ON NCP1342DADBDD1R2G High frequency quasi-resonant flyback controller Datasheet

NCP1342
High Frequency QuasiResonant Flyback Controller
The NCP1342 is a highly integrated quasi−resonant flyback
controller suitable for designing high−performance off−line power
converters. With an integrated active X2 capacitor discharge feature,
the NCP1342 can enable no−load power consumption below 30 mW.
The NCP1342 features a proprietary valley−lockout circuitry,
ensuring stable valley switching. This system works down to the 6th
valley and transitions to frequency foldback mode to reduce switching
losses. As the load decreases further, the NCP1342 enters quiet−skip
mode to manage the power delivery while minimizing acoustic noise.
To ensure light load performance with high frequency designs, the
NCP1342 incorporates Minimum Peak Current Modulation (MPCM)
to reduce the switching frequency quickly. To help ensure converter
ruggedness, the NCP1342 implements several key protective features
such as internal brownout detection, a non−dissipative Over Power
Protection (OPP) for constant maximum output power regardless of
input voltage, a latched overvoltage and NTC−ready overtemperature
protection through a dedicated pin, and line removal detection to safely
discharge the X2 capacitors when the ac line is removed. If transient
load capability is desired, the NCP1343 offers the same performance
and features with the addition of power excursion mode (PEM).
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Integrated High−Voltage Startup Circuit with Brownout Detection
Integrated X2 Capacitor Discharge Capability
Wide VCC Range from 9 V to 28 V
28 V VCC Overvoltage Protection
Abnormal Overcurrent Fault Protection for Winding Short Circuit or
Saturation Detection
Internal Temperature Shutdown
Valley Switching Operation with Valley−Lockout for Noise−Free
Operation
Frequency Foldback with 25 kHz Minimum Frequency Clamp for
Increased Efficiency at Light Loads
MPCM for Fast Reduction of Switching Frequency at Light Loads
Skip Mode with Quiet−Skip Technology for Highest Performance
During Light Loads
Minimized Current Consumption for No Load Power Below 30 mW
Frequency Jittering for Reduced EMI Signature
Latching or Auto−Recovery Timer−Based Overload Protection
Adjustable Overpower Protection (OPP)
Adjustable Maximum Frequency Clamp
Fault Pin for Severe Fault Conditions, NTC Compatible for OTP
4 ms Soft−Start Timer
© Semiconductor Components Industries, LLC, 2017
December, 2017 − Rev. 1
1
www.onsemi.com
8
9
1
1
SOIC−9 NB
D SUFFIX
CASE 751BP
SOIC−8 NB
D SUFFIX
CASE 751
MARKING DIAGRAMS
8
9
1342abcde
ALYW
G
1
1342abcde
ALYW
G
1
1342abcde = Specific Device Code
A
= Assembly Location
L
= Wafer Lot
Y
= Year
W
= Work Week
G
= Pb−Free Package
PIN CONNECTIONS
1
HV
Fault
FMAX
FB
ZCD/OPP
CS
VCC
DRV
GND
1
HV
Fault
FB
VCC
ZCD/OPP
DRV
GND
CS
(Top Views)
ORDERING INFORMATION
See detailed ordering and shipping information on page 3 of
this data sheet.
Publication Order Number:
NCP1342/D
NCP1342
TYPICAL APPLICATION SCHEMATIC
+
+
Vout
NCP1342
HV
Fault
+
L
N
VCC
FB
EMI
Filter
ZCD/OPP DRV
CS
GND
−tº
+
Figure 1. NCP1342 8−Pin Typical Application Circuit
+
NCP1342
+
L
N
Fault
FMAX
FB
EMI
Filter
HV
VCC
ZCD/OPP DRV
CS
GND
−tº
+
Figure 2. NCP1342 9−Pin Typical Application Circuit
www.onsemi.com
2
+
Vout
NCP1342
Table 1. PART NUMBER DECODE − NCP1342ABCDEFR2G
NCP1342
A
B
C
D
E
F*
OTP/Overload
Jitter Frequency/Amplitude
Quiet−Skip
CS Min
MPCM
Pins
A − AR/AR
A − 1.55 kHz/75 mV
A − 800 Hz
A − 200 mV
A − 400 mV
D − 8 Pins
B − Latch/AR
B − 1.55 kHz/92 mV
B − 1.2 kHz
B − 150 mV
B − 350 mV
D1 − 9 Pins
C − AR/Latch
C − 1.55 kHz/55 mV
C − 1.56 kHz
C − 100 mV
C − 300 mV
D − Latch/Latch
D − 1.55 kHz/61 mV
D − Disabled
D − 250 mV
D − 250 mV
E − 1.3 kHz/75 mV
E − Disabled
F − 1.3 kHz/92 mV
Device
R2G*
Pb
Free
G − 1.3 kHz/55 mV
H − 1.3 kHz/61 mV
J − 3.9 kHz/75 mV
K − 3.9 kHz/92 mV
L − 3.9 kHz/55 mV
M − 3.9 kHz/61 mV
N − Disabled
*In OPN only − not on device marking
Table 2. ORDERING INFORMATION
Device Marking
Package
NCP1342BLACADR2G
Part Number
1342BLACA
SOIC−8 NB (Pb−Free)
NCP1342AMDAAD1R2G
1342AMDAA
NCP1342DADBDD1R2G
Shipping
2500 / Tape & Reel
SOIC−9 NB (Pb−Free)
1342DADBD
www.onsemi.com
3
NCP1342
FUNCTIONAL BLOCK DIAGRAM
TSD
IFMAX
VDD
FMAX
Control
FMAX
QR_FMAX
BO
X2
Abnormal OCP
OVLD
OVP
OTP
Fault
Management
Fault
Off−Time
Control
ZCD/OPP
Dead−Time
Control
OPP
Control
OPP
FB
R FB
VCC
t tout
QR_FMAX
VFB(open)
HV
VCC
Valley/FF
Control
FB
VCC(OVP)
X2/BO Detect
+
VCC
Management
Jitter Ramp
Clamp
Quiet−Skip
Control
S
K FB
Q
DRV
R
GND
÷
MPCM
Control
FB
On−Time
Control
V DD
Fault
ICS
V DD
OVP
ILIM1
Detect
t LEB1
CS
t OVLD
OVLD
OTP
OVP/OTP
Detect
IOTP
FB
Fault
RFault(clamp)
OPP
t LEB2
ILIM2
Detect
8−Pin
9−Pin
V Fault(clamp)
Abnormal OCP
Count 4
Figure 3. NCP1342 Block Diagram
Table 3. PIN FUNCTIONAL DESCRIPTION
8−Pin
9−Pin
Pin Name
1
1
Fault
The controller enters fault mode if the voltage on this pin is pulled above or below the fault
thresholds. A precise pull up current source allows direct interface with an NTC thermistor.
Function
−
2
FMAX
A resistor to ground sets the value for the maximum switching frequency clamp. If this pin is
pulled above 4 V, the maximum frequency clamp is disabled.
2
3
FB
3
4
ZCD/OPP
4
5
CS
5
6
GND
Ground reference.
6
7
DRV
This is the drive pin of the circuit. The DRV high−current capability (−0.5 /+0.8 A) makes it suitable to effectively drive high gate charge power MOSFETs.
7
8
VCC
This pin is the positive supply of the IC. The circuit starts to operate when VCC exceeds 17 V and
turns off when VCC goes below 9 V (typical values). After start−up, the operating range is 9 V up
to 28 V.
−
9
N/C
Removed for creepage distance.
8
10
HV
This pin is the input for the high voltage startup and brownout detection circuits. It also contains
the line removal detection circuit to safely discharge the X2 capacitors when the line is removed.
Feedback input for the QR Flyback controller. Allows direct connection to an optocoupler.
A resistor divider from the auxiliary winding to this pin provides input to the demagnetization detection comparator and sets the OPP compensation level.
Input to the cycle−by−cycle current limit comparator.
www.onsemi.com
4
NCP1342
Table 4. MAXIMUM RATINGS
Rating
Symbol
Value
High Voltage Startup Circuit Input Voltage
VHV(MAX)
−0.3 to 700
V
High Voltage Startup Circuit Input Current
IHV(MAX)
20
mA
Supply Input Voltage
VCC(MAX)
−0.3 to 30
V
Supply Input Current
ICC(MAX)
30
mA
Supply Input Voltage Slew Rate
dVCC/dt
1
V/ms
Fault Input Voltage
VFault(MAX)
−0.3 to VCC + 0.7 V
V
Fault Input Current
IFault(MAX)
10
mA
Zero Current Detection and OPP Input Voltage
VZCD(MAX)
−0.3 to VCC + 0.7 V
V
Zero Current Detection and OPP Input Current
IZCD(MAX)
−2/+5
mA
VMAX
−0.3 to 5.5
V
Maximum Input Voltage (Other Pins)
Unit
Maximum Input Current (Other Pins)
IMAX
10
mA
Driver Maximum Voltage (Note 1)
VDRV
−0.3 to VDRV(high)
V
IDRV(SRC)
IDRV(SNK)
500
800
mA
TJ
−40 to 125
°C
TSTG
–60 to 150
°C
Driver Maximum Current
Operating Junction Temperature
Storage Temperature Range
Power Dissipation (TA = 25°C, 1 oz. Cu, 42
DR2G Suffix, SOIC−8
D1R2G Suffix, SOIC−9
mm2
Copper Clad Printed Circuit)
PD(MAX)
mW
450
330
Thermal Resistance (TA = 25°C, 1 oz. Cu, 42 mm2 Copper Clad Printed Circuit)
DR2G Suffix, SOIC−8
D1R2G Suffix, SOIC−9
ESD Capability
Human Body Model per JEDEC Standard JESD22−A114F (All pins except HV)
Human Body Model per JEDEC Standard JESD22−A114F (HV Pin)
Charge Device Model per JEDEC Standard JESD22−C101F
Latch−Up Protection per JEDEC Standard JESD78E
RqJA
°C/W
225
300
2000
800
1000
±100
V
V
V
mA
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. Maximum driver voltage is limited by the driver clamp voltage, VDRV(high), when VCC exceeds the driver clamp voltage. Otherwise, the
maximum driver voltage is VCC.
