DP8573A
DP8573A Real Time Clock (RTC)
Literature Number: SNAS561
DP8573A Real Time Clock (RTC)
General Description
The DP8573A is intended for use in microprocessor based
systems where information is required for multi-tasking, data
logging or general time of day/date information. This device
is implemented in low voltage silicon gate microCMOS technology to provide low standby power in battery back-up environments. The circuit’s architecture is such that it looks
like a contiguous block of memory or I/O ports organized as
one block of 32 bytes. This includes the Control Registers,
the Clock Counters, the Alarm Compare RAM, and the Time
Save RAM.
Time and date are maintained from 1/100 of a second to
year and leap year in a BCD format, 12 or 24 hour modes.
Day of week and day of month counters are provided. Time
is controlled by an on-chip crystal oscillator requiring only
the addition of the 32.768 kHz crystal and two capacitors.
Power failure logic and control functions have been integrated on chip. This logic is used by the RTC to issue a power
fail interrupt, and lock out the mP interface. The time power
fails may be logged into RAM automatically when VBB l
VCC. Additionally, two supply pins are provided. When VBB
l VCC, internal circuitry will automatically switch from the
main supply to the battery supply.
The DP8573A’s interrupt structure provides three basic
types of interrupts: Periodic, Alarm/Compare, and Power
Fail. Interrupt mask and status registers enable the masking
and easy determination of each interrupt.
Features
Y
Y
Y
Full function real time clock/calendar
Ð 12/24 hour mode timekeeping
Ð Day of week counter
Ð Parallel resonant oscillator
Power fail features
Ð Internal power supply switch to external battery
Ð Power Supply Bus glitch protection
Ð Automatic log of time into RAM at power failure
On-chip interrupt structure
Ð Periodic, alarm, and power fail interrupts
Block Diagram
TL/F/9981 – 1
FIGURE 1
TRI-STATEÉ is a registered trademark of National Semiconductor Corporation.
C1995 National Semiconductor Corporation
TL/F/9981
RRD-B30M75/Printed in U. S. A.
DP8573A Real Time Clock (RTC)
May 1993
Absolute Maximum Ratings (Notes 1 & 2)
Operation Conditions
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Supply Voltage (VCC) (Note 3)
Supply Voltage (VBB) (Note 3)
DC Input or Output Voltage
(VIN, VOUT)
Operation Temperature (TA)
Electr-Static Discharge Rating
Transistor Count
Typical Values
iJA DIP
Board
Socket
b 0.5V to a 7.0V
Supply Voltage (VCC)
b 0.5V to VCC a 0.5V
DC Input Voltage (VIN)
b 0.5V to VCC a 0.5V
DC Output Voltage (VOUT)
b 65§ C to a 150§ C
Storage Temperature Range
Power Dissipation (PD)
500 mW
Lead Temperature (Soldering, 10 sec.)
260§ C
iJA PLCC
Board
Socket
Min
4.5
2.2
Max
5.5
VCCb0.4
Unit
V
V
0.0
VCC
V
b 40
a 85
§C
kV
1
10,300
59§ C/W
65§ C/W
80§ C/W
88§ C/W
DC Electrical Characteristics
VCC e 5V g 10%, VBB e 3V, VPFAIL l VIH, CL e 100 pF (unless otherwise specified)
Symbol
Parameter
Conditions
Min
2.0
VBB b0.1
Max
Units
VIH
High Level Input Voltage
(Note 4)
Any Inputs Except OSC IN,
OSC IN with External Clock
VIL
Low Level Input Voltage
All Inputs Except OSC IN
OSC IN with External Clock
VOH
High Level Output Voltage
(Excluding OSC OUT)
IOUT e b20 mA
IOUT e b4.0 mA
VOL
Low Level Output Voltage
(Excluding OSC OUT)
IOUT e 20 mA
IOUT e 4.0 mA
0.1
0.25
V
V
IIN
Input Current (Except OSC IN)
VIN e VCC or GND
g 1.0
mA
IOZ
Output TRI-STATEÉ Current
VOUT e VCC or GND
g 5.0
mA
Output High Leakage Current
T1, MFO, INTR Pins
VOUT e VCC or GND
g 5.0
mA
Quiescent Supply Current
(Note 6)
FOSC e 32.768 kHz
VIN e VCC or GND (Note 5)
VIN e VCC or GND (Note 6)
VIN e VIH or VIL (Note 6)
250
1.0
12.0
mA
mA
mA
Quiescent Supply Current
(Single Supply Mode)
(Note 7)
VBB e GND
VIN e VCC or GND
FOSC e 32.768 kHz
40
mA
Standby Mode Battery
Supply Current
(Note 7)
VCC e GND
OSC OUT e open circuit,
other pins e GND
FOSC e 32.768 kHz
10
mA
Battery Leakage
2.2V s VBB s 4.0V
other pins at GND
VCC e GND
VCC e 5.5V
1.5
mA
mA
ILKG
ICC
ICC
IBB
IBLK
V
V
0.8
0.1
VCC b0.1
3.5
Outputs Open Drain
V
V
b5
Note 1: Absolute Maximum Ratings are those values beyond which damage to the device may occur.
