ACS713 Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor Features and Benefits ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ Description Low-noise analog signal path Device –3 dB point is set via the new FILTER pin Total output error 1.5% at TA= 25°C, 4% at –40°C to 85°C Small footprint, low-profile SOIC8 package 1.2 mΩ internal conductor resistance 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 5.0 V, single supply operation 50 kHz bandwidth 133 to 185 mV/A output sensitivity 5 µs output rise time in response to step input current Output voltage proportional to sensed DC current Factory-trimmed for accuracy Extremely stable output offset voltage Nearly zero magnetic hysteresis Ratiometric output from supply voltage The Allegro® ACS713 provides economical and precise solutions for DC current sensing in industrial, automotive, commercial, and communications systems. The device package allows for easy implementation by the customer. Typical applications include motor control, load detection and management, switched-mode power supplies, and overcurrent fault protection. The device consists of a precise, low-offset, linear Hall sensor circuit with a copper conduction path located near the surface of the die. Applied current flowing through this copper conduction path generates a magnetic field which is sensed by the integrated Hall IC and converted into a proportional voltage. Device accuracy is optimized through the close proximity of the magnetic signal to the Hall transducer. A precise, proportional voltage is provided by the low-offset, chopper-stabilized BiCMOS Hall IC, which is programmed for accuracy after packaging. Package: 8 Lead SOIC (suffix LC) The output of the device has a positive slope (>VIOUT(Q)) when an increasing current flows through the primary copper conduction path (from pins 1 and 2, to pins 3 and 4), which is the path used for current sensing. The internal resistance of this conductive path is 1.2 mΩ typical, providing low power Continued on the next page… Approximate Scale 1:1 Typical Application 1 2 IP IP+ VCC IP+ VIOUT ACS713 3 4 IP– FILTER IP– GND +5 V 8 7 VOUT CBYP 0.1 µF 6 5 CF Application 1. The ACS713 outputs an analog signal, VOUT . that varies linearly with the unidirectional DC primary sensed current, IP , within the range specified. CF is recommended for noise management, with values that depend on the application. ACS713-DS Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor ACS713 Description (continued) loss. The thickness of the copper conductor allows survival of the device at up to 5× overcurrent conditions. The terminals of the conductive path are electrically isolated from the sensor leads (pins 5 through 8). This allows the ACS713 current sensor to be used in applications requiring electrical isolation without the use of opto-isolators or other costly isolation techniques. The ACS713 is provided in a small, surface mount SOIC8 package. The leadframe is plated with 100% matte tin, which is compatible with standard lead (Pb) free printed circuit board assembly processes. Internally, the device is Pb-free, except for flip-chip high-temperature Pb‑based solder balls, currently exempt from RoHS. The device is fully calibrated prior to shipment from the factory. Selection Guide Part Number Packing* TOP (°C) Optimized Range, IP (A) Sensitivity, Sens (Typ) (mV/A) ACS713ELCTR-20A-T Tape and reel, 3000 pieces/reel –40 to 85 0 to 20 185 ACS713ELCTR-30A-T Tape and reel, 3000 pieces/reel –40 to 85 0 to 30 133 *Contact Allegro for additional packing options. Absolute Maximum Ratings Characteristic Symbol Notes Rating Units Supply Voltage VCC 8 V Reverse Supply Voltage VRCC –0.1 V Output Voltage VIOUT 8 V Reverse Output Voltage VRIOUT –0.1 V Output Current Source IOUT(Source) 3 mA IOUT(Sink) 10 mA 100 total pulses, 250 ms duration each, applied at a rate of 1 pulse every 100 seconds. 