Mean Well HRP-75-36 75w single output with pfc function Datasheet

HRP-75
75W Single Output with PFC Function
series
Features :
Universal AC input / Full range
Built-in active PFC function
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Protections: Over temperature (optional)
Cooling by free air convection
1U low profile 38mm
Built-in remote ON-OFF control
No load power consumption<0.5W
All using 105 long life electrolytic capacitors
5 years warranty
SPECIFICATION
MODEL
OUTPUT
HRP-75-3.3
HRP-75-5
HRP-75-7.5
HRP-75-12
HRP-75-15
HRP-75-24
HRP-75-36
HRP-75-48
DC VOLTAGE
3.3V
5V
7.5V
12V
15V
24V
36V
48V
RATED CURRENT
15A
15A
10A
6.3A
5A
3.2A
2.1A
1.6A
CURRENT RANGE
0 ~ 15A
0 ~ 15A
0 ~ 10A
0 ~ 6.3A
0 ~ 5A
0 ~ 3.2A
0 ~ 2.1A
0 ~ 1.6A
RATED POWER
49.5W
75W
75W
75.6W
75W
76.8W
75.6W
76.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
100mVp-p
120mVp-p
150mVp-p
150mVp-p
200mVp-p
240mVp-p
VOLTAGE ADJ. RANGE
4.7 ~ 5.8V
2.5%
7.1 ~ 9V
2.5%
11 ~ 13.8V
1.5%
14.2 ~ 18V
1.5%
21.6 ~ 28.8V
1.5%
32 ~ 39.6V
1.5%
45 ~ 55.2V
1.5%
VOLTAGE TOLERANCE Note.3
3.1 ~ 3.8V
2.5%
LINE REGULATION
1.0%
1.0%
1.0%
0.3%
0.3%
0.2%
0.2%
0.2%
LOAD REGULATION
2.0%
2.0%
1.5%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
1800ms, 25ms/230VAC
HOLD UP TIME (Typ.)
50ms/230VAC
VOLTAGE RANGE
Note.5 85 ~ 264VAC
47 ~ 63Hz
FREQUENCY RANGE
INPUT
POWER FACTOR (Typ.)
PF>0.9/230VAC
EFFICIENCY (Typ.)
77%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.2A/115VAC
35A/115VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
PROTECTION OVER VOLTAGE
FUNCTION
1800ms, 25ms/115VAC at full load
20ms/115VAC at full load
120 ~ 370VDC
PF>0.95/115VAC at full load
82.5%
84%
87%
88%
88.5%
89%
89%
0.7A/230VAC
65A/230VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed
6 ~ 7V
9.4 ~ 10.9V
14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V
41.4 ~ 48.6V 57.6 ~ 67.2V
3.96 ~ 4.62V
Protection type : Shut down o/p voltage, re-power on to recover
85
5 for 3.3V~15V; 80
5 for 24V~48V (TSW1 : detect on heatsink of power transistor) (optional)
OVER TEMPERATURE (OPTIONAL)
Protection type : Shut down o/p voltage , recovers automatically after temperature goes down
RC+ / RC-: 0 ~ 0.8V = power on ; 4 ~ 10V = power off
REMOTE CONTROL
-20 ~ +70 (Refer to output load derating curve)
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
SAFETY &
EMC
(Note 4)
OTHERS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
HARMONIC CURRENT
EMS IMMUNITY
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 , EN61000-6-2 , heavy industry level, criteria A
MTBF
394.8K hrs min.
DIMENSION
129*98*38mm (L*W*H)
0.47Kg; 30pcs/ 15Kg/ 0.97CUFT
PACKING
NOTE
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
MIL-HDBK-217F (25
/ 70% RH
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:HRP-75-SPEC 2009-10-09
HRP-75
75W Single Output with PFC Function
Mechanical Specification
Case No.903D
series
Unit:mm
31
3.5
7
122.5
9.5
1
2
3L
=5
98
4
M
85.5
2-
33
8.2
3
5
1 2
SVR1
CN100
3 .5
4.5
73.5
Terminal Pin No. Assignment
129
6.5
Mating Housing
Terminal
JST XHP
or equivalent
JST SXH-001T
or equivalent
3L
=5
32
38
3.5
3-M
18
Assignment
RCRC+
3.5
12 max.
Remote ON/OFF (CN100) : JST B-XH or equivalent
Pin No.
1
2
120
28.5
Assignment
DC OUTPUT -V
DC OUTPUT +V
9.5
Pin No.
4
5
18.5
Assignment
AC/L
AC/N
FG
9
Pin No.
1
2
3
77
Block Diagram
ACTIVE
INRUSH
CURRENT
LIMITING
EMI
FILTER
I/P
RECTIFIERS
&
PFC
POWER
SWITCHING
O.T.P.
O.L.P.
RECTIFIERS
&
FILTER
DETECTION
CIRCUIT
FG
PFC
CONTROL
+V
-V
PWM
CONTROL
O.V.P.
RC+
REMOTE
CONTROL
Derating Curve
RC-
Output Derating VS Input Voltage
Ta = 25
100
100
90
80
80
70
LOAD(%)
LOAD (%)
60
40
30
20
-20
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70
(HORIZONTAL)
60
50
40
85
100
125
135
155
264
INPUT VOLTAGE (V) 60Hz
File Name:HRP-75-SPEC 2009-10-09