Click on Series name for product info on aimtec.com Series AME40-CJZ 40 Watt | AC-DC / DC-DC Converter Picture coming soon FEATURES: I/O Isolation 3000VAC Operating Temp: -40 °C to +70 °C Input: 85-264VAC/47-440Hz, or 100-370VDC Over current, Over Voltage Protection Continuous Short circuit protection Low no load consumption ≤0.5W Efficiency up to 84% Output Voltage adjustment Models Single output Model AME40-3.3SCJZ AME40-5SCJZ AME40-9SCJZ AME40-12SCJZ AME40-15SCJZ AME40-24SCJZ Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 85-264/47-440 100-370 100-370 100-370 100-370 100-370 100-370 Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-440 85-264/47-440 85-264/47-440 100-370 100-370 100-370 Output Voltage (V) Output Current max (A) 3.3 5 9 12 15 24 Maximum capacitive Load (µF) Efficiency 230VAC (%) 60,000 40,000 12,000 9000 7000 2000 78 82 84 84 84 84 Maximum capacitive Load (µF) Efficiency 230VAC (%) ±12,000 ±4400 ±1000 82 84 84 Maximum capacitive Load (µF) Efficiency 230VAC (%) 10,000/470 10,000/400 82 82 8 8 4.44 3.33 2.66 1.66 Models Dual output Model AME40-5DCJZ AME40-12DCJZ AME40-15DCJZ Output Voltage (V) Output Current max (A) ±5 ±12 ±15 ±4 ±1.66 ±1.33 Models Asymmetric Separated Dual output Model AME40-512DCJZ AME40-524DCJZ Input Voltage (VAC/Hz) Input Voltage (VDC) 85-264/47-440 85-264/47-440 100-370 100-370 Output Voltage (V) Output Current max (A) 5/12 5/24 5/1.25 5/0.625 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 30 50 Maximum 1 0.6 Units A A A A Output Specifications Parameters Voltage accuracy Line regulation www.aimtec.com F 052e R8.A Conditions Single, Dual and Main Dual Asymmetrical output Auxiliary Dual Asymmetrical output Single, Dual and Main Dual Asymmetrical output Auxiliary Dual Asymmetrical output Tel: +1 514 620 2722 6832) 1 of 7 Typical Maximum Units ±2 % ±5 ±0.5 % % ±1.5 % Toll free: + 1 888 9 AIMTEC (924 North America only Series AME40-CJZ 40 Watt | AC-DC / DC-DC Converter Output Specifications (continued) Parameters Load regulation (single output) Load Regulation (dual output) Load Regulation (asymmetric separated output) Cross regulation (dual output) Cross regulation (asymmetric separated output) Ripple & Noise Conditions Typical 0-100% load 10-100% Balanced load 25-100% Balanced load, main output 25-100% Balanced load, auxiliary output ±1 ±2 ±2 ±5 ±5 ±1 ±7 50 15 80 Hold-up time Voltage adjustment range Main output Auxiliary output 115VAC, 20MHz bandwidth 230VAC, 20MHz bandwidth Single output only Maximum Units ±10 % % % % % % % mV p-p ms ms % of Vout Rated Units 3000 500 VAC VAC ±8 100 Isolation Specifications Parameters Conditions Tested I/O voltage Isolation voltage between Main and Auxiliary output Isolation Resistance Typical 60 sec 60 sec >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class II Over current protection ≥110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery oC Operating temperature See derating curve -40 to +70 oC Storage temperature -40 to +85 oC Maximum Case temperature 100 Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 225 g Dimensions (L x W x H) 3.5 x 2.5 x 0.98 inches 89.0 x 63.5 x 25.0 mm MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052e R8.A cULus, CE (single output models only) Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC/EN/UL 60950-1 EN55022, class B IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11 Class 2 Tel: +1 514 620 2722 6832) 2 of 7 Toll free: + 1 888 9 AIMTEC (924 North America only Series AME40-CJZ 40 Watt | AC-DC / DC-DC Converter 89.00 (3.50) 6 5 4 3 1 3.81 (0.15) 3.85 (0.15) 15.24 (0.60) 55.88 (2.20) Bottom View 12.70 (0.50) 7 2 63.50 (2.50) 3.81 (0.15) 3.81 (0.15) Dimensions 81.30 (3.20) 3.85 (0.15) DIV: 10.00 (0.40) 5Ø 1.70 (Ø 0.07) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter ± 0.10 (± 0.004) 25.00 (0.98) Side View 6.00 (0.24) 1.20 (0.05) Pin Out Specifications Pin Single Dual Asymmetric Dual 1 2 3 4 5 6 7 AC Input (L) AC Input (N) +V Output No pin -V Output No pin Trim AC Input (L) AC Input (N) +V Output No pin Common No pin -V Output AC Input (L) AC Input (N) +V Output 2 +V Output 1 -V Output 2 -V Output 1 No pin Deratings AME40-3.3SCJZ & AME40-5SCJZ AME40-9SCJZ, AME40-12SCJZ & AME40-15SCJZ Free Air Convection Free Air Convection 80 60 100 Output Power (%) Output Power (%) 100 Safe Operating Area 100% load 100-264VAC 40 25 80 70 60 Safe Operating Area 100% load 100-264VAC 45 40 20 20 0 0 -30 - 40 -20 0 20 45 40 70 80 60 100 -30 - 40 -20 F 052e R8.A 20 40 55 60 70 80 100 Ambient Temperature º C Ambient Temperature º C www.aimtec.com 0 Tel: +1 514 620 2722 6832) 3 of 7 Toll free: + 1 888 9 AIMTEC (924 North America only Series AME40-CJZ 40 Watt | AC-DC / DC-DC Converter AME40-24SCJZ All dual output models Free Air Convection Free Air Convection 80 60 100 Output Power (%) Output Power (%) 100 Safe Operating Area 100% load 100-264VAC 40 60 Safe Operating Area 100% load 100-264VAC 50 40 20 20 0 0 - 40 80 -20 0 20 40 55 70 80 60 -30 - 40 -20 100 0 20 40 50 60 70 80 100 Ambient Temperature º C Ambient Temperature º C Free Air Convection at 25°C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 85 100 (100) (120) 264 (370) Input Voltage VAC (VDC) Typical application circuits FUSE 3.15A Single Output NTC 4 AC L AC L MOV S14K350 AC N www.aimtec.com F 052e R8.A + Vout + AC AC N DC LCM 10‐30mH 3 C1 C2 1µF/50V Tel: +1 514 620 2722 6832) 4 of 7 TVS1 ‐ Vout Toll free: + 1 888 9 AIMTEC (924 North America only Series AME40-CJZ 40 Watt | AC-DC / DC-DC Converter Dual Output FUSE 3.15A/300V NTC + Vout AC L AC L MOV S14K350 AC AC N DC C3 1µF/50V AC N FUSE 3.15A/300V Com C2 + Vout + TVS 1 C4 + Com TVS 2 ‐ Vout ‐ Vout Asymmetric Dual Output NTC + AC L AC L Vout 1 MOV S14K350 AC N C3 1µF/50V C2 C4 680 µF 220 µF 220 µF 120 µF TVS1 7V 12V 20V 30V 7V 20V 7V 7V + Vout 1 + TVS 1 C4 ‐ Vout 1 + Vout 2 + ‐ AC N C2 680 µF 330 µF 220 