Total Power MKW50-12S12 Smallest encapsulated 50w converter Datasheet

FEATURES
► Smallest Encapsulated 50W Converter!
► Package Size 2.0”x 1.0”x 0.4”
► Wide 2:1 lnput Range
► Excellent Efficiency up to 92%
► Over-Temperature Protection
► I/O-isolation Voltage 1500VDC
► Remote On/Off Control
► Shielded Metal Case with Isolated Baseplate
► Heatsink (Optional)
►CSA/UL/IEC/EN 60950-1 (Approval pending)
► 3 Years Product Warranty
PRODUCT OVERVIEW
The MKW50 series is the latest generation of high performance dc-dc converter modules setting a new standard concerning power density. The product
offers fully 50W in an encapsulated, shielded metal package with dimensions of just 2.0”x1.0”x0.4”.All models provide wide 2:1 input voltage range and
precisely regulated output voltages.
Advanced circuit topology provides a very high efficiency up to 92% which allows an operating temperature range of -40°C to +80°C . Further features
include remote On/Off, trimmable output voltage, under-voltage shutdown as well as overload and over-temperature protection.
Typical applications for these converters are battery operated equipment, instrumentation, distributed power architectures in communication and industrial
electronics and many other space critical applications.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
(Range)
VDC
MKW50-12S033
MKW50-12S05
MKW50-12S12
MKW50-12S15
MKW50-12S24
MKW50-24S033
MKW50-24S05
MKW50-24S12
MKW50-24S15
MKW50-24S24
MKW50-48S033
MKW50-48S05
MKW50-48S12
MKW50-48S15
MKW50-48S24
12
( 9 ~ 18 )
24
( 18 ~ 36 )
48
( 36 ~ 75 )
VDC
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
Output Current
Input Current
Reflected
Over
Max. capacitive
Ripple
Voltage
Load
Max.
@Max. Load
@No Load
Current
Protection
mA
10000
10000
4170
3330
2080
10000
10000
4170
3330
2080
10000
10000
4170
3330
2080
mA(typ.)
3090
4630
4580
4580
4570
1550
2260
2260
2260
2290
770
1130
1130
1130
1150
mA(typ.)
85
110
160
160
250
50
70
85
85
110
35
45
50
50
60
mA(typ.)
VDC
3.9
6.2
15
18
30
3.9
6.2
15
18
30
3.9
6.2
15
18
30
50
40
30
Efficiency
(typ.)
@Max. Load
μF
25800
17000
2900
1900
750
25800
17000
2900
1900
750
25800
17000
2900
1900
750
%
89
90
91
91
91
89
92
92
92
91
89
92
92
92
91
Input Specifications
Parameter
Input Surge Voltage (100ms. max)
Start-Up Threshold Voltage
Under Voltage Lockout
Input Polarity Protection
Start Up Time
Power Up
Remote On/Off
Internal Filter Type
Short Circuit Current
In
Total Power International,
Inc
Model
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
12V Input Models
24V Input Models
48V Input Models
Min.
Typ.
Max.
Unit
-0.7
--25
-0.7
--50
-0.7
--100
----9
VDC
----18
----36
--8.3
----16.5
----33
--None
----30
ms
Nominal Vin and Constant Resistive Load
----30
ms
All Models
LC Filter (for EN55022,Class A compliance see note 7)
--- (Hiccup Mode 1.5 Hz typ, 24V Output Model:0.3 Hz typ.)
Toll Free: 877-646-0900
www.total-power.com
MKW50 SERIES
Total Power International, Inc.
Tota
DC/DC CONVERTER 50W, Highest Power Density
Output Specifications
Parameter
Output Voltage Setting Accuracy
Line Regulation
Load Regulation
Minimum Load
Ripple & Noise (20MHz bandwith)
Transient Recovery Time
Temperature Coefficient
Over Load Protection
Short Circuit Protection
Over Voltage Protection
Conditions
At 50% Load and Nominal Vin
Vin=Min. to Max. @ Full Load
Min. Load to Full Load
Min.
