AZETTLER AZ2310-1A-5D 30 amp miniature power relay Datasheet

AZ2310
30 AMP MINIATURE
POWER RELAY
FEATURES
•
•
•
•
•
•
Low cost
30 Amp switching
144 Amp inrush current
Quick connect terminals
Creepage distance more than 8 mm
UL, CUR file E44211
CONTACTS
Arrangement
SPST N.O. (1 Form A)
Ratings
Resistive load:
Max. switched power: 7500 VA
Max. switched current: 30 A
Max. switched voltage: 250 VAC
Rated Load
UL, CUR
30 A at 250 VAC Res.
2 HP 125/250 VAC
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 107
1 x 105 at 30 A 240 VAC Res.
Operate Time (typical)
20 ms at nominal coil voltage
Release Time (typical)
5 ms at nominal coil voltage
(with no coil suppression)
Dielectric Strength
(at sea level for 1min)
4000 Vrms coil to contact
1200 Vrms between open contacts
Insulation
Resistance
1000 megohms min. at 20°C, 500 VDC,
50% RH
Dropout
Greater than 10% of nominal coil volt age
Ambient Temperature
Operating
Storage
At nominal coil voltage
-40°C (-40°F) to 70°C (158°F)
-40°C (-40°F) to 105°C (221°F)
Vibration
0.04" DA at 10–55 Hz
TV-15 at 120 VAC
Material
Silver tin oxide
Resistance
< 30 milliohms initially
(24 V, 1 A voltage drop method)
COIL
Power
At Pickup Voltage
(typical)
588 mW
Max. Continuous
Dissipation
2.0 W at 20°C (68°F) ambient
Temperature Rise
30°C (54°F) at nominal coil voltage
Temperature
Shock
Max. 105°C (221°F)
Operating
10 g, 11 ms, 1/2 sine (no false operation)
Non-Operating 100 g, 11 ms, 1/2 sine (no damage)
Enclosure
P.B.T. polyester
Terminals
Tinned copper alloy
P. C. & quick connect
Note: Allow suitable slack on leads when wiring, and
do not subject the terminals to excessive force.
NOTES
Weight
55 grams
1. All values at 20°C (68°F).
2. Relay may pull in with less than “Must Operate” value.
3. Specifications subject to change without notice.
11/30/05W
AZ2310
RELAY ORDERING DATA
COIL SPECIFICATIONS
Nominal Coil
VDC
3
Must Operate
VDC
2.1
Max. Continuous
VDC
3.9
ORDER NUMBER
Coil Resistance
± 10%
7.5
Form A
(SPST N.O.)
AZ2310–1A–3D
6.3
20
AZ2310–1A–5D
5
3.5
6
4.2
7.7
30
AZ2310–1A–6D
9
6.3
11.6
67
AZ2310–1A–9D
12
8.4
15.5
120
AZ2310–1A–12D
24
16.8
31.0
480
AZ2310–1A–24D
48
33.6
62.0
1920
AZ2310–1A–48D
60
42.2
77.5
3000
AZ2310–1A–60D
MECHANICAL DATA
NO
MOUNTING HOLE LAYOUT
.177
[4.5]
1.291
[32.8]
COM
.866
[22.0]
2 x ø.177
[ø4.5]
1.713
[43.5]
1.713
[43.5]
1.988
[50.5]
2 x .250
[6.3]
2 x .187
[4.7]
2 x .354
[9.0]
WIRING DIAGRAM
NO
1.409
[35.8]
4 x .032
[0.8]
.965
[24.5]
.098
[2.5]
COM
2 x .295
[7.5]
Viewed toward terminals
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
11/30/05W
Similar pages