www.onsemi.com
5
NCP1342
Table 5. ELECTRICAL CHARACTERISTICS: (VCC = 12 V, VHV = 120 V, VFault = open, VFB = 2.4 V, VCS = 0 V, VZCD = 0 V, VFMAX
= 0 V, CVCC = 100 nF , CDRV = 100 pF, for typical values TJ = 25°C, for min/max values, TJ is – 40°C to 125°C, unless otherwise noted)
Characteristics
Conditions
Symbol
Min
Typ
Max
VCC(on)
17.0
18.0
9.0
–
6.5
0.70
18.0
19.0
9.5
–
7.5
1.05
Unit
START−UP AND SUPPLY CIRCUITS
Supply Voltage
Startup Threshold
Discharge Voltage During Line Removal
Minimum Operating Voltage
Operating Hysteresis
Internal Latch / Logic Reset Level
Transition from Istart1 to Istart2
dV/dt = 0.1 V/ms
VCC increasing
VCC decreasing
VCC decreasing
VCC(on) − VCC(off)
VCC decreasing
VCC increasing, IHV = 650 mA
VCC(X2_reg)
VCC(off)
VCC(HYS)
VCC(reset)
VCC(inhibit)
16.0
17.0
8.5
7.5
4.5
0.30
VCC(off) Delay
VCC decreasing
tdelay(VCC_off)
25
32
40
ms
Startup Delay
Delay from VCC(on) to DRV Enable
tdelay(start)
–
–
500
ms
VHV(MIN)
–
–
40
V
Vcc = 0 V
Istart1
0.2
0.5
0.65
mA
Vcc = Vcc(on) – 0.5 V
Istart2
2.4
3.75
5.0
mA
VHV = 162.5 V
VHV = 325 V
VHV = 700 V
IHV(off1)
IHV(off2)
IHV(off3)
–
–
–
–
–
–
15
20
50
mA
VCC = VCC(on) – 0.5 V
VFB = 0 V
fsw = 50 kHz, CDRV = open
ICC1
ICC2
ICC3
−
−
−
0.115
0.230
1.0
0.150
0.315
1.5
VCC(OVP)
27
28
29
V
tdelay(VCC_OVP)
25
32
40
ms
tline(removal)
65
100
135
ms
tline(discharge)
21
32
43
ms
tline(detect)
21
32
43
ms
ICC(discharge)
13
18
23
mA
VHV(discharge)
–
–
30
V
Minimum Voltage for Start−Up Current
Source
Inhibit Current Sourced from VCC Pin
Start−Up Current Sourced from VCC Pin
Start−Up Circuit Off−State Leakage Current
Supply Current
Fault or Latch
Skip Mode (excluding FB current)
Operating Current
V
mA
VCC Overvoltage Protection Threshold
VCC Overvoltage Protection Delay
X2 CAPACITOR DISCHARGE
Line Voltage Removal Detection Timer
Discharge Timer Duration
Line Detection Timer Duration
VCC Discharge Current
VCC = 20 V
HV Discharge Level
BROWNOUT DETECTION
System Start−Up Threshold
VHV increasing
VBO(start)
107
112
116
V
Brownout Threshold
VHV decreasing
VBO(stop)
93
98
102
V
Hysteresis
VHV increasing
VBO(HYS)
9.0
14
–
V
Brownout Detection Blanking Time
VHV decreasing
tBO(stop)
40
70
100
ms
Rise Time
VDRV from 10% to 90%
tDRV(rise)
–
20
40
ns
Fall Time
VDRV from 90% to 10%
tDRV(fall)
–
5
30
ns
IDRV(SRC)
IDRV(SNK)
–
–
500
800
–
–
GATE DRIVE
Current Capability
Source
Sink
mA
High State Voltage
VCC = VCC(off) + 0.2 V, RDRV = 10 kW
VCC = 30 V, RDRV = 10 kW
VDRV(high1)
VDRV(high2)
8.0
10
–
12
–
14
V
Low Stage Voltage
VFault = 0 V
VDRV(low)
–
–
0.25
V
2. NTC with R110 = 8.8 kW
www.onsemi.com
6
NCP1342
Table 5. ELECTRICAL CHARACTERISTICS: (VCC = 12 V, VHV = 120 V, VFault = open, VFB = 2.4 V, VCS = 0 V, VZCD = 0 V, VFMAX
= 0 V, CVCC = 100 nF , CDRV = 100 pF, for typical values TJ = 25°C, for min/max values, TJ is – 40°C to 125°C, unless otherwise noted)
Characteristics
Conditions
Symbol
Min
Typ
Max
Unit
VFB(open)
4.8
5.0
5.1
V
KFB
−
4
−
–
VFB = 0.4 V
RFB
17
20
23
kW
VFB decreasing
VFB decreasing
VFB decreasing
VFB decreasing
VFB decreasing
VFB increasing
VFB increasing
VFB increasing
VFB increasing
VFB increasing
V1to2
V2to3
V3to4
V4to5
V5to6
V6to5
V5to4
V4to3
V3to2
V2to1
1.316
1.128
1.034
0.940
0.846
1.410
1.504
1.598
1.692
1.880
1.400
1.200
1.100
1.000
0.900
1.500
1.600
1.700
1.800
2.000
1.484
1.272
1.166
1.060
0.954
1.590
1.696
1.802
1.908
2.120
VFMAX = 0.5 V
VFMAX = 3.5 V
fMAX1
fMAX2
440
61
500
70
560
79
9−Pin Versions Only
VFMAX(disable)
3.85
4.00
4.15
V
FEEDBACK
Open Pin Voltage
VFB to Internal Current Setpoint Division
Ratio
Internal Pull−Up Resistor
Valley Thresholds
Transition from 1st to 2nd valley
Transition from 2nd to 3rd valley
Transition from 3rd to 4th valley
Transition from 4th to 5th valley
Transition from 5th to 6th valley
Transition from 6th to 5th valley
Transition from 5th to 4th valley
Transition from 4th to 3rd valley
Transition from 3rd to 2nd valley
Transition from 2nd to 1st valley
V
Maximum Frequency Clamp
FMAX Disable Threshold
kHz
FMAX Pin Source Current
Maximum On Time
IFMAX
9.0
10
11
mA
ton(MAX)
28
32
40
ms
DEMAGNETIZATION INPUT
ZCD threshold voltage
VZCD decreasing
VZCD(trig)
35
60
90
mV
ZCD hysteresis
VZCD increasing
VZCD(HYS)
15
25
55
mV
VZCD step from 4.0 V to −0.3 V
tdemag
–
80
250
ns
IQZCD = 5.0 mA
IQZCD = −2.0 mA
VZCD(MAX)
VZCD(MIN)
12.4
−0.9
12.7
−0.7
13
0
tZCD(blank)
600
700
800
ns
While in soft−start
After soft−start complete
t(tout1)
t(tout2)
80
5.1
100
6.0
120
6.9
ms
Current Limit Threshold Voltage
VCS increasing
VILIM1
0.760
0.800
0.840
V
Leading Edge Blanking Duration
DRV minimum width minus
tdelay(ILIM1)
tLEB1
220
265
330
ns
Step VCS 0 V to VILIM1 + 0.5 V,
VFB = 4 V
tdelay(ILIM1)
–
95
175
ns
Step VCS 0 V to 0.7 V, VFB = 2.4
tdelay(PWM)
–
125
175
ns
170
115
70
215
200
150
100
250
230
185
130
285
Demagnetization Propagation Delay
ZCD Clamp Voltage
Positive Clamp
Negative Clamp
V
Blanking Delay After Turn−Off
Timeout After Last Demagnetization
Detection
CURRENT SENSE
Current Limit Threshold Propagation Delay
PWM Comparator Propagation Delay
Minimum Peak Current
Versions xxxAx
Versions xxxBx
Versions xxxCx
Versions xxxDx
VCS(MIN)
mV
Abnormal Overcurrent Fault Threshold
VCS increasing, VFB = 4 V
VILIM2
1.125
1.200
1.275
V
Abnormal Overcurrent Fault Blanking
Duration
DRV minimum width minus
tdelay(ILIM2)
tLEB2
80
110
140
ns
2. NTC with R110 = 8.8 kW
www.onsemi.com
7
NCP1342
Table 5. ELECTRICAL CHARACTERISTICS: (VCC = 12 V, VHV = 120 V, VFault = open, VFB = 2.4 V, VCS = 0 V, VZCD = 0 V, VFMAX
= 0 V, CVCC = 100 nF , CDRV = 100 pF, for typical values TJ = 25°C, for min/max values, TJ is – 40°C to 125°C, unless otherwise noted)
Characteristics
Conditions
Symbol
Min
Typ
Max
Unit
Step VCS 0 V to VILIM2 + 0.5 V,
VFB = 4 V
tdelay(ILIM2)
–
80
175
ns
nILIM2
–
4
–
tOPP(delay)
–
95
175
ns
tOPP(blank)
220
280
330
ns
ICS
0.7
1.0
1.5
mA
3.5
1.43
1.2
−
3.9
1.55
1.3
−
4.2
1.68
1.4
−
82
65
52
45
−
92
75
61
55
−
102
85
70
65
−
CURRENT SENSE
Abnormal Overcurrent Fault Propagation
Delay
Number of Consecutive Abnormal Overcurrent Faults to Enter Latch Mode
Overpower Protection Delay
VCS dv/dt = 1 V/ms, measured from
VOPP(MAX) to DRV falling edge
Overpower Signal Blanking Delay
Pull−Up Current Source
VCS = VILIM2 − 10 mV
JITTERING
Jitter Frequency
Versions xJxxx, xKxxx, xLxxx, xMxxx
Versions xAxxx, xBxxx, xCxxx, xDxxx
Versions xExxx, xFxxx, xGxxx, xHxxx
Versions xNxxx
fjitter
Peak Jitter Voltage
Versions xBxxx, xFxxx, xKxxx
Versions xAxxx, xExxx, xJxxx
Versions xDxxx, xHxxx, xMxxx
Versions xCxxx, xGxxx, xLxxx
Versions xNxxx
Vjitter
kHz
mV
FAULT PROTECTION
Measured from
1st DRV pulse to VCS = VILIM1
tSSTART
2.8
4.0
5.0
ms
VCS = VILIM1
tOVLD
120
160
200
ms
Overvoltage Protection (OVP) Threshold
VFault increasing
VFault(OVP)
2.79
3.00
3.21
V
OVP Detection Delay
VFault increasing
tdelay(OVP)
22.5
30
37.5
ms
Overtemperature Protection (OTP) Threshold (Note 2)
VFault decreasing
VFault(OTP_in)
380
400
420
mV
Overtemperature Protection (OTP) Exiting
Threshold (Note 2)
VFault increasing
Versions B Only
VFault(OTP_out)
880
910
940
mV
OTP Detection Delay
VFault decreasing
tdelay(OTP)
22.5
30
37.5
ms
VFault = VFault(OTP_in) + 0.2 V
TJ = 25°C to 125°C
IOTP
43.75
45.00
46.25
mA
Fault Input Clamp Voltage
VFault(clamp)
1.15
1.7
2.25
V
Fault Input Clamp Series Resistor
RFault(clamp)
1.32
1.55
1.78
kW
trestart
1.8
2.0
2.2
s
fMIN
21.5
25
27.0
kHz
tDT(MAX)
32
−
−
ms
1.18
0.770
0.590
−
1.25
0.833
0.640
−
1.40
0.900
0.690
−
Soft−Start Period
Flyback Overload Fault Timer
OTP Pull−Up Current Source
Autorecovery Timer
LIGHT/NO LOAD MANAGEMENT
Minimum Frequency Clamp
Dead−Time Added During Frequency
Foldback
VFB = 400 mV
Quiet−Skip Timer
Versions xxAxx
Versions xxBxx
Versions xxCxx
Versions xxDxx
tquiet
ms
Skip Threshold
VFB decreasing
Vskip
350
400
450
mV
Skip Hysteresis
VFB increasing
Vskip(HYS)
20
50
70
mV
2. NTC with R110 = 8.8 kW
www.onsemi.com
8
