Cypress CYV15G0104 Independent clock hotlink ii serializer and reclocking deserializer Datasheet

CYV15G0104TRB
PRELIMINARY
Independent Clock HOTLink II™ Serializer and
Reclocking Deserializer
Features
including SMPTE 292M and SMPTE 259M video applications.
It supports signaling rates in the range of 195 to 1500 Mbps
per serial link. The transmit and receive channels are
independent and can operate simultaneously at different
rates. The transmit channel accepts 10-bit parallel characters
in an Input Register and converts them to serial data. The
receive channel accepts serial data and converts it to 10-bit
parallel characters and presents these characters to an Output
Register. The received serial data can also be reclocked and
retransmitted through the reclocker serial outputs. Figure 1
illustrates typical connections between independent video coprocessors and corresponding CYV15G0104TRB chips.
• Single channel video serializer plus single channel
video reclocking deserializer
— 195- to 1500-Mbps serial data signaling rate
— Simultaneous operation at different signaling rates
• Second-generation HOTLink® technology
• Compliant to SMPTE 292M and SMPTE 259M video
standards
• Supports reception of either 1.485 or 1.485/1.001 Gbps
data rate with the same training clock
• Internal phase-locked loops (PLLs) with no external
PLL components
• Supports half-rate and full-rate clocking
• Selectable differential PECL-compatible serial inputs
— Internal DC-restoration
• Redundant differential PECL-compatible serial outputs
— No external bias resistors required
— Internal source termination
— Signaling-rate controlled edge-rates
• Synchronous LVTTL parallel interface
• JTAG boundary scan
• Built-In Self-Test (BIST) for at-speed link testing
• Link Quality Indicator
— Analog signal detect
— Digital signal detect
• Low-power 1.8W @ 3.3V typical
• Single 3.3V supply
• Thermally enhanced BGA
• 0.25µ BiCMOS technology
The CYV15G0104TRB satisfies the SMPTE 259M and
SMPTE 292M compliance as per SMPTE EG34-1999 Pathological Test Requirements.
As
a
second-generation
HOTLink
device,
the
CYV15G0104TRB extends the HOTLink family with enhanced
levels of integration and faster data rates, while maintaining
serial-link compatibility (data and BIST) with other HOTLink
devices. The transmit (TX) channel of the CYV15G0104TRB
HOTLink II device accepts scrambled 10-bit transmission
characters. These characters are serialized and output from
dual Positive ECL (PECL) compatible differential transmission-line drivers at a bit-rate of either 10- or 20-times the
input reference clock for that channel.
The receive (RX) channel of the CYV15G0104TRB HOTLink
II device accepts a serial bit-stream from one of two selectable
PECL-compatible differential line receivers, and using a
completely integrated Clock and Data Recovery PLL, recovers
the timing information necessary for data reconstruction. The
recovered bit-stream is reclocked and retransmitted through
the reclocker serial outputs. Also, the recovered serial data is
deserialized and presented to the destination host system.
The transmit and receive channels contain an independent
BIST pattern generator and checker, respectively. This BIST
hardware allows at-speed testing of the high-speed serial data
paths in each transmit and receive section, and across the
interconnecting links.
Functional Description
The CYV15G0104TRB Independent Clock HOTLink II™
Serializer and Reclocking Deserializer is a point-to-point or
point-to-multipoint communications building block enabling
transfer of data over a variety of high-speed serial links
10
Video Coprocessor
10
Independent
Channel
CYV15G0104TRB
Device
Independent
Channel
CYV15G0104TRB
Device
Serial
Links
10
Video Coprocessor
Reclocked
Output
10
Reclocked
Output
Figure 1. HOTLink II™ System Connections
Cypress Semiconductor Corporation
Document #: 38-02100 Rev. **
•
3901 North First Street
•
San Jose, CA 95134
•
408-943-2600
Revised July 14, 2004
CYV15G0104TRB
PRELIMINARY
The CYV15G0104TRB is ideal for SMPTE applications where
different data rates and serial interface standards are
necessary for each channel. Some applications include multi-
format routers, switchers, format converters, SDI monitors,
cameras, and camera control units.
x10
x10
Deserializer
Phase
Align
Buffer
REFCLKB±
TXDB[9:0]
RXDA[9:0]
TRGCLKA±
CYV15G0104TRB Serializer and Reclocking Deserializer Logic Block Diagram
Document #: 38-02100 Rev. **
Reclocker
RX
TX
ROUTA1±
ROUTA2±
INA1±
INA2±
TOUTB1±
TOUTB2±
Serializer
Page 2 of 28
CYV15G0104TRB
PRELIMINARY
Reclocking Deserializer Path Block Diagram
RESET
TRST
JTAG
Boundary
Scan
Controller
TRGRATEA
x2
TRGCLKA
TMS
TCLK
TDI
TDO
SDASEL[2..1]A[1:0]
LDTDEN
Clock &
Data
Recovery
PLL
INA2+
INA2–
ULCA
10
10
Output
Register
INA1+
INA1–
Shifter
INSELA
BIST LFSR
LFIA
Receive
Signal
Monitor
10
RXDA[9:0]
BISTSTA
RXCLKA+
RXCLKA–
÷2
SPDSELA
RXBISTA[1:0]
RXRATEA
RXPLLPDA
Recovered Serial Data
Reclocker
Output PLL
Clock Multiplier
RECLKOA
ROE[2..1]A
Register
Recovered Character Clock
ROE[2..1]A
ROUTA1+
ROUTA1–
ROUTA2+
ROUTA2–
Character-Rate Clock
REPDOA
Bit-Rate Clock
Serializer Path Block Diagram
Bit-Rate Clock
= Internal Signal
REFCLKB+
Transmit
PLL
Transmit PLL
Clock
Clock Multiplier
Multiplier
REFCLKB–
TXRATEB
TOE[2..1]B
SPDSELB
TXCLKOB
Character-Rate Clock
TXERRB
TXCLKB
PABRSTB
Document #: 38-02100 Rev. **
10
10
10
Shifter
10
BIST LFSR
TXDB[9:0]
Phase-Align
Phase-Align
Buffer
Buffer
TXCKSELB
TOE[2..1]B
TXBISTB
1
Input
Register
0
TOUTB1+
TOUTB1–
TOUTB2+
TOUTB2–
Page 3 of 28
PRELIMINARY
Device Configuration and Control Block Diagram
WREN
ADDR[2:0]
DATA[6:0]
Device Configuration
and Control Interface
Document #: 38-02100 Rev. **
CYV15G0104TRB
= Internal Signal
RXRATEA
RXPLLPDA
TRGRATEA
TXRATEB
TXCKSELB
PABRSTB
SDASEL[2..1]A[1:0]
TOE[2..1]B
ROE[2..1]A
RXBISTA[1:0]
TXBISTB
Page 4 of 28
CYV15G0104TRB
PRELIMINARY
Pin Configuration (Top View)[1]
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
T
U
V
W
Y
1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
NC
NC
NC
NC
VCC
NC
TOUT
B1–
GND
GND
TOUT
B2–
IN
A1–
ROUT
A1–
GND
IN
A2–
ROUT
A2–
VCC
VCC
NC
VCC
NC
VCC
NC
VCC
NC
VCC
VCC
TOUT
B1+
GND
NC
TOUT
B2+
IN
A1+
ROUT
A1+
GND
IN
A2+
ROUT
A2+
VCC
NC
NC
NC
NC
TDI
TMS
VCC
VCC
VCC
NC
NC
GND
DATA
[6]
DATA
[4]
DATA
[2]
DATA
[0]
GND
NC
SPD
SELB
VCC
LDTD
EN
TRST
GND
TDO
TCLK
RESET
VCC
INSELA
VCC
ULCA
NC
GND
DATA
[5]
DATA
[3]
DATA
[1]
GND
GND
GND
NC
VCC
NC
VCC
SCAN TMEN3
EN2
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
NC
NC
VCC
NC
VCC
NC
NC
NC
GND
WREN
GND
GND
NC
NC
SPD
SELA
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
NC
NC
NC
NC
GND
GND
NC
NC
NC
NC
NC
NC
NC
GND
NC
NC
NC
GND
NC
NC
NC
NC
NC
NC
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
NC
NC
GND
GND
GND
GND
NC
NC
NC
NC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
TX
DB[0]
TX
DB[1]
TX
DB[2]
TX
DB[9]
VCC
NC
NC
GND
GND
ADDR
[0]
REF
CLKB–
TX
DB[3]
TX
DB[4]
TX
DB[8]
NC
VCC
NC
NC
GND
NC
GND
REF
RE
CLKB+ CLKOA
TX
DB[5]
TX
DB[7]
NC
NC
VCC
NC
NC
GND
ADDR
[2]
ADDR
[1]
TX
DB[6]
TX
CLKB
NC
NC
VCC
NC
NC
GND
TX
CLKOB
NC
GND
GND
VCC
VCC
RX
DA[4]
VCC
BIST
STA
RX
DA[0]
GND
GND
VCC
VCC
RX
DA[9]
RX
DA[5]
RX
DA[2]
RX
DA[1]
RX
REPDO GND
CLKA+
A
GND
VCC
VCC
LFIA
TRG
CLKA+
RX
DA[6]
RX
DA[3]
RX
CLKA–
GND
VCC
VCC
TX
ERRB
TRG
CLKA–
RX
DA[8]
RX
DA[7]
GND
GND
GND
NC = Do not connect.
Document #: 38-02100 Rev. **
Page 5 of 28
CYV15G0104TRB
PRELIMINARY
Pin Configuration (Bottom View)[1]
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
T
U
V
W
Y
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
NC
VCC
NC
VCC
VCC
ROUT
A2–
IN
A2–
GND
ROUT
A1–
IN
A1–
TOUT
B2–
GND
GND
TOUT
B1–
NC
VCC
NC
NC
NC
NC
NC
NC
NC
NC
VCC
ROUT
A2+
IN
A2+
GND
ROUT
A1+
IN
A1+
TOUT
B2+
NC
GND
TOUT
B1+
VCC
VCC
NC
VCC
NC
VCC
TDO
GND
TRST
LDTD
EN
VCC
SPD
SELB
NC
GND
DATA
[0]
DATA
[2]
DATA
[4]
DATA
[6]
GND
NC
NC
VCC
VCC
VCC
TMS
TDI
TMEN3 SCAN
EN2
VCC
NC
VCC
NC
GND
GND
GND
DATA
[1]
DATA
[3]
DATA
[5]
GND
NC
ULCA
VCC
INSELA
VCC
RESET
TCLK
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
NC
NC
NC
VCC
NC
VCC
NC
NC
NC
SPD
SELA
NC
NC
GND
GND
WREN
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
NC
NC
GND
GND
GND
GND
NC
NC
NC
NC
GND
GND
NC
NC
GND
NC
NC
NC
GND
NC
NC
NC
GND
NC
NC
NC
NC
NC
NC
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
NC
NC
VCC
VCC
VCC
VCC
NC
NC
NC
NC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
VCC
RX
DA[0]
BIST
STA
VCC
RX
DA[4]
VCC
VCC
GND
GND
RX
DA[1]
RX
DA[2]
RX
DA[5]
RX
DA[9]
VCC
VCC
GND
GND
RX
DA[3]
RX
DA[6]
TRG
CLKA+
LFIA
VCC
VCC
GND
GND REPDO
RX
DA[7]
RX
DA[8]
TRG
CLKA–
TX
ERRB
VCC
VCC
GND
GND
Document #: 38-02100 Rev. **
REF
CLKB–
ADDR
[0]
GND
GND
NC
NC
VCC
TX
DB[9]
TX
DB[2]
TX
DB[1]
TX
DB[0]
RE
REF
CLKOA CLKB+
GND
NC
GND
NC
NC
VCC
NC
TX
DB[8]
TX
DB[4]
TX
DB[3]
RX
CLKA+
ADDR
[1]
ADDR
[2]
GND
NC
NC
VCC
NC
NC
TX
DB[7]
TX
DB[5]
GND
NC
TX
CLKOB
GND
NC
NC
VCC
NC
NC
TX
CLKB
TX
DB[6]
GND
A
RX
CLKA–
Page 6 of 28
PRELIMINARY
CYV15G0104TRB
Pin Definitions
CYV15G0104TRB HOTLink II Serializer and Reclocking Deserializer
Name
I/O Characteristics
Signal Description
Transmit Path Data and Status Signals
TXDB[9:0]
LVTTL Input,
synchronous,
sampled by
TXCLKB↑ or
REFCLKB↑[2]
Transmit Data Inputs. TXDB[9:0] data inputs are captured on the rising edge of the
transmit interface clock. The transmit interface clock is selected by the TXCKSELB
latch via the device configuration interface.
