ILX524K 2700 × 3pixel CCD Linear Sensor (Color) For the availability of this product, please contact the sales office. Description The ILX524K is a reduction type CCD linear sensor developed for color image scanner. This sensor reads legal-size documents at a density of 300 DPI. φ1 8 15 φ2 NC 9 14 NC φ1 11 Driver S2700 S2700 Red Green GND φROG-R φROG-G 12 Driver 10 φROG-B 13 8 4 20 A A A A A A AA AA φLH VDD S2700 16 1 VOUT-R 1 VOUT-G 22 VOUT-B 21 B 1 G 1 R D14 D15 13 φROG-B 2700 2700 2700 φROG-R 10 GND 11 5 16 VDD GND 7 3 NC φRS 17 NC 2 6 GND NC Driver 18 NC Read Out Gate 5 CCD Register GND Read Out Gate 19 NC CCD Register 4 Read Out Gate φLH CCD Register 20 VDD Driver 15 φ2 VDD Blue 3 D14 D15 φRS D15 21 VOUT-B D14 2 D63 S1 GND 22 VOUT-G D63 S1 1 D63 S1 D64 VOUT-R D64 Pin Configuration (Top View) D64 V °C °C D75 15 –10 to +55 –30 to +80 D75 Absolute Maximum Ratings • Supply voltage VDD • Operating temperature • Storage temperature Block Diagram D75 Features • Number of effective pixels: 8100 pixels (2700 pixels × 3) • Pixel size: 8µm × 8µm (8µm pitch) • Distance between line: 64µm (8 Lines) • Single-sided readout • Ultra low lag / High sensitivity • Single 12V power supply • Input clock pulse: CMOS 5V drive • Number of output 3 (R, G, B) • Package: 22 pin cer-DIP (400 mil) 22 pin DIP (Cer-DIP) 12 φROG-G Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits. –1– E95815-PK ILX524K Pin Description Pin No. Symbol Description Pin No. Symbol Description 1 VOUT-R Signal out (red) 12 φROG-G Clock pulse input 2 GND GND 13 φROG-B Clock pulse input 3 φRS Clock pulse input 14 NC NC 4 φLH Clock pulse input 15 φ2 Clock pulse input 5 GND GND 16 VDD 12V power supply 6 NC NC 17 NC NC 7 NC NC 18 NC NC 8 φ1 Clock pulse input 19 NC NC 9 NC NC 20 VDD 12V power supply 10 φROG-R Clock pulse input 21 VOUT-B Signal out (blue) 11 GND GND 22 VOUT-G Signal out (green) Recommended Supply Voltage Item Min. Typ. Max. Unit VDD 11.4 12.0 12.6 V Clock Characteristics Item Symbol Min. Typ. Max. Unit Input capacity of φ1, φ2 Cφ1, Cφ2 — 400 — pF Input capacity of φLH CφLH — 10 — pF Input capacity of φRS CφRS — 10 — pF Input capacity of φROG∗ CφROG — 10 — pF ∗ It indicates that φROG-R, φROG-G, φROG-B as φROG. Clock Frequency Item Symbol φ1, φ2, φLH, φRS Min. Typ. Max. Unit — 1 5 MHz fφ1, fφ2, fφLH, fφRS Input Clock Pulse Voltage Condition Item φ1, φ2, φLH, φRS, φROG pulse voltage Min. Typ. Max. Unit High level 4.75 5.0 5.25 V Low level — 0 0.1 V –2– ILX524K Electrooptical Characteristics (Note 1) Ta = 25°C, VDD = 12V, fφRS = 1MHz, Input clock = 5Vp-p, Light source = 3200K, IR cut filter CM-500S (t = 1.0mm) Item Symbol Min. Typ. Max. Unit Remarks V/(lx · s) Note 2 Red RR 1.3 2.0 2.7 Green RG 2.1 3.2 4.3 Blue RB 1.6 2.5 3.4 Sensitivity nonuniformity PRNU — 4 20 % Note 3 Saturation output voltage VSAT 2 3.2 — V Note 4 Red SER 0.74 1.6 — Green SEG 0.46 1 — lx · s Note 5 Blue SEB 0.58 1.28 — Dark voltage average VDRK — 0.3 2 mV Note 6 Dark signal nonuniformity DSNU — 1.5 5 mV Note 6 Image lag IL — 0.02 — % Note 7 Supply current IVDD — 26 50 mA — Total transfer efficiency TTE 92 98 — % — Output impedance ZO — 250 — Ω — Offset level VOS — 6.5 — V Note 8 Dynamic range DR 1000 10670 — — Note 9 Sensitivity Saturation exposure Note 1) In accordance with the given electrooptical characteristics, the black level is defined as the average value of D2, D3 to D12. 2) For the sensitivity test light is applied with a uniform intensity of illumination. 