LPS-75 75W Single Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection PWM control and regulated Small and compact size Built-in remote ON-OFF control LED indicator for power on 100% full load burn-in test 2 years warranty SPECIFICATION MODEL LPS-75-3.3 LPS-75-5 LPS-75-12 LPS-75-15 LPS-75-24 LPS-75-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 15A 15A 6.2A 5A 3.2A 1.56A CURRENT RANGE 0 ~ 16.5A 0 ~ 16.5A 0 ~ 6.8A 0 ~ 5.5A 0 ~ 3.5A 0 ~ 1.7A RATED POWER 49.5W 75W 74.4W 75W 76.8W 75W 82.5W 81.6W 82.5W 84W 81.6W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 11 ~ 13.5V 13.5 ~ 16.5V PEAK LOAD(10sec.) OUTPUT Note.4 54.45W VOLTAGE TOLERANCE Note.3 INPUT 1.0% 1.0% LOAD REGULATION 3.0% 3.0% 2.0% 2.0% 1.0% 1.0% SETUP, RISE TIME 100ms, 35ms/230VAC HOLD UP TIME (Typ.) 60ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 100ms, 35ms/115VAC at full load 12ms/115VAC at full load 127 ~ 370VDC 77% 80% EFFICIENCY(Typ.) 69% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.9A/115VAC 1.1A/230VAC COLD START 18A/115VAC 36A/230VAC REMOTE ON/OFF WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE 81% 83% 83% 27.6 ~ 32.4V 57.6 ~ 67.2V <1mA / 240VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Hiccup mode, recovers automatically after fault condition is removed RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55011, EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF DIMENSION PACKING NOTE 2.0% 1.0% WORKING TEMP. OTHERS 2.0% 1.0% OVER VOLTAGE (Note 5) 2.0% 1.0% OVERLOAD EMC 45 ~ 54V 2.0% 1.0% PROTECTION SAFETY & 22 ~ 27V 3.0% LINE REGULATION LEAKAGE CURRENT FUNCTION 3 ~3.5V 3.0% Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 355Khrs min. MIL-HDBK-217F (25 ) 222*55*30mm (L*W*H) 0.3Kg; 48pcs/15.6Kg/1.12CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:LPS-75-SPEC 2008-03-25 LPS-75 75W Single Output Switching Power Supply Mechanical Specification series Unit:mm 222 212 1 CN3 2 CN1 3 45 55 5 1 SVR1 1 2 CN2 3 4 5 6 4- 3.8 2 max. 30 LED AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. 1 2,4 3 5 Assignment AC/L No Pin AC/N FG Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B6P-VH or equivalent Pin No. 1,2,3 4,5,6 Assignment -V +V Terminal JST SVH-21T-P1.1 or equivalent Mating Housing JST VHR or equivalent Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent Pin No. 1 2 Assignment RC+ RC- Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent Block Diagram fosc : 60KHz EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING O.L.P. PWM CONTROL RECTIFIERS & FILTER +V -V FG Derating Curve DETECTION CIRCUIT Static Characteristics (15V) 100 2 80 OUTPUT VOLTAGE (V) 1 3 1 Convection LOAD (%) 60 40 2 18CFM Forced Air 3 5V Only 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 300 18 250 15 200 12 150 9 100 6 50 3 25 80 90 100 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) Ta=25 21 260 INPUT VOLTAGE (V) 60Hz File Name:LPS-75-SPEC 2008-03-25