Note 2: Unless otherwise specified all voltages are referenced to ground.
Note 3: In battery backed mode, VBB s VCC b 0.4V.
Single Supply Mode: Data retention voltage is 2.2V min.
In single Supply Mode (Power connected to VCC pin) 4.5V s VCC s 5.5V.
Note 4: This parameter (VIH) is not tested on all pins at the same time.
Note 5: This specification tests ICC with all power fail circuitry disabled, by setting D7 of Interrupt Control Register 1 to 0.
Note 6: This specification tests ICC with all power fail circuitry enabled, by setting D7 of Interrupt Control Register 1 to 1.
Note 7: OSC IN is driven by a signal generator. Contents of the Test Register e 00(H) and the MFO pin is not configured as buffered oscillator out.
2
V
V
AC Electrical Characteristics
VCC e 5V g 10%, VBB e 3V, VPFAIL l VIH, CL e 100 pF (unless otherwise specified)
Symbol
Parameter
Min
Max
Units
READ TIMING
tAR
Address Valid Prior to Read Strobe
20
ns
tRW
Read Strobe Width (Note 8)
80
ns
tCD
Chip Select to Data Valid Time
tRAH
Address Hold after Read (Note 9)
tRD
Read Strobe to Valid Data
tDZ
Read or Chip Select to TRI-STATE
tRCH
Chip Select Hold after Read Strobe
0
ns
tDS
Minimum Inactive Time between Read or Write Accesses
50
ns
tAW
Address Valid before Write Strobe
20
ns
tWAH
Address Hold after Write Strobe (Note 9)
3
ns
tCW
Chip Select to End of Write Strobe
90
ns
tWW
Write Strobe Width (Note 10)
80
ns
tDW
Data Valid to End of Write Strobe
50
ns
tWDH
Data Hold after Write Strobe (Note 9)
3
ns
tWCH
Chip Select Hold after Write Strobe
0
ns
80
ns
70
ns
60
ns
3
ns
WRITE TIMING
INTERRUPT TIMING
tROLL
Clock rollover to INTR out typically 16.5 ms
Note 8: Read Strobe width as used in the read timing table is defined as the period when both chip select and read inputs are low. Hence read commences when
both signals are low and terminates when either signal returns high.
Note 9: Hold time is guaranteed by design but not production tested. This limit is not used to calculate outgoing quality levels.
Note 10: Write Strobe width as used in the write timing table is defined as the period when both chip select and write inputs are low. Hence write commences when
both signals are low and terminates when either signal returns high.
AC Test Conditions
Input Pulse Levels
Input Rise and Fall Times
Input and Output
Reference Levels
TRI-STATE Reference
Levels (Note 12)
GND to 3.0V
6 ns (10%–90%)
1.3V
Active High a 0.5V
Active Low b0.5V
Note 11: CL e 100 pF, includes jig and scope capacitance.
Note 12: S1 e VCC for active low to high impedance measurements.
S1 e GND for active high to high impedance measurements.
S1 e open for all other timing measurements.
Capacitance (TA e 25§ C, f e 1 MHz)
Symbol
Parameter
(Note 14)
TL/F/9981 – 2
Typ
Units
CIN
Input Capacitance
5
pF
COUT
Output Capacitance
7
pF
Note 13: This parameter is not 100% tested.
Note 14: Output rise and fall times 25 ns max (10%–90%) with 100 pF load.
3
Timing Waveforms
Read Timing Diagram
TL/F/9981 – 3
Write Timing Diagram
TL/F/9981 – 4
Pin Description
battery backed mode and a pull-up resistor is attached, it
should be connected to a voltage no greater than VBB. The
output is a DC voltage level. To clear the INTR, write a 1 to
the appropriate bit(s) in the Main Status Register.
D0 – D7 (Input/Output): These 8 bidirectional pins connect
to the host mP’s data bus and are used to read from and
write to the RTC. When the PFAIL pin goes low and a write
is not in progress, these pins are at TRI-STATE.