TXERRB
LVTTL Output,
synchronous to
REFCLKB↑ [3],
asynchronous to
transmit channel
enable / disable,
asynchronous to loss
or return of
REFCLKB±
Transmit Path Error. TXERRB is asserted HIGH to indicate detection of a transmit
Phase-Align Buffer underflow or overflow. If an underflow or overflow condition is
detected, TXERRB, is asserted HIGH and remains asserted until the transmit
Phase-Align Buffer is re-centered with the PABRSTB latch via the device configuration interface. When TXBISTB = 0, the BIST progress is presented on the TXERRB
output. The TXERRB signal pulses HIGH for one transmit-character clock period to
indicate a pass through the BIST sequence once every 511 character times.
TXERRB is also asserted HIGH, when any of the following conditions is true:
• The TXPLL is powered down. This occurs when TOE2B and TOE1B are both
disabled by setting TOE2B = 0 and TOE1B = 0.
• The absence of the REFCLKB± signal.
Transmit Path Clock Signals
REFCLKB±
Differential LVPECL
or single-ended
LVTTL input clock
Reference Clock. REFCLKB± clock inputs are used as the timing reference for the
transmit PLL. This input clock may also be selected to clock the transmit parallel
interface. When driven by a single-ended LVCMOS or LVTTL clock source, connect
the clock source to either the true or complement REFCLKB input, and leave the
alternate REFCLKB input open (floating). When driven by an LVPECL clock source,
the clock must be a differential clock, using both inputs.
TXCLKB
LVTTL Clock Input,
internal pull-down
Transmit Path Input Clock. When configuration latch TXCKSELB = 0, the
associated TXCLKB input is selected as the character-rate input clock for the
TXDB[9:0] input. In this mode, the TXCLKB input must be frequency-coherent to its
TXCLKOB output clock, but may be offset in phase by any amount. Once initialized,
TXCLKB is allowed to drift in phase by as much as ±180 degrees. If the input phase
of TXCLKB drifts beyond the handling capacity of the Phase Align Buffer, TXERRB
is asserted to indicate the loss of data, and remains asserted until the Phase Align
Buffer is initialized. The phase of TXCLKB relative to REFCLKB± is initialized when
the configuration latch PABRSTB is written as 0. When TXERRB is deasserted, the
Phase Align Buffer is initialized and input characters are correctly captured.
TXCLKOB
LVTTL Output
Transmit Clock Output. TXCLKOB output clock is synthesized by the transmit PLL
and operates synchronous to the internal transmit character clock. TXCLKOB
operates at either the same frequency as REFCLKB± (TXRATEB = 0), or at twice
the frequency of REFCLKB± (TXRATEB = 1). The transmit clock outputs have no
fixed phase relationship to REFCLKB±.
Receive Path Data and Status Signals
RXDA[9:0]
LVTTL Output,
synchronous to the
RXCLKA ± output
Parallel Data Output. RXDA[9:0] parallel data outputs change relative to the receive
interface clock. If RXCLKA± is a full-rate clock, the RXCLKA± clock outputs are
complementary clocks operating at the character rate. The RXDA[9:0] outputs for
the associated receive channels follow rising edge of RXCLKA+ or falling edge of
RXCLKA–. If RXCLKA± is a half-rate clock, the RXCLKA± clock outputs are complementary clocks operating at half the character rate. The RXDA[9:0] outputs for the
associated receive channels follow both the falling and rising edges of the
associated RXCLKA± clock outputs.
When BIST is enabled on the receive channel, the BIST status is presented on the
RXDA[1:0] and BISTSTA outputs. See Table 6 for each status reported by the BIST
state machine. Also, while BIST is enabled, the RXDA[9:2] outputs should be
ignored.
Notes:
2. When REFCLKB± is configured for half-rate operation, these inputs are sampled relative to both the rising and falling edges of the associated REFCLKB±.
3. When REFCLKB± is configured for half-rate operation, this output is presented relative to both the rising and falling edges of the associated REFCLKB±.
Document #: 38-02100 Rev. **
Page 7 of 28
PRELIMINARY
CYV15G0104TRB
Pin Definitions (continued)
CYV15G0104TRB HOTLink II Serializer and Reclocking Deserializer
Name
I/O Characteristics
BISTSTA
LVTTL Output,
synchronous to the
RXCLKA ± output
REPDOA
Asynchronous to
reclocker output
channel
enable / disable
Signal Description
BIST Status Output. When RXBISTA[1:0] = 10, BISTSTA (along with RXDA[1:0])
displays the status of the BIST reception. See Table 6 for the BIST status reported
for each combination of BISTSTA and RXDA[1:0].
When RXBISTA[1:0] ≠ 10, BISTSTA should be ignored.
Reclocker Powered Down Status Output. REPDOA is asserted HIGH, when the
reclocker output logic is powered down. This occurs when ROE2A and ROE1A are
both disabled by setting ROE2A = 0 and ROE1A = 0.
Receive Path Clock Signals
TRGCLKA±
Differential LVPECL
or single-ended
LVTTL input clock
CDR PLL Training Clock. TRGCLKA± clock inputs are used as the reference
source for the frequency detector (Range Controller) of the receive PLL to reduce
PLL acquisition time.
In the presence of valid serial data, the recovered clock output of the receive CDR
PLL (RXCLKA±) has no frequency or phase relationship with TRGCLKA±.
When driven by a single-ended LVCMOS or LVTTL clock source, connect the clock
source to either the true or complement TRGCLKA input, and leave the alternate
TRGCLKA input open (floating). When driven by an LVPECL clock source, the clock
must be a differential clock, using both inputs.
RXCLKA±
LVTTL Output Clock
Receive Clock Output. RXCLKA± is the receive interface clock used to control
timing of the RXDA[9:0] parallel outputs. These true and complement clocks are
used to control timing of data output transfers. These clocks are output continuously
at either the half-character rate (1/20th the serial bit-rate) or character rate (1/10th
the serial bit-rate) of the data being received, as selected by RXRATEA.
RECLKOA
LVTTL Output
Reclocker Clock Output. RECLKOA output clock is synthesized by the reclocker
output PLL and operates synchronous to the internal recovered character clock.
RECLKOA operates at either the same frequency as RXCLKA± (RXRATEA = 0), or
at twice the frequency of RXCLKA± (RXRATEA = 1).The reclocker clock outputs
have no fixed phase relationship to RXCLKA±.
Device Control Signals
RESET
LVTTL Input,
asynchronous,
internal pull-up
Asynchronous Device Reset. RESET initializes all state machines, counters, and
configuration latches in the device to a known state. RESET must be asserted LOW
for a minimum pulse width. When the reset is removed, all state machines, counters
and configuration latches are at an initial state. See Table 4 for the initialize values
of the device configuration latches.
LDTDEN
LVTTL Input,
internal pull-up
Level Detect Transition Density Enable. When LDTDEN is HIGH, the Signal Level
Detector, Range Controller, and Transition Density Detector are all enabled to
determine if the RXPLL tracks TRGCLKA± or the selected input serial data stream.
If the Signal Level Detector, Range Controller, or Transition Density Detector are out
of their respective limits while LDTDEN is HIGH, the RXPLL locks to TRGCLKA±
until such a time they become valid. SDASEL[2..1]A[1:0] is used to configure the trip
level of the Signal Level Detector. The Transition Density Detector limit is one
transition in every 60 consecutive bits. When LDTDEN is LOW, only the Range
Controller is used to determine if the RXPLL tracks TRGCLKA± or the selected input
serial data stream. it is recommended to set LDTDEN = HIGH.
ULCA
LVTTL Input,
internal pull-up
Use Local Clock. When ULCA is LOW, the RXPLL is forced to lock to TRGCLKA±
instead of the received serial data stream. While ULCA is LOW, the link fault indicator
LFIA is LOW indicating a link fault.
When ULCA is HIGH, the RXPLL performs Clock and Data Recovery functions on
the input data streams. This function is used in applications in which a stable
RXCLKA± is needed. In cases when there is an absence of valid data transitions for
a long period of time, or the high-gain differential serial inputs (INA±) are left floating,
there may be brief frequency excursions of the RXCLKA± outputs from TRGCLKA±.
Document #: 38-02100 Rev. **
Page 8 of 28
PRELIMINARY
CYV15G0104TRB
Pin Definitions (continued)
CYV15G0104TRB HOTLink II Serializer and Reclocking Deserializer
Name
SPDSELA
SPDSELB
I/O Characteristics
3-Level Select[4]
static control input
Signal Description
Serial Rate Select. The SPDSELA and SPDSELB inputs specify the operating
signaling-rate range of the receive and transmit PLL, respectively.
LOW = 195 – 400 MBd
MID = 400 – 800 MBd
HIGH = 800 – 1500 MBd.
INSELA
LVTTL Input,
asynchronous
Receive Input Selector. The INSELA input determines which external serial bit
stream is passed to the receiver’s Clock and Data Recovery circuit. When INSELA
is HIGH, the Primary Differential Serial Data Input, INA1±, is selected for the receive
channel. When INSELA is LOW, the Secondary Differential Serial Data Input, INA2±,
is selected for the receive channel.
LFIA
LVTTL Output,
asynchronous
Link Fault Indication Output. LFIA is an output status indicator signal. LFIA is the
logical OR of six internal conditions. LFIA is asserted LOW when any of the following
conditions is true:
• Received serial data rate outside expected range
• Analog amplitude below expected levels
• Transition density lower than expected
• Receive channel disabled
• ULCA is LOW
• Absence of TRGCLKA±.