Typ.
------------No minimum Load Requirement
3.3V & 5V Models(3)
--100
--150
12V, 15V & 24V Models(3)
25% Load Step Change(2)
--250
----Current Limitation at 150% typ. of Iout max., Hiccup
Hiccup Automatic Recovery
For Shutdown Voltage see Model Selection Guide
Max.
±1.0
±0.5
±0.5
Unit
%Vnom.
%
%
------±0.02
mV P-P
mV P-P
μsec
%/℃
Conditions
Min.
Typ.
Max.
60 Seconds
1500
----500 VDC
1000
----100KHz, 1V
----2200
--285
--24Vo Models
Other Models
--320
--MIL-HDBK-217F@25℃, Ground Benign
227,100
----UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)
Unit
VDC
MΩ
pF
KHz
KHz
Hours
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF(calculated)
Safety Approvals(pending)
Input Fuse
12V Input Models
10000mA Slow-Blow Type
24V Input Models
5000mA Slow-Blow Type
48V Input Models
2500mA Slow-Blow Type
Remote On/Off Control
Parameter
Converter On
Converter Off
Control Input Current (on)
Control Input Current (off)
Control Common
Standby Input Current
Conditions
Vctrl = 5.0V
Vctrl = 0V
Nominal Vin
Min.
Typ.
3.5V ~ 12V or Open Circuit
0V ~ 1.2V or Short Circuit
--0.5
---0.5
Referenced to Negative Input
--2.5
Max.
Unit
-----
mA
mA
---
mA
Max.
-----
Unit
%
%
Output Voltage Trim
Parameter
Trim Up / Down Range(9)
Conditions
% of Nominal Output Voltage (24Vo Models)
% of Nominal Output Voltage (Other Models)
Min.
+20 / -10
±10
Typ.
-----
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(Natural Convection, see Derating)
Thermal Impedance
Case Temperature
Thermal Protection
Storage Temperature Range
Humidity (non condensing)
RFI
Lead Temperature (1.5mm from case for 10Sec.)
In
Total Power International,
Inc
Model
Min.
MKW50-XXS033
MKW50-24S05, MKW50-24S12
MKW50-24S15, MKW50-48S05
MKW50-48S12, MKW50-48S15
MKW50-12S12, MKW50-12S15
MKW50-12S24, MKW50-24S24
MKW50-48S24
MKW50-12S05
Natural Convection without Heatsink
Natural Convection with Heatsink
100LFM Convection without Heatsink
100LFM Convection with Heatsink
200LFM Convection without Heatsink
200LFM Convection with Heatsink
400LFM Convection without Heatsink
400LFM Convection with Heatsink
Max.
without Heatsink with Heatsink
56
64
53
62
℃
-40
46
56
38
12.1
9.8
9.2
5.4
7.8
4.5
5.2
3.0
---
Shutdown Temperature
-50
--Six-Sided Shielded, Metal Case
---
Toll Free: 877-646-0900
Unit
49
℃/W
℃/W
℃/W
℃/W
℃/W
℃/W
℃/W
℃/W
℃
----------------+105
110℃ typ.
+125
95
℃
% rel. H
260
℃
www.total-power.com
MKW50 SERIES
Tota
Total Power International, Inc.
DC/DC CONVERTER 50W, Highest Power Density
EMC Specifications
Parameter
EMI
ESD
Radiated immunity
Fast transient (see Note 8)
Surge (see Note 8)
Conducted immunity
Standards & Level
EN55022
EN61000-4-2 air ± 8KV , Contact ± 6KV
EN61000-4-3 10V/m
EN61000-4-4 ±2KV
EN61000-4-5 ±1KV
EN61000-4-6 10V/m
Performance
Class A (see Note 7)
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Power Derating Curve
MKW50-12S033, MKW50-24S033, MKW50-48S033
MKW50-12S033, MKW50-24S033, MKW50-48S033
Derating Curve without Heatsink
Derating Curve with Heatsink
MKW50-24S05, MKW50-24S12, MKW50-24S15, MKW50-48S05,
MKW50-24S05, MKW50-24S12, MKW50-24S15, MKW50-48S05,
MKW50-48S12, MKW50-48S15 Derating Curve without Heatsink
MKW50-48S12, MKW50-48S15 Derating Curve with Heatsink
MKW50-12S12, MKW50-12S15, MKW50-12S24, MKW50-24S24,
MKW50-12S12, MKW50-12S15, MKW50-12S24, MKW50-24S24,
MKW50-48S24 Derating Curve without Heatsink
MKW50-48S24 Derating Curve with Heatsink
MKW50-12S05 Derating Curve without Heatsink
MKW50-12S05 Derating Curve with Heatsink
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
MKW50 SERIES
Tota
Total Power International, Inc.
