514 and IEC/EN60950-1 2nded.
PARAMETER
DESCRIPTION
Electrostatic Discharge
IEC/EN 61000-4-2, level 4 (contact/air)
Electromagnetic Field
IEC/EN 61000-4-3, level 3
10 V/m, Performance criterion A
Electrical Fast Transients/Burst
IEC/EN 61000-4-4, level 3 (L/L, L/E)
2 / 1 kV, Performance criterion B
Surge
IEC/EN 61000-4-5, level 3 (L/L, L/E)
IEC/EN 61000-4-11
Dip 30 %, 100 ms
Dip 30 %, 200 ms
Dip 60 %, 20 ms
Dip 60 %, 100 ms
Dip > 95 %, 20 ms
Dip > 95 %, 100 ms
1 / 2 kV, Performance criterion B
Voltage Dips & Interruptions
CRITERION
8/15 kV, Performance criterion B
Performance criterion A
Performance criterion B
Performance criterion A
Performance criterion B
Performance criterion A
Performance criterion B
10 VAC, AM 80 %, 1 kHz
Performance criterion A
Class B
RF Conducted Immunity
IEC/EN 61000-4-6
Emissions Conducted
CISPR 22/EN 55022/EN 61204
Emissions Radiated
CISPR 22/EN 55022/EN 61204
Class A
Harmonics
IEC/EN 61000-3-2
Class B
Voltage Fluctuation & Flicker
Voltage Sag
IEC/EN 61000-3-3
Pass
SEMI F47-0200 (High Line 230V)
Pass
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
OUTPUT CONNECTOR
DESCRIPTION
TYPE
SIGNAL
REFERENCE
OC-output, protected by 16 V Zener diode
and a 10Ω resistor in series
LGND
1KΩ Resistor connected to logic GND
LGND
OC PIN #
Over-temperature / Fan Fail
U1
AC Fail /
Power Down Warning
U2
Power Supply Present
U3
DC Fail /
Output Voltage Fault
U4
Internal Ground (INT GND)
U5
ADDR0 I2C Address Bus
T1
ADDR1 I2C Address Bus
T2
ADDR2 I2C Address Bus
T3
OC-output, protected by 16 V Zener diode
and a 10Ω resistor in series
Used only for ADDRx and VO1 set. Do not
connect the internal grounds in systems
with several units.
LOW LEVEL
HIGH LEVEL
<0.4 V @ 20 mA
Pull up
<0.4 V @ 20 mA
Pull up
Open
Pull up
<0.4V @ 20 mA
Pull up
V MAX
I MAX
15 V
20 mA
15 V
20 mA
10 V
10 mA
15 V
20 mA
Connected to
VO1 - line before
the output filter
-
-
INT GND
Logic 1
Logic 0
5V
0V
LGND
Logic 1
Logic 0
5V
0V
Aux output is
floating
-
-
-
-
-
LGND
<0.8 V
>2.0 V
-
-
-
-
10 V
3.5 mA
dV<3 Vpp
30 mA
dV<3 Vpp
30 mA
-
-
LGND
High = internal 10 KΩ PU to 5V=> Logic 1
Low = connect to INT GND => Logic 0
VO1 set
T4
VO1 set
T5
SDA, I2C Serial Data Line
S1
SCL, I2C Serial Clock Line
S2
I2C compatible signal referenced to logic
GND 5 V or 3.3 V logic
Auxiliary Power +5 V
S3
VO2+ output, isolated from main output
Auxiliary Power +5 VRTN
S4
Logic Ground (LGND)
S5
Output Inhibit R1
R1
V Sense +
R2
V Sense -
R3
Active Current Share
R4
Synchronized Startup
(for paralleled units)
R5
Aux output return; ground isolated from
main output
Internally connected to Aux GND through
10Ω resistor. Wire LGND separately from
Aux RTN and main output GND to minimize
noise on signals and I2C bus.
Leave open if not used.
PS active when pulled low
(DC-DC stage off when left open)
Open or connected toVO1+ at the load
Internally connected to VO1+ via 100 Ω.