Device Configuration and Control Bus Signals
WREN
LVTTL input,
asynchronous,
internal pull-up
Control Write Enable. The WREN input writes the values of the DATA[6:0] bus into
the latch specified by the address location on the ADDR[2:0] bus.[5]
ADDR[2:0]
LVTTL input
asynchronous,
internal pull-up
Control Addressing Bus. The ADDR[2:0] bus is the input address bus used to
configure the device. The WREN input writes the values of the DATA[6:0] bus into
the latch specified by the address location on the ADDR[2:0] bus.[5] Table 4 lists the
configuration latches within the device, and the initialization value of the latches upon
the assertion of RESET. Table 5 shows how the latches are mapped in the device.
DATA[6:0]
LVTTL input
asynchronous,
internal pull-up
Control Data Bus. The DATA[6:0] bus is the input data bus used to configure the
device. The WREN input writes the values of the DATA[6:0] bus into the latch
specified by address location on the ADDR[2:0] bus.[5 ] Table 4 lists the configuration
latches within the device, and the initialization value of the latches upon the assertion
of RESET. Table 5 shows how the latches are mapped in the device.
Internal Device Configuration Latches
RXRATEA
Internal Latch[6]
SDASEL[2..1]A[1 Internal Latch[6]
:0]
TXCKSELB
Internal Latch[6]
Latch[6]
TXRATEB
Internal
TRGRATEA
Internal Latch[6]
RXPLLPDA
Internal
Latch[6]
RXBISTA[1:0]
Internal Latch[6]
Latch[6]
Receive Clock Rate Select.
Signal Detect Amplitude Select.
Transmit Clock Select.
Transmit PLL Clock Rate Select.
Reclocker Output PLL Clock Rate Select.
Receive Channel Power Control.
Receive Bist Disabled.
TXBISTB
Internal
TOE2B
Internal Latch[6]
Transmitter Differential Serial Output Driver 2 Enable.
TOE1B
Latch[6]
Transmitter Differential Serial Output Driver 1 Enable.
Internal
Transmit Bist Disabled.
Notes:
4. 3-Level Select inputs are used for static configuration. These are ternary inputs that make use of logic levels of LOW, MID, and HIGH. The LOW level is
usually implemented by direct connection to VSS (ground). The HIGH level is usually implemented by direct connection to VCC (power). The MID level is
usually implemented by not connecting the input (left floating), which allows it to self bias to the proper level.
5. See Device Configuration and Control Interface for detailed information on the operation of the Configuration Interface.
6. See Device Configuration and Control Interface for detailed information on the internal latches.
Document #: 38-02100 Rev. **
Page 9 of 28
PRELIMINARY
CYV15G0104TRB
Pin Definitions (continued)
CYV15G0104TRB HOTLink II Serializer and Reclocking Deserializer
Name
I/O Characteristics
Signal Description
ROE2A
Internal Latch[6]
Reclocker Differential Serial Output Driver 2 Enable.
ROE1A
Internal Latch[6]
Reclocker Differential Serial Output Driver 1 Enable.
PABRSTB
Internal Latch[6]
Transmit Clock Phase Alignment Buffer Reset.
Factory Test Modes
SCANEN2
LVTTL input,
internal pull-down
Factory Test 2. SCANEN2 input is for factory testing only. This input may be left as
a NO CONNECT, or GND only.
TMEN3
LVTTL input,
internal pull-down
Factory Test 3. TMEN3 input is for factory testing only. This input may be left as a
NO CONNECT, or GND only.
TOUTB1±
CML Differential
Output
Transmitter Primary Differential Serial Data Output. The transmitter TOUTB1±
PECL-compatible CML outputs (+3.3V referenced) are capable of driving terminated
transmission lines or standard fiber-optic transmitter modules, and must be ACcoupled for PECL-compatible connections.
TOUTB2±
CML Differential
Output
Transmitter Secondary Differential Serial Data Output. The transmitter TOUTB2±
PECL-compatible CML outputs (+3.3V referenced) are capable of driving terminated
transmission lines or standard fiber-optic transmitter modules, and must be AC-coupled
for PECL-compatible connections.
ROUTA1±
CML Differential
Output
Reclocker Primary Differential Serial Data Output. The reclocker ROUTA1±
PECL-compatible CML outputs (+3.3V referenced) are capable of driving terminated
transmission lines or standard fiber-optic transmitter modules, and must be ACcoupled for PECL-compatible connections.
ROUTA2±
CML Differential
Output
Reclocker Secondary Differential Serial Data Output. The reclocker ROUTA2±
PECL-compatible CML outputs (+3.3V referenced) are capable of driving terminated
transmission lines or standard fiber-optic transmitter modules, and must be AC-coupled
for PECL-compatible connections.
INA1±
Differential Input
Primary Differential Serial Data Input. The INA1± input accepts the serial data
stream for deserialization. The INA1± serial stream is passed to the receive CDR
circuit to extract the data content when INSELA = HIGH.
INA2±
Differential Input
Secondary Differential Serial Data Input. The INA2± input accepts the serial data
stream for deserialization. The INA2± serial stream is passed to the receiver CDR
circuit to extract the data content when INSELA = LOW.
TMS
LVTTL Input,
internal pull-up
Test Mode Select. Used to control access to the JTAG Test Modes. If maintained
high for ≥5 TCLK cycles, the JTAG test controller is reset.
TCLK
LVTTL Input,
internal pull-down
JTAG Test Clock.
TDO
3-State LVTTL
Output
Test Data Out. JTAG data output buffer. High-Z while JTAG test mode is not
selected.
TDI
LVTTL Input,
internal pull-up
Test Data In. JTAG data input port.
TRST
LVTTL Input,
internal pull-up
JTAG reset signal. When asserted (LOW), this input asynchronously resets the
JTAG test access port controller.
Analog I/O
JTAG Interface
Power
VCC
+3.3V Power.
GND
Signal and Power Ground for all internal circuits.
CYV15G0104TRB HOTLink II Operation
The CYV15G0104TRB is a highly configurable, independent
clocking device designed to support reliable transfer of large
Document #: 38-02100 Rev. **
quantities of digital video data, using high-speed serial links
from multiple sources to multiple destinations.
Page 10 of 28
CYV15G0104TRB
PRELIMINARY
CYV15G0104TRB Transmit Data Path
Input Register
The parallel input bus TXDB[9:0] can be clocked in using
TXCLKB (TXCKSELB = 0) or REFCLKB (TXCKSELB = 1).
Phase-Align Buffer
Data from the Input Register is passed to the Phase-Align
Buffer, when the TXDB[9:0] input register is clocked using
TXCLKBA (TXCKSELB = 0) or when REFCLKB is a half-rate
clock (TXCKSELB = 1 and TXRATEB = 1). When the
TXDB[9:0] input register is clocked using REFCLKB±
(TXCKSELA = 1) and REFCLKB± is a full-rate clock
(TXRATEB = 0), the associated Phase Alignment Buffer in the
transmit path is bypassed. These buffers are used to absorb
clock phase differences between the TXCLKB input clock and
the internal character clock for that channel.
Once initialized, TXCLKB is allowed to drift in phase as much
as ±180 degrees. If the input phase of TXCLKB drifts beyond
the handling capacity of the Phase Align Buffer, TXERRB is
asserted to indicate the loss of data, and remains asserted
until the Phase Align Buffer is initialized. The phase of
TXCLKB relative to its internal character rate clock is initialized
when the configuration latch PABRSTB is written as 0. When
the associated TXERRB is deasserted, the Phase Align Buffer
is initialized and input characters are correctly captured.
If the phase offset, between the initialized location of the input
clock and REFCLKB, exceeds the skew handling capabilities
of the Phase-Align Buffer, an error is reported on that
channel’s TXERRB output. This output indicates an error
continuously until the Phase-Align Buffer for that channel is
reset. While the error remains active, the transmitter for that
channel outputs a continuous “1001111000” character to
indicate to the remote receiver that an error condition is
present in the link.
Transmit BIST
The transmit channel contains an internal pattern generator
that can be used to validate both the link and device operation.
This generator is enabled by the TXBISTB latch via the device
configuration interface. When enabled, a register in the
transmit channel becomes a signature pattern generator by
logically converting to a Linear Feedback Shift Register
(LFSR). This LFSR generates a 511-character sequence. This
provides a predictable yet pseudo-random sequence that can
be matched to an identical LFSR in the attached Receiver(s).
A device reset (RESET sampled LOW) presets the BIST
Enable Latches to disable BIST on all channels.
All data present at the TXDB[9:0] inputs are ignored when
BIST is active on that channel.
Transmit PLL Clock Multiplier
The Transmit PLL Clock Multiplier accepts a character-rate or
half-character-rate external clock at the REFCLKB± input, and
that clock is multiplied by 10 or 20 (as selected by TXRATEB)
to generate a bit-rate clock for use by the transmit shifter. It
also provides a character-rate clock used by the transmit
paths, and outputs this character rate clock as TXCLKOB.
The clock multiplier PLL can accept a REFCLKB± input
between 19.5 MHz and 150 MHz, however, this clock range is
Document #: 38-02100 Rev. **
limited by the operating mode of the CYV15G0104TRB clock
multiplier (TXRATEB) and by the level on the SPDSELB input.
SPDSELB is a 3-level select[4] input that selects one of three
operating ranges for the serial data outputs of the transmit
channel. The operating serial signaling-rate and allowable
range of REFCLKB± frequencies are listed in Table 1.
Table 1. Operating Speed Settings
SPDSELB
TXRATEB
REFCLKB±
Frequency
(MHz)
LOW
1
reserved
0
19.5 – 40
MID (Open)
1
20 – 40
0
40 – 80
HIGH
1
40 – 75
0
80 – 150
Signaling
Rate (Mbps)
195 – 400
400 – 800
800 – 1500
The REFCLKB± inputs are differential inputs with each input
internally biased to 1.4V. If the REFCLKB+ input is connected
to a TTL, LVTTL, or LVCMOS clock source, the input signal is
recognized when it passes through the internally biased
reference point. When driven by a single-ended TTL, LVTTL,
or LVCMOS clock source, connect the clock source to either
the true or complement REFCLKB input, and leave the
alternate REFCLKB input open (floating).
When both the REFCLKB+ and REFCLKB– inputs are
connected, the clock source must be a differential clock. This
can either be a differential LVPECL clock that is DC-or
AC-coupled or a differential LVTTL or LVCMOS clock.
By connecting the REFCLKB– input to an external voltage
source, it is possible to adjust the reference point of the
REFCLKB+ input for alternate logic levels. When doing so, it
is necessary to ensure that the input differential crossing point
remains within the parametric range supported by the input.
Transmit Serial Output Drivers
The serial output interface drivers use differential Current
Mode Logic (CML) drivers to provide source-matched drivers
for 50Ω transmission lines. These drivers accept data from the
transmit shifter. These drivers have signal swings equivalent
to that of standard PECL drivers, and are capable of driving
AC-coupled optical modules or transmission lines.
Transmit Channels Enabled
Each driver can be enabled or disabled separately via the
device configuration interface.
When a driver is disabled via the configuration interface, it is
internally powered down to reduce device power. If both
transmit serial drivers are in this disabled state, the transmitter
internal logic for that channel is also powered down. A device
reset (RESET sampled LOW) disables all output drivers.
