FR101 thru FR107 REVERSE VOLTAGE - 50 to 1000 Volts FORWARD CURRENT - 1.0 Amperes FAST RECOVERY RECTIFIERS DO-41 FEATURES Fast switching for high efficiency Low cost Diffused junction Low reverse leakage current Low forward voltage drop High current capability The plastic material carries UL recognition 94V-0 A B A C D DO-41 MECHANICAL DATA Dim. A Case : JEDEC DO-41 molded plastic Polarity : Color band denotes cathode Weight : 0.012 ounces, 0.34 grams Mounting position : Any Min. B 25.4 4.20 C 0.70 Max. 5.20 0.90 2.00 2.70 D All Dimensions in millimeter MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25ΜΊ ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20% SYMBOL FR101 CHARACTERISTICS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current @TA=55 C Peak Forward Surge Current 8.3ms single half sine-wave super imposed on rated load (JEDEC Method) Maximum forward Voltage at 1.0A DC Maximum DC Reverse Current at Rated DC Blocking Voltage @TJ =25 C @TJ =100 C Maximum Reverse Recovery Time (Note 1) Typical Junction Capacitance (Note 2) Typical Thermal Resistance (Note 3) Operating Temperature Range Storage Temperature Range VRRM VRMS VDC 50 35 50 FR102 FR103 FR104 FR105 FR106 FR107 UNIT 100 70 100 200 140 200 400 280 400 600 420 600 800 560 800 1000 700 1000 V V V I(AV) 1.0 A IFSM 30 A VF 1.3 V 5.0 100 uA IR TRR 150 uA 250 500 ns CJ 15 pF R0JA 30 C/W TJ -55 to +150 C TSTG -55 to +150 C NOTES : 1.Measured with IF=0.5A,IR=1A,IRR=0.25A. 2.Measured at 1.0MHz and applied reverse voltage of 4.0V DC. 3.Thermal Resistance Junction to Case at 9.5mm Lead Length.PCB Mounted JEDEC Registered Value. 1 of 2 FR101 thru FR107 FR101 thru FR107 FIG . 1 - MAXIMUM TYPICAL FORWARD CURRENT DERATING CURVE 1.0 .75 .50 .25 SINGLE PHASE HALF WAVE 60Hz RESISTIVE OR INDUCTIVE LOAD 0.375" (9.5 mm) LEAD LENGTH 00 25 50 75 100 125 150 FIG . 2 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PEAK FORWARD SURGE CURRENT . ( A ) AVERAGE FORWARD CURRENT. ( A ) RATING AND CHARACTERISTIC CURVES 175 50 40 30 8.3ms Single Half Sine Wave JEDEC Method 20 10 0 1 2 O FIG 3 . - TYPICAL FORWARD CHARACTERISTICS 100 10 Pulse Width=300 1% Duty Cycle 4 6 8 10 20 40 60 80 100 NUMBER OF CYCLES AT 60Hz FIG . 4 - TYPICAL HUNCTION CAPACITANCE 20 HUNCTION CAPACITANCE . (pF) INSTANTANEOUS FORWARD CURRENT . ( A ) AMBIENT TEMPERATURE . ( C ) s 3.0 1.0 0.3 60 40 20 Tj=25OC 10 0.1 1 2 4 6 10 20 40 60 REVERSE VOLTAGE . ( V ) 100 .03 .01 .4 .6 .8 1.0 1.2 1.4 1.6 FORWARD VOLTAGE . (V ) 1.8 FIG . 1 -REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM 10 50 NONINDUCTIVE NONINDUCTIVE trr +0.5A (+ ) 50Vdc (approx) (-) DUT PULSE GENERATOR ( NOTE 2 ) NONINDUCTIVE 0 -0.25A OSCILLOSCOPE (NOTE 2 ) -1.0A NOTES: 1 . RISE TIME = 7nsmax. INPUT IMPEDANCE= 1 MEGOHM 22pf 2 . RISETIME = 10ns max.SOURSE IMPEDANCE = 50ohmsf 1cm 2 of 2 SET TIME BASE FOR 5/ 10ns / cm FR101 thru FR107