Minmax MIHW2032 Dc/dc converter 3w, reinforced insulation, medical safety Datasheet

®
MIHW2000 SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
FEATURES
►Reinforced Insulation rated for 300VAC Working Voltage
►I/O-isolation Voltage 4000VACrms
►Industrial & Medical Safety Approval
►Ultra-wide Input Voltage Ranges:
9-40VDC, 18-80VDC and 36-160VDC
►Fully regulated Output Voltage
►Low Leakage Current
►Operating Temp. Range –40°C to +85 °C
►Input Filter meets EN 55022, class A
►Short Circuit Protection
►3 Years Product Warranty
PRODUCT OVERVIEW
The MINMAX MIHW2000 series is a range of high performance DC/DC converter modules with a reinforced insulation system .The I/O- isolation voltage is
specified for 4000VACrms.The product comes in a small DIP-24 package. All models features an ultra-wide input voltage range including 36-160VDC for
railroad applications.
Full SMD design with exclusive use of ceramic capacitors guarantees a high reliability with calculated MTBF of >1 Mio. hours.
These high isolation DC/DC converters are the perfect solution solution for many demanding applications in industrial and railroad systems, in medical
instrumentation, everywhere where a certified supplementary or reinforced insulation system is required to comply with specific industrial or medical safety
standards.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MIHW2022
MIHW2023
MIHW2026
MIHW2027
MIHW2032
MIHW2033
MIHW2036
MIHW2037
MIHW2042
MIHW2043
MIHW2046
MIHW2047
24
(9 ~ 40)
48
(18 ~ 80)
110
(36 ~ 160)
VDC
5
12
±12
±15
5
12
±12
±15
5
12
±12
±15
Output Current
Input Current
Reflected
Max. capacitive
Ripple
Load
Max.
Min.
@Max. Load
@No Load
Current
mA
600
250
±125
±100
600
250
±125
±100
600
250
±125
±100
mA
90
37.5
±18.8
±15
90
37.5
±18.8
±15
90
37.5
±18.8
±15
mA(typ.)
160
151
151
151
80
75
75
75
35
33
33
33
mA(typ.)
mA (typ.)
20
15
10
8
5
3
Efficiency
(typ.)
@Max. Load
uF
1000
470
220#
220#
1000
470
220#
220#
1000
470
220#
220#
%
78
83
83
83
78
83
83
83
78
83
83
83
# For each output
Input Specifications
Parameter
Model
24V Input Models
48V Input Models
110V Input Models
24V Input Models
48V Input Models
110V Input Models
24V Input Models
48V Input Models
110V Input Models
Input Surge Voltage (1 sec. max.)
Start-Up Voltage
Under Voltage Shutdown
Reverse Polarity Input Current
Short Circuit Input Power
Internal Power Dissipation
Conducted EMI
E-mail:[email protected]
2011/09/22 REV:4
All Models
Tel:886-6-2923150
Page 1 of 4
Min.
Typ.
Max.
Unit
-0.7
--50
-0.7
--100
-0.7
--180
8
8.5
9
VDC
13
15
17
26
30
34
----8.5
----16
----32
----0.3
A
----2000
mW
----2500
mW
Compliance to EN 55022,class A and FCC part 15,class A
®
MIHW2000 SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
Output Specifications
Parameter
Conditions
Min.
Typ.
Max.
---
±0.5
±1.0
%
Dual Output, Balanced Loads
---
±0.5
±2.0
%
Line Regulation
Vin=Min. to Max.
---
±0.3
±0.5
%
Load Regulation
Io=25% to 100%
---
±0.5
±1.0
%
5V Output Models
---
75
100
mV P-P
Other Output Models
---
100
150
mV P-P
Over Line, Load & Temp.