Note. When the disabled transmit channel (i.e., both outputs
disabled) is re-enabled:
• the data on the transmit serial outputs may not meet all
timing specifications for up to 250 µs
• the state of the phase-align buffer cannot be guaranteed,
and a phase-align reset is required if the phase-align buffer
is used
Page 11 of 28
CYV15G0104TRB
PRELIMINARY
CYV15G0104TRB Receive Data Path
Transition Density
Serial Line Receivers
The Transition Detection logic checks for the absence of
transitions spanning greater than six transmission characters
Two differential Line Receivers, INA1± and INA2±, are
available on the receive channel for accepting serial data
streams. The active Serial Line Receiver is selected using the
INSELA input. The Serial Line Receiver inputs are differential,
and can accommodate wire interconnect and filtering losses
or transmission line attenuation greater than 16 dB. For
normal operation, these inputs should receive a signal of at
least VIDIFF > 100 mV, or 200 mV peak-to-peak differential.
Each Line Receiver can be DC- or AC-coupled to +3.3V
powered fiber-optic interface modules (any ECL/PECL family,
not limited to 100K PECL) or AC-coupled to +5V powered
optical modules. The common-mode tolerance of these line
receivers accommodates a wide range of signal termination
voltages. Each receiver provides internal DC-restoration, to
the center of the receiver’s common mode range, for ACcoupled signals.
Signal Detect/Link Fault
Each selected Line Receiver (i.e., that routed to the clock and
data recovery PLL) is simultaneously monitored for
• analog amplitude above amplitude level selected by
SDASELA
• transition density above the specified limit
• range controls report the received data stream inside
normal frequency range (±1500 ppm[24])
• receive channel enabled
• Presence of reference clock
• ULCA is not asserted.
All of these conditions must be valid for the Signal Detect block
to indicate a valid signal is present. This status is presented on
the LFIA (Link Fault Indicator) output associated with each
receive channel, which changes synchronous to the receive
interface clock.
(60 bits). If no transitions are present in the data received, the
Detection logic for that channel asserts LFIA.
Range Controls
The CDR circuit includes logic to monitor the frequency of the
PLL Voltage Controlled Oscillator (VCO) used to sample the
incoming data stream. This logic ensures that the VCO
operates at, or near the rate of the incoming data stream for
two primary cases:
• when the incoming data stream resumes after a time in
which it has been “missing.”
• when the incoming data stream is outside the acceptable
signaling rate range.
To perform this function, the frequency of the RXPLL VCO is
periodically compared to the frequency of the TRGCLKA±
input. If the VCO is running at a frequency beyond
±1500ppm[24] as defined by the TRGCLKA± frequency, it is
periodically forced to the correct frequency (as defined by
TRGCLKA±, SPDSELA, and TRGRATEA) and then released
in an attempt to lock to the input data stream.
The sampling and relock period of the Range Control is calculated as follows: RANGE_CONTROL_ SAMPLING_PERIOD
= (RECOVERED BYTE CLOCK PERIOD) * (4096).
During the time that the Range Control forces the RXPLL VCO
to track TRGCLKA±, the LFIA output is asserted LOW. After a
valid serial data stream is applied, it may take up to one
RANGE CONTROL SAMPLING PERIOD before the PLL
locks to the input data stream, after which LFIA should be
HIGH.
The operating serial signaling-rate and allowable range of
TRGCLKA± frequencies are listed in Table 3.
Table 3. Operating Speed Settings
Analog Amplitude
While most signal monitors are based on fixed constants, the
analog amplitude level detection is adjustable to allow
operation with highly attenuated signals, or in high-noise
environments. The analog amplitude level detection is set by
the SDASELA latch via device configuration interface. The
SDASELA latch sets the trip point for the detection of a valid
signal at one of three levels, as listed in Table 2. This control
input affects the analog monitors for all receive channels. The
Analog Signal Detect monitors are active for the Line Receiver
as selected by the INSELA input.
Table 2. Analog Amplitude Detect Valid Signal
SDASELA
Levels[7]
Typical Signal with Peak Amplitudes
Above
00
Analog Signal Detector is disabled
01
140 mV p-p differential
10
280 mV p-p differential
11
420 mV p-p differential
SPDSELA
TRGRATEA
TRGCLKA±
Frequency
(MHz)
LOW
1
reserved
0
19.5 – 40
MID (Open)
1
20 – 40
0
40 – 80
HIGH
1
40 – 75
0
80 – 150
Signaling
Rate (Mbps)
195 – 400
400 – 800
800 – 1500
Receive Channel Enabled
The receive channel can be enabled or disabled through the
RXPLLPDA input latch as controlled by the device configuration interface. When RXPLLPDA = 0, the CDR PLL and
analog circuitry of the channel are disabled. Any disabled
channel indicates a constant link fault condition on the LFIA
output. When RXPLLPDA = 1, the CDR PLL and receive
channel are enabled to receive a serial stream.
Note:
7. The peak amplitudes listed in this table are for typical waveforms that have generally 3 – 4 transitions for every ten bits. In a worse case environment the signals
may have a sine-wave appearance (highest transition density with repeating 0101...). Signal peak amplitudes levels within this environment type could increase
the values in the table above by approximately 100 mV.
Document #: 38-02100 Rev. **
Page 12 of 28
PRELIMINARY
CYV15G0104TRB
Note. When the disabled receive channel is reenabled, the
status of the LFIA output and data on the parallel outputs for
the associated channel may be indeterminate for up to 2 ms.
drivers, and are capable of driving AC-coupled optical
modules or transmission lines.
Clock/Data Recovery
Each driver can be enabled or disabled separately via the
device configuration interface.
The extraction of a bit-rate clock and recovery of bits from the
received serial stream is performed by a separate CDR block
within the receive channel. The clock extraction function is
performed by an integrated PLL that tracks the frequency of
the transitions in the incoming bit stream and aligns the phase
of the internal bit-rate clock to the transitions in the selected
serial data stream.
Each CDR accepts a character-rate (bit-rate ÷ 10) or halfcharacter-rate (bit-rate ÷ 20) training clock from the
TRGCLKA± input. This TRGCLKA± input is used to
• ensure that the VCO (within the CDR) is operating at the
correct frequency (rather than a harmonic of the bit-rate)
• reduce PLL acquisition time
• limit unlocked frequency excursions of the CDR VCO when
there is no input data present at the selected Serial Line
Receiver.
Regardless of the type of signal present, the CDR attempts to
recover a data stream from it. If the signaling rate of the
recovered data stream is outside the limits set by the range
control monitors, the CDR tracks TRGCLKA± instead of the
data stream. Once the CDR output (RXCLKA±) frequency
returns back close to the TRGCLKA± frequency, the CDR
input is switched back to the input data stream. If no data is
present at the selected line receiver, this switching behavior
may result in brief RXCLKA± frequency excursions from
TRGCLKA±. However, the validity of the input data stream is
indicated by the LFIA output. The frequency of TRGCLKA± is
required to be within ±1500ppm[24] of the frequency of the
clock that drives the REFCLKB± input of the remote transmitter to ensure a lock to the incoming data stream. This large
ppm tolerance allows the CDR PLL to reliably receive a 1.485
or 1.485/1.001 Gbps SMPTE HD-SDI data stream with a
constant TRGCLK frequency.
For systems using multiple or redundant connections, the
LFIA output can be used to select an alternate data stream.
When an LFIA indication is detected, external logic can toggle
selection of the INA1± and INA2± input through the INSELA
input. When a port switch takes place, it is necessary for the
receive PLL for that channel to reacquire the new serial
stream.
Reclocker
The receive channel performs a reclocker function on the
incoming serial data. To do this, the Clock and Data Recovery
PLL first recovers the clock from the data. The data is retimed
by the recovered clock and then passed to an output register.
Also, the recovered character clock from the receive PLL is
passed to the reclocker output PLL which generates the bit
clock that is used to clock the retimed data into the output
register. This data stream is then transmitted through the
differential serial outputs.
Reclocker Serial Output Drivers
The serial output interface drivers use differential Current
Mode Logic (CML) drivers to provide source-matched drivers
for 50Ω transmission lines. These drivers accept data from the
reclocker output register in the reclocker channel. These
drivers have signal swings equivalent to that of standard PECL
Document #: 38-02100 Rev. **
Reclocker Output Channels Enabled
When a driver is disabled via the configuration interface, it is
internally powered down to reduce device power. If both
reclocker serial drivers are in this disabled state, the internal
reclocker logic is also powered down. The deserialization logic
and parallel outputs will remain enabled. A device reset
(RESET sampled LOW) disables all output drivers.
Note. When the disabled reclocker function (i.e., both outputs
disabled) is re-enabled, the data on the reclocker serial
outputs may not meet all timing specifications for up to 250 µs.
Output Bus
The receive channel presents a 10-bit data signal (and a BIST
status signal when RXBISTA[1:0] = 10).
Receive BIST Operation
The receiver channel contains an internal pattern checker that
can be used to validate both device and link operation. These
pattern checkers are enabled by the RXBISTA[1:0] latch via
the device configuration interface. When enabled, a register in
the receive channel becomes a signature pattern generator
and checker by logically converting to a Linear Feedback Shift
Register (LFSR). This LFSR generates a 511-character
sequence. This provides a predictable yet pseudo-random
sequence that can be matched to an identical LFSR in the
attached Transmitter(s). When synchronized with the received
data stream, the Receiver checks each character from the
deserializer with each character generated by the LFSR and
indicates compare errors and BIST status at the RXDA[1:0]
and BISTSTA bits of the Output Register.
The BIST status bus {BISTSTA, RXDA[0], RXDA[1]} indicates
010b or 100b for one character period per BIST loop to
indicate loop completion. This status can be used to check test
pattern progress.
The specific status reported by the BIST state machine is listed
in Table 6. These same codes are reported on the receive
status outputs.
If the number of invalid characters received ever exceeds the
number of valid characters by 16, the receive BIST state
machine aborts the compare operations and resets the LFSR
to look for the start of the BIST sequence again.
A device reset (RESET sampled LOW) presets the BIST
Enable Latches to disable BIST on all channels.
BIST Status State Machine
When a receive path is enabled to look for and compare the
received data stream with the BIST pattern, the {BISTSTA,
RXDA[1:0]} bits identify the present state of the BIST compare
operation.
The BIST state machine has multiple states, as shown in
Figure 2 and Table 6. When the receive PLL detects an out-oflock condition, the BIST state is forced to the Start-of-BIST
state, regardless of the present state of the BIST state
machine. If the number of detected errors ever exceeds the
number of valid matches by greater than 16, the state machine
Page 13 of 28
PRELIMINARY
is forced to the WAIT_FOR_BIST state where it monitors the
receive path for the first character of the next BIST sequence.
Power Control
The CYV15G0104TRB supports user control of the powered
up or down state of each transmit and receive channel. The
receive channels are controlled by the RXPLLPDA latch via
the device configuration interface. When RXPLLPDA = 0, the
receive PLL and analog circuitry of the channel is disabled.
The transmit channel is controlled by the TOE1B and the
TOE2B latches via the device configuration interface. The
reclocker function is controlled by the ROE1A and the ROE2A
latches via the device configuration interface. When a driver is
disabled via the configuration interface, it is internally powered
down to reduce device power. If both serial drivers for a
channel are in this disabled state, the associated internal logic
for that channel is also powered down. When the reclocker
serial drivers are disabled, the reclocker function will be
disabled, but the deserialization logic and parallel outputs will
remain enabled.
