Embedded Power for Business-Critical Continuity Rev. 02.05.07 LPT25 Series 1 of 3 LPT25 Series RoHS 25 Watts Total Power: Input Voltage: # of Outputs: 25 - 40 Watts 85 - 264 VAC 120 - 300VDC Triple Electrical Specifications Special Features • • • • • • • • • • • • • Universal input 3" x 5" footprint Less than 1U high Remote sense on main output Terminal block option (-T) Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available 2 year warranty Safety VDE 0805 EN60950 11774-3336-1241 (LC#84936) UL UL60950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P95100411 (74-sec) 203 CB Certificate and report 1569, 1570, 1571, 1572 CE Mark (LVD) Input Input range Frequency Inrush current Input current Efficiency EMI Safety ground leakage current 85-264 VAC 120-300 VDC 47-440 Hz <15A peak @ 115VAC; <30A peak @ 230VAC, cold start @ 25°C 1 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC input Output Maximum Power Cross regulation Adjustment range Hold-up time Overload protection Overvoltage protection Remote sense 25W for convection; 40W with 30CFW forced air ±2% on output 1; ±5% on outputs 2, 3 -5, +10% minimum 20 ms @ 25 W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating 5.7 to 6.7 VDC on the main output Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 02.05.07 LPT25 Series 2 of 3 Environmental Specifications Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C, -20°C start up. Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Electromagnetic susceptibility: Humidity: Operating; non-condensing 5% to 95% Vibration: Storage temperature: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Ordering Information Model Number 0.3A 0.1A 0A Maximum Load with Convnection cooling 3A 1.5A 0.5A Maximum Load with 30CFM Forced Air 4A 2A 0.7A 0.4A 0A 0A 0.3A 0.1A 0A 0.3A 0.1A 0A 4A 0.5A 0.5A 3A 1.5A 0.5A 3A 1.5A 0.5A 5A 0.7A 0.7A 4A 2A 0.7A 4A 2A 0.7A Output Voltage Minimum Load LPT22(-T) 5V 12V -12V LPT23(-T) 5V 12V -12V 5V 12V -5V 5V 15V -15V LPT24(-T) LPT25(-T) Peak Load1 Regulation2 Ripple P/P (PARD)3 5A 3A 1A ±2% ±5% ±5% 50mV 120mV 120mV 6A 1A 1A 5A 3A 1A 5A 2A 1A ±2% ±5% ±5% ±2% ±5% ±5% ±2% ±5% ±5% 50mV 120mV 120mV 50mV 120mV 50mV 50mV 150mV 150mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. 5. (-T) indicates Terminal Block option for input and output (instead of Molex type). Power Derating Curve 40W 30 CFM Forced Air Cooling 30W Output Power 25W (Watts) 20W 10W Natural Convection Cooling 20W 12.5W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C Embedded Power for Business-Critical Continuity Astec Mechanical Drawing 0.22" (5.6) 4.55" (115.6) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 5.00" (127) M1 GND SK201 3.00" (76.2) SK 1 1 M2 _+ 1 2 3 4 5 6 2.55" (64.8) 3 Rev. 02.05.07 LPT25 Series 3 of 3 N Remote Sense Connector Voltage Adj. Pot SK 2 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 13-15, Shing Wan Road Tai Wai, Shatin, N. T. Hong Kong Telephone: +852 2699 2868 Facsimile: +852 2699 1770 L 0.15" (4) DIA (4 places) For global contact, visit: www.astecpower.com [email protected] While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 1.14" (29) 0.197" (5) Pin Assignments Mating Connectors Connector LPT22 LPT23 LPT24 LPT25 SK1-1 SK1-3 Line Neutral Line Neutral Line Neutral Line Neutral SK2-1 SK2- 2 SK2- 3 +12V +5 V +5 V +12V +5V +5V +12V +5V +5V +15V +5V +5V SK2-4 Common Common Common Common SK2-5 SK2-6 SK201-1 SK201-2 Common -12V +Sense -Sense Common -12V +Sense -Sense Common -5V +Sense -Sense Common -15V +Sense -Sense AC Input: Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK) PINS: 08-52-0113 DC Outputs: Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK) PINS: 08-52-0113 Remote Molex 22-01-2025 PINS: 08-52-0123 Sense: Astec Connector Kit #70-841-006, includes all of the above Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power 1. Specifications subject to change without notice. 2. 3. Inbound Power 6. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm) Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. Warranty: 2 year 7. Weight: 0.5lbs/0.23kg Site Monitoring and Services 4. 5. Integrated Cabinet Solutions Outside Plant Precision Cooling EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.