Schurter EF12.ABTWF150C0.1110.01 Iec appliance inlet c20 with filter, circuit breaker ta45 (recessed) Datasheet

EF12
Power Entry Modules with Line Filter
www.schurter.com/pg06
IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
Standard- or Medical-Filter
C20
70° C
Description
Characteristics
Approvals
References
- Panel Mount:
Screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter EF11
- All single elements are already wired
- Line switch non-illuminated
Illuminated version on request
Thermal overload protection
Optional with undervoltage- or remote trip release
- With EMC-shield
- Qualified for use in equipment according IEC/EN 60950
General Product Information
- VDE License Number: 40001520
- UL License Number: E72928
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
12 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz
12 - 20 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
Circuit Breakers
Line Switch
Line Filter
MTBF
EMC Products
C20 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 16 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601‑1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
EF12
Power Entry Modules with Line Filter
www.schurter.com/pg06
Dimensions
59.5 mm
37
2.8
76.2*
10.6
32.2
41.2
32.9
3.6
0.8
R
81±0.10
90 ±0.10
80.05
.5
R6
S
3.3
9.5
6.4
33.9 ±0.10
59.5
4.55 ±0.05
12.55
40.55
10.9
4.
7
R
5.5
79.2
12.2
40.55
90
101
R
3.
55
±0
.0
5
05
3.
R 2.8
5.3
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
12
Standard Version
2 x 0.8
100
2.2
1
16
Standard Version
2 x 0.6
100
2.2
1
20
Standard Version
2 x 0.3
100
2.2
1
12
Medical Version (M5)
2 x 0.8
100
-
1
16
Medical Version (M5)
2 x 0.6
100
-
1
20
Medical Version (M5)
2 x 0.3
100
-
1
Diagrams
Standard version
Medical version
1) Line
2) Load
1) Line
2) Load
Attenuation Loss
Standard version
12 A
- - - - differential mode _____ common mode
16 A
20 A
EMC Products
EF12
Power Entry Modules with Line Filter
www.schurter.com/pg06
Medical version (M5)
12 A
16 A
20 A
EMC Products
EF12
Power Entry Modules with Line Filter
www.schurter.com/pg06
EMC Products
EF12
Power Entry Modules with Line Filter
www.schurter.com/pg06
Packaging unit
16 Pcs
Accessories
Description
Assorted Covers
Rear Cover
0859.0109
Cord retaining kits
Cord retaining strain relief
Flat head, Z
0888.0021
Flat head, H
4700.0008
Mating Outlets/Connectors
Category / Description
Connector Overview complete
IEC Connector C19, Rewireable, Straight
0104
IEC Connector C19, Rewireable, Angled
1651
IEC Connector C19, Rewireable, Straight
1652
IEC Connector C19, Rewireable, Angled
4790
IEC Connector C19, Rewireable, Straight
4795
Connector further types to EF12
Power Cord Overview complete
Power Cord with IEC Connector C19, Straight
1654
Power Cord further types to EF12
Power Supply or Interconnection Cord Overview complete
Divers Power Supply and Interconnection Cords 16 A
Kabelverbindung/16 A
Power Supply or Interconnection Cord further types to EF12
EMC Products
EF12
Power Entry Modules with Line Filter
www.schurter.com/pg06
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
[ min ] [ sec ]
10'000
60
Type
TA45
Rated current
In <3 A
[ min ] [ sec ]
10'000
60
1 pole protected
2`000
30
20
500
TA4 5
Rated current
In ≥ 3 A... < 18 A
0
1 pole protected
0
2 pole protected
20
+23 °C
Ambient temp.
min ] [ sec ]
10'000
Type
2`000
30
2 pole protected
1`000
10
Tripping characteristics
In * 18 A
Tripping characteristics
In * 3… < 18 A
0
1`000
10
+23 °C
Ambient temp.
500
0
5
5
200
100
100
1
1 pole protected
2 pole protected
1`000
50
20
10
10
10
5
5
5
2
2
2
1
1
1
0,5
0,5
0,5
0,1
1,05 1,32
2
3
4
5
8
Multiple of rated current
0,3
0,2
0,1
1,05 1,32
10
[ x In ]
+23 °C
100
1
20
0,2
Ambient temp.
500
20
0,3
In ≥18 A
2`000
200
50
Tripping time
Tripping time
50
TA4 5
Rated current
5
200
Tripping time
1
Type
2
3
4
5
10
[ x In ]
Multiple of rated current
1)
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature,
use a correction factor from the table on the right side:
8
0,3
0,2
0,1
1,05 1,32
2
3
Multiple of rated current
4
5
8
10
[ x In ]
* Temperature must be measured at the rear of the breaker next to
the terminals after equipment operating temperature has been
reached.
Example
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+40 °C ambient temperature
1)
* Ambient temperature [°C]
–10
–5
0
+23
+30
+40
+55
Correction factor
0,89
0,91
0,92
1,00
1,03
1,08
1,16
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
Order code for EF12 (order example)
Type
EF12.
Please note that Schurter will establish an internal new part number
for logistical use in addition to the order code. The format of this internal part number is, for example EF12.xxxx.1110.01
Order code TA45
(2-pole rocker-switch
without accessories)
A B T W F 1 5 0 C 0 .
Application note
The rated current of the line filter must be equal or higher than the
rated current of the circuit-breaker
11 1 0. 0 1
Other versions on request
– Rocker switch illuminated
see table 1
Wiring
1 = wired
Protection class
0 = Class I, housing black
Panel mount
0 = Screw-on version
Terminals
1 = Quick connect terminals 6,3 x 0,8 mm
Line filter version
1 = standard
2 = medical
Line filter, rated current
1 = 20 A, 2 = 16 A, 3 = 12 A
The
specifications,
descriptions and illustrations indicated in this document are based on
EMC
Products
current information. All content is subject to modifications and amendments.
Similar pages