Device Reset State
When the CYV15G0104TRB is reset by assertion of RESET,
all state machines, counters, and configuration latches in the
device are initialized to a reset state. See Table 4 for the
initialize values of the configuration latches.
Following a device reset, it is necessary to enable the transmit
and receive channels used for normal operation. This can be
done by sequencing the appropriate values on the device
configuration interface.[5]
CYV15G0104TRB
Device Configuration and Control Interface
The CYV15G0104TRB is highly configurable via the configuration interface. The configuration interface allows the transmitter and reclocker to be configured independently. Table 4
lists the configuration latches within the device including the
initialization value of the latches upon the assertion of RESET.
Table 5 shows how the latches are mapped in the device.
Each row in the Table 5 maps to a 7-bit latch bank. There are
6 such write-only latch banks. When WREN = 0, the logic value
in the DATA[6:0] is latched to the latch bank specified by the
values in ADDR[2:0]. The second column of Table 5 specifies
the channels associated with the corresponding latch bank.
For example, the first three latch banks (0,1 and 2) consist of
configuration bits for the reclocker channel A.
Latch Types
There are two types of latch banks: static (S) and dynamic (D).
Each channel is configured by 2 static and 1 dynamic latch
banks. The S type contain those settings that normally do not
change for a given application, whereas the D type controls
the settings that could change during the application's lifetime.
The first and second rows of each channel (address numbers
0, 1, 5, and 6) are the static control latches. The third row of
latches for each channel (address numbers 2 and 7) are the
dynamic control latches that are associated with enabling
dynamic functions within the device. Address numbers 3 and
4 are internal test registers.
Static Latch Values
There are some latches in the table that have a static value
(i.e. 1, 0, or X). The latches that have a ‘1’ or ‘0’ must be
configured with their corresponding value each time that their
associated latch bank is configured. The latches that have an
‘X’ are don’t cares and can be configured with any value.
Table 4. Device Configuration and Control Latch Descriptions
RXRATEA
Receive Clock Rate Select. The initialization value of the RXRATEA latch = 1. RXRATEA is used to
select the rate of the RXCLKA± clock output.
When RXRATEA = 1, the RXCLKA± clock outputs are complementary clocks that follow the recovered
clock operating at half the character rate. Data for the associated receive channels should be latched
alternately on the rising edge of RXCLKA+ and RXCLKA–.
When RXRATEA = 0, the RXCLKA± clock outputs are complementary clocks that follow the recovered
clock operating at the character rate. Data for the associated receive channels should be latched on the
rising edge of RXCLKA+ or falling edge of RXCLKA–.
SDASEL1A[1:0]
Primary Serial Data Input Signal Detector Amplitude Select. The initialization value of the
SDASEL1A[1:0] latch = 10. SDASEL1A[1:0] selects the trip point for the detection of a valid signal for
the INA1± Primary Differential Serial Data Inputs.
When SDASEL1A[1:0] = 00, the Analog Signal Detector is disabled.
When SDASEL1A[1:0] = 01, the typical p-p differential voltage threshold level is 140mV.
When SDASEL1A[1:0] = 10, the typical p-p differential voltage threshold level is 280mV.
When SDASEL1A[1:0] = 11, the typical p-p differential voltage threshold level is 420mV.
SDASEL2A[1:0]
Secondary Serial Data Input Signal Detector Amplitude Select. The initialization value of the
SDASEL2A[1:0] latch = 10. SDASEL2A[1:0] selects the trip point for the detection of a valid signal for
the INA2± Secondary Differential Serial Data Inputs.
When SDASEL2A[1:0] = 00, the Analog Signal Detector is disabled
When SDASEL2A[1:0] = 01, the typical p-p differential voltage threshold level is 140mV.
When SDASEL2A[1:0] = 10, the typical p-p differential voltage threshold level is 280mV.
When SDASEL2A[1:0] = 11, the typical p-p differential voltage threshold level is 420mV.
Document #: 38-02100 Rev. **
Page 14 of 28
PRELIMINARY
CYV15G0104TRB
Table 4. Device Configuration and Control Latch Descriptions (continued)
TRGRATEA
Training Clock Rate Select. The initialization value of the TRGRATEA latch = 0. TRGRATEA is used
to select the clock multiplier for the training clock input to the CDR PLL. When TRGRATEA = 0, the
TRGCLKA± input is not multiplied before it is passed to the CDR PLL. When TRGRATEA = 1, the
TRGCLKA± input is multiplied by 2 before it is passed to the CDR PLL. TRGRATEA = 1 and SPDSELA
= LOW is an invalid state and this combination is reserved.
RXPLLPDA
Receive Channel Enable. The initialization value of the RXPLLPDA latch = 0. RXPLLPDA selects if the
receive channel is enabled or powered-down. When RXPLLPDA = 0, the receive PLL and analog circuitry
are powered-down. When RXPLLPDA = 1, the receive PLL and analog circuitry are enabled.
RXBISTA[1:0]
Receive Bist Disable / SMPTE Receive Enable. The initialization value of the RXBISTA[1:0] latch =
11. For SMPTE data reception, RXBISTA[1:0] should not remain in this initialization state (11).
RXBISTA[1:0] selects if receive BIST is disabled or enabled and sets the device for SMPTE data
reception. When RXBISTA[1:0] = 01, the receiver BIST function is disabled and the device is set to
receive SMPTE data. When RXBISTA[1:0] = 10, the receive BIST function is enabled and the device is
set to receive BIST data. RXBISTA[1:0] = 00 and RXBISTA[1:0] = 11 are invalid states.
ROE2A
Reclocker Secondary Differential Serial Data Output Driver Enable. The initialization value of the
ROE2A latch = 0. ROE2A selects if the ROUTA2± secondary differential output drivers are enabled or
disabled. When ROE2A = 1, the associated serial data output driver is enabled allowing the reclocked
data to be transmitted. When ROE2A = 0, the associated serial data output driver is disabled. When a
driver is disabled via the configuration interface, it is internally powered down to reduce device power.
If both serial drivers for a channel are in this disabled state, the reclocker logic is also powered down.
A device reset (RESET sampled LOW) disables all output drivers.
ROE1A
Reclocker Primary Differential Serial Data Output Driver Enable. The initialization value of the
ROE1A latch = 0. ROE1A selects if the ROUTA1± primary differential output drivers are enabled or
disabled. When ROE1A = 1, the associated serial data output driver is enabled allowing the reclocked
data to be transmitted. When ROE1A = 0, the associated serial data output driver is disabled. When a
driver is disabled via the configuration interface, it is internally powered down to reduce device power.
If both serial drivers for a channel are in this disabled state, the reclocker logic is also powered down.
A device reset (RESET sampled LOW) disables all output drivers.
TXCKSELB
Transmit Clock Select. The initialization value of the TXCKSELB latch = 1. TXCKSELB selects the
clock source used to write data into the Transmit Input Register. When TXCKSELB = 1, the input register
TXDB[9:0] is clocked by REFCLKB↑. In this mode, the phase alignment buffer in the transmit path is
bypassed. When TXCKSELB = 0, TXCLKB↑ is used to clock in the input register TXDB[9:0].
TXRATEB
Transmit PLL Clock Rate Select. The initialization value of the TXRATEB latch = 0. TXRATEB is used
to select the clock multiplier for the Transmit PLL. When TXRATEB = 0, the transmit PLL multiples the
REFCLKB± input by 10 to generate the serial bit-rate clock. When TXRATEB = 0, the TXCLKOB output
clocks are full-rate clocks and follow the frequency and duty cycle of the REFCLKB± input. When
TXRATEB = 1, the Transmit PLL multiplies the REFCLKB± input by 20 to generate the serial bit-rate
clock. When TXRATEB = 1, the TXCLKOB output clocks are twice the frequency rate of the REFCLKB±
input. When TXCKSELB = 1 and TXRATEB = 1, the Transmit Data Inputs are captured using both the
rising and falling edges of REFCLKB. TXRATEB = 1 and SPDSELB = LOW, is an invalid state and this
combination is reserved.
TXBISTB
Transmit Bist Disable. The initialization value of the TXBISTB latch = 1. TXBISTB selects if the transmit
BIST is disabled or enabled. When TXBISTB = 1, the transmit BIST function is disabled. When
TXBISTB = 0, the transmit BIST function is enabled.
TOE2B
Secondary Differential Serial Data Output Driver Enable. The initialization value of the TOE2B latch
= 0. TOE2B selects if the TOUTB2± secondary differential output drivers are enabled or disabled. When
TOE2B = 1, the associated serial data output driver is enabled allowing data to be transmitted from the
transmit shifter. When TOE2B = 0, the associated serial data output driver is disabled. When a driver is
disabled via the configuration interface, it is internally powered down to reduce device power. If both
serial drivers for a channel are in this disabled state, the associated internal logic for that channel is also
powered down. A device reset (RESET sampled LOW) disables all output drivers.
TOE1B
Primary Differential Serial Data Output Driver Enable. The initialization value of the TOE1B latch =
0. TOE1B selects if the TOUTB1± primary differential output drivers are enabled or disabled. When
TOE1B = 1, the associated serial data output driver is enabled allowing data to be transmitted from the
transmit shifter. When TOE1B = 0, the associated serial data output driver is disabled. When a driver is
disabled via the configuration interface, it is internally powered down to reduce device power. If both
serial drivers for a channel are in this disabled state, the associated internal logic for that channel is also
powered down. A device reset (RESET sampled LOW) disables all output drivers.
Document #: 38-02100 Rev. **
Page 15 of 28
CYV15G0104TRB
PRELIMINARY
Table 4. Device Configuration and Control Latch Descriptions (continued)
PABRSTB
Transmit Clock Phase Alignment Buffer Reset. The initialization value of the PABRSTB latch = 1.
The PABRSTB is used to re-center the Transmit Phase Align Buffer. When the configuration latch
PABRSTB is written as a 0, the phase of the TXCLKB input clock relative to REFCLKB+/- is initialized.
PABRSTB is an asynchronous input, but is sampled by each TXCLKB↑ to synchronize it to the internal
clock domain. PABRSTB is a self clearing latch. This eliminates the requirement of writing a 1 to complete
the initialization of the Phase Alignment Buffer.
Device Configuration Strategy
3. Set the dynamic bank of latches for the target channel.
Enable the Receive PLL and/or transmit channel. If the
receiver is enabled, set the device for SMPTE data
reception (RXBISTA[1:0] = 01) or BIST data reception
(RXBISTA[1:0] = 10).
The following is a series of ordered events needed to load the
configuration latches on a per channel basis:
1. Pulse RESET Low after device power-up. This operation
resets both channels.
4. Reset the Phase Alignment Buffer. [Optional if phase align
buffer is bypassed.]
