Series AMEC30-MAZ 30 Watt | AC-DC / DC-DC Converter FEATURES: • • • • 4000VAC I/O isolation Medical Switching power modules for PCB mounting Operating temperature: -40 to +85°C Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC AMEC30-3.3SMAZ AMEC30-5SMAZ AMEC30-12SMAZ AMEC30-15SMAZ AMEC30-24SMAZ Input Voltage (VAC/Hz) Input Voltage (VDC) 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 120-370 120-370 120-370 120-370 120-370 Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) 3.3 5 12 15 24 Models Dual output Model Energy star compliant RoHS compliant Low Ripple and Noise CE, cULus approvals CB Models Single output Model • • • • Output Voltage (V) Output Current max (A) Efficiency (%) 6 6 2.5 2 1.25 80 83 85 85 84 Output Current max (A) Efficiency (%) AMEC30-5DMAZ 90-264/47-440 120-370 ±5 ±3 81 AMEC30-12DMAZ 90-264/47-440 120-370 ±12 ±1.25 84 AMEC30-15DMAZ 90-264/47-440 120-370 ±15 ±1 83 AMEC30-24DMAZ 90-264/47-440 120-370 ±24 ±0.625 82 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Conditions Current Inrush current <2ms Leakage current External fuse Input dissipation Start-up time Output Specifications Parameters Voltage accuracy Line regulation Load regulation Cross regulation Maximum Capacitive load Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current Typical 115 VAC 230 VAC 115 VAC 230 VAC Recommended slow blow type No load; 115VAC No load; 264VAC 3.15 <0.5 <0.8 117 Conditions Typical (LL-HL) 0-100% load single 0-100% load dual st nd 25% load - 1 out, 100% load – 2 out Depending of the model 25% load Step 20MHz bandwidth 115VAC *Ripple & Noise measured with 0.1μF M/C and 1μF E/C www.aimtec.com F 052e R8.N Tel: +1 514 620 2722 1 of 4 ±2 ±0.5 ±1 ±2 ±5 470-23 000 ±2 50 29 0 Maximum 740 410 25 50 150 Units mA A µA A W ms Maximum Units % % % % µF % of Vout mV p-p ms % of Max Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEC30-MAZ 30 Watt | AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance General Specifications Parameters Switching frequency Over current protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L X H X W) MTBF Shock Vibration >1000 Conditions VAC MΩ Maximum 140 110 Metal Units KHz % % o C C o C % / oC o 100 -40 to +100 0.02 Free air convection Non condensing Converter operation Units 4000 47 110 Zener diode clamp Hiccup mode, indefinite Auto recovery -40 - +85 With derating above 55ºC Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Rated Typical Auto recovery Environment Approval Test Typical 3 sec 95 % RH 270 4.92 x 2.56 x 1.38 inch / 125.00 x 65.00 x 35.00 mm > 800 000 hrs (MIL-HDBK -217F, t=+25oC) g Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052e R8.N cULus, CE, CB Scheme Medical Electrical Equipment Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 EN55011, class B IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEC30-MAZ 30 Watt | AC-DC / DC-DC Converter Pin Out Specifications 1 2 3 4 5 6 Single AC Input (L) AC Input (N) +V Output -V Output N.C. N.C. Dimensions Dual AC Input (L) AC Input (N) +V Output Common Common -V Output 2.56 (65.00) 2.56 (65.00) 1 Mounting Holes (including DIN rail bracket) (M3) 2 AC Input Connector 4.90 (125.00) 0.81 (20.50) 1.28 (32.50) 0.88 (22.25) 2.10 (53.25) 68.63 (2.700) Pin 3 4 5 6 DC Output Connector Bottom View Top View Dimensions: inch (mm) Case Tolerance: ±0.05 (±1.30) 35.00 (1.38) Side View PCB Mounting Screw PCB Mounting Screw Mylar Film PCB Bracket Mounting Screw PCB Mylar Film 2.6 mm Max Customer Chassis www.aimtec.com F 052e R8.N Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEC30-MAZ 30 Watt | AC-DC / DC-DC Converter Optional DIN Rail Bracket Derating Free Air Convection 55º C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.N Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only