3) PRNU is defined as indicated below. Ray incidence conditions are the same as for Note 2. VOUT-G = 500mV (Typ.) PRNU = (VMAX – VMIN) /2 VAVE × 100 [%] Where the 2700 pixels are divided into blocks of 100. The maximum output of each block is set to VMAX, the minimum output to VMIN and the average output to VAVE. 4) Use below the minimum value of the saturation output voltage. 5) Saturation exposure is defined as follows. SE = VSAT R Where R indicates RR, RG, RB, and SE indicates SER, SEG, SEB. 6) Optical signal accumulated time τint stands at 10ms. VOUT 7) VOUT-G = 500mV (Typ.) 8) Vos is defined as indicated bellow. VOUT indicates VOUT-R, VOUT-G, and VOUT-B. VOS 9) Dynamic range is defined as follows. DR = VSAT VDRK AA AA AAAA GND When the optical signal accumulated time is shorter, the dynamic range gets wider because the optical signal accumulated time is in proportion to the dark voltage. –3– –4– VOUT φRS φ2 φ1 φLH φROG D3 D2 3 D1 2 1 VOUT indicates VOUT-R, VOUT-G, VOUT-B. AAAAAAA A D62 D15 D14 D13 4 Dummy signal (63 pixels) S2699 S2698 S2 S1 D63 1-line output period (2775 pixels) Optical black (49 pixels) D61 Note) The transfer pulses (φ1, φ2, φLH) must have more than 2775 cycles. 0 5 0 5 0 5 0 5 Clock Timing Chart 1 ILX524K D75 2775 D71 D70 D65 D64 S2700 ILX524K Clock Timing Chart 2 t4 t5 φROG t2 t6 t7 φ1 t1 t3 φ2 Clock Timing Chart 3 t7 t6 φ1 φLH φ2 t10 t11 t9 φRS t8 t13 VOUT AAAAAAAA AAAAAAAA AAAAAAAA t12 –5– AAA AAA AAA ILX524K Clock Pulse Recommended Timing Symbol Item φROG, φ1 pulse timing t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11 t12 φROG pulse high level period φROG, φ1 pulse timing φROG pulse rise time φROG pulse fall time φ1 pulse rise time /φ2 pulse fall time φ1 pulse fall time /φ2 pulse rise time φRS pulse high level period φRS, φLH pulse timing φRS pulse rise time φRS pulse fall time Signal output delay time t13 ∗ These timing is the recommended condition under fφRS = 1MHz. –6– Min. Typ. Max. Unit 50 100 — ns 800 1000 — ns 800 1000 — ns 0 5 10 ns 0 5 10 ns 0 20 60 ns 0 20 60 ns — ns — ns 45 250∗ 250∗ 0 10 30 ns 0 10 30 ns — 10 — ns — 10 — ns 45 47µF/16V Tr1 ∗ Data rate fφRS = 1MHz. 0.1µF 12V VOUT-G Tr1 2 1 100Ω 100Ω φLH 4 7 6 2Ω φ1 8 9 φROG-R 10 IC1 11 IC1 IC1: 74AC04 Tr1: 2SC2785 Application circuits shown are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits or for any infringement of third party patent and other right due to same. φRS 3 5 12 13 14 15 16 17 18 19 φROG-G 20 2Ω φROG-B 21 Tr1 VOUT-B φ2 22 100Ω 5.1kΩ VOUT-G 5.1kΩ 100Ω 100Ω VOUT-R 5.1kΩ VOUT-B VOUT-R VDD GND NC φRS NC φLH NC GND VDD NC –7– NC φ2 φ1 NC NC φROG-B φROG-R φROG-G GND Application Circuit∗ ILX524K ILX524K Example of Representative Characteristics (VDD = 12V, Ta = 25°C) Spectral sensitivity characteristics (Standard characteristics) 1 Relative sensitivity 0.8 0.6 0.4 0.2 0 400 450 500 550 600 650 700 Wavelength [nm] Dark signal output temperature characteristics (Standard characteristics) Integration time output voltage characteristics (Standard characteristics) 10 Output voltage rate Output voltage rate 5 1 0.5 1 0.5 0.1 0.1 0 10 20 30 40 50 60 5 1 10 Ta – Ambient temperature [°C] τint – Integration time [ms] Offset level vs. VDD characteristics (Standard characteristics) Offset level vs. temperature characteristics (Standard characteristics) 12 12 Ta = 25°C 10 VOS – Offset level [V] VOS – Offset level [V] 10 8 6 ∆VOS ∆VDD 4 0.3 2 0 11.4 8 6 ∆VOS ∆Ta 4 –0.5mV/°C 2 0 12 12.6 0 VDD [V] 10 20 30 40 50 Ta – Ambient temperature [°C] –8– 60 ILX524K Notes of Handling 1) Static charge prevention CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following protective measures. a) Either handle bare handed or use non chargeable gloves, clothes or material. Also use conductive shoes. b) When handling directly use an earth band. c) Install a conductive mat on the floor or working table to prevent the generation of static electricity. d) Ionized air is recommended for discharge when handling CCD image sensor. e) For the shipment of mounted substrates, use boxes treated for prevention of static charges. 