TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25℃ otherwise noted
Model
Number
FED40-24S3P3W
FED40-24S05W
FED40-24S12W
FED40-24S15W
FED40-24S24W
FED40-24D12W
FED40-24D15W
FED40-24D24W
FED40-48S3P3W
FED40-48S05W
FED40-48S12W
FED40-48S15W
FED40-48S24W
FED40-48D12W
FED40-48D15W
FED40-48D24W
FED40-110S3P3W
FED40-110S05W
FED40-110S12W
FED40-110S15W
FED40-110S24W
FED40-110D12W
FED40-110D15W
FED40-110D24W
Input Range
Output Voltage
Output Current
@Full Load
Input Current
@ No Load
Efficiency
Maximum
Capacitor Load (1)
VDC
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
43 ~ 160
VDC
3.3
5
12
15
24
±12
±15
±24
3.3
5
12
15
24
±12
±15
±24
3.3
5
12
15
24
±12
±15
±24
mA
10000
8000
3333
2666
1666
±1666
±1333
±833
10000
8000
3333
2666
1666
±1666
±1333
±833
10000
8000
3333
2666
1666
±1666
±1333
±833
mA
15
15
15
15
15
15
15
15
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
%
90
91
92
92
91
90
90
91
90
91
92
92
91
90
90
91
88
89
90.5
91
90
89
89
91
µF
26600
20000
3900
2600
1300
± 2600
± 1600
±650
26600
20000
3900
2600
1300
± 2600
± 1600
±650
26600
20000
3900
2600
1300
± 2600
± 1600
±650
PART NUMBER STRUCTURE
FED40 Series Name
48
Input
Voltage
(VDC)
24: 9~36
48: 18~75
110: 43~160
S
Output
Quantity
S: Single
D: Dual
1
05
Output
Voltage
(VDC)
3P3: 3.3
05: 5
12: 12
15: 15
24: 24
12: ±12
15: ±15
24: ±24
W Input
Range
4:1
N
HS
Remote Control
Option
Heat-sink
: Positive logic
N: Negative logic
www.PDUKE.com
: No Heat-sink
HS Heat-sink
HC Heat-sink with Clamp
2014/10/14
FED40W
INPUT SPECIFICATIONS
Parameter
Conditions
24Vin(nom)
48Vin(nom)
110Vin(nom)
24Vin(nom)
48Vin(nom)
110Vin(nom)
24Vin(nom)
48Vin(nom)
110Vin(nom)
Power up
Remote ON/OFF
24Vin(nom)
48Vin(nom)
110Vin(nom)
Operating input voltage range
Start-up voltage
Shutdown voltage
Start up time
Constant resistive load
Input surge voltage
1 second, max.
Input filter
Remote ON/OFF
Referred to –Vin pin
OUTPUT SPECIFICATIONS
Parameter
Positive logic
DC-DC ON
(Standard)
DC-DC OFF
DC-DC ON
Negative logic
(Option)
DC-DC OFF
Input current of Ctrl pin
Remote off input current
Conditions
Voltage accuracy
Line regulation
Load regulation
Low Line to High Line at Full Load
No Load to Full Load
Cross regulation
Voltage adjustability
Asymmetrical load 25%/100% FL
Single output
Ripple and noise
Measured by 20MHz bandwidth
With a 0.1µF/50V X7R MLCC
Temperature coefficient
Transient response recovery time
Over voltage protection
Over load protection
Short circuit protection
3.3Vout
5Vout
12Vout
15Vout
24Vout
% of Iout rated; Hiccup mode
Isolation voltage
1 minute
Isolation resistance
Isolation capacitance
Switching frequency
Safety meets
500VDC
2
Typ.
Max.
9
18
43
24
48
110
36
75
160
9
18
43
-0.5
Min.
Conditions
Input to Output
Input (Output) to Case
www.PDUKE.com
VDC
VDC
ms
50
100
VDC
170
Pi type
Open or 3 ~ 12VDC
Short or 0 ~ 1.2VDC
Short or 0 ~ 1.2VDC
Open or 3 ~ 12VDC
0.5
mA
3
mA
Typ.
-1.0
-0.2
-0.5
-1.0
-5.0
-10
-10
75
100
150
Max.
Unit
+1.0
+0.2
+0.5
+1.0
+5.0
+10
+20
100
125
200
+0.02
%
%
%
%
%
mVp-p
%/℃
250
µs
3.9
6.2
15
VDC
20
30
150
%
Continuous, automatics recovery
Min.
Typ.
1600
1600
1
225
MIL-HDBK-217F, Full load.
Unit
VDC
8
16
40
60
60
-0.02
25% load step change
Zener diode clamp
GENERAL SPECIFICATIONS
Parameter
Case material
Base material
Potting material
Weight
MTBF
Single
Dual
Dual
3.3Vout, 5Vout, 12Vout
15Vout, 24Vout
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
Min.
Max.
Unit
VDC
250
GΩ
pF
kHz
UL60950-1
EN60950-1
IEC60950-1
EN50155
Copper
FR4 PCB
Silicone (UL94 V-0)
32g (1.13oz)
9.073 x 105 hrs
1500
275
2014/10/14
FED40W
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Maximum case temperature
Over temperature protection
Storage temperature range
Thermal impedance (1)
Conditions
Min.
Typ.
-40
Max.
Unit
+85
+105
+115
-55
Vertical direction by natural convection (20LFM)
Without Heat-sink
With Heat-sink
Thermal shock
Shock
Vibration
Relative humidity
+125
10.8
10.3
/W
MIL-STD-810F
EN61373, MIL-STD-810F
EN61373, MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (2)
ESD
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
Conditions
EN55011,EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level
Air ± 8kV and Contact ± 6kV
20 V/m
± 2kV
± 2kV
10 Vr.m.s
Class A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1.
2.
3.
Test by minimum input and constant resistive load.
The standard modules meets EMI Class A or Class B with external components. For further information, please contact with P-DUKE.
The external input components are required if the module has to meet EN61000-4-4, EN61000-4-5.
The FED40-24W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS
(SMDJ58A, 58V, 3000Watt peak pulse power) to connect in parallel.
The FED40-48W recommended an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220µF/100V) and a TVS
(SMDJ120A,120V, 3000Watt peak pulse power) to connect in parallel.
The FED40-110W recommended an aluminum electrolytic capacitor (Ruby-con BXF series, 68µF/200V 3pcs in parallel) and a TVS
(SMDJ90A, 90V, 3000Watt peak pulse power 2pcs in series connection ) to connect in parallel
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
3
FED40-48S05W Derating Curve
FED40-48S05W Derating Curve with Heat-sink
FED40-48S05W Efficiency VS Input Voltage
FED40-48S05W Efficiency VS Output Load
www.PDUKE.com
2014/10/14
FED40W
MECHANICAL DRAWING
PIN CONNECTION
PIN
SINGLE
1
+ Vin
2
- Vin
3
Ctrl
4
+ Vout
5
- Vout
6
Trim
DUAL
+ Vin
- Vin
Ctrl
+ Vout
Common
- Vout
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by
using the method shown below.
TRIM UP
TRIM DOWN
6
6
RU
5
RD
4
1. All dimensions in inch (mm)
2. Tolerance :x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
3. Pin pitch tolerance ±0.01 (0.25)
4. Pin dimension tolerance ±0.004(0.1)
4
www.PDUKE.com
2014/10/14