Meder MK16-B-1 Reed sensors for smd mounting Datasheet

MEDER electronic
MK16 Series
Reed Sensors for
SMD Mounting
DESCRIPTION
MK16 are magnetically operated Reed proximity
switches for SMD mounting.
• Lead design 1:
Flat, straight leads for PCB slot mounting.
• Lead design 2:
Flat, bent SMD leads.
The sensors are supplied taped & reeled according
to IEC 286/part 3 suitable for auto-placement.
The special features of this series are the small
dimensions of only 15.6 x 2.3 x 2.3 mm and the
simple internal structure (low-cost version).
APPLICATIONS
• Electronic PCB’s where all components are
surface mounted
• Telecommunication applications
Hook switch in mobile and hard-wired phones
• Switching element in microphones
FEATURES
•
•
•
•
•
Four operate sensitivities available
Tape and Reel available
Excellent for low power operations
No external power required for sensor operation
UL approved
DIMENSIONS
All dimensions in mm [inch]
Recommended
Pad Layout
ORDER INFORMATION
Series
Magnetic
Sensitivity
Lead
Design
MK16 -
X-
X
Options
B, C, D, E
1.2
Part Number Example
MK16 - B - 1
B is the magnetic sensitivity
1 is the lead design
Sensitivity
class
Pull In
AT Range
B
10 - 15
C
15 - 20
D
20 - 25
E
25 - 30
www.meder.com
257
MEDER electronic
MK16 Series
Reed Sensors for
SMD Mounting
TAPE & REEL
SOLDERING INFORMATION
reflow soldering conditions according JEDEC norm J-STD-020C
40 s
260 oC
183 oC
125 oC
Ramp up:
max. 6K/s
120 s
120-180 s
www.meder.com
258
Ramp down:
max. 8/Ks
MK16 Series
MEDER electronic
Reed Sensors for
SMD Mounting
CONTACT DATA
All Data at 20° C
Contact Form →
Contact Ratings
Conditions
Form A
Min.
Typ.
Max. Units
Switching Power
Any DC combination of V & A not to
exceed their individual max.‘s
10
W
Switching Voltage
DC or peak AC
200
V
Switching Current
DC or peak AC
0.5
A
Carry Current
DC or peak AC
0.5
A
Static Contact Resistance
w/ 0.5 V & 10 mA
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5 V & 50 mA ,
1.5 ms after closure
200
mΩ
Insulation Resistance across Contacts
100 volts applied
1012
Ω
Breakdown Voltage across Contact
Voltage applied for 60 sec. min.
230
VDC
Operate Time incl. Bounce
Measured w/ 100 % overdrive
0.6
ms
Release Time
Measured w/ no coil suppression
0.1
ms
Capacitance
at 10 kHz cross contact
0.2
pF
Contact Operation *
Must Operate Condition
Steady state field
10
30
AT
Must Release Condition
Steady state field
4
18
AT
g
Environmental Data
Shock Resistance
1/2 sinus wave duration 11 ms
30
Vibration Resistance
From 10 - 2000 Hz
20
Ambient Temperature
10°C/ minute max. allowable
-40
Stock Temperature
10°C/ minute max. allowable
-50
Soldering Temperature
5 sec. dwell
g
130
o
C
130
o
C
360
o
C
Please note: The indicated electrical data are maximum values and can vary downwards when using a more
sensitive switch.
* These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if
more detail is required.
www.meder.com