MPO-60S Series Single Output, 60W Compact, Open Frame AC/DC Power Supplies Electrical Specifications Key Features: • 60W Output Power • Universal 90-264 AC Input • EN 60950 Approved (UL) Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter • Eight Standard Models • Meets EN 55022 B Inrush Current • Meets EN 61000-4 • >200 kHour MTBF Min. Typ. Max. 90 264 127 373 47 63 Meets EN 55022 Class B; FCC Class B See Model Selection Guide Cold Start, 115 VAC 32.0 Cold Start, 230 VAC 50.0 264 VAC 3.5 Universal Input Voltage Range Input Frequency Input Filter Input Current • Compact 2 x 4 In Package Conditions Safety Ground Leakage Current Units VAC VDC Hz A Pk mA Output Parameter Output Voltage/Current Output Voltage Tolerance Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Short Circuit Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Note 1 ±1.0 Vin = Min to Max ±0.5 Iout = 10% to 100% ±1.0 See Note 2 ±1.0 115 VAC 8 230 VAC 100 ±0.05 Continuous (Autorecovery) See Note 3 150 Max. Conditions Input to Output 500 VDC Max. Units % % % % mSec %/°C % General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance EMI/RFI Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Fixed EMC Compliance Switching Frequency Min. 3,000 Typ. Units VAC 1,000 M⍀ 4,700 pF EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 66 kHz Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Size Weight Conditions Min. Typ. Max. 0 +25 +50 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Units °C °C % 4.00 x 2.00 x 1.20 Inches (101.60 x 50.08 x 30.48 mm) 5.21 Oz (0.150 kg) Reliability Specifications Parameter MTBF Safety Standards Vibration Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 200 kHours UL 1950, EN 60950 Sinusoidal 50~500 Hz, 3.0 Grms, Period of 30 min each along X, Y & Z Axis www.micropowerdirect.com www.micropowerdirect.com Model Selection Guide Model Number MPO-60S-03 MPO-60S-05 MPO-60S-09 MPO-60S-12 MPO-60S-138 MPO-60S-15 MPO-60S-24 MPO-60S-48 Input Current (A) 115 VAC 230 VAC 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Voltage (VDC) Output Current (A) Rated 3.3 5.0 9.0 12.0 13.8 15.0 24.0 48.0 8.00 8.00 6.67 5.00 4.35 4.00 2.50 1.25 % Min. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Max Output Power Max Output Capacitance (W) (µF) 26 40 60 60 60 60 60 60 8,800 8,800 6,670 5,000 3,600 3,600 2,500 770 Efficiency (%, Typ) 74 78 82 84 83 85 86 88 Derating Curve Other Models Are Available. Contact The Factory For Details Notes: 1. Output voltage tolerance is measured at nominal input and 60% load. 2. Output ripple is measured at 20 MHz bandwidth using 0.1 µF and 10 µF capacitors connected in parallel as close to the power supply terminals as possible. 3. Overload protection is provided by an internal “hiccup” circuit. The unit recovers automatically when the fault condition is removed. 4. These units will operate at no load without damage. For most applications however, MPD recommends that a minimum load always be used. Contact the factory for more information. 5. Each unit includes an input fuse (250V/2A). Since this fuse is not field replaceable, it is recommended that an external fuse of the same size be used on the input of the power supply for protection. Mechanical Dimensions Connections Input Connector (CN1): • Molex 5273-03A or equivalent (one pin removed) • Mating Housing: Molex 5195-03 or equivalent • Mating Terminal: Molex 5293 or equivalent Pin 1 2 3 Function AC-Neutral Removed AC-Line Safety Ground: The mounting holes marked “Use metal standoffs” should be connected to the system earth ground via metal spacers or a cable. The input side mounting hole marked “FG” provides the safety earth ground for the unit. This connection should be locked to prevent possible loosening. Connecting the output side mounting hole improves EMI. Output Connector (CN2): • Molex 5273-04A or equivalent • Mating Housing: Molex 5195-04 or equivalent • Mating Terminal: Molex 5293 or equivalent Pin 1 2 3 4 Function +VOUT +VOUT -VOUT -VOUT Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]