PAIRUI ALR10-22022 Ac-dc converter Datasheet

AC-DC Converter
DIP-Package
ALR-10 Series, 10Watt
FEATURES:
Universal AC input range
Short circuit, and over current protections
Board in-line type installation
High voltage isolation
Compact size
Metal/Plastic case
Model
Input voltage
(Vac)
Output voltage
(Vdc)
Output current
(mA)
Output power
(W)
5
2000
10
ALR10-22011
9
1111
10
ALR10-22012
12
833
10
ALR10-22013
24
416
10
ALR10-22014
85-265
±5
±1000
10
ALR10-22021
±9
±555
10
ALR10-22022
±12
±416
10
ALR10-22023
±24
±208
10
ALR10-22024
Note : Above models are default to plastic case, you may request for the models with metal case, plus “M” in
the suffix.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
85
--
265
Vac
Input frequency
Fline
--
47
--
63
Hz
η
Full voltage, full load
--
80
--
%
Efficiency
Output
--
Vin=100-240Vac
--
1
--
%
Line regulation
Vout-line
Vin from 100Vac to 240Vac
--
0.2
--
%
Load regulation
Vout-load
20%-100% load
--
0.5
--
%
Output voltage accuracy
www.pairuigroup.com
Page: 1 / 3
Date: 07/30/2015
*Subject to change without notice.
AC-DC Converter
DIP-Package
ALR-10 Series, 10Watt
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Ripple
Vripple
--
--
--
120
mV
--
--
--
1
--
S
Turn-on delay time
Protection
Over current
Continuous Automatic Recovery
Short circuit
Continuous Automatic Recovery
Environment
Storage
Ambient operating
temperature
Case temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 5% RH to 95% RH
-40
--
+105
℃
Ta
--
-25
--
+65
℃
Tc
--
--
--
+90
℃
Ha
Non condensing
10
--
90
%
TMTBF
--
--
--
200
kHrs
Dimension(LxWxH)
55x45x20.5mm
Safety
Input-Output: 2500Vac≦1.5mA//1min
Isolation Voltage
Input-Case: 1500Vac≦1.5mA//1min
output-Case: 1500Vac≦1.5mA//1min
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and
Vin = 100Vac to 240Vac.
www.pairuigroup.com
Page: 2 / 3
Date: 07/30/2015
*Subject to change without notice.
AC-DC Converter
DIP-Package
ALR-10 Series, 10Watt
MECHANICAL
CONNECTION
PIN #
SINGLE
DUAL
1
FG
FG
2
AC(N)
AC(N)
3
AC(L)
AC(L)
4
+Vo
+Vo1
5
No Pin
No Pin
6
No Pin
COM
7
No Pin
No Pin
8
GND
-Vo2
Note: Unit is mm(inch).
ELECTRICAL CURVE
www.pairuigroup.com
Page: 3 / 3
Date: 07/30/2015
*Subject to change without notice.