PFAIL (Input): In battery backed mode, this pin can have a
digital signal applied to it via some external power detection
logic. When PFAIL e logic 0 the RTC goes into a lockout
mode, in a minimum of 30 ms or a maximum of 63 ms unless
lockout delay is programmed. In the single power supply
mode, this pin is not useable as an input and should be tied
to VCC. Refer to section on Power Fail Functional Description.
VBB (Battery Power Pin): This pin is connected to a backup power supply. This power supply is switched to the internal circuitry when the VCC becomes lower than VBB. Utilizing this pin eliminates the need for external logic to switch in
and out the back-up power supply. If this feature is not to be
used then this pin must be tied to ground, the RTC programmed for single power supply only, and power applied to
the VCC pin.
VCC: This is the main system power pin.
GND: This is the common ground power pin for both VBB
and VCC.
CS, RD, WR (Inputs): These pins interface to mP control
lines. The CS pin is an active low enable for the read and
write operations. Read and Write pins are also active low
and enable reading or writing to the RTC. All three pins are
disabled when power failure is detected. However, if a read
or write is in progress at this time, it will be allowed to complete its cycle.
A0 – A4 (Inputs): These 5 pins are for register selection.
They individually control which location is to be accessed.
These inputs are disabled when power failure is detected.
OSC IN (Input): OSC OUT (Output): These two pins are
used to connect the crystal to the internal parallel resonant
oscillator. The oscillator is always running when power is
applied to VBB and VCC.
MFO (Output): The multi-function output can be used as a
second interrupt (Power fail) output for interrupting the mP.
This pin can also provide an output for the oscillator. The
MFO output is configured as push-pull, active high for normal or single power supply operation and as an open drain
during standby mode (VBB l VCC). If in battery backed
mode and a pull-up resistor is attached, it should be connected to a voltage no greater than VBB.
INTR (Output): The interrupt output is used to interrupt the
processor when a timing event or power fail has occurred
and the respective interrupt has been enabled. The INTR
output is permanently configured active low, open drain. If in
4
Connection Diagrams
Plastic Chip Carrier
Dual-In-Line
TL/F/9981 – 5
TL/F/9981 – 6
Top View
Top View
Order Number DP8573AN
See NS Package Number N24C
Order Number DP8573AV
See NS Package Number V28A
Functional Description
The DP8573A contains a fast access real time clock, interrupt control logic, and power fail detect logic. All functions of
the RTC are controlled by a set of seven registers. A simplified block diagram that shows the major functional blocks is
given in Figure 1 .
The blocks are described in the following sections:
1. Real Time Clock
2. Oscillator Prescaler
3. Interrupt Logic
4. Power Failure Logic
5. Additional Supply Management
The memory map of the RTC is shown in the memory addressing table (Figure 2). A control bit in the Main Status
Register is used to select either control register block.
INITIAL POWER-ON of BOTH VBB and VCC
VBB and VCC may be applied in any sequence. In order for
the power fail circuitry to function correctly, whenever power
is off, the VCC pin must see a path to ground through a
maximum of 1 MX. The user should be aware that the control registers will contain random data. The user should ensure that the RTC is not in test mode (see register descriptions).
REAL TIME CLOCK FUNCTIONAL DESCRIPTION
As shown in Figure 2 , the clock has 8 bytes of counters,
which count from 1/100 of a second to years. Each counter
counts in BCD and is synchronously clocked. The count sequence of the individual byte counters within the clock is
shown later in Table VII. Note that the day of week, day of
month, and month counters all roll over to 1. The hours
counter in 12 hour mode rolls over to 1 and the AM/PM bit
toggles when the hours rolls over to 12 (AM e 0, PM e 1).
The AM/PM bit is bit D7 in the hours counter.
All other counters roll over to 0. Upon initial application of
power the counters will contain random information.
TL/F/9981 – 7
FIGURE 2. DP8573A Internal Memory Map
5
Functional Description (Continued)
The above method is useful when the entire clock is being
corrected. If one location is being updated the clock need
not be stopped since this will reset the prescaler, and time
will be lost. An ideal example of this is correcting the hours
for daylight savings time. To write to the clock ‘‘on the fly’’
the best method is to wait for the 1/100 of a second periodic interrupt. Then wait an additional 16 ms, and then write
the data to the clock.
READING THE CLOCK: VALIDATED READ
Since clocking of the counter occurs asynchronously to
reading of the counter, it is possible to read the counter
while it is being incremented (rollover). This may result in an
incorrect time reading. Thus to ensure a correct reading of
the entire contents of the clock (or that part of interest), it
must be read without a clock rollover occurring. In general
this can be done by checking a rollover bit. On this chip the
periodic interrupt status bits can serve this function. The
following program steps can be used to accomplish this.
