Ensign L050-1-510X Power transformer commander class Datasheet

COMMANDER CLASS - CHASSIS MOUNT WITH LEAD WIRES POWER TRANSFORMER
1.
Standard 6” Lead Length
2.
3.
Electrical Specifications
A. Maximum Power: 50VA
B. Input Voltage and Frequency: 115V, 115/230V or 230V
50/60Hz
C. Voltage Regulation: 10% TYP @ full load to no load
D. Temperature Rise: 40C TYP
E. Insulation Resistance: < 1 MEG ohm
F. Hi-Pot: 2500Vrms 1 minute @ Pri to Sec
2500Vrms 1 minute @ Pri to Core
1500Vrms 1 minute @ Sec to Core
Marking: Ensign Corp, part number (see table), date code
Safety:
UL/cUL 5085-2 Recognized (File E47299)
UL 1446 Recognized Insulation System (File E95662)
Part Number
Primary Schematics
Single Input
(Specify 115V
or 120V
Single Input
(Specify 230V
or 240V)
Single Input
(277V)
Tapped Input
WHT=COM
BLK=120
VIO=277V
Dual Input
(Specify
115/230V or
120/240V)
115V
115/230V
230V
Secondary
L050-1-510X
L050-2-510X
L050-3-510X
10VCT @ 5.0A
L050-1-512X
L050-2-512X
L050-3-512X
12.6VCT @ 4.0A
L050-1-516X
L050-2-516X
L050-3-516X
16VCT @ 3.1A
L050-1-520X
L050-2-520X
L050-3-520X
20VCT @ 2.5A
L050-1-524X
L050-2-524X
L050-3-524X
24VCT @ 2.1A
L050-1-528X
L050-2-528X
L050-3-528X
28VCT @ 1.8A
L050-1-536X
L050-2-536X
L050-3-536X
36VCT @ 1.4A
L050-1-548X
L050-2-548X
L050-3-548X
48VCT @ 1.0A
L050-1-556X
L050-2-556X
L050-3-556X
56VCT @ 900mA
L050-1-620X
L050-2-620X
L050-3-620X
120VCT @ 410mA
Secondary Schematics
POWER TRANSFORMER
COMMANDER CLASS
Single
Output
Center-Tapped
Output
Dual
Output
CONTENTS OF THIS DRAWING ARE SUBJECT TO
CHANGE WITHOUT PRIOR NOTICE
Ensign Corporation
L050-1-XXXX
L050-2-XXXX
L050-3-XXXX
Dim: Inches
Sheet 1 of 1
201 ENSIGN RD., BELLEVUE, IA 52031
PROPRIETARY NOTICE: THIS DRAWING PRINT OR DOCUMENT AND SUBJECT MATTER DISCLOSED HEREIN ARE PROPRIETARY ITEMS TO WHICH ENSIGN RETAINS
THE EXCLUSIVE RIGHT OF DISSEMINATION, MANUFACTURE AND SALE. THIS DRAWING, PRINT OR DOCUMENT IS SUBMITTED IN CONFIDENCE FOR CONSIDERATION
BY THE RECIPIENT ALONE UNLESS PERMISSION FOR FURTHER DISCLOSURE IS EXPRESSLY GRANTED IN WRITING