MTWA11 SERIES 10W Wall Mount Power Supply for I.T. Equipment – – – – – – – 1 Year Warranty Wide Input Voltage 90 to 264 VAC, 47 to 63Hz European type 2 prong plug Output Voltage Available From 5VDC Thru 48VDC Optional Output Connector (See appendix) Single Output Class II Insulation CEC Level V, Energy Star 2.0, and RoHS Compliance Approvals: Single Output Product Number Output Voltage Max. Output Current MTWA11-S02 5 ~ 6 VDC 1.60 ~ 1.33 A MTWA11-S03 6 ~ 8 VDC 1.33 ~ 1.00 A MTWA11-S04 8 ~ 11 VDC 1.25 ~ 0.91 A MTWA11-S05 11 ~ 13 VDC 0.91 ~ 0.77 A MTWA11-S06 13 ~ 16 VDC 0.77 ~ 0.63 A MTWA11-S07 16 ~ 21 VDC 0.63 ~ 0.48 A MTWA11-S08 21 ~ 27 VDC 0.48 ~ 0.37 A MTWA11-S09 27 ~ 33 VDC 0.37 ~ 0.30 A MTWA11-S10 33 ~ 40 VDC 0.30 ~ 0.25 A MTWA11-S11 40 ~ 48 VDC 0.25 ~ 0.20 A The total regulation on model S02-S05 is required to use AWG#20/4FT output cable. The total regulation on model S06-S10 is required to use AWG#24/4FT output cable. The regulation and efficiency will be changed by modified output cable. Total Regulation Maximum Output Power 5% 5% 5% 5% 5% 3% 3% 3% 3% 3% 8W 8W 10W 10W 10W 10W 10W 10W 10W 10W Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) Low Line Inrush Current High Line Inrush Current Efficiency Line Regulation Load Regulation Over Voltage Protection Over Current Protection Transient Response Hold-Up Time Start Up Time * Ripple & Noise (Peak to Peak) Safety Ground Leakage Current No-Load Power Consumption Temperature Coefficient Test Conditions Operating Voltage Vin=90 to 264VAC Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, 25°C, Cool start, Vin=115VAC Io=Full load, 25°C, Cool start, Vin=230VAC Io=Full Load, Vin=230VAC Io=Full Load Vin=230VAC Nil But, Output protected to short circuit conditions Io=Full Load to Half Load, Vin=100VAC Io=Full Load, Vin=110VAC Io=Full Load, Vin=100VAC Full Load, Vin=90VAC Io=Full Load, Vin=240VAC No load,Vin=240VAC All output Min. Typ. 90 47 0 71 35 70 76 0.5 3 Nil Max. Unit 264 63 10 0.3 0.2 40 80 85 1 5 VAC Hz W A A A A % % % % % mS mS S % mA W %/°C 4 5 -0.04 10 2 0.5 0.2 0.2 3 1 0.25 0.3 0.04 Conditions Parameter Test Conditions Operating Temperature Storage Temperature Relative Humidity No-Condensing Operating Temperature at 25°C, Calculated per MIL-HDBK-217F De-rate linearly from 100% load at 40°C to 50% load at 70°C Min. Typ. Max. Unit 0 -40 5 0.1 40 70 85 95 °C °C % M Hrs Min. Unit 4242 B B VDC CLASS CLASS Approvals and Compliance Parameter Dielectric Withstanding Voltage for Primary to secondary EMI requirements for CISPR-22 EMI requirements for FCC PART-15 Test Conditions Primary to secondary Vin=220VAC Vin=110VAC Mechanical and PIN out Note: 1. Dimensions are shown in mm. 2. Weight: 90g approx. 3. Optional output connector.