60 A Junction Temperature, TJ < TJ(max) 100 A Output Current Sink Overcurrent Transient Tolerance Maximum Transient Sensed Current Nominal Operating Ambient Temperature Maximum Junction Storage Temperature TÜV America Certificate Number: U8V 06 05 54214 010 IP IR(max) –40 to 85 ºC TJ(max) TA Range E 165 ºC Tstg –65 to 170 ºC Parameter Specification Fire and Electric Shock CAN/CSA-C22.2 No. 60950-1-03 UL 60950-1:2003 EN 60950-1:2001 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor ACS713 Functional Block Diagram +5 V VCC (Pin 8) Hall Current Drive IP+ (Pin 1) Sense Temperature Coefficient Trim Dynamic Offset Cancellation IP+ (Pin 2) IP– (Pin 3) Signal Recovery VIOUT (Pin 7) Sense Trim IP– (Pin 4) 0 Ampere Offset Adjust GND (Pin 5) FILTER (Pin 6) Pin-out Diagram IP+ 1 8 VCC IP+ 2 7 VIOUT IP– 3 6 FILTER IP– 4 5 GND Terminal List Table Number Name Description 1 and 2 IP+ Input terminals for current being sensed; fused internally 3 and 4 IP– Output terminals for current being sensed; fused internally 5 GND 6 FILTER Signal ground terminal Terminal for external capacitor that sets bandwidth 7 VIOUT Analog output signal 8 VCC Device power supply terminal Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor ACS713 COMMON OPERATING CHARACTERISTICS1 over full range of TOP, and VCC = 5 V, unless otherwise specified Characteristic Symbol Test Conditions Min. Typ. Max. Units ELECTRICAL CHARACTERISTICS Supply Voltage VCC 4.5 5.0 5.5 V Supply Current ICC VCC = 5.0 V, output open 6 8 11 mA Supply Zener Clamp Voltage VZ ICC = 11 mA, TA = 25°C 6 8.3 – V Output Resistance RIOUT IIOUT = 1.2 mA, TA=25°C – 1 2 Ω Output Capacitance Load CLOAD VIOUT to GND – – 10 nF Output Resistive Load RLOAD VIOUT to GND 4.7 – – kΩ Primary Conductor Resistance RPRIMARY TA = 25°C RMS Isolation Voltage VISORMS Pins 1-4 and 5-8; 60 Hz, 1 minute, TA=25°C DC Isolation Voltage VISODC tPROP Propagation Time Response Time – 1.2 – mΩ 2100 – – V Pins 1-4 and 5-8; 1 minute, TA=25°C – 5000 – V IP = IP(max), TA = 25°C, COUT = 10 nF – 3 – μs tRESPONSE IP = IP(max), TA = 25°C, COUT = 10 nF μs – 7 – Rise Time tr IP = IP(max), TA = 25°C, COUT = 10 nF – 5 – μs Frequency Bandwidth f –3 dB, TA = 25°C; IP is 10 A peak-to-peak 50 – – kHz Nonlinearity ELIN Over full range of IP , IP applied for 5 ms – ±1 ±1.5 % Symmetry ESYM Over full range of IP , IP applied for 5 ms 98 100 102 % – V – mV Zero Current Output Voltage VIOUT(Q) Unidirectional; IP = 0 A, TA = 25°C – VCC × 0.1 Magnetic Offset Error VERROM IP = 0 A, after excursion of 20 A – 0 Clamping Voltage Power-On Time Magnetic VCH Typ. –110 VCC × Typ. +110 0.9375 mV VCL Typ. –110 VCC × Typ. +110 0.0625 mV tPO Output reaches 90% of steady-state level, no capacitor on FILTER pin; TJ = 25; 20 A present on leadframe Coupling2 Internal Filter Resistance3 – – RF(INT) 35 – µs 12 – G/A 1.7 kΩ 1Device may be operated at higher primary current levels, IP, and ambient, TA , and internal leadframe temperatures, TOP , provided that the Maximum Junction Temperature, TJ(max), is not exceeded. 21G = 0.1 mT. 3R F(INT) forms an RC circuit via the FILTER pin. COMMON THERMAL CHARACTERISTICS1 Operating Internal Leadframe Temperature Junction-to-Lead Thermal Resistance2 Junction-to-Ambient Thermal Resistance2,3 TOP E range Min. Typ. Max. –40 – 85 Units °C Value Units RθJL Mounted on the Allegro ASEK 713 evaluation board 5 °C/W RθJA Mounted on the Allegro 85-0322 evaluation board, includes the power consumed by the board 23 °C/W 1Additional thermal information is available on the Allegro website. evaluation board has 1500 mm2 of 2 oz. copper on each side, connected to pins 1 and 2, and to pins 3 and 4, with thermal vias connecting the layers. Performance values include the power consumed by the PCB. Further details on the board are available from the Frequently Asked Questions document on our website. Further information about board design and thermal performance also can be found in the Applications Information section of this datasheet. 