Open or connected toVO1- at the load
Internally connected to VO1- via 100 Ω.
This pin must be interconnected to pin R4
of all other paralleled PSUs for proper
operation of active current share function
Open or connected to synch startup circuit
2V
12V
2mA
VO1 - at the OC
VO1-
P1, P3, P5
Main output - pins
-
-
-
VO1+
P2, P4, P6
Main output + pins
-
-
-
INPUT CONNECTOR
DESCRIPTION
OC PIN #
TYPE
Protection Earth
P1
PE
Phase
P2
L
Neutral
P3
N
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
CONDITION
FAN FAIL AND
OVER - TEMPERATURE
POWER FAIL (AC OK)
OUTPUT GOOD (DC OK)
Normal Operation
Green
Green
OFF
Power Supply is Inhibited
Green
OFF
Amber
OFF
OFF
Amber
Input AC is Low
Input AC is Low or Missing
OFF
OFF
Amber/OFF
Over-Temperature
Green
OFF
Amber
Output Overload (In regulation)
Green
Green
OFF
Output Overloaded (Out of Regulation)
Green
OFF
OFF
Fan Not Running
Green
OFF
Amber
OFF
OFF
OFF/ Amber
Power Supply Failed
Mechanical Dimensions (W x H x D):
5.6” (141.2 mm) x 1.6” (40.5 mm) x 12” (304.8 mm)
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
Female ledge connector:
Manufacturer: FCI
Output connector Part No.: 51762-106020000AA LF (Horizontal)
Output connector Part No.: 51742-106020000AA LF (Vertical)
Input connector Part No.: 51915-056LF (Horizontal)
Input connector Part No.: 51940-099LF (Vertical)
Information on availability under http://www.stkcheck.com/evs/fcielectronics/fcisearch.asp
Paralleling Front-Ends
For parallel use in minimal configuration systems, only the inhibit pins must be shorted to logic GND. All other pins can be
left open. The power supplies will share the output current automatically (droop current share).
For parallel applications without I2C bus, but the use of all other features, it is recommended to connect all logic GND’s on a
backplane together, to connect all Vo2 -, all V o2 + and to leave the internal GND’s open.
The sense wires can be left open or connected to a common load point, the synch-start pin can be left open or connected to
a synch-start circuit, the inhibit pins can be connected together or used individually. All I2C signals (T1-T5, S1, and S2) can
be left open.
Use of a small foil capacitor > 3µF directly at the power outputs of each unit is recommended in order to prevent voltage
drops at the hot plug. For additional information on paralleling see the following Rack (Power Shelf) section.
To achieve best cooling results sufficient airflow through the unit must be ensured. Do not block or obstruct the airflow at the
rear of the unit by placing large components directly at the output connector.
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
•
•
•
•
•
•
•
Each rack (power shelf) is 1U high with backplane and designed for up to three front-end models in parallel or in n+1
operation. Each power shelf has:
Generous copper bus bars for low-loss current distribution.
Output terminals with two M4-screws on each power tab.
Two fast-on contacts for system earthing.
Address coding over five pole DIP switch on each unit, 37-pin D-Sub connector with I2C-lines, monitoring signals and
support functions.
Provides a start-up synchronization circuit and EMV filters.
