Mean Well HLP-40H-48 40w single output switching power supply Datasheet

HLP-40H
40W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Output constant current level adjustable
100% full load burn-in test
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp location
3 years warranty
M
M
SELV
SPECIFICATION
HLP-40H-12 HLP-40H-15 HLP-40H-20 HLP-40H-24 HLP-40H-30 HLP-40H-36 HLP-40H-42 HLP-40H-48 HLP-40H-54
MODEL
12V
DC VOLTAGE
CONSTANT CURRENT REGION Note.4 7.2 ~12V
48V
54V
25.2 ~ 42V
28.8 ~ 48V
32.4 ~ 54V
1.12A
0.96A
0.84A
0.75A
1.67A
RATED POWER
40W
40W
40W
40.1W
40.2W
40.3W
40.3W
40.3W
40.5W
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
300mVp-p
300mVp-p
300mVp-p
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
40 ~ 46V
44 ~ 53V
49 ~ 58V
10.8 ~ 13.5V 13.5 ~ 17V
Can be adjusted by internal potential meter or through output cable
CURRENT ADJ. RANGE
2 ~ 3.33A
1.6 ~ 2.67A
1.2 ~ 2A
1 ~ 1.67A
0.8 ~ 1.34A
0.67 ~ 1.12A 0.58 ~ 0.96A 0.5 ~ 0.84A
1.0%
1.0%
1.0%
0.45 ~ 0.75A
VOLTAGE TOLERANCE Note.3
2.5%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
1.0%
2.0%
Note.6 1500ms, 80ms / 115VAC at full load
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
VOLTAGE RANGE
16ms/230VAC
Note.5 90 ~ 305VAC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF 0.95/230VAC
EFFICIENCY (Typ.)
87%
AC CURRENT (Typ.)
INRUSH CURRENT(Typ.)
OVER CURRENT
Note.4
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
1000ms, 80ms / 230VAC at full load
16ms/115VAC at full load
127 ~ 431VDC
PF 0.98/115VAC at full load and rated output voltage
88%
87%
0.43A / 115VAC
0.24A / 230VAC
COLD START 70A/230VAC
89%
88%
0.23A / 277VAC
89%
PF 0.9 at 60 ~ 100% load
89.5%
89.5%
90%
54 ~ 63V
59 ~ 66V
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
41 ~ 49V
18 ~ 24V
17.5 ~ 30V
23 ~ 30V
35 ~ 43V
48 ~ 58V
28 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
85
10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.03%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL8750, EN61347-1, EN61347-2-13 approved ; Design refer to UL60950-1, TUV EN60950-1, EN60335-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC EMISSION
EMC IMMUNITY
MTBF
DIMENSION
PACKING
1.0%
<0.75mA / 277VAC
LEAKAGE CURRENT
NOTE
42V
21.6 ~ 36V
2A
HOLD UP TIME (Typ.)
OTHERS
36V
2.67A
SETUP, RISE TIME
EMC
30V
14.4 ~ 24V
3.33A
LOAD REGULATION
SAFETY &
24V
12 ~ 20V
RATED CURRENT
VOLTAGE ADJ. RANGE
INPUT
20V
9 ~ 15V
18 ~ 30V
1.34A
RIPPLE & NOISE (max.) Note.2 150mVp-p
OUTPUT
15V
I/P-FG:1.88KVAC
O/P-FG:0.5KVAC
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
287.9Khrs min. MIL-HDBK-217F (25 )
147*53*27mm (L*W*H)
0.2Kg;72pcs/15.4Kg/1.09CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name:HLP-40H-SPEC 2011-06-03
HLP-40H
40W Single Output Switching Power Supply
Mechanical Specification
series
Unit:mm
147
3.5
53
43
5
140
CN2
6
5
4
3
2
1
FS1
T3.15A/300V
Io
ADJ
Vo
ADJ
3max.
27max.
CN1
6
5
4
3
2
1
AC Input Connector (CN1) : JST B6P-VH or equivalent
Pin No.
1
2,4,5
3
6
Assignment
AC/L
No Pin
AC/N
FG
DC Output Connector (CN2) : JST B6P-VH or equivalent
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Pin No.
1
2
3,4
5,6
Assignment
DIM+
DIM-V
+V
Mating Housing
Terminal
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Block Diagram
fosc : 100KHz
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
PFC
CIRCUIT
+V
-V
DIM+
DIM(B Type)
O.L.P.
O.T.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM & PFC
CONTROL
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
230VAC
Input only
70
50
LOAD (%)
LOAD (%)
60
40
20
-40
-25
-10
0
15
30
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
90
100
125
135
145
155 165
175
180
200
230
305
INPUT VOLTAGE (V) 60Hz
File Name:HLP-40H-SPEC 2011-06-03
40W Single Output Switching Power Supply
HLP-40H
series
Power Factor Characteristic
Constant Current Mode
1
0 .9 9
0 .9 8
0 .9 7
0 .9 6
0 .9 5
PF
0 .9 4
0 .9 3
277VAC
0 .9 2
230VAC
0 .9 1
110VAC
0 .9
0 .8 9
0 .8 8
0 .8 7
0 .8 6
0 .8 5
50%
60%
70%
80%
90%
100%
(40W)
LOAD
EFFICIENCY vs LOAD (48V Model)
HLG-40H series possess superior working efficiency that up to 90% can be reached in field applications.
92
90
EFFICIENCY (%)
88
86
84
82
277VAC
80
230VAC
78
110VAC
76
74
72
70
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
LOAD
DRIVING METHODS OF LED MODULE
There are two major kinds of LED drive method "direct drive" and "with LED driver".
A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
(B)
Constant
Current area
Vo(%)
100
(A) Constant
Voltage area
60
(max.)
(C)
Hiccup
Protection
50
95
Io (%)
Typical LED power supply I-V curve
File Name:HLP-40H-SPEC 2011-06-03
HLP-40H
40W Single Output Switching Power Supply
series
DIMMING OPERATION
FG
+V
+V
-V
-V
DIMDIM+
AC/N
AC/L
Output constant current level can be adjusted through output connector by 1~10VDC, PWM signal, or connecting a resistance
between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V".
Reference resistance value for output current adjustment (Typical)
OPEN
10K
20K
30K
40K
50K
70K
80K
90K
Single driver
60K
100K
Resistance
Multiple
drivers
value
(N=driver quantity for synchronized 10K
/N 20K /N 30K /N 40K /N 50K /N 60K /N 70K /N 80K /N 90K /N 100K /N
-----
dimming operation)
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~105%
1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V
2V
3V
4V
5V
6V
7V
8V
9V
10V
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~105%
10V PWM signal for output current adjustment (Typical): Frequency range :100HZ ~ 3KHz
Duty value
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
OPEN
Percentage of rated current
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
95%~105%
Using the built-in dimming function can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness
of the lighting fixture connecting to the LED power supply unit.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N
FG
L
Switch
Relay
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Green/
Yellow
Brown
Blue
AC/L
AC/N
HLP-40H
DIM+
DIMV(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output connector by connecting a resistor or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:HLP-40H-SPEC 2011-06-03