3R θJA values shown in this table are typical values, measured on the Allegro evaluation board. The actual thermal performance depends on the actual application board design, the airflow in the application, and thermal interactions between the sensor and surrounding components through the PCB and the ambient air. To improve thermal performance, see our applications material on the Allegro website. 2The Allegro Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com ACS713 Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor x20A PERFORMANCE CHARACTERISTICS TOP = –40°C to 85°C1; VCC = 5 V, unless otherwise specified Characteristic Optimized Accuracy Range Sensitivity2 Noise Symbol SensTA SensTOP VNOISE(PP) Electrical Offset Voltage Total Output Error3 Test Conditions IP VOE(TOP) ETOT Over full range of IP , IP applied for 5ms; TA = 25°C Over full range of IP , IP applied for 5 ms Min. Typ. Max. 0 – 20 Units A – 185 – mV/A 179.5 – 190.5 mV/A Peak-to-peak, TA= 25°C, 20 kHz external filter, 185 mV/A programmed Sensitivity, CF = 4.7 nF, COUT = 10 nF, 20 kHz bandwidth – 50 – mV Peak-to-peak, TA = 25°C, 2 kHz external filter, 185 mV/A programmed Sensitivity, CF = 47 nF, COUT = 10 nF, 2 kHz bandwidth – 17 – mV Peak-to-peak, TA = 25°C, 185 mV/A programmed Sensitivity, CF = 1 nF, COUT = 10 nF, 50 kHz bandwidth – 80 – mV –40 – 40 mV – ±1.5 – % IP = 0 A IP = 20 A , IP applied for 5 ms; TA = 25°C 1Device may be operated at higher primary current levels, IP, and ambient temperatures, TOP, provided that the Maximum Junction Temperature, TJ(max), is not exceeded. 2At –40°C Sensitivity may shift as much 9% outside of the datasheet limits. 3Percentage of I , with I = 20 A. Output filtered. P P x30A PERFORMANCE CHARACTERISTICS TOP = –40°C to 85°C1; VCC = 5 V, unless otherwise specified Characteristic Optimized Accuracy Range Sensitivity2 Noise Electrical Offset Voltage Total Output Error3 Symbol Test Conditions IP SensTA SensTOP VNOISE(PP) VOE(TOP) ETOT Over full range of IP , IP applied for 5ms; TA = 25°C Over full range of IP , IP applied for 5 ms Min. Typ. Max. 0 – 30 Units A – 133 – mV/A 129 – 137 mV/A Peak-to-peak, TA= 25°C, 20 kHz external filter, 133 mV/A programmed Sensitivity, CF = 4.7 nF, COUT = 10 nF, 20 kHz bandwidth – 33 – mV Peak-to-peak, TA = 25°C, 2 kHz external filter, 133 mV/A programmed Sensitivity, CF = 47 nF, COUT = 10 nF, 2 kHz bandwidth – 10 – mV Peak-to-peak, TA = 25°C, 133 mV/A programmed Sensitivity, CF = 1 nF, COUT = 10 nF, 50 kHz bandwidth – 52 – mV –30 – 30 mV – ±1.5 – % IP = 0 A IP = 30 A , IP applied for 5 ms; TA = 25°C 1Device may be operated at higher primary current levels, IP, and ambient temperatures, TOP, provided that the Maximum Junction Temperature, TJ(max), is not exceeded. 2At –40°C Sensitivity may shift as much 9% outside of the datasheet limits. 3Percentage of I , with I = 30 A. Output filtered. P P Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com ACS713 Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor Definitions of Accuracy Characteristics Sensitivity (Sens). The change in sensor output in response to a 1 A change through the primary conductor. The sensitivity is the product of the magnetic circuit sensitivity (G / A) and the linear IC amplifier gain (mV/G). The linear IC amplifier gain is programmed at the factory to optimize the sensitivity (mV/A) for the full-scale current of the device. Noise (VNOISE). The product of the linear IC amplifier gain (mV/G) and the noise floor for the Allegro Hall effect linear IC (≈1 G). The noise floor is derived from the thermal and shot noise observed in Hall elements. Dividing the noise (mV) by the sensitivity (mV/A) provides the smallest current that the device is able to resolve. Linearity (ELIN). The degree to which the voltage output from the sensor varies in direct proportion to the primary current through its full-scale amplitude. Nonlinearity