2. Set the static latch banks for the target channel.
Table 5. Device Control Latch Configuration Table
ADDR
Channel
Type
DATA6
DATA5
DATA4
DATA3
DATA2
DATA1
DATA0
Reset
Value
0
(000b)
A
S
1
0
X
X
0
0
RXRATEA
1011111
1
(001b)
A
S
SDASEL2A[1]
SDASEL2A[0]
SDASEL1A[1]
SDASEL1A[0]
X
X
TRGRATEA
1010110
2
(010b)
A
D
RXBISTA[1]
RXPLLPDA
RXBISTA[0]
X
ROE2A
ROE1A
X
1011001
3
(011b)
INTERNAL TEST REGISTERS
DO NOT WRITE TO THESE ADDRESSES
4
(100b)
5
(101b)
B
S
X
X
X
X
X
0
RXRATE D
1011111
6
(110b)
B
S
X
X
X
X
0
TXCKSELB
TXRATEB
1010110
7
(111b)
B
D
X
0
X
TXBISTB
TOE2B
TOE1B
PABRSTB
1011001
JTAG Support
3-Level Select Inputs
The CYV15G0104TRB contains a JTAG port to allow system
level diagnosis of device interconnect. Of the available JTAG
modes, boundary scan, and bypass are supported. This
capability is present only on the LVTTL inputs and outputs, the
TRGCLKA± input, and the REFCLKB± clock input. The highspeed serial inputs and outputs are not part of the JTAG test
chain.
Each 3-Level select inputs reports as two bits in the scan
register. These bits report the LOW, MID, and HIGH state of
the associated input as 00, 10, and 11 respectively
JTAG ID
The JTAG device ID for the CYV15G0104TRB is ‘0C811069’x.
Table 6. Receive BIST Status Bits
Description
Receive BIST Status
(Receive BIST = Enabled)
{BISTSTA, RXDA[0], RXDA[1]}
000, 001
010
BIST Data Compare. Character compared correctly.
BIST Last Good. Last Character of BIST sequence detected and valid.
011
Reserved.
100
BIST Last Bad. Last Character of BIST sequence detected invalid.
101
BIST Start. Receive BIST is enabled on this channel, but character compares have not yet
commenced. This also indicates a PLL Out of Lock condition.
110
BIST Error. While comparing characters, a mismatch was found in one or more of the
character bits.
111
BIST Wait. The receiver is comparing characters. but has not yet found the start of BIST
character to enable the LFSR.
Document #: 38-02100 Rev. **
Page 16 of 28
CYV15G0104TRB
PRELIMINARY
Monitor Data
Received
Receive BIST
Detected
LOW
{BISTSTA, RXDA[0],
RXDA[1]} =
BIST_START (101)
RX PLL
Out of Lock
{BISTSTA, RXDA[0], RXDA[1]} =
BIST_WAIT (111)
Start of
BIST Detected
No
Yes, {BISTSTA, RXDA[0], RXDA[1]} =
BIST_DATA_COMPARE (000, 001)
Compare
Next Character
Mismatch
Yes
Match
Auto-Abort
Condition
{BISTSTA, RXDA[0], RXDA[1]} =
BIST_DATA_COMPARE (000, 001)
No
End-of-BIST
State
End-of-BIST
State
Yes, {BISTSTA, RXDA[0], RXDA[1]} =
BIST_LAST_BAD (100)
Yes, {BISTSTA, RXDA[0], RXDA[1]} =
BIST_LAST_GOOD (010)
No
No, {BISTSTA, RXDA[0], RXDA[1]} =
BIST_ERROR (110)
Figure 2. Receive BIST State Machine
Document #: 38-02100 Rev. **
Page 17 of 28
CYV15G0104TRB
PRELIMINARY
Maximum Ratings
(Above which the useful life may be impaired. User guidelines
only, not tested.)
Static Discharge Voltage.......................................... > 2000 V
(per MIL-STD-883, Method 3015)
Latch-up Current..................................................... > 200 mA
Storage Temperature .................................. –65°C to +150°C
Power-up Requirements
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
The CYV15G0104TRB requires one power-supply. The
Voltage on any input or I/O pin cannot exceed the power pin
during power-up.
Supply Voltage to Ground Potential ............... –0.5V to +3.8V
Operating Range
DC Voltage Applied to LVTTL Outputs
in High-Z State .......................................–0.5V to VCC + 0.5V
Output Current into LVTTL Outputs (LOW)..................60 mA
DC Input Voltage....................................–0.5V to VCC + 0.5V
Range
Ambient Temperature
VCC
Commercial
0°C to +70°C
+3.3V ±5%
CYV15G0104TRB DC Electrical Characteristics
Parameter
Description
Test Conditions
Min.
Max.
Unit
LVTTL-compatible Outputs
VOHT
Output HIGH Voltage
IOH = − 4 mA, VCC = Min.
VOLT
Output LOW Voltage
IOL = 4 mA, VCC = Min.
IOST
Output Short Circuit Current
VOUT = 0V[8], VCC
IOZL
High-Z Output Leakage Current
VOUT = 0V, VCC
= 3.3V
2.4
V
0.4
V
–20
–100
mA
–20
20
µA
2.0
VCC + 0.3
V
–0.5
0.8
V
1.5
mA
LVTTL-compatible Inputs
VIHT
Input HIGH Voltage
VILT
Input LOW Voltage
IIHT
Input HIGH Current
Other Inputs, VIN = VCC
+40
µA
IILT
Input LOW Current
REFCLKB Input, VIN = 0.0V
–1.5
mA
Other Inputs, VIN = 0.0V
–40
µA
IIHPDT
Input HIGH Current with internal pull-down
VIN = VCC
+200
µA
IILPUT
Input LOW Current with internal pull-up
VIN = 0.0V
–200
µA
REFCLKB Input, VIN = VCC
LVDIFF Inputs: REFCLKB±
VDIFF[9]
Input Differential Voltage
400
VCC
mV
VIHHP
Highest Input HIGH Voltage
1.2
VCC
V
VILLP
Lowest Input LOW voltage
VCOMREF[10] Common Mode Range
0.0
VCC/2
V
1.0
VCC – 1.2V
V
3-Level Inputs
VIHH
Three-Level Input HIGH Voltage
Min. ≤ VCC ≤ Max.
0.87 * VCC
VCC
V
VIMM
Three-Level Input MID Voltage
Min. ≤ VCC ≤ Max.
0.47 * VCC
0.53 * VCC
V
VILL
Three-Level Input LOW Voltage
Min. ≤ VCC ≤ Max.
0.0
0.13 * VCC
V
200
µA
50
µA
–200
µA
IIHH
Input HIGH Current
VIN = VCC
IIMM
Input MID current
VIN = VCC/2
IILL
Input LOW current
VIN = GND
–50
Differential CML Serial Outputs: OUTA1±, OUTA2±, OUTB1±, OUTB2±, OUTC1±, OUTC2±, OUTD1±, OUTD2±
VOHC
Output HIGH Voltage
(Vcc Referenced)
100Ω differential load
VCC – 0.5
VCC – 0.2
V
150Ω differential load
VCC – 0.5
VCC – 0.2
V
8.
9.
Tested one output at a time, output shorted for less than one second, less than 10% duty cycle.
This is the minimum difference in voltage between the true and complement inputs required to ensure detection of a logic-1 or logic-0. A logic-1 exists when
the true (+) input is more positive than the complement (−) input. A logic-0 exists when the complement (−) input is more positive than true (+) input.
10. The common mode range defines the allowable range of REFCLKB+ and REFCLKB− when REFCLKB+ = REFCLKB−. This marks the zero-crossing between
the true and complement inputs as the signal switches between a logic-1 and a logic-0.
Document #: 38-02100 Rev. **
Page 18 of 28
CYV15G0104TRB
PRELIMINARY
CYV15G0104TRB DC Electrical Characteristics (continued)
Parameter
Description
Test Conditions
Min.
Max.
VCC – 0.7
Unit
VOLC
Output LOW Voltage
(VCC Referenced)
100Ω differential load
VCC – 1.4
V
150Ω differential load
VCC – 1.4
VCC – 0.7
V
VODIF
Output Differential Voltage
|(OUT+) − (OUT−)|
100Ω differential load
450
900
mV
150Ω differential load
560
1000
mV
100
1200
mV
VCC
V
1350
µA
Differential Serial Line Receiver Inputs: INA1±, INA2±
VDIFFs[9]
Input Differential Voltage |(IN+) − (IN−)|
VIHE
Highest Input HIGH Voltage
VILE
Lowest Input LOW Voltage
IIHE
Input HIGH Current
VCC – 2.0
IILE
Input LOW Current
VIN = VILE Min.
–700
VICOM[11]
Common Mode input range
((VCC – 2.0V)+0.5)min,
(VCC – 0.5V) max.
+1.25
+3.1
Typ.
Max.
Power Supply
ICC
[12,13]
ICC [12,13]
V
VIN = VIHE Max.
µA
V
Max Power Supply Current
REFCLKB
= MAX
Commercial
585
690
mA
Typical Power Supply Current
REFCLKB Commercial
= 125 MHz
560
660
mA
AC Test Loads and Waveforms
3.3V
RL = 100Ω
R1
R1 = 590Ω
R2 = 435Ω
CL
CL ≤ 7 pF
(Includes fixture and
probe capacitance)
(Includes fixture and
probe capacitance)
R2
(a) LVTTL Output Test Load
(b) CML Output Test Load
GND
2.0V
2.0V
0.8V
0.8V
Note 14
Note 14
3.0V
Vth = 1.4V
RL
VIHE
VIHE
Vth = 1.4V
≤ 1 ns
VILE
≤ 1 ns
(c) LVTTL Input Test Waveform
Note 15
80%
80%
20%
≤ 270 ps
20%
VILE
≤ 270 ps
(d) CML/LVPECL Input Test Waveform
CYV15G0104TRB AC Electrical Characteristics
Parameter
Description
Min.
Max
Unit
CYV15G0104TRB Transmitter LVTTL Switching Characteristics Over the Operating Range
fTS
TXCLKB Clock Cycle Frequency
19.5
150
MHz
tTXCLK
TXCLKB Period=1/fTS
6.66
51.28
ns
tTXCLKH[16]
TXCLKB HIGH Time
2.2
ns
tTXCLKL[16]
TXCLKB LOW Time
2.2
ns
Notes:
11. The common mode range defines the allowable range of INPUT+ and INPUT− when INPUT+ = INPUT−. This marks the zero-crossing between the true and
complement inputs as the signal switches between a logic-1 and a logic-0.
12. Maximum ICC is measured with VCC = MAX,TA = 25°C, with all channels and Serial Line Drivers enabled, sending a continuous alternating 01 pattern, and
outputs unloaded.
13. Typical ICC is measured under similar conditions except with VCC = 3.3V, TA = 25°C,with all channels enabled and one Serial Line Driver per channel sending
a continuous alternating 01 pattern. The redundant outputs on each channel are powered down and the parallel outputs are unloaded.
14. Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only.
15. The LVTTL switching threshold is 1.4V. All timing references are made relative to where the signal edges cross the threshold voltage.
16. Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.
Document #: 38-02100 Rev. **
Page 19 of 28
PRELIMINARY
CYV15G0104TRB
CYV15G0104TRB AC Electrical Characteristics (continued)
Min.
