EPCOS B84112B0000L110 2-line filters sifi-b for enhanced insertion loss rated current 1 to 20 a Datasheet

EMC filters
2-line filters
SIFI-B for enhanced insertion loss
Rated current 1 to 20 A
Series/Type:
B84112B
Date:
January 2006
 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the
information contained therein without EPCOS’ prior express consent is prohibited.
2-line filters
B84112B
SIFI-B for enhanced insertion loss
Power line filters for 1-phase systems
Rated voltage 250 V DC/AC, 50/60 Hz
Rated current 1 to 20 A
Alternative version
■ Series B84112G (SIFI-G)
offers a low-cost solution
Construction
■ 2-line filters
■ Metal case
■ Polyurethane potting (UL 94 V-0)
Features
■
■
■
■
■
Compact design
Optimized leakage current
Cost-optimized construction
Also for assembly on top-hat rails
ENEC10, UL and CSA approval
Applications
■ Switch-mode power supplies in
– industrial electronics
– telecommunications
– data systems
– medical equipment
■ DC applications
Case styles and terminal styles
Case style A
Tab connectors on face ends, lateral fixing lugs.
Particularly suitable for mounting on a shielding wall.
Case style B
Tab connectors on face ends, fixing lugs on face ends.
Case style K
IEC connector as per IEC 60320 C 14 on line side,
tab connectors on load side, mounting holes with metric thread.
Case style L
Litz wires on face ends, fixing lugs on face ends
Case style P
Pins fitting PCB standard grid
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current, rated temperature,
climatic category, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Please read Cautions and warnings and
Important notes at the end of this document.
2
01/06
2-line filters
B84112B
SIFI-B for enhanced insertion loss
Circuit diagram
LINE
L
LOAD
L’
N
N’
SSB0525-W
Technical data and measuring conditions
Rated voltage VR
250 V DC/AC, 50/60 Hz
Rated current IR
Referred to 40 °C ambient temperature
Test voltage Vtest
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Leakage current lleak
At 230 V AC, 50 Hz
Climatic category (IEC 60068-1)
25/085/21 (–25 °C/+85 °C/21 days damp heat test)
Approvals
EN 133200, UL 1283, CSA C22.2 No.8
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
2-line filters
B84112B
SIFI-B for enhanced insertion loss
Characteristics and ordering codes
IR
CR
A
LR
Ileak
mH
mA
Case Approx. Ordering code
style weight
g
Mounting plate
for top-hat rail
(ordering code)
VR = 250 V DC/AC, 50/60 Hz
1
2 × 0.15 µF (X2)
+
2 × 4700 pF (Y2)
2×
10
< 0.5 A
B
K
L
110
110
140
110
B84112B0000A010
B84112B0000B010
B84112B0000K010
B84112B0000L010
2
2 × 0.15 µF (X2)
+
2 × 4700 pF (Y2)
2×
10
< 0.5 A
B
L
110
110
110
B84112B0000A020 —
B84112B0000B020 C62122A0132B091
B84112B0000L020 —
3
2 × 0.22 µF (X2)
+
2 × 4700 pF (Y2)
2×
10
< 0.5 A
B
K
L
P
140
140
210
140
140
B84112B0000A030
B84112B0000B030
B84112B0000K030
B84112B0000L030
B84112B0000P030
—
C62122A0132B092
—
—
—
6
2 × 0.33 µF (X2)
+
2 × 4700 pF (Y2)
2×
3.3
< 0.5 A
B
K
L
150
150
210
150
B84112B0000A060
B84112B0000B060
B84112B0000K060
B84112B0000L060
—
C62122A0132B092
—
—
10
2 × 0.47 µF (X2)
+
2 × 4700 pF (Y2)
2×
1.8
< 0.5 A
B
L
200
200
200
B84112B0000A110 —
B84112B0000B110 C62122A0132B092
B84112B0000L110 —
20
2 × 0.68 µF (X2)
+
2 × 4700 pF (Y2)
2×
1.8
< 0.5 A
B
700
700
B84112B0000A120 —
B84112B0000B120 C62122A0132B092
Please read Cautions and warnings and
Important notes at the end of this document.