in the output can be attributed to the saturation of the flux concentrator approaching the full-scale current. The following equation is used to derive the linearity: { [ 100 1– (VIOUT_full-scale amperes –VIOUT(Q) ) 2 (VIOUT_half-scale amperes – VIOUT(Q)) [{ where VIOUT_full-scale amperes = the output voltage (V) when the sensed current approximates full-scale ±IP . Quiescent output voltage (VIOUT(Q)). The output of the sensor when the primary current is zero. For a unipolar supply voltage, it nominally remains at 0.1 × VCC. Thus, VCC = 5 V translates into VIOUT(Q) = 0.5 V. Variation in VIOUT(Q) can be attributed to the resolution of the Allegro linear IC quiescent voltage trim and thermal drift. Electrical offset voltage (VOE). The deviation of the device output from its ideal quiescent value of 0.1 × VCC due to nonmagnetic causes. To convert this voltage to amperes, divide by the device sensitivity, Sens. Accuracy (ETOT). The accuracy represents the maximum deviation of the actual output from its ideal value. This is also known as the total ouput error. The accuracy is illustrated graphically in the output voltage versus current chart on the following page. Accuracy is divided into four areas: • 0 A at 25°C. Accuracy of sensing zero current flow at 25°C, without the effects of temperature. • 0 A over Δ temperature. Accuracy of sensing zero current flow including temperature effects. • Full-scale current at 25°C. Accuracy of sensing the full-scale current at 25°C, without the effects of temperature. • Full-scale current over Δ temperature. Accuracy of sensing fullscale current flow including temperature effects. Ratiometry. The ratiometric feature means that its 0 A output, VIOUT(Q), (nominally equal to 0.1 × VCC) and sensitivity, Sens, are proportional to its supply voltage, VCC . The following formula is used to derive the ratiometric change in 0 A output voltage, ΔVIOUT(Q)RAT (%). 100 VIOUT(Q)VCC / VIOUT(Q)5V VCC / 5 V The ratiometric change in sensitivity, ΔSensRAT (%), is defined as: 100 SensVCC / Sens5V VCC / 5 V Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com ACS713 Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor Output Voltage versus Sensed Current Accuracy at 0 A and at Full-Scale Current Increasing VIOUT(V) Accuracy Over $Temp erature Accuracy 25°C Only Average VIOUT Accuracy Over $Temp erature Accuracy 25°C Only 30 A –IP (A) +IP (A) Full Scale 0A Decreasing VIOUT(V) Definitions of Dynamic Response Characteristics Propagation delay (tPROP). The time required for the sensor output to reflect a change in the primary current signal. Propagation delay is attributed to inductive loading within the linear IC package, as well as in the inductive loop formed by the primary conductor geometry. Propagation delay can be considered as a fixed time offset and may be compensated. Response time (tRESPONSE). The time interval between a) when the primary current signal reaches 90% of its final value, and b) when the sensor reaches 90% of its output corresponding to the applied current. I (%) Primary Current 90 Transducer Output 0 Propagation Time, tPROP I (%) Primary Current 90 Transducer Output 0 Response Time, tRESPONSE Rise time (tr). The time interval between a) when the sensor reaches 10% of its full scale value, and b) when it reaches 90% of its full scale value. The rise time to a step response is used to derive the bandwidth of the current sensor, in which ƒ(–3 dB) = 0.35 / tr. Both tr and tRESPONSE are detrimentally affected by eddy current losses observed in the conductive IC ground plane. t I (%) t Primary Current 90 Transducer Output 10 0 Rise Time, tr t Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor ACS713 Chopper Stabilization Technique Sample and Hold This technique is made possible through the use of a BiCMOS Chopper Stabilization is an innovative circuit technique that is used to minimize the offset voltage of a Hall