NCP1342
Table 5. ELECTRICAL CHARACTERISTICS: (VCC = 12 V, VHV = 120 V, VFault = open, VFB = 2.4 V, VCS = 0 V, VZCD = 0 V, VFMAX
= 0 V, CVCC = 100 nF , CDRV = 100 pF, for typical values TJ = 25°C, for min/max values, TJ is – 40°C to 125°C, unless otherwise noted)
Characteristics
Conditions
Symbol
Min
Typ
Max
340
300
250
200
−
400
350
300
250
−
460
400
350
300
−
780
−
800
−
820
−
730
−
750
−
770
−
0.85
−
1.00
−
1.05
−
Unit
MINIMUM PEAK CURRENT MODULATION (MPCM)
MPCM Current Shift
Versions xxxxA
Versions xxxxB
Versions xxxxC
Versions xxxxD
Versions xxxxE
VMPCM(delta)
MPCM Entry Threshold
Versions xxxxA, xxxxB, xxxxC, xxxxD
Versions xxxxE
VMPCM(entry)
MPCM Exit Threshold
Versions xxxxA, xxxxB, xxxxC, xxxxD
Versions xxxxE
VMPCM(exit)
MPCM Transition Timer
Versions xxxxA, xxxxB, xxxxC, xxxxD
Versions xxxxE
tMPCM
mV
mV
mV
ms
THERMAL PROTECTION
Thermal Shutdown
Temperature increasing
TSHDN
–
140
–
°C
Thermal Shutdown Hysteresis
Temperature decreasing
TSHDN(HYS)
–
40
–
°C
2. NTC with R110 = 8.8 kW
www.onsemi.com
9
NCP1342
INTRODUCTION
The NCP1342 implements a quasi−resonant flyback
converter utilizing current−mode architecture where the
switch−off event is dictated by the peak current. This IC is
an ideal candidate where low parts count and cost
effectiveness are the key parameters, particularly in ac−dc
adapters, open−frame power supplies, etc. The NCP1342
incorporates all the necessary components normally needed
in modern power supply designs, bringing several
enhancements such as non−dissipative overpower
protection (OPP), brownout protection, and frequency
reduction management for optimized efficiency over the
entire power range. Accounting for the needs of extremely
low standby power requirements, the controller features
minimized current consumption and includes an automatic
X2 capacitor discharge circuit that eliminates the need to
install power−consuming resistors across the X2 input
capacitors.
• High−Voltage Start−Up Circuit: Low standby power
consumption cannot be obtained with the classic
resistive start−up circuit. The NCP1342 incorporates a
high−voltage current source to provide the necessary
current during start−up and then turns off during normal
operation.
• Internal Brownout Protection: The ac input voltage is
sensed via the high−voltage pin. When this voltage is
too low, the NCP1342 stops switching. No restart
attempt is made until the ac input voltage is back within
its normal range.
• X2−Capacitor Discharge Circuitry: Per the
IEC60950 standard, the time constant of the X2 input
capacitors and their associated discharge resistors must
be less than 1 s in order to avoid electrical shock when
the user unplugs the power supply and inadvertently
touches the ac input cord terminals. By providing an
automatic means to discharge the X2 capacitors, the
NCP1342 eliminates the need to install X2 discharge
resistors, thus reducing power consumption.
• Quasi−Resonant, Current−Mode Operation:
Quasi−Resonant (QR) mode is a highly efficient mode
of operation where the MOSFET turn−on is
synchronized with the point where its drain−source
voltage is at the minimum (valley). A drawback of this
mode of operation is that the operating frequency is
inversely proportional to the system load. The
NCP1342 incorporates a valley lockout (VLO) and
frequency foldback technique to eliminate this
drawback, thus maximizing the efficiency over the
entire power range.
• Valley Lockout: In order to limit the maximum
frequency while remaining in QR mode, one would
traditionally use a frequency clamp. Unfortunately, this
can cause the controller to jump back and forth between
•
•
•
•
•
•
•
two different valleys, which is often undesirable. The
NCP1342 patented VLO circuitry solves this issue by
determining the operating valley based on the system
load, and locking out other valleys unless a significant
change in load occurs.
Frequency Foldback: As the load continues to
decrease, it becomes beneficial to reduce the switching
frequency. When the load is light enough, the NCP1342
enters frequency foldback mode. During this mode, the
minimum peak current is limited and dead−time is
added to the switching cycle, thus reducing the
frequency and switching operation to discontinuous
conduction mode (DCM). Dead−time continues to be
added until skip mode is reached, or the switching
frequency reaches its minimum level of 25 kHz.
Minimum Peak Current Modulation (MPCM): In
order to reduce the switching frequency even faster (for
high frequency designs), the NCP1342 uses MPCM to
increase the minimum peak current during frequency
foldback. It also reduces the minimum peak current
gradually as the load decreases to ensure optimum skip
mode entry.
Skip Mode: To further improve light or no−load power
consumption while avoiding audible noise, the
NCP1342 enters skip mode when the operating
frequency reaches its minimum value. To avoid
acoustic noise, the circuit prevents the switching
frequency from decaying below 25 kHz. This allows
regulation via bursts of pulses at 25 kHz or greater
instead of operating in the audible range.
Quiet−Skip: To further reduce acoustic noise, the
NCP1342 incorporates a novel circuit to prevent the
skip mode burst period from entering the audible range
as well.
Internal OPP: In order to limit power delivery at high
line, a scaled version of the negative voltage present on
the auxiliary winding during the on−time is routed to
the ZCD/OPP pin. This provides the designer with a
simple and non−dissipative means to reduce the
maximum power capability as the bulk voltage
increases.
Frequency Jittering: In order to reduce the EMI
signature, a low frequency triangular voltage waveform
is added to the input of the PWM comparator. This
helps by spreading out the energy peaks during noise
analysis.
Internal Soft−Start: The NCP1342 includes a 4 ms
soft−start to prevent the main power switch from being
overly stressed during start−up. Soft−start is activated
each time a new startup sequence occurs or during
auto−recovery mode.
www.onsemi.com
10
NCP1342
• Dedicated Fault Input: The NCP1342 includes a
•
•
is available disabled or fixed at 110 kHz. In the 9−pin
versions, the clamp can be adjusted via an external
resistor from the FMAX Pin to ground. It can also be
disabled by pulling the FMAX pin above 4 V.
dedicated fault input. It can be used to sense an
overvoltage condition and latch off the controller by
pulling the pin above the overvoltage protection (OVP)
threshold. The controller is also disabled if the Fault pin
is pulled below the overtemperature protection (OTP)
threshold. The OTP threshold is configured for use with
a NTC thermistor.
Overload/Short−Circuit Protection: The NCP1342
implements overload protection by limiting the
maximum time duration for operation during overload
conditions. The overload timer operates whenever the
maximum peak current is reached. In addition to this,
special circuitry is included to prevent operation in
CCM during extreme overloads, such as an output
short−circuit.
Maximum Frequency Clamp: The NCP1342 includes
a maximum frequency clamp. In all versions, the clamp
AC
CON
HIGH VOLTAGE START−UP
The NCP1342 contains a multi−functional high voltage
(HV) pin. While the primary purpose of this pin is to reduce
standby power while maintaining a fast start−up time, it also
incorporates brownout detection and line removal detection.
The HV pin must be connected directly to the ac line in
order for the X2 discharge circuit to function correctly. Line
and neutral should be diode “ORed” before connecting to the
HV pin as shown in Figure 4. The diodes prevent the pin
voltage from going below ground. A resistor in series with
the pin should be used to protect the pin during EMC or surge
testing. A low value resistor should be used (<5 kW) to
reduce the voltage offset during start−up.
