EFM10 1 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies series Universal 90-264VAC Input High Efficiency Improved EMI Performance 3000V Isolation Single, Dual & Triple Outputs UL60950-1, EN60950-1 1.66”W x 2.46”L x 0.91”H Model Number Output Voltage Output Amps(max) SINGLE OUTPUT EFM-0100 EFM-0101 EFM-0122 EFM-0102 EFM-0103 EFM-0105 3.3 Volts(DC) 5 Volts(DC) 9 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 2.5Amps 2Amps 1.1Amps 0.85Amps 0.67Amps 0.42Amps DUAL OUTPUT EFM-0106 EFM-0107 EFM-0108 ±12 Volts(DC) ±15 Volts(DC) 5 / 12Volts(DC) ±0.42Amps ±0.34Amps 1.3 / 0.6Amps TRIPLE OUTPUT EFM-0109 EFM-0111 5/ ±12 Volts(DC) 5/ ±15 Volts(DC) 1.8 / ±0.13Amps 1.8/ ±0.13Amps WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EFM10 1 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: 90-264 VAC 47-63 Hz 20Amps @115 Volts(DC) 40Amps @230 Volts(DC) Efficiency Switching Frequency Safety EMC series Single/Dual 75% typ Triple 70% 100Khz, (fixed, typical) UL60950-1, EN60950-1 EN55022 PHYSICAL SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage and Current (Note 5) See Selection Chart Load Regulation (20%-FL)(Note 6)Singles: ± 3%, Duals: ± 3% (EFM-0108: 0.5/3%) Triple: 0.2 / ±0.3% Line Regulation, typ (Note 7) Singles ± 0.1~1% Duals ± 0.3~1% (except EFM-0108: 0.5/ 0.5%) Triple: 0.3 / ±0.1% Cross Regulation (Note 10) Duals 2% (EFM-0108: 0.5/3%) Triple: NA/ ±0.1% Preset Accuracy (Note 8) Single/Duals 1% (except EFM-0108: 2 / 5%) Triple: 1 / ±5% DC Voltage Adjust (typ) ± 6% of FS (Primary) Temperature Coefficient ±0.03%/°C Ripple/Noise, typ (Note 1, 9) Single/Dual: 100mVpk-pk (except EFM-0108: 50/50mVpk-pk) Triple: 50 / ±75mVpk-pk Over Voltage Protection Clamp Over Temp. Protection Latching, recov after cooling and power restored Short Circuit Protection (Note 2) Continuous, self-recovering Hold Up Time 30 mS, typ DC Output Power 10 Watts, max GENERAL SPECIFICATIONS Isolation (Note 3) 3KVAC Input-Output 2500VAC Inpout-Ground 1000VAC Output-Ground All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Size Construction Weight 1.66” x 2.46” x 0.91” Open Frame 1.6oz (44g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature (Note 4) Storage Temperature Relative Humidity MTBF -0 to +40°C (See Derate) -25 to +71°C * 0 to + 95%, non-cond * (Mil Std 217, 25°C) 575,000 Hrs notes 1. Ripple and Noise depend upon output voltage as specified per particular model. 2. Short Curcuit Protection is self-recovering when overcurrent condition is removed. 3.Isolation for up to 1 minute duration. 4. Specified for free-air convection cooling. 5. Minimum load is NOT required for proper operation. However, auxiliary outputs should be reduced as a function of primary output minimum load or load regulation will be higher. 6. Load regulation measured from 20% to full load. 7. Line regulation measured from 90VAC to 264VAC. 8. Preset accuracy measured at nominal load, 120VAC input. 9. O/P noise measured directly at pins/terminals at nom. load, 0.1uF bypass, pk-pk @20MHz bandwidth. 10.Cross Reg-Duals: Measured at nom. load with the other output varied between 60% and 100% inom. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EFM10 1 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies series OUTPUT DERATING CURVE °C MECHANICAL DIMENSIONS - Single + dual outputs Pin# Single Dual Dual(0108) 1 2 3 4 5 ACL ACN +Vout NC -Vout ACL ACN +Vout Com -Vout ACL ACN +12V +5V Com Dimensions are in inches WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 0 W U l t r a m i n i a t ure Open Frame Switching Power Supplies EFM10 series MECHANICAL DIMENSIONS - TRIPLE outputs WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458