element and an asso- process that allows the use of low-offset and low-noise amplifiers in combination with high-density logic integration and sample ciated on-chip amplifier. Allegro patented a Chopper Stabilizaand hold circuits. tion technique that nearly eliminates Hall IC output drift induced by temperature or package stress effects. This offset reduction Regulator technique is based on a signal modulation-demodulation process. +5 V VS1 from Modulation is used to separate the undesired dc offset signal Clock/Logic the magnetically induced signal in the frequency domain. Then, CBYP Low-Pass using a low-pass filter, the modulated dc offset is suppressed Hall Element 0.1 µF Filter 8 1 VCC while the magnetically induced signal passes through the filter. IP+ U1 7 VOUT + 2 LMC6772 Amp As a result of this chopper stabilization approach, the output IP+ VIOUT – V REF voltage from the Hall IC is desensitized to the effects of temperaACS713 IP1 6 ture and mechanical stress. This technique produces devices3that IP– FILTER CF 4 have an extremely stable Electrical Offset Voltage, are immune to IP– 5 GND thermal stress, and have precise recoverability after temperature Q3 2N7002 cycling. R3 10 kΩ Q1 FDS6675a R1 100 kΩ Typical Applications VS2 +5 V CBYP 0.1 µF 1 2 IP IP+ R1 33 kΩ VCC IP+ VIOUT ACS713 3 4 IP– FILTER IP– GND 8 7 1 VOUT IP2 4 3 6 5 CF 2 RPU 100 kΩ R2 100 kΩ – + 5 1 +5 V VCC IP+ IP+ VIOUT IP– FILTER Fault 4 IP– GND 2 U1 LMV7235 6 – 8 5 IP Q4 6 2N7002 IP– FILTER 4R4 10IP– kΩ GND 5 Application 2. 10 A Overcurrent Fault Latch. Fault threshold set by R1 and R2. This circuit latches an overcurrent fault and holds it until the 5 V rail is powered down. 2 IP1 VCC IP+ VIOUT ACS713 3 4 IP– FILTER IP– GND 3 – LM321 5 VOUT 4 2 C1 1000 pF R3 3.3 kΩ CF 0.01 µF +5 V IP+ + Application 3. This configuration increases gain to 610 mV/A (tested using the ACS712ELC-05A). VS1 1 1 RF 1 kΩ ACS713 Q2 FDS6675a R2 100 kΩ R2 100 kΩ 1 VCC IP+ 7 2CF IP+ VIOUT 3 D1 1N914 Application 4. Control circuit for MOSFET ORing. R1 100 kΩ U2 LMC6772 + 7 VOUT LOAD +5 V CBYP CBYP 0.1 µF 0.1 µF 8 VREF ACS713 3 Concept of Chopper Stabilization Technique CBYP 0.1 µF 8 + 7 VOUT VREF 1 U1 LMC6772 – 2 IP2 6 5 +5 V VS2 CF IP+ VCC IP+ VIOUT ACS713 3 4 IP– FILTER IP– GND CBYP 0.1 µF 8 + 7 VOUT VREF – 6 5 CF Q3 2N7002 Q1 FDS6675a U2 LMC6772 Q4 2N7002 Q2 FDS6675a R3 10 kΩ R4 10 kΩ R2 100 kΩ R1 100 kΩ LOAD Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor ACS713 Improving Sensing System Accuracy Using the FILTER Pin In low-frequency sensing applications, it is often advantageous to add a simple RC filter to the output of the sensor. Such a lowpass filter improves the signal-to-noise ratio, and therefore the resolution, of the sensor output signal. However, the addition of an RC filter to the output of a sensor IC can result in undesirable sensor output attenuation — even for dc signals. Signal attenuation, ∆VATT , is a result of the resistive divider effect between the resistance of the external filter, RF (see Application 5), and the input impedance and resistance of the customer interface circuit, RINTFC. The transfer function of this resistive divider is given by: RINTFC RF + RINTFC ∆VATT = VIOUT . Even if RF and RINTFC are designed to match, the two individual resistance values will most likely drift by different amounts over temperature. Therefore, signal attenuation will vary as a function of temperature. Note that, in many cases, the input impedance, RINTFC , of a typical analog-to-digital converter (ADC) can be as low as 10 kΩ. The ACS713 contains an internal resistor, a FILTER pin connection to the printed circuit board, and an internal buffer amplifier. With this circuit architecture, users can implement a simple RC filter via the addition of a capacitor, CF (see Application 6) from the FILTER pin to ground. The buffer amplifier inside of the ACS713 (located after the internal resistor and FILTER