EMI
HV
Controller
Figure 4. High−Voltage Input Connection
Start−up and VCC Management
During start−up, the current source turns on and charges
the VCC capacitor with Istart2 (typically 6 mA). When Vcc
reaches VCC(on) (typically 16.0 V), the current source turns
off. If the input voltage is not high enough to ensure a proper
start−up (i.e. VHV has not reached VBO(start)), the controller
will not start. VCC then begins to fall because the controller
bias current is at ICC2 (typically 1 mA) and the auxiliary
supply voltage is not present. When VCC falls to VCC(off)
(typically 10.5 V), the current source turns back on and
charges VCC. This cycle repeats indefinitely until VHV
reaches VBO(start). Once this occurs, the current source
immediately turns on and charges VCC to VCC(on), at which
point the controller starts (see Figure 6).
When VCC is brought below VCC(inhibit), the start−up
current is reduced to Istart1 (typically 0.5 mA). This limits
power dissipation on the device in the event that the VCC pin
is shorted to ground. Once VCC rises back above VCC(inhibit),
the start−up current returns to Istart2.
Once VCC reaches VCC(on), the controller is enabled and
the controller bias current increases to ICC3 (typically
2.0 mA). However, the total bias current is greater than this
due to the gate charge of the external switching MOSFET.
The increase in ICC due to the MOSFET is calculated using
Equation 1.
DI CC + f sw @ Q G @ 10 −3
(eq. 1)
where DICC is the increase in milliamps, fsw is the switching
frequency in kilohertz and QG is the gate charge of the
external MOSFET in nanocoulombs.
CVCC must be sized such that a VCC voltage greater than
VCC(off) is maintained while the auxiliary supply voltage
increases during start−up. If CVCC is too small, VCC will fall
below VCC(off) and the controller will turn off before the
auxiliary winding supplies the IC. The total ICC current after
the controller is enabled (ICC3 plus DICC) must be
considered to correctly size CVCC.
www.onsemi.com
11
NCP1342
Figure 5. Start−up Circuitry Block Diagram
VHV
VBO(start)
VHV(MIN)
VCC
VCC(on)
VCC(off)
Start−up
Current = Istart2
Start−up
Current = Istart1
VCC(inhibit )
DRV
Figure 6. Start−up Timing
www.onsemi.com
12
tdelay (start )
NCP1342
DRIVER
The peak current level is clamped during the soft−start
phase. The setpoint is actually limited by a clamp level
ramping from 0 to 0.8 V within 4 ms.
In addition to the PWM comparator, a dedicated
comparator monitors the current sense voltage, and if it
reaches the maximum value, VILIM (typically 800 mV), the
gate driver is turned off and the overload timer is enabled.
This occurs even if the limit imposed by the feedback
voltage is higher than VILIM1. Due to the parasitic
capacitances of the MOSFET, a large voltage spike often
appears on the CS Pin at turn−on. To prevent this spike from
falsely triggering the current sense circuit, the current sense
signal is blanked for a short period of time, tLEB1 (typically
275 ns), by a leading edge blanking (LEB) circuit. Figure 7
shows the schematic of the current sense circuit.
The peak current is also limitied to a minimum level,
VCS(MIN) (0.2 V, typically). This results in higher efficiency
at light loads by increasing the minimum energy delivered
per switching cycle, while reducing the overall number of
switching cycles during light load.
The NCP1342 maximum supply voltage, VCC(MAX), is
28 V. Typical high−voltage MOSFETs have a maximum
gate voltage rating of 20 V. The DRV pin incorporates an
active voltage clamp to limit the gate voltage on the external
MOSFETs. The DRV voltage clamp, VDRV(high) is typically
12 V with a maximum limit of 14 V.
REGULATION CONTROL
Peak Current Control
The NCP1342 is a peak current−mode controller, thus the
FB voltage sets the peak current flowing in the transformer
and the MOSFET. This is achieved by sensing the MOSFET
current across a resistor and applying the resulting voltage
ramp to the non−inverting input of the PWM comparator
through the CS pin. The current limit threshold is set by
applying the FB voltage divided by KFB (typically 4) to the
inverting input of the PWM comparator. When the current
sense voltage ramp exceeds this threshold, the output driver
is turned off, however, the peak current is affected by several
functions (see Figure 7):
ROPP
ZCD/OPP
OPP
V FB(open)
Minimum Peak
Current
+
*
R FB
FB
V ILIM1
DRV Off
V CS(MIN)
K FB
*
+
Soft−Start
Ramp
PWM
*
+
OCP
*
+
CS
t LEB1
R sense
Overload Timer
AOCP
t LEB2
+
*
V ILIM2
Figure 7. Current Sense Logic
www.onsemi.com
13
Abnormal OCP Counter
NCP1342
Zero Current Detection
As shown by Figure 13, a valley is detected once the ZCD
pin voltage falls below the demagnetization threshold,
VZCD(trig), typically 55 mV. The controller will either switch
once the valley is detected or increment the valley counter,
depending on the FB voltage.
The NCP1342 is a quasi−resonant (QR) flyback
controller. While the power switch turn−off is determined by
the peak current set by the feedback loop, the switch turn−on
is determined by the transformer demagnetization. The
demagnetization is detected by monitoring the transformer
auxiliary winding voltage.
Turning on the power switch once the transformer is
demagnetized has the benefit of reduced switching losses.
Once the transformer is demagnetized, the drain voltage
starts ringing at a frequency determined by the transformer
magnetizing inductance and the drain lump capacitance,
eventually settling at the input voltage. A QR flyback
controller takes advantage of the drain voltage ringing and
turns on the power switch at the drain voltage minimum or
“valley” to reduce switching losses and electromagnetic
interference (EMI).
Overpower Protection
The average bulk capacitor voltage of the QR flyback
varies with the RMS line voltage. Thus, the maximum
power capability at high line can be much higher than
desired. An integrated overpower protection (OPP) circuit
provides a relatively constant output power limit across the
input voltage on the bulk capacitor, Vbulk. Since it is a
high−voltage rail, directly measuring Vbulk will contribute
losses in the sensing network that will greatly impact the
standby power consumption. The NCP1342 OPP circuit
achieves this without the need for a high−voltage sensing
network, and is essentially lossless.
V FB(open)
R FB
PWM
K FB
t LEB1
OCP
DRV Off
VOPP
V ILIM1
Figure 8. OPP Circuit Schematic
www.onsemi.com
14
FB
CS
ZCD/OPP
VAUX (V)
NCP1342
⎛N
− ⎢ AUX . VBULK
⎝ NP
⎛
⎢
⎝
Figure 9. Auxiliary Winding Voltage
The ratio between RZCD and ROPPL is given by
Equation 5. It is obtained by combining Equations 3 and 4.
Since the auxiliary winding voltage during the power
switch on time is a reflection of the input voltage scaled by
the primary to auxiliary winding turns ratio, NP:AUX (see
Figure 9), OPP is achieved by scaling down reflected
voltage during the on−time and applying it to the ZCD pin
as a negative voltage, VOPP. The voltage is scaled down by
a resistor divider comprised of ROPPU and ROPPL. The
maximum internal current setpoint (VCS(OPP)) is simply the
sum of VOPP and the peak current sense threshold, VILIM1.
Figure 8 shows the schematic for the OPP circuit.
The adjusted peak current limit is calculated using
Equation 2. For example, a VOPP of −150 mV results in a
peak current limit of 650 mV in NCP1342.
V CS(OPP) + V OPP ) V ILIM1
V
R ZCD
* V F * V ZCD
+ AUX
R OPPL
V ZCD
A design example is shown below:
System Parameters:
V AUX + 18 V
V F + 0.6 V
N P:AUX + 0.18
The ratio between RZCD and ROPPL is calculated using
Equation 5 for a minimum VZCD of 8 V.
R ZCD
18 V * 0.6 V * 8 V
+
+ 1.2 kW
R OPPL
8V
(eq. 2)
To ensure optimal zero−crossing detection, a diode is
needed to bypass ROPPU during the off−time. Equation 3 is
used to calculate ROPPU and ROPPL.
N
R ZCD ) R OPPU
@ V bulk * V OPP
+ * P:AUX
R OPPL
V OPP
RZCD is arbitrarily set to 1 kW. ROPPL is also set to 1 kW
because the ratio between the resistors is close to 1.
The NCP1342 maximum overpower compensation or
peak current setpoint reduction is 31.25% for a VOPP of
−250 mV. We will use this value for the following example:
Substituting values in Equation 3 and solving for ROPPU
we obtain:
(eq. 3)
ROPPU is selected once a value is chosen for ROPPL.
ROPPL is selected large enough such that enough voltage is
available for the zero−crossing detection during the
off−time. It is recommended to have at least 8 V applied on
the ZCD pin for good detection. The maximum voltage is
internally clamped to VCC. The off−time voltage on the ZCD
Pin is given by Equation 4.
V ZCD +
R OPPL
@ ǒV AUX * V FǓ
R ZCD ) R OPPL
(eq. 5)
R ZCD ) R OPPU
0.18 @ 370 V * (−0.25 V)
+
+ 271
R OPPL
−0.25 V
R OPPU + 271 @ R OPPL * R ZCD
R OPPU + 271 @ 1 kW * 1 kW + 270 kW
(eq. 4)
For optimum performance over temperature, it is
recommended to keep ROPPL below 3 kW.
Where VAUX is the voltage across the auxiliary winding
and VF is the DOPP forward voltage drop.
www.onsemi.com
15
NCP1342
Soft−Start
in CCM for several cycles until the voltage on the ZCD pin
is high enough to prevent the timer from running. Therefore,
a longer timeout period, ttout1 (typically 100 ms), is used
during soft−start to prevent CCM operation.
Soft−start is achieved by ramping up an internal reference,
VSSTART, and comparing it to the current sense signal.