2) Notes on Handling CCD Cer-DIP Packages The following points should be observed when handling and installing cer-DIP packages. a) Remain within the following limits when applying static load to the ceramic portion of the package: (1) Compressive strength: 39N/surface (Do not apply load more than 0.7mm inside the outer perimeter of the glass portion.) (2) Shearing strength: 29N/surface (3) Tensile strength: 29N/surface (4) Torsional strength: 0.9Nm b) In addition, if a load is applied to the entire surface by a hard component, bending stress may be generated and the package may fracture, etc., depending on the flatness of the ceramic portion. Therefore, for installation, either use an elastic load, such as a spring plate, or an adhesive. AAAA AAAA AAAA AAAA AAAA AAAA AAAA AAAA Upper ceramic layer 39N lower ceramic layer (1) Low-melting glass 29N 29N (2) (3) 0.9Nm (4) c) Be aware that any of the following can cause the glass to crack: because the upper and lower ceramic layers are shielded by low-melting glass, (1) Applying repetitive bending stress to the external leads. (2) Applying heat to the external leads for an extended period of time with soldering iron. (3) Rapid cooling or heating (4) Rapid cooling or impact to a limited portion of the low-melting glass with a small-tipped tool such as tweezers. (5) Prying the upper or lower ceramic layers away at a support point of the low-melting glass. Note that the preceding notes should also be observed when removing a component from a board after it has already been soldered. 3) Soldering a) Make sure the package temperature does not exceed 80°C. b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a grounded 30W soldering iron and solder each pin in less then 2 seconds. For repairs and remount, cool sufficiently. c) To dismount an imaging device, do not use a solder suction equipment. When using an electric desoldering tool, ground the controller. For the control system, use a zero cross type. –9– ILX524K 4) Dust and dirt protection a) Operate in clean environments. b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized air is recommended.) c) Clean with a cotton bud and ethyl alcohol if the glass surface is grease stained. Be careful not to scratch the glass. d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when moving to a room with great temperature differences. 5) Exposure to high temperatures or humidity will affect the characteristics. Accordingly avoid storage or usage in such conditions. 6) CCD image sensors are precise optical equipment that should not be subject to mechanical shocks. – 10 – 5.0 ± 0.5 – 11 – 1 V 22 H 6.53 ± 0.8 21.6 (8µm × 2700Pixels) 32.0 ± 0.5 2.54 Cer-DIP TIN PLATING 42 ALLOY 3.0g PACKAGE MATERIAL LEAD TREATMENT LEAD MATERIAL PACKAGE WEIGHT 30.6 No.1 Pixel (Green) PACKAGE STRUCTURE 4.0 ± 0.5 11 12 0.51 22pin DIP (400mil) 9.0 2.7 Unit: mm 10.0 ± 0.5 0.3 3.5 ± 0.5 Package Outline M 0° to 9° 0.25 (AT STAND OFF) 10.16 2. The thickness of the cover glass is 0.8mm, and the refractive index is 1.5. 1. The height from the bottom to the sensor surface is 1.61 ± 0.3mm. ILX524K