µF 120 µF 680 µF 220 µF 680 µF 680 µF C1 1µF/50V ‐ DC + AC Vout 2 Model Single 3.3 & 5 Vout Single 9 Vout Single 12 & 15 Vout Single 24 Vout Dual ±5 Vout Dual ±12 & ±15 Vout Dual 5/12 Vout Dual 5/24 Vout C1 1µF/50V TVS 2 ‐ Vout 2 TVS2 7V 20V 20V 30V Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor www.aimtec.com F 052e R8.A Variable Potentiometer Tel: +1 514 620 2722 6832) 5 of 7 Toll free: + 1 888 9 AIMTEC (924 North America only Series AME40-CJZ 40 Watt | AC-DC / DC-DC Converter Leave open if not used. AME40‐3.3SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % 1 2 3 4 5 6 7 8 9 10 3.27 3.23 3.2 3.17 3.14 3.1 3.07 3.04 3 2.97 109.727 50.913 35.75 27.244 21.8 17 14.465 12.5 10.478 9.277 1 3.33 2 3.37 3 3.4 4 3.43 5 3.47 6 3.5 7 3.53 8 3.56 9 3.6 10 3.63 105.286 38.158 25.571 19.108 14.184 11.828 10.104 8.789 7.455 6.67 1 4.95 160.7 2 4.9 78.2 3 4.85 50.7 4 4.8 36.95 5 4.75 28.7 6 4.7 23.2 7 4.65 19.271 8 4.6 16.325 9 4.55 14.033 10 4.5 12.2 1 5.05 164 2 5.1 81.5 3 5.15 54 4 5.2 40.25 5 5.25 32 6 5.3 26.5 7 5.35 22.571 8 5.4 19.625 9 5.45 17.333 10 5.5 15.5 Vout (VDC) 1 8.91 254.795 1 9.09 2 8.82 141.96 2 9.18 3 8.73 97.332 3 9.27 4 8.64 73.419 4 9.36 5 8.55 58.515 5 9.45 6 8.46 48.336 6 9.54 7 8.37 40.943 7 9.63 8 8.28 35.329 8 9.72 9 8.19 30.921 9 9.81 10 8.1 27.369 10 9.9 Rt up (KΩ) 187.839 76.19 47.509 34.368 26.829 21.939 18.511 15.974 14.021 12.471 Vout (VDC) 1 11.88 183.233 1 12.12 2 11.76 111.59 2 12.24 3 11.64 79.474 3 12.36 4 11.52 61.246 4 12.48 5 11.4 49.499 5 12.6 6 11.28 41.299 6 12.72 7 11.16 35.249 7 12.84 8 11.04 30.602 8 12.96 9 10.92 26.921 9 13.08 10 10.8 23.933 10 13.2 Rt up (KΩ) 211.778 57.03 32.596 22.642 17.238 13.845 11.516 9.819 8.527 7.511 1 2 3 4 14.85 14.7 14.55 14.4 492.012 220.375 140.481 102.271 1 2 3 4 15.15 15.3 15.45 15.6 5 14.25 79.872 5 15.75 6 14.1 65.153 6 15.9 7 13.95 54.742 7 16.05 8 13.8 46.989 8 16.2 9 13.65 40.991 9 16.35 10 13.5 36.214 10 16.5 24 19.833 16.857 14.625 12.889 11.5 Vout (VDC) Rt up (KΩ) AME40‐5SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) AME40‐9SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % AME40‐12SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % AME40‐15SCJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) www.aimtec.com F 052e R8.A 124 61.5 40.667 30.25 Tel: +1 514 620 2722 6832) 6 of 7 Toll free: + 1 888 9 AIMTEC (924 North America only Series AME40-CJZ 40 Watt | AC-DC / DC-DC Converter AME40‐24SCJZ Trim down % Vout (VDC) 1 2 3 4 5 6 23.76 23.52 23.28 23.04 22.8 22.56 471.081 287.942 205.845 159.249 129.221 108.258 1 2 3 4 5 6 24.24 24.48 24.72 24.96 25.2 25.44 Rt up (KΩ) 239.556 Vout (VDC) Rt down (KΩ) Trim up % 64.606 36.982 25.728 19.619 15.783 7 22.32 92.793 7 25.68 8 22.08 80.914 8 25.92 9 21.84 71.504 9 26.16 10 21.6 63.865 10 26.4 13.15 11.232 9.771 8.622 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 6832) 7 of 7 Toll free: + 1 888 9 AIMTEC (924 North America only