Willow AS4 5a to 600 vac sip package Datasheet

Series AS4
5A to 600 Vac SIP Package
DC Control
Part Number
Description
AS24D4E/R
4A, 275 Vac
AS24D4E-X1
4A, 275 Vac
AS24D4E-X2
4A, 275 Vac
Part Number Explanation
AS
46
D
Series
Line Voltage1
4
E
Control Range3
Switch Type2
Output Current
• Industry standard package
• Tight zero-cross window for low EMI
• Low input current draw
• High dv/dt capability
• Integral transient voltage protection
• High immunity to surges
NOTES
1) Line Voltage (nominal): 46 = 460 Vac
2) Switch Type: D = Zero-cross turn-on
3) Control Range: E = 4–30 Vdc (5-30 Vdc for AS60D4E)
4) RoHS Compliant = /R (AS24D4E/R)
MECHANICAL SPECIFICATION
Bottom View
.30
(7.62)
.39
(10.2)
.10 (2.58)
.39 (10.2)
1.70 (43.2)
input
4-30 Vdc
4- 3+
.30
(7.63)
50A2s
output
230 Vac 4A
2
1
.49
.40
(12.7) (10.16)
DESCRIPTION
The AS 4-amp and 5-amp solid-state single inline (SIP)
four-pin relays are designed for mounting on a printed
circuit board. The relays offer built-in voltage protection
and can withstand very high current overloads. The
Series AS4 relays have a low zero-cross window. The
compact size and triac output make the AS relay the
perfect retrofit for electromechanical relays.
APPLICATIONS
• Interface applications
• Vending machines
• Light/lamp control
• HVAC controls
1.0 (25.4)
.19 (6.5) Ø1
.20
(5.08)
FEATURES/BENEFITS
.30
(7.62)
APPROVALS
UL File Number: E128555. (Except AS60D4E)
WEIGHT: 1.06 oz. (30g)
Figure 1 — AS relays; dimensions in inches (mm)
BLOCK DIAGRAM
(Control LED available on AS46R4F-02 only.)
ELECTRICAL SPECIFICATIONS
Min
Max
Units
-40
80
°C
Storage Temperature
-40
120
Input-Output Isolation
4000
Operating Temperature
Input-Output Capacitance
© 2016 TELEDYNE RELAYS
°C
Vrms
3
Figure 2a — All AS relays except AS60D4E
pF
(800) 284-7007 • www.teledynerelays.com
AS4 Page 1
AS4\092016\Q3
Series AS4
5A to 600 Vac SIP Package
DC Control
INPUT (CONTROL) SPECIFICATIONS
Min
Max
OUTPUT(CONTROL) SPECIFICATIONS (Continued)
Units
Control Range
Min
Max
Units
Maximum Surge Current Rating (Non-Repetitive)
AS24D4E/R
4
30
Vdc
(See Figure 5a and Figure 5b)
AS46D4E
4
30
Vdc
AS24D4E/R
100
Apeak
AS60D4E
5
30
Vdc
AS46D4E
100
Apeak
AS60D4E
120
Apeak
On-State Voltage Drop
1.6
V
Zero-Cross Window (Typical)
±12
V
Input Current Range
AS24D4E/R
3
30
mA
AS46D4E
3
30
mA
AS60D4E
3
30
mA
Must Turn-Off Voltage
Off-State Leakage Current (60Hz)
AS24D4E/R
0.8
Vdc
AS24D4E/R
0.3
mArms
AS46D4E
0.8
Vdc
AS46D4E
0.3
mArms
AS60D4E
1
Vdc
AS60D4E
1
mArms
AS24D4E/R
1,000
Ohms
AS24D4E/R
8.3
ms
AS46D4E
1,000
Ohms
AS46D4E
8.3
ms
AS60D4E
1,000
Ohms
AS60D4E
8.3
ms
8.3
ms
Input Resistance (Typical)
Turn-On Time (60Hz)
Turn-Off Time (60Hz)
OUTPUT (CONTROL) SPECIFICATIONS
Min
Max
Units
Off-State dv/dt
500
AS24D4E/R
12
275
Vrms
Operating Frequency
10
AS46D4E
12
460
Vrms
AS60D4E
24
600
Vrms
V/ųs
Operating Range
Peak Voltage (Clamping Voltage)
AS24D4E/R
600(450) Vpeak
AS46D4E
900(720) Vpeak
AS60D4E
1200
Vpeak
440
Hz
AS24D4E/R
50
A²S
AS46D4E
50
A²S
AS46D4E
72
A²S
I²T for Match Fusing (<8.3ms)
TYPICAL APPLICATIONS
L1
L1
Load Current Range
AS24D4E/R
.005
4
Arms
AS46D4E
.005
4
Arms
AS60D4E
.005
5
Arms
)LJXUHD
AS4 Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2016 TELEDYNE RELAYS
AS4\092016\Q3
Series AS4
5A to 600 Vac SIP Package
DC Control
Load Current (Arms)
LOAD CURRENT DERATING CURVE
Ambient Temperature (C)
Figure 4 — Thermal curves
Overload Current (A)
SURGE CURRENT RATING
Number of Cycles
Figure 5a — Non-repetitive surge current
NOTES:
1. Electrical specifications at 25C unless otherwise specified.
2. For 800Hz applications, contact factory.
3. For additional/custom options, contact factory.
© 2016 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
AS4 Page 3
AS4\092016\Q3
Series AS4
5A to 600 Vac SIP Package
DC Control
PEAK CURRENT (Apk)
400
350
300
250
200
150
1
2
100
50
0.01
0.1
1
PEAK CURRENT (Apk)
SURGE CURRENT
250
200
150
No repetive surge current without voltage reapplied.
100
1
2
50
Repetive surge current with voltage reapplied.
0
0.01
10
0.1
1
TIME (s)
TIME (s)
Figure 4c — 35A output current
Figure 4b — 25A output current
10
THERMAL CURVES
Power Dissipation (W)
1K/W
1,5K/W
duty cycle 90%
45
40
50
40
Full on State
35
35
3K/W
30
30
50% on State
25
4K/W
25
20
20
6K/W
15
15
10
10
12K/W
5
0
5 10 15 20 25 30 35 40 45 50
2K/W
0
0 10 20 30 40 50 60 70 80 90 100
1,5K/W
1K/W
30
duty cycle 90%
3K/W
25
Full on State
25
4K/W
20
20
6K/W
15
15
10
10
12K/W
5
5
50% on State
5
I max = 48A @ Tcase = 85°C
I max = 34A @ Tcase = 100°C
0
30
45
2K/W
Power Dissipation (W)
50
0
0
5
10
15
20
25
0
0 10 20 30 40 50 60 70 80 90 100
Load Current (A)
Load Current (A)
Figure 5c — 35A output power
Figure 5b — 25A output power
12°C/W corresponds to a relay without heat sink
6°C/W corresponds to a relay mounted on a DIN-rail adaptor (Teledyne P/N DL12)
AS4 Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2016 TELEDYNE RELAYS
AS4\092016\Q3
Similar pages