PolySwitch® PTC Devices PRODUCT: AGRF400 DOCUMENT: SCD25231 REV LETTER: D REV DATE: July 26, 2016 PAGE NO.: 1 OF 2 Overcurrent Protection Device Specification Status: Released Electrical Rating Voltage: 16VDC MAX Insulating Material: Cured, Flame Retardant Epoxy Polymer Lead Material: 20 AWG Tin Plated Copper (0.8 mm [0.032] nom. diameter) Part Marking: Manufacturer’s Mark G4 and Part Identification Lot Identification TABLE I. INSTALLATION ENVELOPE DIMENSIONS: A m m: in*: MIN -- B MAX 8.9 MIN -- C MAX 14.1 -(0.35) -(0.56) *Rounded off approximation MIN 4.3 MAX 5.8 MIN 7.6 D MAX -- MIN -- E MAX 3.0 F TYP 1.2 MIN -- G MAX 3.1 (0.17) (0.23) (0.30) -- -- (0.12) (0.05) -- (0.12) TABLE II. PERFORMANCE RATINGS: CURRENT RATINGS AMPS AT 25°C HOLD HOLD AT AT R1 MAX RA MAX 4.0 3.0 TIME TO TRIP INITIAL RESISTANCE TRIP SECONDS AT 25°C, 20 A MAX OHMS AT 25°C MIN MAX 7.6 2.0 Reference Documents: Precedence:This Effectivity: CAUTION: 0.0186 R1 MAX POST TRIP RESISTANCE STANDARD TRIP OHMS AT 25C RA MAX TRIPPED-STATE POWER DISSIPATION OHMS AT 25C WATTS AT 25°C TYP 0.061 0.085 2.5 0.0390 PS400, PS300 (Ref for R1 MAX) specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame. Materials Information ROHS Compliant ELV Compliant Pb-Free Halogen Free* HF *Halogen Free refers to: Br≤900ppm, Cl≤900ppm,Br+Cl≤1500ppm. © 2016 Littelfuse,Inc. Specifications are subject to change without notice. Revised July 26,2016 littelfuse.com PolySwitch® PTC Devices Overcurrent Protection Device PRODUCT: AGRF400 DOCUMENT: SCD25231 REV LETTER: D REV DATE: July 26, 2016 PAGE NO.: 2 OF 2 TABLE III. AUTOMOTIVE SPECIFIC STRESS TESTS AND TEST CONDITIONS: ELECTRICAL STRESS TESTS TEST CONDITIONS (see note 2) ESD Voltage Withstand (see note 1) Short Circuit Fault Current Durability 25kV Fault Current Durability 350 cycles, 16V/100A End-of-life Mode Verification 1750 cycles, 16V/100A Jump Start Endurance (see note 1) Load Dump Endurance (see note 1) 3 cycles, 26V, 1 minute duration 25 cycles, 16V, 200A 10 cycles, 86.5V Note 1: The PolySwitch devices are tested in series with a load resistance and the voltages specified in the test conditions are shared between the PolySwitch device and the load resistance as specified in PS400. Note 2: Please refer to Appendix A of PS400 for the detailed test procedures Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, lifesaving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. © 2016 Littelfuse,Inc. Specifications are subject to change without notice. Revised July 26,2016 littelfuse.com