DC/DC CONVERTER 50W, Highest Power Density
95
95
90
90
85
85
Efficiency(%)
Efficiency(%)
Efficiency Curve @25℃
80
75
70
12V
10
20
30
40
50
60
70
80
90
9V
12V
65
18V
60
75
70
9V
65
80
18V
60
100
10
20
30
% of Full Load
90
85
85
Efficiency(%)
Efficiency(%)
95
90
80
75
70
60
40
50
60
70
80
90
12V
65
18V
60
100
12V
18V
20
30
85
Efficiency(%)
Efficiency(%)
90
85
80
75
70
12V
70
80
90
100
18V
24V
36V
10
20
30
85
85
Efficiency(%)
Efficiency(%)
90
80
75
70
18V
24V
65
36V
60
60
70
80
90
100
70
80
90
80
75
70
18V
24V
65
36V
60
100
% of Full Load
10
20
30
40
50
60
70
80
90
100
% of Full Load
MKW50-24S05 Efficiency vs Load Current
In
Total Power International,
Inc
50
MKW50-24S033 Efficiency vs Load Current
95
60
40
% of Full Load
90
50
100
60
95
40
90
75
MKW50-12S24 Efficiency vs Load Current
30
80
80
% of Full Load
20
70
65
18V
60
10
60
70
9V
65
60
50
MKW50-12S15 Efficiency vs Load Current
95
50
40
% of Full Load
90
40
100
9V
10
95
30
90
75
MKW50-12S12 Efficiency vs Load Current
20
80
80
% of Full Load
10
70
70
9V
65
30
60
MKW50-12S05 Efficiency vs Load Current
95
20
50
% of Full Load
MKW50-12S033 Efficiency vs Load Current
10
40
Toll Free: 877-646-0900
MKW50-24S12 Efficiency vs Load Current
www.total-power.com
MKW50 SERIES
Tota
Total Power International, Inc.
DC/DC CONVERTER 50W, Highest Power Density
Efficiency Curve @25℃
100
95
95
90
Efficiency(%)
Efficiency(%)
90
85
80
75
70
18V
65
24V
10
20
30
40
50
60
70
80
90
80
75
70
18V
24V
65
36V
60
85
36V
60
100
10
20
30
% of Full Load
90
85
85
Efficiency(%)
Efficiency(%)
95
90
80
75
70
48V
65
60
50
60
70
80
90
36V
48V
75V
60
100
10
20
30
90
85
85
Efficiency(%)
Efficiency(%)
90
80
75
70
36V
48V
65
75V
60
50
60
50
60
70
80
90
100
MKW50-48S05 Efficiency vs Load Current
95
40
40
% of Full Load
95
30
100
75
MKW50-48S033 Efficiency vs Load Current
20
90
80
% of Full Load
10
80
65
75V
40
70
70
36V
30
60
MKW50-24S24 Efficiency vs Load Current
95
20
50
% of Full Load
MKW50-24S15 Efficiency vs Load Current
10
40
70
80
90
80
75
70
36V
48V
65
75V
60
100
10
% of Full Load
20
30
40
50
60
70
80
90
100
% of Full Load
MKW50-48S12 Efficiency vs Load Current
MKW50-48S15 Efficiency vs Load Current
95
Efficiency(%)
90
85
80
75
70
36V
48V
65
75V
60
10
20
30
40
50
60
70
80
90
100
% of Full Load
MKW50-48S24 Efficiency vs Load Current
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
MKW50 SERIES
DC/DC CONVERTER 50W, Highest Power Density
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
3
Ripple & Noise measurement bandwidth is 0-20MHz, measured with a 1μF MLCC and a 10μF Tantalum Capatitor.
