HBS SERIES - 100 WATT DESCRIPTION HBS DC/DC converters provide up to 100 Watts of output power in an industry standard half-brick package and footprint. These units feature excellent efficiency, Class A conducted noise specs, and fixed switching frequency. The HBS series feature open-frame packaging, along with planar magnetics to provide maximum useable power with minimal thermal constraints. The HBS series is well suited for telecom, networking, and industrial applications, and is fully compatible with production board washing processes. FEATURES • Industry Standard HalfBrick • Open-Frame Packaging • 100°C Baseplate Operation • • • • Water Washable “True-Trim” Option 1500V Isolation Positive Or Negative Logic Efficiency vs. Load (24V Input) 90 88 EFFICIENCY % 86 84 82 HBS100YJ-A 80 EFF. (18V) 78 EFF. (24V) 76 TECHNICAL SPECIFICATIONS EFF. (36V) 74 72 Input 10 Voltage range 24 VDC nominal 48 VDC nominal Reflected ripple Input Reverse Voltage Protection 20 30 40 50 60 70 80 90 100 80 90 100 LOAD % 18 - 36 VDC 34 - 75 VDC 25 mA Shunt Diode Efficiency vs. Load (48V Input) 90 85 Output Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated ±1% ±0.2% Vout Load Regulation Iout Min. - Iout Max., Vin Nom. ±0.2% Vout Remote Sense Headroom Minimum Output Current 80 75 70 0.5 VDC 10%, Iout Rated Dynamic Regulation, Loadstep 65 25% Iout Pk Deviation 60 4% Vout Settling Time Voltage Trim Range Short Circuit / Overcurrent Protection Current Limit Threshold Range, % of Iout Rated OVP Trip Range HBS100ZG-A 10 20 30 40 500 ms ±10% Hiccup 110 - 140% 60 70 LOAD % General 115 - 140% Vout Nom. OVP 50 Turn-On Time Remote Shutdown Remote Shutdown Reference Hiccup Switching Frequency Isolation Input - Output Input - Case Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Thermal Shutdown Range Vibration, 3 Axes, 5 Min Each MTBF† (Bellcore TR-NWT-000332) Notes † MTBF predictions may vary slightly from model to model. Specifications typically at 25°C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with commercial wave-soldering equipment. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. Safety Weight (approx.) REV. 12/01 1 10 ms Positive or Negative Logic Vin Negative 500 kHz 1500 VDC 1050 VDC 500 VDC 0.2%/°C -40 to +100°C -40 to +125°C 105 to 115°C 5 g, 10 - 55 Hz 2.1 x 106 hrs UL, cUL, VDE 2.5 oz HBS SERIES - 100 WATT MODELS - (See the last page of section for options.) MODEL HBS100YE-A HBS100YG-A HBS100YH-A HBS100YJ-A HBS100ZE-A HBS100ZG-A HBS100ZH-A HBS100ZJ-A INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) RATED OUTPUT CURRENT (AMPS) 24 24 24 24 48 48 48 48 18-36 18-36 18-36 18-36 34-75 34-75 34-75 34-75 7 7.2 7 7 3.65 3.6 3.6 3.5 3.3 5 12 15 3.3 5 12 15 30 20 8.3 6.7 30 20 8.3 6.7 RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY** 100 100 150 150 100 100 150 150 80% 83% 85% 86% 80% 84% 86% 87% NOTES: * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. MECHANICAL DRAWING " $% " " Thermal Impedance Natural Convection 6.6 °C/W 100 LFM 5.7 °C/W 200 LFM 4.2 °C/W 300 LFM 3.1 °C/W 400 LFM 2.6 °C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. " Pin 1 2 3 4 5 6 7 8 9 $% ! !! # Function -Vin Case On/Off +Vin -Vout -Sense Trim +Sense +Vout 2 Tolerances Inches: .XX ± 0.020 .XXX ± 0.010 Pin: ± 0.002 (Millimeters) .X ± 0.5 .XX ± 0.25 ± 0.05 (Dimensions as listed unless otherwise specified.) OPTIONS When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add them to the model number. Example ordering options are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, QBS, QES, QLS, TES, TQD Lucent-Compatible T HAS, HBD, HBS, HES, HLS, QBS, QES, QLS Terminal Strip TS XWS, XWD, XWT Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES Current Share 4 SMS Headerless Y Encapsulated EWS, IWS, OWS 8 All Units (Except SMS) 9 All Units (Except SMS) Pin Length and Heatsink Options 0.110" (2.8mm) Pin Length 0.150" (3.8mm) Pin Length REMARKS TTL "Low" Turns Module ON TTL "High" Turns Module OFF Standard Pin Length is 0.180" (4.6mm) 0.24" (6.1mm) Horizontal Heatsink 1H All Units (All Units Except DIP, HLS, HLD, QLS, SIP, SM, TLD, and TKD Packages) Includes Thermal Pad 0.24" (6.1mm) Vertical Heatsink 1V All Units (All Units Except DIP, HLS, HLD, QLS, SIP, SM, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Horizontal Heatsink 2H All Units (All Units Except DIP, HLS, HLD, QLS, SIP, SM, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Vertical Heatsink 2V All Units (All Units Except DIP, HLS, HLD, QLS, SIP, SM, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Horizontal Heatsink 3H All Units (All Units Except DIP, HLS, HLD, QLS, SIP, SM, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Vertical Heatsink 3V All Units (All Units Except DIP, HLS, HLD, QLS, SIP, SM, TLD, and TKD Packages) Includes Thermal Pad Example Options: HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 3