VSSTART ramps up from 0 V once the controller initially
powers up. The peak current setpoint is then limited by the
VSSTART ramp resulting in a gradual increase of the switch
current during start−up. The soft−start duration, tSSTART, is
typically 4 ms.
During startup, demagnetization phases are long and
difficult to detect since the auxiliary winding voltage is very
small. In this condition, the 6 ms steady−state timeout is
generally shorter than the inductor demagnetization period.
If it is used to restart a switching cycle, it can cause operation
Frequency Jittering
In order to help meet stringent EMI requirements, the
NCP1342 features frequency jittering to average the energy
peaks over the EMI frequency range. As shown in Figure 10,
the function consists of summing a triangular wave of
amplitude Vjitter and frequency fjitter with the CS signal
immediately before the PWM comparator. This current acts
to modulate the on−time and hence the operation frequency.
VDD
RFB
FB
KFB
Vjitter
CS
LEB
VOPP
DRV Off
VILIM1
VCS(MIN)
Figure 10. Jitter Implementation
1000
Since the jittering function modulates the peak current
level, the FB signal will attempt to compensate for this effect
in order to limit the output voltage ripple. Therefore, the
bandwidth of the feedback loop must be well below the jitter
frequency, or the jitter function will be filtered by the loop.
Due to the minimum peak current, the effect of the
jittering circuit will not be seen during frequency foldback
mode.
900
FSW(MAX) (kHz)
800
Maximum Frequency Clamp
F SW(MAX) +
R FMAX * 10 mA
600
500
400
300
200
All 9−pin versions of the NCP1342 include an adjustable
maximum frequency clamp via an external resistor from the
FMAX Pin to ground. It can also be disabled by pulling the
FMAX pin above 4 V. The maximum frequency can be
programmed using Equation 6, and is shown in Figure 11.
261 kHz * 1 V
700
100
0
0
50
100
150 200
250
RFMAX (kW)
300 350 250
Figure 11. FSW(MAX) vs. RFMAX
(eq. 6)
www.onsemi.com
16
NCP1342
LIGHT LOAD MANAGEMENT
a valley is selected, the controller stays locked in this valley
until the output power changes significantly. This technique
extends the QR mode operation over a wider output power
range while maintaining good efficiency and limiting the
maximum operating frequency.
The operating valley (1st, 2nd, 3rd, 4th, 5th or 6th) is
determined by the FB voltage. An internal counter
increments each time a valley is detected by the ZCD/OPP
Pin. Figure 12 shows a typical frequency characteristic
obtainable at low line in a 65 W application.
Valley Lockout Operation
The operating frequency of a traditional QR flyback
controller is inversely proportional to the system load. In
other words, a load reduction increases the operating
frequency. A maximum frequency clamp can be useful to
limit the operating frequency range. However, when used by
itself, such an approach often causes instabilities since when
this clamp is active, the controller tends to jump (or hesitate)
between two valleys, thus generating audible noise.
Instead, the NCP1342 also incorporates a patented valley
lockout (VLO) circuitry to eliminate valley jumping. Once
1x10
Fsw (Hz)
8x10
6x10
6th 5th 4th
5
2x10
2nd
1st
VCO
4 mode
4
6th
4x10
3rd
5th
4th
3rd
2nd
1st
4
4
0
VCO
mode
0
20
40
60
Pout (W)
Figure 12. Valley Lockout Frequency vs. Output Power
peak current to deliver the necessary output power. Each
valley selection comparator features a 600 mV hysteresis
that helps stabilize operation despite the FB voltage swing
produced by the regulation loop.
When an “n” valley is asserted by the valley selection
circuitry, the controller is locked in this valley until the FB
voltage decreases to the lower threshold (“n+1” valley
activates) or increases to the “n valley threshold” + 600 mV
(“n−1” valley activates). The regulation loop adjusts the
Table 6. VALLEY FB THRESHOLDS (typical values)
FB Falling
1st to 2nd valley
FB Rising
1.400 V
2nd to 1st valley
2.000 V
1.200 V
3rd
valley
1.100 V
4th
4th to 5th valley
1.000 V
0.900 V
6th
1.500 V
2nd
3rd
5th
to
3rd
to
4th
to
6th
valley
valley
Valley Timeout
to
2nd
valley
1.800 V
to
3rd
valley
1.700 V
5th to 4th valley
1.600 V
to
5th
valley
signal acts as a substitute for the ZCD signal to the valley
counter. Figure 13 shows the valley timeout circuit
schematic. The steady state timeout period, ttout2, is set at 6
ms (typical) to limit the frequency step.
During startup, the voltage offset added by the OPP diode,
DOPP, prevents the ZCD Comparator from accurately
detecting the valleys. In this condition, the steady state
In case of extremely damped oscillations, the ZCD
comparator may not be able to detect the valleys. In this
condition, drive pulses will stop while the controller waits
for the next valley or ZCD event. The NCP1342 ensures
continued operation by incorporating a maximum timeout
period after the last demagnetization detection. The timeout
www.onsemi.com
17
NCP1342
the FB voltage sets VLO mode to turn on at the fifth valley,
and the ZCD ringing is damped such that the ZCD circuit is
only able to detect:
• Valleys 1 to 4: the circuit generates a DRV pulse 6 ms
(steady−state timeout delay) after the 4th valley
detection.
• Valleys 1 to 3: the timeout delay must run twice, and
the circuit generates a DRV pulse 12 ms after the 3rd
valley detection.
timeout period will be shorter than the inductor
demagnetization period causing CCM operation. CCM
operation lasts for a few cycles until the voltage on the ZCD
pin is high enough to detect the valleys. A longer timeout
period, ttout1, (typically 100 ms) is set during soft−start to
limit CCM operation.
In VLO operation, the number of timeout periods are
counted instead of valleys when the drain−source voltage
oscillations are too damped to be detected. For example, if
Figure 13. Valley Timeout Circuitry
Frequency Foldback with Minimum Peak Current
Modulation (MPCM)
minimum frequency clamp prevents the switching
frequency from dropping below 25 kHz to eliminate the risk
of audible noise. Note that the dead−time is not added (it is
blanked) until MPCM is engaged to ensure valley switching
prior to entering MPCM mode.
In addition to dead−time, the peak current setpoint is
linearly reduced as VFB falls down to 0.4 V. This ensures that
the peak current is not too high during the lightest loads, and
has the effect of reducing the skip entry power level.
Figure 14 shows the MPCM with respect to the feedback
voltage, while Figure 15 shows the VLO to FF operation.
To reduce the output power hysteresis between entering
and exiting MPCM, the exit threshold (VMPCM(exit)) is set
slightly below the entry threshold (750 mV typical). A 1 ms
timer, tMPCM, is engaged every time MPCM is entered or
exited to prevent oscillations during the operating point
transition. If at any time FB falls to skip mode, or rises to 5th
valley, MPCM will be immediately exited regardless of
tMPCM.
As the output load decreases (FB voltage decreases), the
valleys are incremented from 1 to 6. When the sixth valley
is reached and the FB voltage further decreases to
VMPCM(entry) (800 mV typical), the controller enters MPCM
and begins frequency foldback (FF). At this point, the
minimum peak current is increased by VMPCM(delta)
(400 mV typical). The increase in peak current serves to
force the switching frequency to a much lower value, thus
improving the efficiency at light loads. During this mode,
the controller regulates the power delivery by modulating
the switching frequency.
Once in frequency foldback mode, the controller reduces
the switching frequency by adding dead−time after the 6th
valley is detected. This dead−time increases as the FB
voltage decreases.
The dead−time circuit is designed to add 0 ms dead−time
when VFB = 0.4 V and linearly increases the total dead−time
to tDT(MAX) (36 ms typical) as VFB falls down to 0.4 V. The
www.onsemi.com
18
NCP1342
Minimum Peak Current
VCS(MIN) + VMPCM(delta)
VMPCM(delta)
VCS(MIN)
VFB
VMPCM(entry)
Vskip
Figure 14. Minimum Peak Current Modulation
Operating Mode
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
ÌÌÌÌÌ
V
decreases
FB
FF
V FB increases
Valley 6
Valley 5
Valley 4
Fault !
Valley 3
Valley 2
Valley 1
0.8
0.9
1.0
1.1
1.2
1.4
1.5
1.6
1.7
1.8
Figure 15. Valley Lockout Thresholds
www.onsemi.com
19
2.0
3.2
V
(V)
FB
NCP1342
Minimum Frequency Clamp and Skip Mode
as the current drive pulses ends – it does not stop
immediately.
Once switching stops, FB will rise. As soon as FB crosses
the skip−exit threshold, drive pulses will resume, but the
controller remains in burst mode. At this point, a 1.25 ms
timer, tquiet, is started together with a count−to−3 counter.
The next time the FB voltage drops below the skip−in
threshold, drive pulses stop at the end of the current pulse as
long as 3 drive pulses have been counted (if not, they do not
stop until the end of the 3rd pulse). They are not allowed to
start again until the timer expires, even if the skip−exit
threshold is reached first. It is important to note that the
timer will not force the next cycle to begin – i.e. if the natural
skip frequency is such that skip−exit is reached after the
timer expires, the drive pulses will wait for the skip−exit
threshold.
This means that during no−load, there will be a minimum
of 3 drive pulses, and the burst−cycle period will likely be
much longer than 1.25 ms. This operation helps to improve
efficiency at no−load conditions.
In order to exit burst mode, the FB voltage must rise higher
than 1 V. If this occurs before tquiet expires, the drive pulses
will resume immediately – i.e. the controller won’t wait for
the timer to expire. Figure 16 provides an example of how
Quiet−Skip works.
As mentioned previously, the circuit prevents the
switching frequency from dropping below fMIN (25 kHz
typical). When the switching cycle would be longer than
40 ms, the circuit forces a new switching cycle. However, the
fMIN clamp cannot generate a DRV pulse until the
demagnetization is completed. In other words, it will not
cause operation in CCM.