Max
Unit
tTXCLKR [16, 17, 18,
Parameter
TXCLKB Rise Time
0.2
1.7
ns
tTXCLKF [16, 17, 18,
TXCLKB Fall Time
0.2
1.7
ns
tTXDS
Transmit Data Set-up Time to TXCLKB↑ (TXCKSELB = 0)
2.2
tTXDH
Transmit Data Hold Time from TXCLKB↑ (TXCKSELB = 0)
0.8
fTOS
TXCLKOB Clock Frequency = 1x or 2x REFCLKB Frequency
19.5
150
MHz
tTXCLKO
TXCLKOB Period=1/fTOS
6.66
51.28
ns
tTXCLKOD
TXCLKOB Duty Cycle centered at 60% HIGH time
-1.9
0
ns
19]
19]
Description
ns
ns
CYV15G0104TRB Receiver LVTTL Switching Characteristics Over the Operating Range
fRS
RXCLKA± Clock Output Frequency
9.75
150
MHz
tRXCLKP
RXCLKA± Period = 1/fRS
6.66
102.56
ns
tRXCLKD
RXCLKA± Duty Cycle Centered at 50% (Full Rate and Half Rate)
–1.0
+1.0
ns
tRXCLKR
[16]
tRXCLKF [16]
tRXDv–
[20]
tRXDv+[20]
RXCLKA± Rise Time
0.3
1.2
ns
RXCLKA± Fall Time
0.3
1.2
ns
Status and Data Valid Time to RXCLKA± (RXRATEA = 0) (Full Rate)
5UI–1.8[21]
ns
Status and Data Valid Time to RXCLKA± (RXRATEA = 1) (Half Rate)
5UI–1.3[21]
ns
Status and Data Valid Time to RXCLKA± (RXRATEA = 0)
5UI–1.7[21]
ns
Status and Data Valid Time to RXCLKA± (RXRATEA = 1)
5UI–2.1[21]
ns
fROS
RECLKOA Clock Frequency
19.5
150
MHz
tRECLKO
RECLKOA Period=1/fROS
6.66
51.28
ns
tRECLKOD
RECLKOA Duty Cycle centered at 60% HIGH time
-1.9
0
ns
CYV15G0104TRB REFCLKB Switching Characteristics Over the Operating Range
fREF
REFCLKB Clock Frequency
19.5
150
MHz
tREFCLK
REFCLKB Period = 1/fREF
6.6
51.28
ns
tREFH
REFCLKB HIGH Time (TXRATEB = 1)(Half Rate)
5.9
ns
REFCLKB HIGH Time (TXRATEB = 0)(Full Rate)
2.9[16]
ns
REFCLKB LOW Time (TXRATEB = 1)(Half Rate)
5.9
ns
REFCLKB LOW Time (TXRATEB = 0)(Full Rate)
2.9[16]
ns
tREFL
tREFD
[22]
REFCLKB Duty Cycle
30
70
%
2
ns
2
ns
tREFR [16, 17, 18, 19]
REFCLKB Rise Time (20%–80%)
tREFF[16, 17, 18, 19]
REFCLKB Fall Time (20%–80%)
tTREFDS
Transmit Data Set-up Time to REFCLKB - Full Rate (TXRATEB = 0,
TXCKSELB = 1)
2.2
ns
Transmit Data Set-up Time to REFCLKB - Half Rate (TXRATEB = 1,
TXCKSELB = 1)
1.9
ns
Transmit Data Hold Time from REFCLKB - Full Rate (TXRATEB= 0,
TXCKSELB = 1)
0.8
ns
Transmit Data Hold Time from REFCLKB - Half Rate (TXRATEB = 1,
TXCKSELB = 1)
1.5
ns
tTREFDH
Notes:
17. The ratio of rise time to falling time must not vary by greater than 2:1.
18. For a given operating frequency, neither rise or fall specification can be greater than 20% of the clock-cycle period or the data sheet maximum time.
19. All transmit AC timing parameters measured with 1ns typical rise time and fall time.
20. Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.
21. Receiver UI (Unit Interval) is calculated as 1/(fTRG * 20) (when TRGRATEA = 1) or 1/(fTRG * 10) (when TRGRATEA = 0). In an operating link this is equivalent to tB.
22. The duty cycle specification is a simultaneous condition with the tREFH and tREFL parameters. This means that at faster character rates the REFCLKB± duty
cycle cannot be as large as 30%–70%.
Document #: 38-02100 Rev. **
Page 20 of 28
CYV15G0104TRB
PRELIMINARY
CYV15G0104TRB AC Electrical Characteristics (continued)
Parameter
Description
Min.
Max
Unit
CYV15G0104TRB TRGCLKA Switching Characteristics Over the Operating Range
fTRG
TRGCLKA Clock Frequency
19.5
150
MHz
tREFCLK
TRGCLKA Period = 1/fTRG
6.6
51.28
ns
tTRGH
TRGCLKA HIGH Time (TRGRATEA = 1)(Half Rate)
5.9
ns
TRGCLKA HIGH Time (TRGRATEA = 0)(Full Rate)
2.9[16]
ns
TRGCLKA LOW Time (TRGRATEA = 1)(Half Rate)
5.9
ns
TRGCLKA LOW Time (TRGRATEA = 0)(Full Rate)
2.9[16]
ns
tTRGL
tTRGD
[23]
TRGCLKA Duty Cycle
30
tTRGR [16, 17, 18]
TRGCLKA Rise Time (20%–80%)
tTRGF[16, 17, 18]
TRGCLKA Fall Time (20%–80%)
tTRGRX[24]
TRGCLKA Frequency Referenced to Received Clock Frequency
–0.15
70
%
2
ns
2
ns
+0.15
%
CYV15G0104TRB Bus Configuration Write Timing Characteristics Over the Operating Range
tDATAH
Bus Configuration Data Hold
0
ns
tDATAS
Bus Configuration Data Setup
10
ns
tWRENP
Bus Configuration WREN Pulse Width
10
ns
CYV15G0104TRB JTAG Test Clock Characteristics Over the Operating Range
fTCLK
JTAG Test Clock Frequency
tTCLK
JTAG Test Clock Period
20
MHz
50
ns
30
ns
CYV15G0104TRB Device RESET Characteristics Over the Operating Range
tRST
Device RESET Pulse Width
CYV15G0104TRB Transmitter and Reclocker Serial Output Characteristics Over the Operating Range
Parameter
Description
tB
Bit Time
tRISE[16]
CML Output Rise Time 20−80% (CML Test Load)
tFALL[16]
CML Output Fall Time 80−20% (CML Test Load)
Condition
SPDSELx =
HIGH
Min.
Max.
Unit
660
5128
ps
50
270
ps
SPDSELx= MID
100
500
ps
SPDSELx =LOW
180
1000
ps
SPDSELx =
HIGH
50
270
ps
SPDSELx = MID
100
500
ps
SPDSELx =LOW
180
1000
ps
PLL Characteristics
Parameter
Description
Condition
Min
.
Typ.
Max.
Unit
CYV15G0104TRB Transmitter Output PLL Characteristics
tJTGENSD[16, 25]
Transmit Jitter Generation - SD Data Rate
REFCLKB = 27 MHz
200
ps
tJTGENHD[16, 25]
Transmit Jitter Generation - HD Data Rate
REFCLKB = 148.5
MHz
76
ps
tTXLOCK
Transmit PLL lock to REFCLKB±
200
µs
Notes:
23. The duty cycle specification is a simultaneous condition with the tTRGH and tTRGL parameters. This means that at faster character rates the TRGCLKA± duty
cycle cannot be as large as 30%–70%.
24. TRGCLKA± has no phase or frequency relationship with the recovered clock(s) and only acts as a centering reference to reduce clock synchronization time.
TRGCLKA± must be within ±1500 PPM (±0.15%) of the transmitter PLL reference (REFCLK±) frequency. Although transmitting to a HOTLink II receiver channel
necessitates the frequency difference between the transmitter and receiver reference clocks to be within ±1500-PPM, the stability of the crystal needs to be
within the limits specified by the appropriate standard when transmitting to a remote receiver that is compliant to that standard.
25. While sending BIST data at the corresponding data rate, after 10,000 histogram hits, time referenced to REFCLKB± input.
26. Receiver input stream is BIST data from the transmit channel. This data is reclocked and output to a wide-bandwidth digital sampling oscilloscope. The
measurement was recorded after 10,000 histogram hits, time referenced to REFCLKB± of the transmit channel.
Document #: 38-02100 Rev. **
Page 21 of 28
CYV15G0104TRB
PRELIMINARY
PLL Characteristics
Parameter
Description
Condition
Min
.
Typ.
Max.
Unit
CYV15G0104TRB Reclocker Output PLL Characteristics
tJRGENSD[16, 26]
Reclocker Jitter Generation - SD Data Rate
TRGCLKA = 27 MHz
133
ps
tJRGENHD[16, 26]
Reclocker Jitter Generation - HD Data Rate
TRGCLKA = 148.5
MHz
107
ps
CYV15G0104TRB Receive PLL Characteristics Over the Operating Range
tRXLOCK
tRXUNLOCK
Receive PLL lock to input data stream (cold start)
376k
UI
Receive PLL lock to input data stream
376k
UI
46
UI
Receive PLL Unlock Rate
Capacitance [16]
Parameter
Description
Test Conditions
Max.
Unit
CINTTL
TTL Input Capacitance
TA = 25°C, f0 = 1 MHz, VCC = 3.3V
7
pF
CINPECL
PECL input Capacitance
TA = 25°C, f0 = 1 MHz, VCC = 3.3V
4
pF
CYV15G0104TRB HOTLink II Transmitter Switching Waveforms
Transmit Interface
Write Timing
TXCLKB selected
tTXCLK
tTXCLKH
tTXCLKL
TXCLKB
tTXDS
tTXDH
TXDB[9:0]
Transmit Interface
Write Timing
REFCLKB selected
TXRATEB = 0
tREFH
tREFCLK
tREFL
REFCLKB
tTREFDS
tTREFDH
TXDB[9:0]
Transmit Interface
Write Timing
REFCLKB selected
TXRATEB = 1
tREFCLK
tREFH
tREFL
REFCLKB
Note 27
tTREFDS
tTREFDH
tTREFDS
tTREFDH
TXDB[9:0]
Notes:
27. When REFCLKB± is configured for half-rate operation (TXRATEB = 1) and data is captured using REFCLKB instead of a TXCLKB clock. Data is captured using
both the rising and falling edges of REFCLKB.
Document #: 38-02100 Rev. **
Page 22 of 28
CYV15G0104TRB
PRELIMINARY
CYV15G0104TRB HOTLink II Transmitter Switching Waveforms (continued)
Transmit Interface
TXCLKOB Timing
tREFCLK
tREFH
TXRATE = 1
REFCLKB
tREFL
Note 28
tTXCLKO
Note 29
TXCLKOB
(internal)
Transmit Interface
TXCLKOB Timing
tREFCLK
tREFH
TXRATEB = 0
tREFL
Note28
REFCLKB
Note29
tTXCLKO
TXCLKOB
Switching Waveforms for the CYV15G0104TRB HOTLink II Receiver
Receive Interface
Read Timing
RXRATEA = 0
tRXCLKP
RXCLKA+
RXCLKA-
tRXDV–
RXDA[9:0]
tRXDV+
Notes:
28. The TXCLKOB output remains at the character rate regardless of the state of TXRATEB and does not follow the duty cycle of REFCLKB±.