pin connection) eliminates the attenuation caused by the resistive divider effect described in the equation for ∆VATT. Therefore, the ACS713 device is ideal for use in high-accuracy applications that cannot afford the signal attenuation associated with the use of an external RC low-pass filter. +5 V Pin 3 Pin 4 IP– IP– VCC Pin 8 Allegro ACS706 Application 5. When a low pass filter is constructed externally to a standard Hall effect device, a resistive divider may exist between the filter resistor, RF, and the resistance of the customer interface circuit, RINTFC. This resistive divider will cause excessive attenuation, as given by the transfer function for ∆VATT. Voltage Regulator To all subcircuits Filter Dynamic Offset Cancellation 0.1 MF Resistive Divider VIOUT Pin 7 Amp Out N.C. Pin 6 Input RF Application Interface Circuit Low Pass Filter Temperature Coefficient Gain Offset CF RINTFC Trim Control GND Pin 5 IP+ IP+ Pin 1 Pin 2 +5 V VCC Pin 8 Allegro ACS713 Hall Current Drive IP+ Pin 1 IP+ Pin 2 IP– Pin 3 IP– Pin 4 Sense Temperature Coefficient Trim Buffer Amplifier and Resistor Dynamic Offset Cancellation Application 6. Using the FILTER pin provided on the ACS713 eliminates the attenuation effects of the resistor divider between RF and RINTFC, shown in Application 5. Signal Recovery VIOUT Pin 7 Input Application Interface Circuit Sense Trim 0 Ampere Offset Adjust RINTFC GND Pin 5 FILTER Pin 6 CF Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Fully Integrated, Hall Effect-Based Linear Current Sensor with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor ACS713 Package LC, 8-pin SOIC 6.20 .244 5.80 .228 0.25 [.010] M B M 8 Preliminary dimensions, for reference only Dimensions in millimeters U.S. Customary dimensions (in.) in brackets, for reference only (reference JEDEC MS-012 AA) Dimensions exclusive of mold flash, gate burrs, and dambar protrusions Exact case and lead configuration at supplier discretion within limits shown A Terminal #1 mark area 5.00 .197 4.80 .189 8º 0º A B 0.25 .010 0.17 .007 4.00 .157 3.80 .150 1.27 .050 0.40 .016 A 1 2 0.25 .010 8X 8X 0.51 .020 0.31 .012 0.25 .010 0.10 .004 1.27 .050 ACS713T RLCPPP YYWWA ACS 713 T R LC PPP YY WW A 2 Text 1 Text 2 Text 3 Two alternative patterns are used 1 SEATING PLANE GAUGE PLANE 1.75 .069 1.35 .053 0.25 [.010] M C A B Package Branding C SEATING PLANE 0.10 [.004] C 8 7 3 6 4 5 Allegro Current Sensor Device family number Indicator of 100% matte tin leadframe plating Operating ambient temperature range code Package type designator Primary sensed current Date code: Calendar year (last two digits) Date code: Calendar week Date code: Shift code The products described herein are manufactured under one or more of the following U.S. patents: 5,045,920; 5,264,783; 5,442,283; 5,389,889; 5,581,179; 5,517,112; 5,619,137; 5,621,319; 5,650,719; 5,686,894; 5,694,038; 5,729,130; 5,917,320; and other patents pending. Allegro MicroSystems, Inc. reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the performance, reliability, ACS713T RLCPPP L...L YYWW ACS 713 T R LC PPP L...L YY WW Allegro Current Sensor Device family number Indicator of 100% matte tin leadframe plating Operating ambient temperature range code Package type designator Primary sensed current Lot code Date code: Calendar year (last two digits) Date code: Calendar week or manufacturability of its products. Before placing an order, the user is cautioned to verify that the information being relied upon is current. The information included herein is believed to be accurate and reliable. However, Allegro MicroSystems, Inc. assumes no responsibility for its use; nor for any infringement of patents or other rights of third parties which may result from its use. Copyright ©2006, Allegro MicroSystems, Inc. For the latest version of this document, go to our website at: www.allegromicro.com 10 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com