Since the NCP1342 forces a minimum peak current and a
minimum frequency, the power delivery cannot be
continuously controlled down to zero. Instead, the circuit
starts skipping pulses when the FB voltage drops below the
skip level, Vskip, and recovers operation when VFB exceeds
Vskip + Vskip(HYS). This skip−mode method provides an
efficient method of control during light loads.
Quiet−Skip
To further avoid acoustic noise, the circuit prevents the
burst frequency during skip mode from entering the audible
range by limiting it to a maximum of 800 Hz. This is
achieved via a timer (tquiet) that is activated during
Quiet−Skip. The start of the next burst cycle is prevented
until this timer has expired.
As the output power decreases, the switching frequency
decreases. Once it hits 25 kHz, the skip−in threshold is
reached and burst mode is entered − switching stops as soon
www.onsemi.com
20
NCP1342
MAX
Load
Fsw >= 25 kHz
DRV
1.25 ms
Fsw >= 25 kHz
1.25 ms
Fsw >= 25 kHz
1.25 ms
Fsw >= 25 kHz
1.25 ms
Fsw >= 25 kHz
DRV
FB
DRV
FB
DRV
FB
DRV
FB
>1.25 ms
Fsw >= 25 kHz
DRV
MIN
Load
FB
Figure 16. Quiet−Skip Timing Diagram
www.onsemi.com
21
NCP1342
FAULT MANAGEMENT
external latch input. When the NCP1342 detects a latching
fault, the driver is immediately disabled. The operation
during a latching fault is identical to that of a non−latching
fault except the controller will not attempt to restart at the
next VCC(on), even if the fault is removed. In order to clear
the latch and resume normal operation, VCC must first be
allowed to drop below VCC(reset) or a line removal event
must be detected. This operation is shown in Figure 17.
The NCP1342 contains three separate fault modes.
Depending on the type of fault, the device will either latch
off, restart when the fault is removed, or resume operation
after the auto−recovery timer expires.
Latching Faults
Some faults will cause the NCP1342 to latch off. These
include the abnormal OCP (AOCP), VCC OVP, and the
Fault
Fault
Applied
Fault
Removed
time
V CC
V CC (on)
V CC (off)
time
FDRV
time
I HV
Istart 2
I start (off)
time
Figure 17. Operation During Latching Fault
www.onsemi.com
22
NCP1342
Non−Latching Faults
re−enabled when VCC reaches VCC(on) according to the
initial power−on sequence, provided VHV is above
VBO(start). This operation is shown in Figure 18. When VHV
is reaches VBO(start), VCC immediately charges to VCC(on).
If VCC is already above VCC(on) when the fault is removed,
the controller will start immediately as long as VHV is above
VBO(start).
When the NCP1342 detects a non−latching fault
(brownout or thermal shutdown), the drivers are disabled,
and VCC falls towards VCC(off) due to the IC internal current
consumption. Once VCC reaches VCC(off), the HV current
source turns on and CVCC begins to charge towards VCC(on).
When VCC, reaches VCC(on), the cycle repeats until the fault
is removed. Once the fault is removed, the NCP1342 is
Fault
Fault
Applied
Fault
Removed
Waits for next
V CC(on) before
starting
VCC
time
V CC (on )
V CC (off )
time
FDRV
time
IHV
Istart 2
Istart (off)
time
Figure 18. Operation During Non−Latching Fault
www.onsemi.com
23
NCP1342
Auto−recovery Timer Faults
running, the HV current source turns on and off to maintain
Vcc between Vcc(off) and Vcc(on). Once the auto−recovery
timer expires, the controller will attempt to start normally at
the next VCC(on) provided VHV is above VBO(start). This
operation is shown in Figure 19.
Some faults faults cause the NCP1342 auto−recovery
timer to run. If an auto−recovery fault is detected, the gate
drive is disabled and the auto−recovery timer, tautorec
(typically 1.2 s), starts. While the auto−recovery timer is
Fault
Applied
Fault
Removed
Fault
time
VCC
VCC(on)
VCC(off)
Restarts
At VCC(on)
(new burst
cycle if Fault
still present)
DRV
time
Controller
stops
time
Autorecovery
Timer
1.2 s
trestart
Figure 19. Operation During Auto−Recovery Fault
www.onsemi.com
24
time
NCP1342
PROTECTION FEATURES
Brownout Protection
Figure 20 shows the brownout detector waveforms during
a brownout.
When a brownout is detected, the controller stops
switching and enters non−latching fault mode (see
Figure 18). The HV current source alternatively turns on and
off to maintain VCC between VCC(on) and VCC(off) until the
input voltage is back above VBO(start).
A timer is enabled once VHV drops below its disable
threshold, VBO(stop) (typically 99 V). The controller is
disabled if VHV doesn’t exceed VBO(stop) before the
brownout timer, tBO (typically 54 ms), expires. The timer is
set long enough to ignore a two cycle dropout. The timer
starts counting once VHV drops below VBO(stop).
V HV
V BO (start )
V BO (stop )
time
Brownout
Timer
Brownout
detected
Starts
Charging
Immediately
V CC
V CC (on)
Fault
Cleared
Restarts at
next V CC(on)
time
V CC (off )
tdelay (start )
time
DRV
Figure 20. Operation During Brownout
Line Removal Detection and X2 Capacitor Discharge
time
discharge circuitry. A novel approach is used to reconfigure
the high voltage startup circuit to discharge the input filter
capacitors upon removal of the ac line voltage. The line
removal detection circuitry is always active to ensure safety
compliance.
The line removal is detected by digitally sampling the
voltage present at the HV pin, and monitoring the slope.
A timer, tline(removal) (typically 100 ms), is used to detect
when the slope of the input signal is negative or below the
resolution level. The timer is reset any time a positive slope
Safety agency standards require the input filter capacitors
to be discharged once the ac line voltage is removed. A
resistor network is the most common method to meet this
requirement. Unfortunately, the resistor network consumes
power across all operating modes and it is a major
contributor of input power losses during light−load and
no−load conditions.
The NCP1342 eliminates the need for external discharge
resistors by integrating active input filter capacitor
www.onsemi.com
25
NCP1342
is detected. Once the timer expires, a line removal condition
is acknowledged initiating an X2 capacitor discharge cycle,
and the controller is disabled.
If VCC is above VCC(on), it is first discharged to VCC(on).
A second timer, tline(discharge) (typically 32 ms), is used for
the time limiting of the discharge phase to protect the device
against overheating. Once the discharge phase is complete,
tline(discharge) is reused while the device checks to see if the
line voltage is reapplied. During the discharge phase, if VCC
drops to VCC(on), it is quickly recharged to VCC(X2_reg). The
discharging process is cyclic and continues until the ac line
is detected again or the voltage across the X2 capacitor is
lower than VHV(discharge) (30 V maximum). This feature
allows the device to discharge large X2 capacitors in the
input line filter to a safe level.
It is important to note that the HV pin cannot be
connected to any dc voltage due to this feature, i.e.
directly to the bulk capacitor.
X2 Capacitor
Discharge
VHV
VBO(start )
VBO(stop)
X2 Capacitor
Discharge
AC Line Unplug
VHV(discharge )
time
AC
Timer
Starts
Timer
tline(removal )
AC
Timer
Restarts
AC
Timer
Expires
No AC Detection
tline(discharge /detect )
tline(removal )
DRV
tline(discharge )
tline(detect )
X2 Discharge
X2 Discharge
Current
Device is stopped
Istart 2
ICC
ICC(discharge )
0
ICC3
Istart 2
VCC
VCC(X2_reg)
VCC(on)
Figure 21. Line Removal Timing
www.onsemi.com
26
tline(discharge )
X2 Discharge
time
NCP1342
X2 Capacitor
Discharge
VHV
VBO(start )
VBO(stop )
AC Line Unplug
VHV(discharge )
AC
Timer
Starts
Timer
tline (removal )
AC
Timer
Expires
AC
Timer
Restarts
time
AC Detected
tline(discharge /detect )
time
X2 Discharge
Device is stopped
X2 Discharge
Current
time
tline (discharge )
tline (removal )
DRV
tdelay (start )
Istart 2
time
ICC
ICC(discharge )
0
ICC3
Istart 2
time
VCC
VCC(X2_reg)
VCC(on)
Figure 22. Line Removal Timing with AC Reapplied
the lower fault threshold, VFault(OTP_in) (typically 0.4 V).
The lower threshold is normally used for detecting an
overtemperature fault. The controller operates normally
while the Fault pin voltage is maintained within the upper
and lower fault thresholds. Figure 23 shows the architecture
of the Fault input.
The Fault input signal is filtered to prevent noise from
triggering the fault detectors. Upper and lower fault detector
blanking delays, tdelay(OVP) and tdelay(OTP),are both
typically 30 ms. A fault is detected if the fault condition is
asserted for a period longer than the blanking delay.
An over temperature protection block monitors the
junction temperature during the discharge process to avoid
thermal runaway, in particular during open/short pins safety
tests. Please note that the X2 discharge capability is also
active at all times, including off−mode and before the
controller actually starts to pulse (e.g. if the user unplugs the
converter during the start−up sequence).
Dedicated Fault Input
The NCP1342 includes a dedicated fault input accessible
via the Fault pin (8−pin and 9−pin versions only). The
controller can be latched by pulling up the pin above the
upper fault threshold, VFault(OVP) (typically 3.0 V). The
controller is disabled if the Fault pin voltage is pulled below
www.onsemi.com
27
NCP1342
OVP
voltage drop across the thermistor. The resistance of the
NTC thermistor decreases at higher temperatures resulting
in a lower voltage across the thermistor. The controller
detects a fault once the thermistor voltage drops below
VFault(OTP_in).
The controller bias current is reduced during power up by
disabling most of the circuit blocks including IFault(OTP).
This current source is enabled once VCC reaches VCC(on). A
filter capacitor is typically connected between the Fault and
GND pins. This will result in a delay before VFault reaches
its steady state value once IFault(OTP) is enabled. Therefore,
the lower fault comparator (i.e. overtemperature detection)
is ignored during soft−start.