29. The rising edge of TXCLKOB output has no direct phase relationship to the REFCLKB± input.
Document #: 38-02100 Rev. **
Page 23 of 28
CYV15G0104TRB
PRELIMINARY
Switching Waveforms for the CYV15G0104TRB HOTLink II Receiver
Receive Interface
Read Timing
RXRATEA = 1
tRXCLKP
RXCLKA+
RXCLKA-
tRXDV–
RXDA[9:0]
tRXDV+
Bus Configuration
Write Timing
ADDR[2:0]
DATA[6:0]
tWRENP
WREN
Document #: 38-02100 Rev. **
tDATAS
tDATAH
Page 24 of 28
CYV15G0104TRB
PRELIMINARY
Table 7. Package Coordinate Signal Allocation
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
A01
NC
NO CONNECT
A02
NC
NO CONNECT
C07
NC
NO CONNECT
F17
VCC
POWER
C08
GND
GROUND
F18
NC
NO CONNECT
A03
NC
A04
NC
NO CONNECT
C09
DATA[6]
LVTTL IN PU
F19
NC
NO CONNECT
NO CONNECT
C10
DATA[4]
LVTTL IN PU
F20
NC
NO CONNECT
A05
VCC
POWER
A06
NC
NO CONNECT
C11
DATA[2]
LVTTL IN PU
G01
GND
GROUND
C12
DATA[0]
LVTTL IN PU
G02
WREN
LVTTL IN PU
A07
TOUTB1–
CML OUT
C13
A08
GND
GROUND
C14
GND
GROUND
G03
GND
GROUND
NC
NO CONNECT
G04
GND
GROUND
Signal Type
A09
GND
GROUND
C15
SPDSELB
3-LEVEL SEL
G17
NC
NO CONNECT
A10
TOUTB2–
CML OUT
C16
VCC
POWER
G18
NC
NO CONNECT
A11
INA1–
CML IN
C17
LDTDEN
LVTTL IN PU
G19
SPDSELA
3-LEVEL SEL
A12
ROUTA1–
CML OUT
C18
TRST
LVTTL IN PU
G20
NC
NO CONNECT
A13
GND
GROUND
C19
GND
GROUND
H01
GND
GROUND
A14
INA2–
CML IN
C20
TDO
LVTTL 3-S OUT
H02
GND
GROUND
A15
ROUTA2–
CML OUT
D01
TCLK
LVTTL IN PD
H03
GND
GROUND
A16
VCC
POWER
D02
RESET
LVTTL IN PU
H04
GND
GROUND
A17
VCC
POWER
D03
VCC
POWER
H17
GND
GROUND
A18
NC
NO CONNECT
D04
INSELA
LVTTL IN
H18
GND
GROUND
A19
VCC
POWER
D05
VCC
POWER
H19
GND
GROUND
A20
NC
NO CONNECT
D06
ULCA
LVTTL IN PU
H20
GND
GROUND
B01
VCC
POWER
D07
NC
NO CONNECT
J01
GND
GROUND
B02
NC
NO CONNECT
D08
GND
GROUND
J02
GND
GROUND
B03
VCC
POWER
D09
DATA[5]
LVTTL IN PU
J03
GND
GROUND
B04
NC
NO CONNECT
D10
DATA[3]
LVTTL IN PU
J04
GND
GROUND
B05
VCC
POWER
D11
DATA[1]
LVTTL IN PU
J17
NC
NO CONNECT
B06
VCC
POWER
D12
GND
GROUND
J18
NC
NO CONNECT
B07
TOUTB1+
CML OUT
D13
GND
GROUND
J19
NC
NO CONNECT
B08
GND
GROUND
D14
GND
GROUND
J20
NC
NO CONNECT
B09
NC
NO CONNECT
D15
NC
NO CONNECT
K01
NC
NO CONNECT
B10
TOUTB2+
CML OUT
D16
VCC
POWER
K02
NC
NO CONNECT
B11
INA1+
CML IN
D17
NC
NO CONNECT
K03
GND
GROUND
B12
ROUTA1+
CML OUT
D18
VCC
POWER
K04
GND
GROUND
B13
GND
GROUND
D19
SCANEN2
LVTTL IN PD
K17
NC
NO CONNECT
B14
INA2+
CML IN
D20
TMEN3
LVTTL IN PD
K18
NC
NO CONNECT
B15
ROUTA2+
CML OUT
E01
VCC
POWER
K19
NC
NO CONNECT
B16
VCC
POWER
E02
VCC
POWER
K20
NC
NO CONNECT
B17
NC
NO CONNECT
E03
VCC
POWER
L01
NC
NO CONNECT
B18
NC
NO CONNECT
E04
VCC
POWER
L02
NC
NO CONNECT
B19
NC
NO CONNECT
E17
VCC
POWER
L03
NC
NO CONNECT
B20
NC
NO CONNECT
E18
VCC
POWER
L04
GND
GROUND
C01
TDI
LVTTL IN PU
E19
VCC
POWER
L17
NC
NO CONNECT
C02
TMS
LVTTL IN PU
E20
VCC
POWER
L18
NC
NO CONNECT
C03
VCC
POWER
F01
NC
NO CONNECT
L19
NC
NO CONNECT
Document #: 38-02100 Rev. **
Page 25 of 28
CYV15G0104TRB
PRELIMINARY
Table 7. Package Coordinate Signal Allocation (continued)
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
Signal Type
Ball
ID
Signal Name
Signal Type
C04
VCC
POWER
F02
NC
NO CONNECT
L20
GND
GROUND
C05
VCC
POWER
F03
VCC
POWER
M01
NC
NO CONNECT
C06
NC
NO CONNECT
F04
NC
NO CONNECT
M02
NC
NO CONNECT
M03
NC
NO CONNECT
U03
TXDB[2]
LVTTL IN
W03
NC
NO CONNECT
M04
NC
NO CONNECT
U04
TXDB[9]
LVTTL IN
W04
NC
NO CONNECT
M17
NC
NO CONNECT
U05
VCC
POWER
W05
VCC
POWER
M18
NC
NO CONNECT
U06
NC
NO CONNECT
W06
NC
NO CONNECT
M19
NC
NO CONNECT
U07
NC
NO CONNECT
W07
NC
NO CONNECT
M20
GND
GROUND
U08
GND
GROUND
W08
GND
GROUND
N01
GND
GROUND
U09
GND
GROUND
W09
ADDR [2]
LVTTL IN PU
N02
GND
GROUND
U10
ADDR [0]
LVTTL IN PU
W10
ADDR [1]
LVTTL IN PU
N03
GND
GROUND
U11
REFCLKB–
PECL IN
W11
RXCLKA+
LVTTL OUT
N04
GND
GROUND
U12
GND
GROUND
W12
REPDOA
LVTTL OUT
N17
GND
GROUND
U13
GND
GROUND
W13
GND
GROUND
N18
GND
GROUND
U14
GND
GROUND
W14
GND
GROUND
N19
GND
GROUND
U15
VCC
POWER
W15
VCC
POWER
N20
GND
GROUND
U16
VCC
POWER
W16
VCC
POWER
P01
NC
NO CONNECT
U17
RXDA[4]
LVTTL OUT
W17
LFIA
LVTTL OUT
P02
NC
NO CONNECT
U18
VCC
POWER
W18
TRGCLKA+
PECL IN
P03
NC
NO CONNECT
U19
BISTSTA
LVTTL OUT
W19
RXDA[6]
LVTTL OUT
P04
NC
NO CONNECT
U20
RXDA[0]
LVTTL OUT
W20
RXDA[3]
LVTTL OUT
P17
GND
GROUND
V01
TXDB[3]
LVTTL IN
Y01
TXDB[6]
LVTTL IN
P18
GND
GROUND
V02
TXDB[4]
LVTTL IN
Y02
TXCLKB
LVTTL IN PD
P19
GND
GROUND
V03
TXDB[8]
LVTTL IN
Y03
NC
NO CONNECT
P20
GND
GROUND
V04
NC
NO CONNECT
Y04
NC
NO CONNECT
R01
NC
NO CONNECT
V05
VCC
POWER
Y05
VCC
POWER
R02
NC
NO CONNECT
V06
NC
NO CONNECT
Y06
NC
NO CONNECT
R03
NC
NO CONNECT
V07
NC
NO CONNECT
Y07
NC
NO CONNECT
R04
NC
NO CONNECT
V08
GND
GROUND
Y08
GND
GROUND
R17
VCC
POWER
V09
NC
NO CONNECT
Y09
TXCLKOB
LVTTL OUT
R18
VCC
POWER
V10
GND
GROUND
Y10
NC
NO CONNECT
R19
VCC
POWER
V11
REFCLKB+
PECL IN
Y11
GND
GROUND
R20
VCC
POWER
V12
RECLKOA
LVTTL OUT
Y12
RXCLKA–
LVTTL OUT
T01
VCC
POWER
V13
GND
GROUND
Y13
GND
GROUND
T02
VCC
POWER
V14
GND
GROUND
Y14
GND
GROUND
T03
VCC
POWER
V15
VCC
POWER
Y15
VCC
POWER
T04
VCC
POWER
V16
VCC
POWER
Y16
VCC
POWER
T17
VCC
POWER
V17
RXDA[9]
LVTTL OUT
Y17
TXERRB
LVTTL OUT
T18
VCC
POWER
V18
RXDA[5]
LVTTL OUT
Y18
TRGCLKA–
PECL IN
T19
VCC
POWER
V19
RXDA[2]
LVTTL OUT
Y19
RXDA[8]
LVTTL OUT
T20
VCC
POWER
V20
RXDA[1]
LVTTL OUT
Y20
RXDA[7]
LVTTL OUT
U01
TXDB[0]
LVTTL IN
W01
TXDB[5]
LVTTL IN
U02
TXDB[1]
LVTTL IN
W02
TXDB[7]
LVTTL IN
Document #: 38-02100 Rev. **
Page 26 of 28
CYV15G0104TRB
PRELIMINARY
Ordering Information
Speed
Standard
Ordering Code
CYV15G0104TRB-BGC
Package Name
BL256
Package Type
256-Ball Thermally Enhanced Ball Grid Array
Operating
Range
Commercial
Package Diagram
256-Lead L2 Ball Grid Array (27 x 27 x 1.57 mm) BL256
51-85123-*E
HOTLink is a registered trademark and HOTLink II is a trademark of Cypress Semiconductor. All product and company names
mentioned in this document may be the trademarks of their respective holders.
Document #: 38-02100 Rev. **
Page 27 of 28
© Cypress Semiconductor Corporation, 2004. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress product. Nor does it convey or imply any license under patent or other rights. Cypress products are not warranted nor intended to be
used for medical, life support, life saving, critical control or safety applications, unless pursuant to an express written agreement with Cypress. Furthermore, Cypress does not authorize its
products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress against all charges.
PRELIMINARY
CYV15G0104TRB
Document History Page
Document Title: CYV15G0104TRB Independent Clock HOTLink II™ Serializer and Reclocking Deserializer
Document Number: XX-XXXXX
REV.
ECN NO.
ISSUE
DATE
**
Document #: 38-02100 Rev. **
ORIG. OF
CHANGE
FRE
DESCRIPTION OF CHANGE
New Data Sheet
Page 28 of 28