Overall Mechanical Dimensions (W x H x D): 17.7” (449.6 mm) x 1.7” (43.1 mm) x 14” (355.6 mm)
FXR-3-32G Power Shelf Front View
A
LOCATION
B
PE3
PE2
PE1
L3 N3
L2 N2
L1 N1
C
D
E
F
G
H
I
J
DESCRIPTION
A
Earth connection
B
5-bit DIP switch, pins 1,2,3 for I2C addressing and pins 4,5 for Vo setting of PSU #3
C
Mains connector of PSU #3
D
Output 1 Minus
E
Output 1 Plus
F
5-bit DIP switch, pins 1,2,3 for I2C addressing and pins 4,5 for Vo setting of PSU #2
G
Mains connector of PSU #2
H
37-pin SUB-D connector, control, sense, check and Auxiliary power (Output 2)
I
5-bit DIP switch, pins 1,2,3 for I2C addressing and pins 4,5 for Vo setting of PSU #1
J
Mains connector of PSU #1
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
OUTPUT CONNECTOR
DESCRIPTION
Over-temperature /
Fan Fail PSU1
Power Supply
Present PSU 1
Power Supply
Present PSU 2
Spare
Over-temperature /
Fan Fail PSU 3
AC Fail /
Power down warning PSU 3
Power Supply Present
PSU 3
DC Fail /
Output voltage fault PSU 3
Overtemperature /
Fan Fail PSU 2
OC PIN
TYPE
SIGNAL
REFERENCE
1
OC-output, protected by 16 V Zener diode and
a 10 Ω resistor in series
LGND
V MAX
I MAX
15 V
20 mA
Resistor (1 kΩ) connected to LGND
LGND
Open
Pull up
10 V
10 mA
OC-output, protected by 16 V Zener diode and
a 10 Ω resistor in series
LGND
<0.4 V @ 20 mA
Pull up
15 V
20 mA
Resistor (1 kΩ) connected to logic
GND
LGND
Open
Pull up
10 V
10 mA
OC-output, protected by 16 V Zener diode and
a 10 Ω resistor in series
LGND
<0.4 V @ 20 mA
Pull up
15 V
20 mA
Sync_start_A , Active high
The signals of several racks can be connected
together in such a way that all supplies will be
inhibited until the last supply has recovered
from its overcurrent condition
LGND
<7V off < 9V
15V
10mA
LGND
<0.8 V
>2.0 V
10 V
3.5 mA
2
3
4
5
6
7
8
9
Synch._Start_A
10
Open
11
Output inhibit
PSU 1-3
12
V sense +
13
V sense -
14
Open
15
NC
16
NC
17
NC
18
NC
19
AC Fail/
Power-down warning PSU 1
DC Fail/
Output voltage fault PSU 1
AC Fail/
Power-down warning PSU 2
DC Fail/
Output voltage fault PSU 2
LOW LEVEL
HIGH LEVEL
<0.4 V @ 20 mA
Pull up
DC-DC stage ON when pin is open or
connected to LGND
DC-DC stage OFF when pin is connected on
high potential
Open or connected to VO1+ at the load
Internally (PSU) connected to VO1+ over 100 Ω
Open or connected to VO1- at the load
Internally (PSU) connected to VO1- over 100 Ω
dV < 3 Vpp
30 mA
dV < 3 Vpp
30 mA
VO1+
VO1-
20
21
22
OC-output, protected by 16 V Zener diode and
a 10 Ω resistor in series
LGND
<0.4 V @ 20 mA
Pull up
23
SDA, I2C data line
24
I2C compatible signal
LGND
5 V or 3.3 V logic
SCL, I2C clock line
25
I2C compatible signal
LGND
5 V or 3.3 V logic
26
VO2+ Aux output, insulated from main output
27
VO2- Aux output, insulated from main output
VO2+ = +5 V (Auxiliary
power)
VO2- = +5 VRTN (Auxiliary
power)
15 V
20 mA
Aux output is
isolated supply
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
Logic Gnd (LGND)
28
Active curretnt share
29
NC
30
NC
31
NC
32
NC
33
NC
34
Internal Ground PSU1
35
Internal Ground PSU2
36
Internal Ground PSU3
37
Wire separately from auxiliary and main output
GND to minimize noise and avoid voltage drops
on signal- and I2C return. Leave open if not
used.
This pin must be interconnected to all other
parallel shelfs for proper operation of active
current share function.
