Series AM30E-Z 30Watt | DC-DC Converter FEATURES: Wide 2:1 Input Range 1600 VDC I/O Isolation Adjustable Output Voltage Soft Start Over Current & Over Voltage Protection Over Temperature Protection Efficiency up to 92% Temperature Range -40ºC to +75ºC Remote On/Off Function Continuous Short Circuit Protection No Minimum Load Required Models Single output Model AM30E-1203SZ AM30E-1205SZ AM30E-1205.1SZ AM30E-1212SZ AM30E-1215SZ AM30E-2403SZ AM30E-2405SZ AM30E-2405.1SZ AM30E-2412SZ AM30E-2415SZ AM30E-4803SZ AM30E-4805SZ AM30E-4805.1SZ AM30E-4812SZ AM30E-4815SZ Input Voltage (V) Output Voltage (V) Output Current max (A) Maximum Capacitive Load (uF) Efficiency (%) 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 3.3 5 5.1 12 15 3.3 5 5.1 12 15 3.3 5 5.1 12 15 8 6 6 2.5 2 8 6 6 2.5 2 8 6 6 2.5 2 20000 14000 14000 2000 2000 20000 14000 14000 2000 2000 20000 14000 14000 2000 2000 89 91 92 91 92 91 92 92 92 92 90 91 91 91 91 Input Voltage (V) Output Voltage (V) Output Current max (mA) Maximum Capacitive Load (uF) Efficiency (%) Models Dual output Model AM30E-1205DZ AM30E-1212DZ AM30E-1215DZ AM30E-2405DZ AM30E-2412DZ AM30E-2415DZ AM30E-4805DZ AM30E-4812DZ AM30E-4815DZ 9-18 9-18 9-18 18-36 18-36 18-36 36-75 36-75 36-75 ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 ±3 ±1.25 ±1 ±3 ±1.25 ±1 ±3 ±1.25 ±1 ±3000 ±1300 ±1300 ±3000 ±1300 ±1300 ±3000 ±1300 ±1300 89 90 91 90 91 91 90 90 90 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal 12 24 48 Filter Start up time Absolute Maximum Rating Peak Input Voltage time On/Off control www.aimtec.com F 051e R12.D 12 24 48 Typical 9-18 18-36 36-75 π (Pi) Network 30 -0.7 ~ 25 -0.7 ~ 50 -0.7 ~ 100 Maximum Units VDC ms VDC 100 ms ON: 3 ~12VDC or open circuit ; OFF - 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3 Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30E-Z 30Watt | DC-DC Converter Input Specifications (continued) Parameters Under voltage lockout Nominal Typical Maximum 12V ON/OFF 24V ON/OFF 48V ON/OFF Units 8.6 / 7.9 17.8 / 16 33.5 / 30.5 VDC Isolation Specifications Parameters Tested I/O voltage Case/Input tested voltage Resistance Capacitance Conditions Typical 3 sec 3 sec Rated Units 1600 VDC VDC MOhm pF 1600 1000 1500 Output Specifications Parameters Conditions Typical Voltage accuracy Cross Regulation (Dual Output Models) Over voltage protection Over current protection Short Circuit protection Short circuit restart Thermal shutdown Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise Voltage adjustment range (single) Minimum Load Current 25% load on one output 100% load on second load Maximum % ±5 % Zener diode clamp 150 Continuous Auto-Recovery 115 ±0.5 ±0.5 ±1 ±0.02 100 ±10 0 On Case HL-LL 0 – 100% load 0 – 100% load 20MHz Bandwidth Units ±1 % ºC % % % %/oC mV p-p % % of Max General Specifications Parameters Conditions Typical Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation 100% load Derating above 50 330 www.aimtec.com F 051e R12.D Maximum -40 to +75 -40 to +125 105 2 Free Air Convection 95 Nickel coated Copper 31 2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm >435,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC)hours 1.5mm from case for 10 sec 260 250 ±3 Tel: +1 514 620 2722 2 of 4 Units KHz o C o C o C %/ oC % RH g o C mS % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30E-Z 30Watt | DC-DC Converter Safety Specifications Parameters Agency Approvals CE EN55022 Class A IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria A (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria A (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A NOTE: also designed to meet IEC/EN 60950-1 Standards Pin Out Specifications Pin 1 2 3 4 5 6 Single + V Input - V Input On/Off Control + V Output -V Output Trim Dual + V Input - V Input On/Off Control + V Output Common - V Output Dimensions 4 5 Bottom View 3 Diameter 1.00 (0.04) www.aimtec.com F 051e R12.D 5.08 (0.20) 10.16 (0.40) 2.54 (0.10) 6 10.16 (0.40) 25.40 (1.00) 1 2 10.16 (0.40) 2.54 (0.10) 5.08 (0.20) 5.08 (0.20) 50.80 (2.00) 10.16 (0.40) Single and Dual Output Models 2.54 (0.10) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30E-Z 30Watt | DC-DC Converter Trimming Derating Free Air Convection 50 ºC Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 20 - 40 0 20 40 60 75 80 100 Ambient Temperature º C Control ON/OFF Positive logic turns on the module during high logic and off during low logic. Module can be controlled by an external switch between the On/Off CTRL terminal and –Vinput terminal. The switch can be either open collector or open drain Recommended Circuits C1 100uF, 100V L 12uH C2 1206, 470pF, 2KV Conducted/Radiated Emissions Dual Output Conducted/Radiated Emissions Single Output L C1 L +V output +V input +V output +V input C1 DC/DC Converter DC/DC Converter Load Load -V output -V input -V input -V output Load Common C2 C2 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.D Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only