EAGLE SIGNAL brand HP5 CYCL-FLEX® Reset Timer Electric Timers The high quality timer that has become an industry standard... knob setpoint, cycle progress pointer, pilot light, and patented plug-in housing Also see Series HP5E in Section 5 for SolidState Model RECOGNIZED 6 The HP5 CYCL-FLEX® series timer is a high quality, synchronous motor driven reset timer housed in the standard CYCL-FLEX® plug-in housing. Dial Minimum Setting APPROVED Dial Divisions Repeat Accuracy 18 15 Min. 5 30 Min. 30 Sec. 15 Sec. ±4.5 Sec. 1 Min. 1/2 Min. ■ Easily read and well-spaced calibrations 6 ±9 Sec. 60 Min. 2 Min. 1 Min. ±18 Sec. ■ Red progress pointer displays remaining time interval ■ Pilot light indicates when timer motor is energized 7 150 Min. 4.5 Min. 2 Min. ±45 Sec. 8 5 Hr. 9 Min. 3 Min. ±1.5 Min. ■ Standard timers supplied with "power on" clutch operation 9 10 Hr. 20 Min. 10 Min. ±3 Min. ■ Optional reverse action clutch will not reset on power failure 10 30 Hr. 1 Hr. 1/2 Hr. ±9 Min. ■ 15 terminal ABS (UL rated 94V-0) molded housing has high impact 11 60 Hr. 2 Hr. 1 Hr. ±18 Min. ■ Knob adjustable time ranges - progress pointer for each T I M E R S CERTIFIED Time Ranges Cont.: Sym. ■ 16 standard time ranges from 5 seconds to 60 hours E L E C T R I C FM ® ® ■ Highly visible, calibrated dials (7.85 inch circumference) resistance and will not support combustion Reset Time: 1/2 second at max. setting OPERATION Voltage/Frequency: 120V (+10, -15%), 60 Hz 240V (+10, -15%), 60 Hz Application of power to terminals 1, 2, and 11 energizes the clutch coil, closes contacts 9-10 and 6-8, and starts the timing period. At time out, contacts 4-3 close, 11-12 open, and the motor stops. The timer will remain in this condition until power is removed from the clutch coil. Contacts 6-7-8 and 9-10-C are instantaneous contacts and operate with the application of power to the clutch coil. Contacts 3-4-5 and 11-12-A operate at time out with contacts 3-4-5 operating prior to contacts 11-12-A. Burden: Motor: 2.45 VA, 120 VAC Clutch: 10.5 VA Output Rating: 10 amps, resistive, 120 VAC 5 amps, resistive, 240 VAC Electrical Lifetime: Contingent on load characteristics. Average contact life at full load is 250,000 operations. At 1 amp load, switch life increases to 5 million cycles. Inrush current should not exceed 10 amps. Power On Response: 28 ms average pull-in 17 ms average drop-out Temperature Range: 0˚ to 140˚F (-18˚ to +60˚C) SPECIFICATIONS Time Ranges: Sym. Dial Minimum Setting Dial Divisions Repeat Accuracy 17 5 Sec. 1/6 Sec. .05 Sec. ±.05 Sec. 15 10 Sec. 1/3 Sec. 1/6 Sec. ±.05 Sec. 14 15 Sec. 1/2 Sec. 1/4 Sec. ±.08 Sec. 0 30 Sec. 1 Sec. 1/2 Sec. ±.15 Sec. 1 60 Sec. 2 Sec. 1 Sec. ±.3 Sec. 2 150 Sec. 4.5 Sec. 2 Sec. ±.75 Sec. 3 5 Min. 9 Sec. 3 Sec. ±1.5 Sec. 4 10 Min. 20 Sec. 10 Sec. ±3 Sec. 6.08 DANAHER SENSORS & CONTROLS Vibration: Unaffected by 2.5G sinusoidal vibration magnitudes in both directions of three perpendicular mounting axes imposed from 10 to 900 Hz Approximate Weight: 2 lb. 14 oz. Agency Approvals: UL Recognition E61735 UL Recognition 71726 (Feature 92 only) CSA Certification LR26861 CSA Certification (Feature 92 only) FM Approval 15030 RoHS OPERATION ENCLOSURES Standard and Reverse Start Instantaneous contacts 9-10-C and 6-7-8 operate directly with the clutch offering different sequences of operation depending on the control circuit configuration. Delayed contacts 4-3 and 11-A close and contacts 4-5 and 11-12 open when timer reaches a timed out condition. Contacts 4-5 and 11-12 close and contacts 4-3 and 11-A open when timer is reset. Schematic Diagram 1 Model No. NEMA Class HN308 HN364 HN368 1 1 !A HN370 1A Description Surface Mtg. with terminal block Surface Mtg. without terminal block Dual unit cabinet with 9 position terminal block, timer housings, and DPST toggle switch Dual unit cabinet less unit cases and toggle switch, with 9 terminal block 2 ACCESSORIES M Model No. A 11 H-5331 HP50-31 HP50-103 10 12 9 3 C 4 8 6 HP50-131 HP50-133 HP50-295 5 7 Description Mounting Brackets 2 req'd per timer One Hole Mounting Ring 120 VAC, 50/60 Hz Repeat Cycle Kit Not applicable with Feature 19 CYCL-FLEX® Water-Sealed Housing Surface Mounting Adapter to use in place of brackets Dial Lock MOUNTING DRILL AND TAP FOUR HOLES FOR 8-32 SCREWS (INCLUDED W/UNIT) 3.187 + .062 (80.95 + 1.57) DIA. CUTOUT 1.406 (35.71) 4.250 (107.95) 3.062 (77.77) 1.406 (35.71) 1.406 (35.71) MTG. HOLE USED FOR GROUNDING CASE 1.406 (35.71) 3.812 (96.82) 4.125 (104.78) 1.625 (41.27) 5.750 (146.05) ORDERING INFORMATION HP5 15 A6 TIME RANGE Sym. 01 FEATURES Description Sym. Description 17 0-5 Sec. 18 0-15 Min. 15 0-10 Sec. 5 0-30 Min. 14 0-15 Sec. 6 0-60 Min. 0 0-30 Sec. 7 0-150 Min. 1 0-60 Sec. 8 2 0-150 Sec. 3 4 Sym. VOLTAGE & FREQUENCY Sym. Description 0-5 Hr. A6 120V, 60 Hz 9 0-10 Hr. B6 240V, 60 Hz 0-5 Min. 10 0-30 Hr. 0-10 Min. 11 0-60 Hr. Description 01 Reverse Clutch Arrangement 07 Dial Lock 19 Revision for Mtg. to HN383 Explosion Proof Cabinet. Add when purchased without cabinet. DOES NOT have pilot light. 22 Water Resistant Window & Housing 92* Enclosed in HN383 Explosion Proof Cabinet *Laboratory Testing: UL Recognition E61735 CSA Certification LR45132-1 DANAHER SENSORS & CONTROLS 6.09 6 T OE TL AE LC IT R ZI IC N G T I M E R S