Version A latches off the controller after an
overtemperature fault is detected according to Figure 17. In
Version B, the controller is re−enabled once the fault is
removed such that VFault increases above VFault(OTP_out),
the auto−recovery timer expires, and VCC reaches VCC(on)
as shown in Figure 19.
An active clamp prevents the Fault pin voltage from
reaching the upper latch threshold if the pin is open. To reach
the upper threshold, the external pull−up current has to be
higher than the pull−down capability of the clamp (set by
RFault(clamp) at VFault(clamp)), i.e., approximately 1 mA.
The upper fault threshold is intended to be used for an
overvoltage fault using a zener diode and a resistor in series
from the auxiliary winding voltage. The controller is latched
once VFault exceeds VFault(OVP).
Once the controller is latched, it follows the behavior of
a latching fault according to Figure 17 and is only reset if
VCC is reduced to VCC(reset), or X2 discharge is activated. In
the typical application these conditions occur only if the ac
voltage is removed from the system.
OTP
The lower fault threshold is intended to be used to detect
an overtemperature fault using an NTC thermistor. A pull up
current source, IFault(OTP) (typically 45.0 mA), generates a
Figure 23. Fault Pin Internal Schematic
www.onsemi.com
28
NCP1342
• The controller latches off (version A) or
• Enters a safe, low duty−ratio auto−recovery mode
Overload Protection
The overload timer integrates the duration of the overload
fault. That is, the timer count increases while the fault is
present and reduces its count once it is removed. The
overload timer duration, tOVLD, is typically 160 ms. When
the overload timer expires, the controller detects an overload
condition does one of the following:
(version B).
Figure 24 shows the overload circuit schematic, while
Figure 25 and Figure 26 show operating waveforms for
latched and auto−recovery overload conditions.
V FB(open)
R FB
PWM
t OVLD
OCP + OPP
Count Down
KFB
FB
t LEB1
CS
VOPP
Count Up
V ILIM1
DRV Off
AOCP
Abnormal OCP
t LEB2
Count 4
V ILIM2
Figure 24. Overload Circuitry
www.onsemi.com
29
ZCD/OPP
NCP1342
Fault
Latch
Event
Latch
time
V CC
V CC(on)
V CC(off)
time
DRV
time
I HV
Istart2
IHV(off)
time
Figure 25. Latched Overload Operation
www.onsemi.com
30
NCP1342
Output Load
Fault
disappears
Overcurrent
applied
Max Load
time
Fault Flag
Fault
timer
starts
time
VCC
VCC(on)
VCC(off)
Restarts
At VCC(on)
(new burst
cycle if Fault
still present)
DRV
time
Controller
stops
time
Fault timer
160 ms
tOVLD
trestart
Figure 26. Auto−Recovery Overload Operation
www.onsemi.com
31
time
tdelay(start)
NCP1342
Abnormal Overcurrent Protection (AOCP)
core. Due to the valley timeout feature of the controller, the
flux level will quickly walk up until the core saturates. This
can cause excessive stress on the primary MOSFET and
secondary diode. This is not a problem for the NCP1342,
however, because the valley timeout timer is disabled while
the ZCD Pin voltage is above the arming threshold. Since the
leakage energy is high enough to arm the ZCD trigger, the
timeout timer is disabled and the next drive pulse is delayed
until demagnetization occurs.
Under some severe fault conditions, like a winding
short−circuit, the switch current can increase very rapidly
during the on−time. The current sense signal significantly
exceeds VILIM1, but because the current sense signal is
blanked by the LEB circuit during the switch turn−on, the
power switch current can become huge and cause severe
system damage.
The NCP1342 protects against this fault by adding an
additional comparator for Abnormal Overcurrent Fault
detection. The current sense signal is blanked with a shorter
LEB duration, tLEB2, typically 125 ns, before applying it to
the Abnormal Overcurrent Fault Comparator. The voltage
threshold of the comparator, VILIM2, typically 1.2 V, is set
50% higher than VILIM1, to avoid interference with normal
operation. Four consecutive Abnormal Overcurrent faults
cause the controller to enter latch mode. The count to 4
provides noise immunity during surge testing. The counter
is reset each time a DRV pulse occurs without activating the
Fault Overcurrent Comparator.
VCC Overvoltage Protection
An additional comparator on the VCC pin monitors the
VCC voltage. If VCC exceeds VCC(OVP), the gate drive is
disabled and the NCP1342 follows the operation of a
latching fault (see Figure 17).
Thermal Shutdown
An internal thermal shutdown circuit monitors the
junction temperature of the controller. The controller is
disabled if the junction temperature exceeds the thermal
shutdown threshold, TSHDN (typically 140°C). When a
thermal shutdown fault is detected, the controller enters a
non−latching fault mode as depicted in Figure 18. The
controller restarts at the next VCC(on) once the junction
temperature drops below below TSHDN by the thermal
shutdown hysteresis, TSHDN(HYS), typically 40°C.
The thermal shutdown is also cleared if VCC drops below
VCC(reset), or a line removal fault is detected. A new power
up sequence commences at the next VCC(on) once all the
faults are removed.
Current Sense Pin Failure Protection
A 1 mA (typically) pull−up current source, ICS, pulls up the
CS pin to disable the controller if the pin is left open.
Additionally, the maximum on−time, ton(MAX) (32 ms
typically), prevents the MOSFET from staying on
permanently if the CS Pin is shorted to GND.
Output Short Circuit Protection
During an output short−circuit, there is not enough
voltage across the secondary winding to demagnetize the
www.onsemi.com
32
NCP1342
TYPICAL CHARACTERISTICS
17.14
9
17.12
8.99
17.1
8.98
VCC(off) (V)
VCC(on) (V)
17.08
17.06
17.04
17.02
17
8.97
8.96
8.95
16.98
8.94
16.96
16.94
−40
−20
0
20
40
60
80
100
120
8.93
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 27. VCC(on) vs. Temperature
Figure 28. VCC(off) vs. Temperature
0.6
120
5
4.5
0.5
4
3.5
Istart2 (mA)
Istart1 (mA)
0.4
0.3
0.2
3
2.5
2
1.5
1
0.1
0.5
0
−40
−20
0
20
40
60
80
100
0
−40
120
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 29. Istart1 vs. Temperature
Figure 30. Istart2 vs. Temperature
7
120
9
8
6
7
IHV(off2) (mA)
IHV(off1) (mA)
5
4
3
2
6
5
4
3
2
1
0
−40
1
−20
0
20
40
60
80
100
120
0
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 31. IHV(off1) vs. Temperature
Figure 32. IHV(off2) vs. Temperature
www.onsemi.com
33
120
NCP1342
TYPICAL CHARACTERISTICS
0.126
0.255
0.124
0.250
0.122
0.245
0.118
ICC2 (mA)
ICC1 (mA)
0.120
0.116
0.114
0.112
0.240
0.235
0.230
0.110
0.225
0.108
0.106
−40
−20
0
20
40
60
80
100
0.220
−40
120
−20
0
20
40
60
80
100
120
100
120
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 33. ICC1 vs. Temperature
Figure 34. ICC2 vs. Temperature
1.075
28.35
1.070
28.3
1.065
VCC(OVP) (V)
ICC3 (mA)
1.060
1.055
1.050
1.045
1.040
28.25
28.2
28.15
1.035
1.030
−40
−20
0
20
40
60
80
100
28.1
−40
120
20
40
60
80
TJ, JUNCTION TEMPERATURE (°C)
Figure 35. ICC3 vs. Temperature
Figure 36. VCC(OVP) vs. Temperature
19.8
112.6
112.4
19.4
112.2
19.2
19
VBO(start) (V)
ICC(discharge) (mA)
0
TJ, JUNCTION TEMPERATURE (°C)
19.6
18.8
18.6
18.4
18.2
112
111.8
111.6
111.4
111.2
18
110
17.8
17.6
−40
−20
−20
0
20
40
60
80
100
120
110.8
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 37. ICC(discharge) vs. Temperature
Figure 38. VBO(start) vs. Temperature
www.onsemi.com
34
120
NCP1342
TYPICAL CHARACTERISTICS
98.2
90
80
CDRV = 1 nF
98
97.8
tDRV(rise) (ns)
VBO(stop) (V)
70
97.6
97.4
60
50
40
30
CDRV = 100 pF
20
97.2
97
−40
10
−20
0
20
40
60
80
100
0
−40
120
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
120
111.8
111.6
CDRV = 1 nF
111.4
30
fMAX1 (kHz)
tDRV(fall) (ns)
40
Figure 40. tDRV(rise) vs. Temperature
35
25
20
15
111.2
111
110.8
110.6
10
CDRV = 100 pF
110.4
5
−20
0
20
40
60
80
100
110.2
−40
120
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 41. tDRV(fall) vs. Temperature
Figure 42. fMAX1 vs. Temperature
367
120
73.45
366.5
73.4
366
73.35
365.5
73.3
fMAX3 (kHz)
fMAX2 (kHz)
20
TJ, JUNCTION TEMPERATURE (°C)
40
365
364.5
364
73.25
73.2
73.15
363.5
73.1
363
73.05
362.5
−40
0
Figure 39. VBO(stop) vs. Temperature
45
0
−40
−20
−20
0
20
40
60
80
100
120