4
01/06
—
C62122A0132B091
—
—
2-line filters
B84112B
SIFI-B for enhanced insertion loss
Case styles and dimensions
Case
style
IR
Dimensions (mm)
b2
b3
b4
b1
l1
l2
l3
l4
h1
h2
Litz
mm2
Style
1015
50
50
63.5
50
—
60.4
—
60.4
—
70
—
70
76.5
76.5
—
—
28.6
28.6
32
28.6
20
20
—
—
—
—
—
0.82
—
—
—
AWG18
—
—
60.4 70
60.4 70
76.5 28.6 20
76.5 28.6 20
—
28.6 —
—
—
0.82
—
—
AWG18
A
A
B
K
L
1
1
1
1
45
45
51
45
26.5
26.5
—
—
60.4
—
—
—
70
—
—
—
A
B
L
2
2
2
45
45
45
26.5 60.4 70
26.5 —
—
—
—
—
50
50
50
A
B
K
L
P
3
3
3
3
3
50.8
50.8
50.8
50.8
31.5
31.5
—
—
60.4
—
—
—
70
—
—
—
63.5 —
—
89.5 28.6
63.5 74.7 84.5 89.5 28.6
79.5 —
—
—
32
63.5 74.7 84.5 —
28.6
See dimensional drawing
20
20
—
—
—
—
—
0.82
—
—
—
AWG18
A
B
K
L
6
6
6
6
50.8
50.8
50.8
50.8
31.5
31.5
—
—
60.4
—
—
—
70
—
—
—
63.5
63.5
79.5
63.5
20
20
—
—
—
—
—
0.82
—
—
—
AWG18
A
B
L
10
10
10
63.5 —
—
89.5 38.1 28
63.5 74.7 84.5 89.5 38.1 28
63.5 74.7 84.5 —
38.1 —
—
—
1.35
—
—
AWG16
A
B
20
20
50.8 31.5 60.4 70
50.8 31.5 —
—
50.8 —
—
—
Please read Cautions and warnings and
Important notes at the end of this document.
—
74.7
—
74.7
—
84.5
—
84.5
89.5
89.5
—
—
28.6
28.6
32
28.6
See dimensional drawing
5
01/06
2-line filters
B84112B
SIFI-B for enhanced insertion loss
Case style A
Case style A
1 … 10 A (B84112B0000A010 … A110)
20 A (B84112B0000A120)
b1
b2
28
38.1
50.8
4
1
6.3
ø4.7
95.2
105
b3
b4
SSB0253-I-E
SSB0527-D-E
Case style B
Case style B
1 … 10 A (B84112B0000B010 … B110)
20 A (B84112B0000B120)
Tab connector A6.3 x 0.8
ø4.7
38.1
28
0.8
h1
84
31.5
0.8
50.8
SSB0528-L-E
Please read Cautions and warnings and
Important notes at the end of this document.
6
01/06
ø4.7
125
118
99
3
2
Tab connector A6.3 x 0.8
108
h2
b1
b2
1
125
0.8
Tab connector A6.3 x 0.8
4.3
Tab connector A6.3 x 0.8
4
99
h1
h2
0.8
84
31.5
SSB0254-R-E
2-line filters
B84112B
SIFI-B for enhanced insertion loss
Case style K
Case style L
b1
16
0.8
h1
16±1
M4
h1
3.4±1
10±1
4±1
b1
40
105+15
ø4.7
1
3
2
1
13
BN
BU
6 _2
Tab connector A6.3 x 0.8
GNYE
6 _2
20.5
3
31.5
19
28.5
40±0.2
Case style P
Output
Ground
63.4
10±0.2
28.6±0.8
32.5±0.2
35±0.2
10.45±0.3
7.9±0.3
Input
0.8
4.5±0.5
50.8
ø1.2+0.1
BU
SSB0255-Z-E
SSB0529-U-E
8.3+0.2
BN
105+15
Panel cutout
ø4.5
SSB0256-8-E
Please read Cautions and warnings and
Important notes at the end of this document.
7
01/06
2-line filters
B84112B
SIFI-B for enhanced insertion loss
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 1 A and 2 A
α
Filters for 3 A
SSB0249-Q
100
dB B84112B0000*010
B84112B0000*020
α
80
80
60
60
40
40
20
20
0
10 4
10 5
10 6
10 7
0
10 4
Hz 10 8
f
Filters for 6 A and 10 A
α
SSB0252-A
10 6
100
dB B84112B0000*120
10 7
Hz 10 8
f
80
60
60
40
40
20
20
10 6
SSB0251-2
α
80
10 5
10 5
Filters for 20 A
100
dB B84112B0000*060
B84112B0000*110
0
10 4
SSB0250-T
100
dB B84112B0000*030
10 7
0
10 4
Hz 10 8
f
Please read Cautions and warnings and
Important notes at the end of this document.
8
01/06
10 5
10 6
10 7
Hz 10 8
f
EMC filters
Cautions and warnings
Important information
Please read all safety and warning notes carefully before installing the EMC filter and putting it into
operation (see
). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro­
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in low­
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warnings
■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
■
■
■
■
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
Danger of electric shock. EMC filters contain components that store an electric charge. Danger­
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
The protective earth connections shall be the first to be made when the EMC filter is installed and
the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen­
cies that may cause resonances etc. can lead to destruction of the filter housing.
EMC filters must be protected in the application against impermissible exceeding of the rated
currents by suitable overcurrent protective.
9
01/06
EMC filters
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As
a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g.
installation of protective circuitry or redundancy) that no injury or damage is sustained by third
parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
10