Series AM3Q-Z 3 Watt | DC-DC Converter FEATURES: RoHS Compliant Wide 2:1 input range High Efficiency up to 85% Continuous short circuit Operating Temperature -40ºC to 85ºC Input / Output Isolation of 500VAC No Tantalum capacitors used inside Over voltage protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) 4.5-9 4.5-9 4.5-9 9-18 9-18 9-18 18-36 18-36 18-36 36-75 36-75 36-75 5 12 15 5 12 15 5 12 15 5 12 15 600 250 200 600 250 200 600 250 200 600 250 200 500 500 500 500 500 500 500 500 500 500 500 500 100 100 100 100 100 100 220 220 220 220 220 220 67 70 70 70 74 74 71 75 75 71 76 76 Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) 4.5-9 4.5-9 9-18 9-18 18-36 18-36 36-75 36-75 ±12 ±15 ±12 ±15 ±12 ±15 ±12 ±15 ±130 ±100 ±130 ±100 ±130 ±100 ±130 ±100 500 500 500 500 500 500 500 500 ±220 ±100 ±220 ±100 ±220 ±100 ±220 ±100 82 82 84 85 84 85 84 84 AM3Q-0505SZ AM3Q-0512SZ AM3Q-0515SZ AM3Q-1205SZ AM3Q-1212SZ AM3Q-1215SZ AM3Q-2405SZ AM3Q-2412SZ AM3Q-2415SZ AM3Q-4805SZ AM3Q-4812SZ AM3Q-4815SZ Models Dual output Model AM3Q-0512DZ AM3Q-0515DZ AM3Q-1212DZ AM3Q-1215DZ AM3Q-2412DZ AM3Q-2415DZ AM3Q-4812DZ AM3Q-4815DZ NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal 5 12 24 48 Typical 4.5-9 9-18 18-36 36-75 π (Pi) Network Filter Start up time No Load Input Current Input reflected current www.aimtec.com F 051e R12.C 20 25 20 Tel: +1 514 620 2722 1 of 3 Maximum Units VDC ms mA mA Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3Q-Z 3 Watt | DC-DC Converter Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 3sec 500 50 Maximum Units 500 VAC MOhm pF Output Specifications Parameters Conditions Typical Voltage accuracy Cross Regulation (Dual Output Models) Over voltage protection 25% load on one output 100% load on the other output LL-HL Load:0-100% unbalanced 20MHz Bandwidth Units % ±5 % 5 12 15 ±12 ±15 Continuous Auto Recovery ±0.5 ±1 ±0.02 50 0 Zener Diode Clamp Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Minimum Load Current Maximum ±1 6.5 12 18 ±15 ±18 V % of Vin % %/oC mV p-p % of Max General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Transient recovery deviation Conditions Typical 100% load Derating above 60ºC 100 Maximum Units 100 KHz o C o C o C -40 to +85 -40 to +125 Free Air Convection 95 Nickel Coated Copper 16 1.37 x 0.90 x 0.28 inches 35.00 x 23.00 x 7.00 mm >1.6Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C ) ±3 % RH g % Safety Specifications Parameters Standards Designed to meet IEC/EN 60950-1 Pin Out Specifications Pin Single 1 -V Input 2 +V Input 3 +V Output 4 NP 5 -V Output NP: Not Populated www.aimtec.com F 051e R12.C Dual -V Input +V Input +V Output Common -V Output Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM3Q-Z 3 Watt | DC-DC Converter 7.62 (0.30) 7.62 (0.30) 7.62 (0.30) 7.00 (0.28) 2.70 (0.11) 4.40 (0.17) 6.60 (0.26) 23.00 (0.90) 3.88 (0.15) Dimensions Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.C Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only