Internally
connected to
VO2- Auxiliary
GND via 10 Ω
2V
Used only for ADDRx and VO1 set. Do not Connected to
connect the internal grounds in the system with VO1- line before
several units.
the output filter
The FXP1500-32G power supply exhibit an overcurrent hiccup behavior. This means if either of these supplies reaches an
overcurrent limit, the output voltage will immediately turn OFF and after a delay turn ON again. In parallel use, all power
supplies have to start synchronized because of the internal hiccup behavior. Otherwise, the supply which has reached
overcurrent first will go to hiccup; this will overload the other supplies, which then will also go to hiccup. When the first
supply has recovered from hiccup (hiccup dead time), the others remain in hiccup. This will immediately drive the first one
into hiccup once again. This means that without a start-up circuit, a system with several power supplies can never recover
from an overload condition or start-up into full load.
The following additional circuit, required to reach synchronized startup, is already implemented inside the FXR-3-32G shelf.
The following connection between the shelves is required to achieve a parallel operation. The synch-start circuits inside the
shelves inhibit all power supplies until the last one has recovered from its overcurrent condition and then synchronize the
restart of the outputs.
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
DESCRIPTION
PIN
LOCATION,
DEFINITION
SIGNAL
REFERENCE
TYPE
Auxiliary power +5 V
(Output 2)
26
VO2+, Aux output, insulated from main output
Logic ground
28
Logic_GND , Internally connected over 10 Ω to
VO2-, (Auxiliary power ground (Output 2))
Output inhibit_A PSU
1-3
Synch. Startup 1
PSU 1-3
Synch. Startup_A
Rack FXR-3-32G 1-N
Pin on the D-Sub
connector on the
backplane
12
R5
(at PSU OC)
10
Inhibit_A,
DC-DC stage ON when pin is open or connected
to LGND
DC-DC stage OFF when pin is connected on high
potential
The synch_start pin is connected to the overcurrent signal of the PSU1-3. In the case of an
overcurrent shutdown, this signal goes high.
Sync_start_A, Active high The signals of several
racks can be connected together in such a way
that all supplies will be inhibited until the last
supply has recovered from its overcurrent
condition.
LOW LEVEL
HIGH LEVEL
V MAX
I MAX
LGND
<0.8 V
>2.0 V
10 V
3.5 mA
Vo1-
<7V off > 9V
15V
10mA
Internally
connected over
10 Ω to VO2-
LGND
NOTE: The Sync-Start pins can be wired together only if the power supplies are connected with a minimal voltage drop on power ground
as achieved on a backplane with massive copper bus bars. If there is a less ideal connection, it is recommended to use an opto-coupler for
each unit (IC1, D3, D2).
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
Center Angular Brackets are set in the middle for shelf mounting:
Center Angular Bracket sets can be ordered: Bel Power Solutions part no.: HZZ01222
Note: Each Center Angular Bracket set contains 2 brackets and 8 screws.
Filler for covering of the empty shelf slots
Filler can be ordered: Bel Power Solutions part no.: XAK.00043.0
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
Plastic cover set for the bus bars:
Plastic cover set can be ordered: Bel Power Solutions part no.: XEB.00031.0
Note1: Available upon special request.
Note2: Each plastic cover set contains 2pcs.
The handle has been designed to allow easy plug-in and -out in a rack system. The handle (lever) fits into a counter piece
(fulcrum) which is fixed to the bottom of the rack. During the plug, the fulcrum holds the unit down and guides it towards
the output connector. The Bel Power Solutions part number of the fulcrum and its associated mounting accessories is:
HZZ01223.
Individual fulcrum sets can be also ordered: Bel Power Solutions part no.: HZZ01223.
Note: Each HZZ01223 set contain 2 fulcrums, 2 supports, and mounting accessories.
+1.866.513.2839
[email protected]
© 2015 Bel Power Solutions, Inc.
BCD.00021_AB
FXP1500-32G
I2C <to>USB
Interface
I2C Management Software: All FNP and FXP front-ends can be controlled via Bel Power Solutions GUI-driven I2C
Management software and an I2C-to-USB interface (P/N HZZ02002G). An I2C Programming Manual describes the complete
range of parameters that can be programmed to the FXP1500/1800 front-ends. This manual is available by searching on
"FXP1500" at www.belpowersolutions.com.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support
systems, equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending
on the date manufactured. Specifications are subject to change without notice.