4
All DC/DC converters should be externally fused at the front end for protection.
5
Other input and output voltage may be available, please contact factory.
6
To order the converter with heatsink, please add a suffix -HS (e.g. MKW50-12S05-HS) to order code.
7
The MKW50 series can meet EN55022 Class A with parallel an external capacitor to the input pins. (12Vin: 22μF/25V 1210 MLCC, 24Vin: 3.3μF/50V 1210 MLCC,
8
48Vin: 2.2μF/100V 1210 MLCC.
The MKW50 series can meet EN61000-4-4 & EN61000-4-5 by adding a capacitor across the input pins.Suggested capacitor: CHEMI-CON KY 330μF/100V.
9
Do not exceed maximum power specification when adjusting output voltage.
10
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
11
Specifications are subject to change without notice.
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
MKW50 SERIES
DC/DC CONVERTER 50W, Highest Power Density
Package Specifications
Mechanical Dimensions
Pin Connections
1.00 [ 0.04]
1
2
3.6 [0.14]
Bottom View
50.8 [2.00]
3
45.72 [1.80]
10.16
[0.40]
5.08
[0.20]
Pin
Function
1
+Vin
2
-Vin
3
Remote On/Off
4
+Vout
5
-Vout
6
Trim
1.1 [0.04]
5
6
10.16
[0.40]
4
10.16
[0.40]
►All
dimensions in mm (inches)
►Tolerance: X.X±0.25
2.54
[0.10]
5.5
[0.22]
11.0
[0.43]
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
25.4 [1.00]
►Pin
diameter  1.0 ±0.05 (0.04±0.002)
Physical Characteristics
Case Size
:
50.8x25.4x11mm (2.0x1.0x0.43 inches)
Case Material
:
Aluminium Alloy, Black Anodized Coating
Base Material
:
FR4 PCB (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Potting Material
:
Epoxy (UL94-V0)
Weight
:
30g
Heatsink (Option –HS)
31.1 [1.22]
Physical Characteristics
Heatsink Material
:
Aluminum
Finish
:
Black Anodized Coating
Weight
:
9g
18.0 [0.71]Max
31.0 [1.22]Max
Heat-sink
►The advantages of adding a heatsink are:
Thermal pad
1. To help heat dissipation and increase the stability and
Clamp
reliability of DC/DC converters at high operating
Converter
temperature atmosphere.
2. To upgrade the operating temperature of DC/DC converters,
please refer to Derating Curve.
