SHIELD MN-FKG4-25XC5 Pvc, 105â°c and 90â°c Datasheet

CABLES - CAVI
MN-FK
MN-GE
MN-GK
PVC, 105°C and 90°C
PVC, 105°C e 90°C
Description. Conductor insulation: special PVC. Outer sheath: special PVC.
Application. Suitable for connections in industrial automation where for long periods a heat and
cold resistant and soft cable is required. Moderate resistance to common oils. Flame resistance
grade: self-extinguishing. The cables with class 6 conductors have a good behaviour in mobile
laying. Limited resistance to abrasion.
Max working voltage: 300 V. Test voltage: 1500V up to 0,25 mm2, 2000 V over.
Descrizione. Isolante conduttori: PVC speciale. Guaina esterna: PVC speciale.
Impiego. Adatto per collegamenti in automazione industriale dove è richiesto un cavo morbido,
resistente al calore e al freddo per lunghi periodi. Moderata resistenza agli oli comuni. Grado
di resistenza alla fiamma: autoestinguente. I cavi con rame classe 6 sono anche progettati per
l’uso in posa mobile. Limitata resistenza all’abrasione.
Tensione massima di lavoro: 300 V. Tensione di prova: 1500 V fino a 0,25 mm2, 2000 V
oltre.
Note to table:
(a) example: 3 = three wires; 2+1 = two wires + yellow/green earth.
(b) colours: A = brown, blue, black, white, grey; yellow/green earth if present.
C = according to IEC 60304 (former DIN 47100), see section “General Information”.
N = black with white numbers; yellow/green earth if present.
(c) DIN / VDE cable construction classification.
Formation
Formazione
Descriptive code
Codice descrittivo
Short
code
Codice
breve
0,75
0,50
0,34
0,25
0,14
0,50
0,34
0,25
n x mm2 (a)
3x0,25
4x0,25
10x0,25
18x0,25
25x0,25
3x0,34
4x0,34
12x0,34
18x0,34
25x0,34
3x0,50
4x0,50
12x0,50
18x0,50
25x0,50
2x0,14
3x0,14
4x0,14
2x0,25
3x0,25
4x0,25
5x0,25
6x0,25
7x0,25
8x0,25
2x0,34
3x0,34
4x0,34
2x0,50
(2+1)x0,50
3x0,50
(3+1)x0,50
4x0,50
(4+1)x0,50
2x0,75
(2+1)x0,75
3x0,75
(3+1)x0,75
4x0,75
(4+1)x0,75
5x0,75
6x0,75
(6+1)x0,75
7x0,75
8x0,75
(9+1)x0,75
10x0,75
(11+1)x0,75
12x0,75
33 MN-F 1
MN-FKG
MN-FKG2-03XC5
MN-FKG2-04XC5
MN-FKG2-10XC5
MN-FKG2-18XC5
MN-FKG2-25XC5
MN-FKG3-03XC5
MN-FKG3-04XC5
MN-FKG3-12XC5
MN-FKG3-18XC5
MN-FKG3-25XC5
MN-FKG4-03XC5
MN-FKG4-04XC5
MN-FKG4-12XC5
MN-FKG4-18XC5
MN-FKG4-25XC5
MN-GE9
MN-GE91-02XA5
MN-GE91-03XA5
MN-GE91-04XA5
MN-GE92-02XA5
MN-GE92-03XA5
MN-GE92-04XA5
MN-GE92-05XA5
MN-GE92-06XC5
MN-GE92-07XC5
MN-GE92-08XC5
MN-GE93-02XA5
MN-GE93-03XA5
MN-GE93-04XA5
MN-GK9
MN-GK94-02XA5
MN-GK94-03GA5
MN-GK94-03XA5
MN-GK94-04GA5
MN-GK94-04XA5
MN-GK94-05GA5
MN-GK95-02XA5
MN-GK95-03GA5
MN-GK95-03XA5
MN-GK95-04GA5
MN-GK95-04XA5
MN-GK95-05GA5
MN-GK95-05XA5
MN-GK95-06XC5
MN-GK95-07GN5
MN-GK95-07XC5
MN-GK95-08XC5
MN-GK95-10GN5
MN-GK95-10XC5
MN-GK95-12GN5
MN-GK95-12XC5
216
220
305
306
323
329
330
41C
42C
43C
107
108
104
209
205
206
201
301
302
412
414
411
504
510
550
511
Note alla tabella:
(a) esempio: 3 = tre conduttori; 2+1 = due conduttori + terra giallo/verde.
(b) colori: A = marrone, blu, nero, bianco, grigio; terra giallo/verde se presente.
C = secondo IEC 60304 (ex DIN 47100), vedere sezione “Informazioni Generali”.
N = nero con numeri bianchi; terra giallo/verde se presente.
(c) classificazione DIN / VDE della costruzione del cavo.
Refer. or style
Rifer. o style
Sheath colour
Colore guaina
Wires
colour
Colore
cond.
Copper
class
Classe
rame
Static
application
Applicazione
statica
Dynamic
application
Applicazione
dinamica
(c)
RAL
(b)
IEC 60228
°C
°C
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
LiYYW
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
gy 7001
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
-25...+105
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
LifYY
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
A
A
A
A
A
A
A
C
C
C
A
A
A
6
6
6
6
6
6
6
6
6
6
6
6
6
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
A
A
A
A
A
A
A
A
A
A
A
A
A
C
N
C
C
N
C
N
C
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
www.shield.net
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
-15...+ 90
Note Nota
CABLES - CAVI
Formation
Formazione
Descriptive code
Codice descrittivo
1,00
0,75
n x mm2 (a)
14x0,75
(15+1)x0,75
16x0,75
(17+1)x0,75
18x0,75
20x0,75
2x1,00
(2+1)x1,00
3x1,00
(3+1)x1,00
4x1,00
(4+1)x1,00
5x1,00
6x1,00
(6+1)x1,00
7x1,00
8x1,00
(9+1)x1,00
10x1,00
(11+1)x1,00
12x1,00
14x1,00
(15+1)x1,00
16x1,00
(17+1)x1,00
18x1,00
20x1,00
MN-GK95-14XC5
MN-GK95-16GN5
MN-GK95-16XC5
MN-GK95-18GN5
MN-GK95-18XC5
MN-GK95-20XC5
MN-GK96-02XA5
MN-GK96-03GA5
MN-GK96-03XA5
MN-GK96-04GA5
MN-GK96-04XA5
MN-GK96-05GA5
MN-GK96-05XA5
MN-GK96-06XC5
MN-GK96-07GN5
MN-GK96-07XC5
MN-GK96-08XC5
MN-GK96-10GN5
MN-GK96-10XC5
MN-GK96-12GN5
MN-GK96-12XC5
MN-GK96-14XC5
MN-GK96-16GN5
MN-GK96-16XC5
MN-GK96-18GN5
MN-GK96-18XC5
MN-GK96-20XC5
Short
code
Codice
breve
Refer. or style
Rifer. o style
Sheath colour
Colore guaina
Wires
colour
Colore
cond.
Copper
class
Classe
rame
Static
application
Applicazione
statica
Dynamic
application
Applicazione
dinamica
(c)
RAL
(b)
IEC 60228
°C
°C
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
LiYY
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
bk 9005
www.shield.net
C
N
C
N
C
C
A
A
A
A
A
A
A
C
N
C
C
N
C
N
C
C
N
C
N
C
C
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Note Nota
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
-25...+ 90
33 MN-F 2
Similar pages