---
---
180
mV P-P
---
---
15
mV rms
---
150
500
uS
---
±3
±6
%
---
±0.02
±0.05
%/℃
120
150
---
%
Output Voltage Accuracy
Output Voltage Balance
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Transient Recovery Time
25% Load Step Change
Transient Response Deviation
Temperature Coefficient
Over Load Protection
Foldback
Short Circuit Protection
Unit
Continuous
Isolation, Safety Standards
Parameter
I/O Isolation Voltage (rated)
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
4000
---
---
VACrms
Flash tested for 1 Second
6000
---
---
VPK
240VAC, 60Hz
---
---
2
uA
I/O Isolation Resistance
500 VDC
10
---
---
GΩ
I/O Isolation Capacitance
100KHz, 1V
13
pF
I/O Isolation Test Voltage
Leakage Current
Safety Standards
Approvals
--7
cUL/UL60950-1, CSA C22.2 No. 60950-1-03
UL60601-1,CSA C22.2 No.601-1
IEC/EN 60950-1, IEC/EN 60601-1
IEC60950-1 CB report, cUL/UL 60950-1 certificate
UL60601-1 UL certificate
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
---
150
---
KHz
1,000,000
---
---
Hours
Switching Frequency
MTBF(calculated)
MIL-HDBK-217F@25℃, Ground Benign
Input Fuse
24V Input Models
48V Input Models
110V Input Models
1000mA Slow-Blow Type
500mA Slow-Blow Type
300mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Conditions
Min.
Max.
Unit
Ambient
-40
+85
℃
℃
Case Temperature
---
+95
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Cooling
Free-Air convection
Lead Temperature (1.5mm from case for 10Sec.)
---
E-mail:[email protected]
2011/09/22 REV:4
Tel:886-6-2923150
Page 2 of 4
®
MIHW2000 SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
Power Derating Curve
100
Natural
convection
80
100LFM
200LFM
60
400LFM
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature ]
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3
Ripple & Noise measurement bandwidth is 0-20 MHz.
4
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
5
All DC/DC converters should be externally fused at the front end for protection.
6
Other input and output voltage may be available, please contact factory.
7
Specifications subject to change without notice.
modules; however, they may not meet all specifications listed.
Package Specifications
3.9 10.5 [0.41]
[0.15]
Pin Connections
0.2 [0.008]
Mechanical Dimensions
0.60 [0.024]
20.32 [0.80]
2.54
[0.10]
31.8 [1.25]
+Vin
11
No Pin
Common
12
-Vout
No Pin
13
+Vout
-Vout
15
No Pin
+Vout
23
-Vin
-Vin
24
-Vin
-Vin
5.08
[0.20]
2.0
[0.08]
►All
dimensions in mm (inches)
►Tolerance: X.X±0.25
Physical Characteristics
Case Size
:
Case Material
:
31.8x20.3x10.5mm (1.25x0.8x0.41 Inches)
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Weight
:
16.2g
2011/09/22 REV:4
Tel:886-6-2923150
Page 3 of 4
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
►Pin
E-mail:[email protected]
Dual Output
13
2.54
[0.10]
15
23
+Vin
12
Bottom View
24
Single Output
1
20.3 [0.80]
11
15.22 [0.60]
1
Pin
diameter  0.6 ±0.05 (0.024±0.002)
®
MIHW2000 SERIES
DC/DC CONVERTER 3W, Reinforced Insulation, Medical Safety
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load
between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
+Out
Dual Output
DC / DC
Converter
Com.
-Vin
Copper Strip
Copper Strip
+Vin
Scope
Cout
Cout
-Out
Resistive
Load
Copper Strip
Scope
Copper Strip
Design & Feature Considerations
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor on the input to insure startup. By using a
good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 kHz) capacitor of a 4.7uF for the 24V input devices, a 2.2uF for the 48V devices and a 1uF for the
110V devices, capacitor mounted close to the power module helps ensure stability of the unit.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3uF capacitors at the output.
+
+Vin
-
+Out
Single Output
DC / DC
Converter
DC Power
Source
-Vin
+
Cout
+Vin
DC Power
Source
Load
-Out
-
+Out
Dual Output
DC / DC
Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MIHW2000 series has limitation of maximum connected capacitance on the output. The power module may operate in current limiting mode during start-up,
affecting the ramp-up and the startup time. Connect capacitors at the point of load for best performance. The maximum capacitance can be found in the data
sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2011/09/22 REV:4
Page 4 of 4
Similar pages