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
MKW50 SERIES
DC/DC CONVERTER 50W, Highest Power Density
External Output Trimming
Output can be externally trimmed by using the method shown below
MKW50 Module
Bottom View
MKW50 Module
Bottom View
MKW50-XXS033 Trim Table
Trim down
1
2
Vout=
Vox0.99
Vox0.98
Rd=
63.59
30.28
Trim up
Vout=
Ru=
1
Vox1.01
70.50
MKW50-XXS05 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
45.53
Trim up
Vout=
Ru=
1
Vox1.01
36.57
MKW50-XXS12 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
394.50
Trim up
Vout=
Ru=
1
Vox1.01
368.92
MKW50-XXS15 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
572.67
Trim up
Vout=
Ru=
1
Vox1.01
392.98
MKW50-XXS24 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
318.05
Trim up
Vout=
Ru=
2
Vox1.02
247.2
3
Vox0.97
18.19
4
Vox0.96
11.95
5
Vox0.95
8.13
6
Vox0.94
5.56
7
Vox0.93
3.70
8
Vox0.92
2.31
9
Vox0.91
1.21
10
Vox0.90
0.34
%
Volts
KOhms
2
Vox1.02
29.28
3
Vox1.03
16.87
4
Vox1.04
10.90
5
Vox1.05
7.38
6
Vox1.06
5.06
7
Vox1.07
3.42
8
Vox1.08
2.20
9
Vox1.09
1.25
10
Vox1.10
0.49
%
Volts
KOhms
2
Vox0.98
20.61
3
Vox0.97
12.31
4
Vox0.96
8.15
5
Vox0.95
5.66
6
Vox0.94
4.00
7
Vox0.93
2.81
8
Vox0.92
1.92
9
Vox0.91
1.23
10
Vox0.90
0.68
%
Volts
KOhms
2
Vox1.02
16.58
3
Vox1.03
9.92
4
Vox1.04
6.59
5
Vox1.05
4.59
6
Vox1.06
3.25
7
Vox1.07
2.30
8
Vox1.08
1.59
9
Vox1.09
1.03
10
Vox1.10
0.59
%
Volts
KOhms
2
Vox0.98
179.74
3
Vox0.97
106.08
4
Vox0.96
68.86
5
Vox0.95
46.39
6
Vox0.94
31.36
7
Vox0.93
20.60
8
Vox0.92
12.51
9
Vox0.91
6.21
10
Vox0.90
1.17
%
Volts
KOhms
2
Vox1.02
161.92
3
Vox1.03
94.97
4
Vox1.04
61.86
5
Vox1.05
42.12
6
Vox1.06
29.00
7
Vox1.07
19.66
8
Vox1.08
12.66
9
Vox1.09
7.23
10
Vox1.10
2.89
%
Volts
KOhms
2
Vox0.98
248.63
3
Vox0.97
145.60
4
Vox0.96
94.97
5
Vox0.95
64.87
6
Vox0.94
44.92
7
Vox0.93
30.72
8
Vox0.92
20.10
9
Vox0.91
11.86
10
Vox0.90
5.28
%
Volts
KOhms
2
Vox1.02
182.12
3
Vox1.03
108.73
4
Vox1.04
71.43
5
Vox1.05
48.85
6
Vox1.06
33.71
7
Vox1.07
22.86
8
Vox1.08
14.69
9
Vox1.09
8.33
10
Vox1.10
3.23
%
Volts
KOhms
2
Vox0.98
146.05
3
Vox0.97
85.8
4
Vox0.96
55.51
5
Vox0.95
37.415
6
Vox0.94
25.625
7
Vox0.93
16.515
8
Vox0.92
9.81
9
Vox0.91
4.9785
10
Vox0.90
0.9185
%
Volts
KOhms
4
Vox1.04
109.255
6
Vox1.06
63.38
8
Vox1.08
39.025
10
Vox1.1
27.52
12
Vox1.12
18.39
14
Vox1.14
11.77
16
Vox1.16
7.29
18
Vox1.18
3.308
20
Vox1.20
0.3658
%
Volts
KOhms
In
Total Power International,
Inc
Toll Free: 877-646-0900
www.total-power.com
Tota
Total Power International, Inc.
MKW50 SERIES
DC/DC CONVERTER 50W, Highest Power Density
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
Current
Probe
Cin
+Out
DC / DC
Converter
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a 1μF ceramic capacitor and a 10μF tantalum capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz.
Position the load between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Resistive
Load
Scope
Copper Strip
Technical Notes
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic
low is 0V to 1.2V. A logic high is 3.5V to 12V. The maximum sink current at the on/off terminal (Pin 3) during a logic low is -100μA.
Overcurrent Protection
To provide hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure overload for an
unlimited duration.
Overvoltage Protection
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals.
The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output
overvoltage. The OVP level can be found in the output data.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0
Ω at 100 KHz) capacitor of a 33μF for the 12V input devices and a 10μF for the 24V and 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 4.7μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
Cout
Load
-Out
Maximum Capacitive Load
The MKW50 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
50mm / 2in
15mm / 0.6in
In
Total Power International,
Inc
Air Flow
DUT
Toll Free: 877-646-0900
www.total-power.com
Similar pages