Electrical Specifications
Key Features:
• 100W Output Power
• Selectable 88-264 AC Input
• EN60950 Approved
• Wide Temp Operation
• Seven Single Output Models
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
• Meets EN55022
Inrush Current
• >300 kHour MTBF
Safety Ground Leakage Current
• Compact Metal Enclosure
Hold-Up Time
Set-Up Time
Rise Time
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Max.
132
264
370
63
Units
0.7
1.0
mA
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
115 VAC
15
230 VAC
20
230 VAC
1,000
230 VAC
30
±0.02
Continuous (Autorecovery)
See Note 3 115
See Note 4 135
Max.
Units
VAC
VDC
Hz
A Pk
mSec
mSec
mSec
%/°C
135
165
%
%
Max.
Units
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
MicroPower Direct
EMC Compliance
292 Page Street
Suite D
Stoughton, MA 02072
USA
Switching Frequency
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
Typ.
88
115
Switch Selectable
176
220
248
47
See Model Selection Guide
Cold Start, 115 VAC
30.0
Cold Start, 230 VAC
60.0
115 VAC
240 VAC
Output
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
RoHS Compliant
Conditions
Conditions
Input to Output
Input to Ground
Output to Ground
500 VDC
Conducted
Electrostatic Discharge (ESD)
RF Field Susceptibility
Electrical Fast Transients/Bursts On Mains
Surge
Min.
3,000
1,500
500
Typ.
VAC
100
MΩ
EN 55022; EN 61000-3-2, -3
IEC/EN 61000-4-2, -6, -8, -11
IEC/EN61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
75
kHz
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-10
+25
-20
Free Air Convection
RH, Non-condensing
Ambient
Max.
+60
+85
Units
°C
°C
95
%
Physical
Case Size
Case Material
Weight
7.83 x 3.86 x 1.50 Inches (199.0 x 98.0 x 38.0 mm)
Vented Metal Enclosure
22.9 Oz (0.65 kg)
Reliability Specifications
Parameter
MTBF
Safety Standards
Vibration
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
300
kHours
CAN/CSA-C22.2 No 60950-1-03, ANSI/UL Std No 60950-1, IEC 60950
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Model Selection Guide
Input
Current (A)
Model
Number
MPE-100FS-05
MPE-100FS-7.5
MPE-100FS-12
MPE-100FSS-15
MPE-100FS-24
MPE-100FS-27
MPE-100FS-48
115 VAC
230 VAC
3.15
3.15
3.15
3.15
3.15
3.15
3.15
1.5
1.5
1.5
1.5
1.5
1.5
1.5
Notes:
1. Output voltage tolerance includes the
the effects of set point accuracy, line
regulation and load regulation.
2. Ripple and noise is measured at 20 MHz
bandwidth using a 12 inch twisted pair
wire to connect to the power supply
terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close
to the power supply terminals as possible.
3. Overvoltage protection is provided
by a “hiccup mode” circuit. The unit
recovers automatically when the fault
condition is removed.
4. The overload protection circuit shuts
down the output. The unit recovers
automatically when the fault condition
is removed.
5. It is recommended that a fuse be used
on the input of a power supply for
protection. For the MPE-100FS series,
a 7.5A/250 VAC slow blow should be
used.
Output
Voltage (VDC)
Rated
5.0
7.5
12.0
15.0
24.0
27.0
48.0
Adjust
Current (A)
Rated
4.5 - 5.5
6.75 - 8.25
10.8 - 13.2
13.5 - 16.5
21.6 - 26.4
24.3 - 29.7
43.2 - 52.8
20.0
13.5
8.5
6.7
4.5
3.5
2.2
Range
Output
Tolerance
(%)
0 to 20.0
0 to 13.5
0 to 8.5
0 to 6.7
0 to 4.5
0 to 3.5
0 to 2.2
Ripple &
Noise
Efficiency
(%, Typ)
(mV p-p)
±2.0
±1.0
±1.0
±1.0
±1.0
±1.0
±1.0
100
125
125
125
150
150
150
76
78
80
81
83
83
84
Mechanical Dimensions
Pin Connections
Pin
Function
1
2
3
4
5
6
7
AC-Line
AC-Neutral
AC-Ground
-Vout
-Vout
+Vout
+Vout
Derating Curve
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Static Characteristics
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages