Series AM30EW-Z 30 Watt | DC-DC Converter FEATURES: • • • • Ultra Wide 4:1 input range Efficiency up to 91% Soft start Continuous short circuit protection • • • • Remote on/off control Input/Output Isolation 1600VDC Operating temperature -40ºC to + 75ºC RoHS compliant Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) 9-36 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 18-75 3.3 5 5.1 12 15 3.3 5 5.1 12 15 7.5 6 6 2.5 2 7.5 6 6 2.5 2 Input Voltage (V) Output Voltage (V) Output Current max (A) 9-36 9-36 9-36 18-75 18-75 18-75 ±5 ±12 ±15 ±5 ±12 ±15 ±3 ±1.25 ±1 ±3 ±1.25 ±1 AM30EW-2403SZ AM30EW-2405SZ AM30EW-2405.1SZ AM30EW-2412SZ AM30EW-2415SZ AM30EW-4803SZ AM30EW-4805SZ AM30EW-4805.1SZ AM30EW-4812SZ AM30EW-4815SZ Models Dual output Model AM30EW-2405DZ AM30EW-2412DZ AM30EW-2415DZ AM30EW-4805DZ AM30EW-4812DZ AM30EW-4815DZ Models Triple output Maximum Capacitive Load (uF) Efficiency (%) 20000 14000 14000 2000 2000 20000 14000 14000 2000 2000 86 88 88 89 89 86 88 88 90 91 Maximum Capacitive Load (uF) Efficiency (%) ±3000 ±1300 ±1300 ±3000 ±1300 ±1300 88 87 87 88 88 88 Model Input Voltage (V) Output Voltage (V) Output Auxiliary Voltage (V) Output Current max (A) Maximum Capacitive Load (uF) Efficiency (%) AM30EW-240312TZ AM30EW-240315TZ AM30EW-240512TZ AM30EW-240515TZ AM30EW-480312TZ AM30EW-480315TZ AM30EW-480512TZ AM30EW-480515TZ 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 3.3 3.3 5 5 3.3 3.3 5 5 ±12 ±15 ±12 ±15 ±12 ±15 ±12 ±15 5 / ±0.42 5 / ±0.33 4 / ±0.42 4 / ±0.33 5 / ±0.42 5 / ±0.33 4 / ±0.42 4 / ±0.33 15000 / ±220 15000 / ±220 8000 / ±220 8000 / ±220 15000 / ±220 15000 / ±220 8000 / ±220 8000 / ±220 88 88 90 90 88 88 90 90 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 051e R11.J Tel: +1 514 620 2722 1 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Input Specifications Parameters Nominal 24 48 Voltage range Filter Start up time 24 48 Absolute Maximum Rating Peak Input Voltage time On/Off control Vin 9~36 Vin 36~75 24V ON/OFF 48V ON/OFF No Load Input Current Under voltage lockout Input reflected current Isolation Specifications Parameters Conditions Tested I/O voltage Case/Input tested voltage Resistance Capacitance 3 sec 3 sec Output Specifications Parameters Cross Regulation (Dual Output Models) Over voltage protection Over current protection Short Circuit protection Short circuit restart Thermal Shutdown Line voltage regulation (Single) Line voltage regulation (Dual) Line voltage regulation (Triple) Load voltage regulation (Single) Load voltage regulation (Dual) Load voltage regulation (Triple) Temperature coefficient Ripple & Noise (Single and Dual) Ripple & Noise (Triple) Voltage adjustment range (single) Minimum Load Current General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature www.aimtec.com F 051e R11.J Maximum 9-36 36-75 π (Pi) Network 30 -0.7 ~ 50 -0.7 ~ 100 VDC ms VDC Typical Rated 1600 1000 1500 Typical ±1 ±1 / ±5 ±5 100% load Derating above 50 Typical 330 -40 to +125 Tel: +1 514 620 2722 2 of 6 ms mA VDC mAp-p Units 1600 VDC VDC MOhm pF Maximum Main / Auxiliary 25% load on one output - 100% load on second load Main 100%, 25% load on Aux1 and 100% ±5 on Aux2 Zener diode clamp 120 Continuous Auto-Recovery Case temp 115 HL-LL ±0.2 HL-LL ±0.2 HL-LL Main / Auxiliary ±1 / ±5 0-100% load ±0.5 Balanced load ±1 10~100% Main / Auxiliary ±1 / ±5 ±0.02 100 20MHz bandwidth, 3.3V/5V/5.1V/±5V 150 20MHz bandwidth, 12V/15V/±12V/±15V 20MHz bandwidth Main / Auxiliary 50 / 75 ±10 10 Conditions Units 100 ON: 3 ~12VDC or open circuit OFF: 0 ~ 1.2VDC or Short circuit between pin 2 and pin 3 100 50 8.8 / 7.9 17.8 / 16 20 Conditions Voltage accuracy (Single and Dual) Voltage accuracy (Triple) Cross Regulation (Triple) Typical Units % % % o C % % % % % % %/oC mV p-p mV p-p % % of Max Maximum -40 to +75 105 Units KHz o C o C o C Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter General Specifications (continued) Parameters Conditions Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation Typical Maximum Units %/ oC 2 Free Air Convection 95 % RH Nickel coated Copper 30 g 2.00 x 1.00 x 0.4 inches 50.80 x 25.40 x 10.17 mm Single & Dual: >450000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC) Triple: >320000 hrs (MIL-HDBK -217F, Ground Benign, t=+25ºC) o 1.5mm from case for 10 sec 260 C 250 uS ±3 % Safety Specifications Parameters Agency Approval CE EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Standards Pin Out Specifications Pin 1 2 3 4 5 6 7 Single + V Input - V Input On/Off Control + V Output -V Output Trim No Pin Dual + V Input - V Input On/Off Control + V Output Common - V Output No Pin Triple + V Input - V Input On/Off Control + Vaux Output - Vaux Output Common + V Output Dimensions 4 1 5 Bottom View 3 Diameter 1.00 (0.04) www.aimtec.com F 051e R11.J 5.08 (0.20) 10.16 (0.40) 2.54 (0.10) 6 10.16 (0.40) 25.40 (1.00) 2 10.16 (0.40) 2.54 (0.10) 5.08 (0.20) 5.08 (0.20) 50.80 (2.00) 10.16 (0.40) Single and Dual Output Models 2.54 (0.10) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) Tel: +1 514 620 2722 3 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter 7.64 (0.30) 5 2 25.40 (1.00) 7.64 (0.30) 4 1 Bottom View 6 3 7 2.54 (0.10) 2.54 (0.10) 10.16 (0.40) 5.08 (0.20) 2.54 (0.10) 50.80 (2.00) 5.08 (0.20) 5.08 (0.20) 10.16 (0.40) Triple Output Models 5.08 (0.20) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) Trimming Derating Free Air Convection 50 ºC Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 75 80 100 Ambient Temperature º C On/Off Control +V input On/Off Control 4 DC/DC Converter 5 6 -V input 7 Positive logic turns on the module during high logic and off during low logic. Module can be controlled by an external switch between the On/Off CTRL terminal and –Vinput terminal. The switch can be either open collector or open drain. www.aimtec.com F 051e R11.J Tel: +1 514 620 2722 4 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Recommended Circuits C1 100uF, 100V L 12uH C2 1206, 470pF, 2KV Conducted/Radiated Emissions Single Output L +V output +V input C1 DC/DC Converter -V input Load -V output C2 Conducted/Radiated Emissions Dual Output L +V output +V input C1 DC/DC Converter Load -V output -V input Load Common C2 Conducted/Radiated Emissions Triple Output L +V input C1 Load +Vaux Output DC/DC Converter -Vaux Output +V output -V input Load Load Common C2 www.aimtec.com F 051e R11.J Tel: +1 514 620 2722 5 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-Z 30 Watt | DC-DC Converter Surge/EFT C1 220uF, 100V Su ge/ +V input 4 DC/DC Converter C1 5 6 -V input 7 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R11.J Tel: +1 514 620 2722 6 of 6 Toll free: + 1 888 9 AIMTEC (924 6832) North America only