73
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 43. fMAX2 vs. Temperature
Figure 44. fMAX3 vs. Temperature
www.onsemi.com
35
120
NCP1342
TYPICAL CHARACTERISTICS
32.5
63.6
32.4
63.5
VZCD(trig) (mV)
ton(MAX) (ms)
32.3
32.2
32.1
32
63.4
63.3
63.2
31.9
63.1
31.8
31.7
−40
−20
0
20
40
60
80
100
63
−40
120
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 46. VZCD(trig) vs. Temperature
120
12.95
25.6
12.9
25.55
VZCD(MAX) (V)
VZCD(HYS) (mV)
0
Figure 45. ton(MAX) vs. Temperature
25.65
25.5
25.45
12.85
12.8
12.75
25.4
25.35
−40
−20
−20
0
20
40
60
80
100
12.7
−40
120
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 47. VZCD(HYS) vs. Temperature
Figure 48. VZCD(MAX) vs. Temperature
0
120
198.8
−0.1
198.6
−0.3
Vfreeze (mV)
VZCD(MIN) (V)
−0.2
−0.4
−0.5
−0.6
−0.7
198.4
198.2
198
197.8
−0.8
−0.9
−40
−20
0
20
40
60
80
100
120
197.6
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 49. VZCD(MIN) vs. Temperature
Figure 50. Vfreeze vs. Temperature
www.onsemi.com
36
120
NCP1342
TYPICAL CHARACTERISTICS
1.31
104.2
1.308
104
103.8
1.304
Vjitter (mV)
fjitter (kHz)
1.306
1.302
1.3
103.2
1.296
103
−40
−20
0
20
40
60
80
100
102.8
−40
120
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
Figure 52. Vjitter vs. Temperature
402.5
3.09
402
3.08
401.5
3.07
3.06
3.05
120
401
400.5
400
399.5
3.04
−20
0
20
40
60
80
100
399
−40
120
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 53. VFault(OVP) vs. Temperature
Figure 54. VFault(OTP_in) vs. Temperature
920
45.1
918
45
120
44.9
IOTP (mA)
916
914
912
910
44.8
44.7
44.6
44.5
908
906
−40
0
TJ, JUNCTION TEMPERATURE (°C)
3.1
3.03
−40
−20
Figure 51. fjitter vs. Temperature
VFault(OTP_in) (mV)
VFault(OVP) (V)
103.4
1.298
1.294
VFault(OTP_out) (mV)
103.6
44.4
−20
0
20
40
60
80
100
120
44.3
−40
−20
0
20
40
60
80
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 55. VFault(OTP_out) vs. Temperature
Figure 56. IOTP vs. Temperature
www.onsemi.com
37
100
120
NCP1342
TYPICAL CHARACTERISTICS
1.731
1.55
1.545
1.54
RFault(clamp) (kW)
VFault(clamp) (V)
1.73
1.729
1.728
1.535
1.53
1.525
1.52
1.515
1.51
1.727
1.505
1.726
−40
1.495
−40
1.5
−20
0
20
40
60
80
100
120
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 57. VFault(clamp) vs. Temperature
Figure 58. RFault(clamp) vs. Temperature
24.5
120
1.39
24.45
1.385
24.4
24.3
tquiet (ms)
fMIN (kHz)
24.35
24.25
24.2
1.38
1.375
24.15
1.37
24.1
24.05
−20
0
20
40
60
80
100
1.365
−40
120
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 59. fMIN vs. Temperature
Figure 60. tquiet vs. Temperature
840
0.8
830
0.799
120
0.798
820
VILIM1 (V)
tZCD(blank) (ns)
24
−40
810
0.797
0.796
800
0.795
790
0.794
780
−40
−20
0
20
40
60
80
100
120
0.793
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 61. tZCD(blank) vs. Temperature
Figure 62. VILIM1 vs. Temperature
www.onsemi.com
38
120
NCP1342
40
1.201
39.9
1.2
39.8
1.199
39.7
tDT(MAX) (ms)
1.202
1.198
1.197
1.196
39.6
39.5
39.4
1.195
39.3
1.194
39.2
1.193
−40
−20
0
20
40
60
80
100
120
39.1
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
TJ, JUNCTION TEMPERATURE (°C)
Figure 63. VILIM2 vs. Temperature
Figure 64. tDT(MAX) vs. Temperature
399
398.5
398
Vskip (mV)
VILIM2 (V)
TYPICAL CHARACTERISTICS
397.5
397
396.5
396
−40
−20
0
20
40
60
80
100
TJ, JUNCTION TEMPERATURE (°C)
Figure 65. Vskip vs. Temperature
www.onsemi.com
39
120
120
NCP1342
PACKAGE DIMENSIONS
SOIC−8 NB
CASE 751−07
ISSUE AK
NOTES:
1. DIMENSIONING AND TOLERANCING PER
ANSI Y14.5M, 1982.
2. CONTROLLING DIMENSION: MILLIMETER.
3. DIMENSION A AND B DO NOT INCLUDE
MOLD PROTRUSION.
4. MAXIMUM MOLD PROTRUSION 0.15 (0.006)
PER SIDE.
5. DIMENSION D DOES NOT INCLUDE DAMBAR
PROTRUSION. ALLOWABLE DAMBAR
PROTRUSION SHALL BE 0.127 (0.005) TOTAL
IN EXCESS OF THE D DIMENSION AT
MAXIMUM MATERIAL CONDITION.
6. 751−01 THRU 751−06 ARE OBSOLETE. NEW
STANDARD IS 751−07.
−X−
A
8
5
S
B
0.25 (0.010)
M
Y
M
1
4
K
−Y−
G
C
N
DIM
A
B
C
D
G
H
J
K
M
N
S
X 45 _
SEATING
PLANE
−Z−
0.10 (0.004)
H
M
D
0.25 (0.010)
M
Z Y
S
X
J
S
SOLDERING FOOTPRINT*
1.52
0.060
7.0
0.275
4.0
0.155
0.6
0.024
1.270
0.050
SCALE 6:1
mm Ǔ
ǒinches
*For additional information on our Pb−Free strategy and soldering
details, please download the ON Semiconductor Soldering and
Mounting Techniques Reference Manual, SOLDERRM/D.
www.onsemi.com
40
MILLIMETERS
MIN
MAX
4.80
5.00
3.80
4.00
1.35
1.75
0.33
0.51
1.27 BSC
0.10
0.25
0.19
0.25
0.40
1.27
0_
8_
0.25
0.50
5.80
6.20
INCHES
MIN
MAX
0.189
0.197
0.150
0.157
0.053
0.069
0.013
0.020
0.050 BSC
0.004
0.010
0.007
0.010
0.016
0.050
0 _
8 _
0.010
0.020
0.228
0.244
NCP1342
PACKAGE DIMENSIONS
SOIC−9 NB
CASE 751BP
ISSUE A
2X
0.10 C A-B
D
D
A
0.20 C
2X
0.10 C A-B
4 TIPS
10
F
6
H
E
1
5
0.20 C
9X
B
5 TIPS
L2
b
0.25
A3
L
C
SEATING
PLANE
DETAIL A
NOTES:
1. DIMENSIONING AND TOLERANCING PER
ASME Y14.5M, 1994.
2. CONTROLLING DIMENSION: MILLIMETERS.
3. DIMENSION b DOES NOT INCLUDE DAMBAR
PROTRUSION. ALLOWABLE PROTRUSION
SHALL BE 0.10mm TOTAL IN EXCESS OF ’b’
AT MAXIMUM MATERIAL CONDITION.
4. DIMENSIONS D AND E DO NOT INCLUDE
MOLD FLASH, PROTRUSIONS, OR GATE
BURRS. MOLD FLASH, PROTRUSIONS, OR
GATE BURRS SHALL NOT EXCEED 0.15mm
PER SIDE. DIMENSIONS D AND E ARE DETERMINED AT DATUM F.
5. DIMENSIONS A AND B ARE TO BE DETERMINED AT DATUM F.
6. A1 IS DEFINED AS THE VERTICAL DISTANCE
FROM THE SEATING PLANE TO THE LOWEST
POINT ON THE PACKAGE BODY.
C A-B D
M
TOP VIEW
9X
h
X 45 _
0.10 C
0.10 C
M
A
A1
e
C
DETAIL A
SEATING
PLANE
END VIEW
SIDE VIEW
DIM
A
A1
A3
b
D
E
e
H
h
L
L2
M
MILLIMETERS
MIN
MAX
1.25
1.75
0.10
0.25
0.17
0.25
0.31
0.51
4.80
5.00
3.80
4.00
1.00 BSC
5.80
6.20
0.37 REF
0.40
1.27
0.25 BSC
0_
8_
RECOMMENDED
SOLDERING FOOTPRINT*
9X
1.00
PITCH
0.58
6.50
9X
1.18
1
DIMENSION: MILLIMETERS
*For additional information on our Pb−Free strategy and soldering
details, please download the ON Semiconductor Soldering and
Mounting Techniques Reference Manual, SOLDERRM/D.
ON Semiconductor and
are trademarks of Semiconductor Components Industries, LLC dba ON Semiconductor or its subsidiaries in the United States and/or other countries.
ON Semiconductor owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of ON Semiconductor’s product/patent
coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. ON Semiconductor reserves the right to make changes without further notice to any products herein.
ON Semiconductor makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ON Semiconductor assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
Buyer is responsible for its products and applications using ON Semiconductor products, including compliance with all laws, regulations and safety requirements or standards,
regardless of any support or applications information provided by ON Semiconductor. “Typical” parameters which may be provided in ON Semiconductor data sheets and/or
specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer
application by customer’s technical experts. ON Semiconductor does not convey any license under its patent rights nor the rights of others. ON Semiconductor products are not
designed, intended, or authorized for use as a critical component in life support systems or any FDA Class 3 medical devices or medical devices with a same or similar classification
in a foreign jurisdiction or any devices intended for implantation in the human body. Should Buyer purchase or use ON Semiconductor products for any such unintended or unauthorized
application, Buyer shall indemnify and hold ON Semiconductor and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and
expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such
claim alleges that ON Semiconductor was negligent regarding the design or manufacture of the part. ON Semiconductor is an Equal Opportunity/Affirmative Action Employer. This
literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
Literature Distribution Center for ON Semiconductor
19521 E. 32nd Pkwy, Aurora, Colorado 80011 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: [email protected]
◊
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5817−1050
www.onsemi.com
41
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
For additional information, please contact your local
Sales Representative
NCP1342/D
Similar pages