1. Initialize program for reading clock.
2. Dummy read of periodic status bit to clear it.
3. Read counter bytes and store.
4. Read rollover bit, and test it.
5. If rollover occured go to 3.
6. If no rollover, done.
To detect the rollover, individual periodic status bits can be
polled. The periodic bit chosen should be equal to the highest frequency counter register to be read. That is if only
SECONDS through HOURS counters are read, then the
SECONDS periodic bit should be used.
PRESCALER/OSCILLATOR FUNCTIONAL
DESCRIPTION
Feeding the counter chain is a programmable prescaler
which divides the crystal oscillator frequency to 32 kHz and
further to 100 Hz for the counter chain (see Figure 3 ).
TL/F/9981 – 8
FIGURE 3. Programmable Clock Prescaler Block
In addition to the inverter, the oscillator feedback bias resistor is included on chip, as shown in Figure 4 . The oscillator
input may be driven from an external source if desired. Refer to test mode application note for details. The oscillator
stability is enhanced through the use of an on chip regulated
power supply.
The typical range of trimmer capacitor (as shown in Oscillator Circuit Diagram Figure 4 , and in the typical application) at
the oscillator input pin is suggested only to allow accurate
tuning of the oscillator. This range is based on a typical
printed circuit board layout and may have to be changed
depending on the parasitic capacitance of the printed circuit
board or fixture being used. In all cases, the load capacitance specified by the crystal manufacturer (nominal value
11 pF for the 32.768 crystal) is what determines proper oscillation. This load capcitance is the series combination of
capacitance on each side of the crystal (with respect to
ground).
READING THE CLOCK: INTERRUPT DRIVEN
Enabling the periodic interrupt mask bits cause interrupts
just as the clock rolls over. Enabling the desired update rate
and providing an interrupt service routine that executes in
less than 10 ms enables clock reading without checking for
a rollover.
READING THE CLOCK: LATCHED READ
Another method to read the clock that does not require
checking the rollover bit is to write a one into the Time Save
Enable bit (D7) of the Time Save Control Register, and then
to write a zero. Writing a one into this bit will enable the
clock contents to be duplicated in the Time Save RAM.
Changing the bit from a one to a zero will freeze and store
the contents of the clock in Time Save RAM. The time then
can be read without concern for clock rollover, since internal logic takes care of synchronization of the clock. Because only the bits used by the clock counters will be
latched, the Time Save RAM should be cleared prior to use
to ensure that random data stored in the unused bits do not
confuse the host microprocessor. This bit can also provide
time save at power failure, see the Additional Supply Management Functions section. With the Time Save Enable bit
at a logical 0, the Time Save RAM may be used as RAM if
the latched read function is not necessary.
INITIALIZING AND WRITING TO THE
CALENDAR-CLOCK
Upon initial application of power to the TCP or when making
time corrections, the time must be written into the clock. To
correctly write the time to the counters, the clock would
normally be stopped by writing the Start/Stop bit in the Real
Time Mode Register to a zero. This stops the clock from
counting and disables the carry circuitry. When initializing
the clock’s Real Time Mode Register, it is recommended
that first the various mode bits be written while maintaining
the Start/Stop bit reset, and then writing to the register a
second time with the Start/Stop bit set.
TL/F/9981 – 9
FIGURE 4. Oscillator Circuit Diagram
6
Functional Description (Continued)
XTAL
Co
Ct
ROUT
32.768 kHz
47 pF
2 pF–22 pF
150 kX to 350 kX
3. The Power Fail Interrupt: Issued upon recognition of a
power fail condition by the internal sensing logic. The
power failed condition is determined by the signal on the
PFAIL pin. The internal power fail signal is gated with the
chip select signal to ensure that the power fail interrupt
does not lock the chip out during a read or write.
INTERRUPT LOGIC FUNCTIONAL DESCRIPTION
The RTC has the ability to coordinate processor timing activities. To enhance this, an interrupt structure has been implemented which enables several types of events to cause
interrupts. Interrupts are controlled via two Control Registers in block 1 and two Status Registers in block 0. (See
Register Description for notes on paging and Table I.)
The interrupts are enabled by writing a one to the appropriate bits in Interrupt Control Register 0 and/or 1.
ALARM COMPARE INTERRUPT DESCRIPTON
The alarm/time comparison interrupt is a special interrupt
similar to an alarm clock wake up buzzer. This interrupt is
generated when the clock time is equal to a value programmed into the alarm compare registers. Up to six bytes
can be enabled to perform alarm time comparisons on the
counter chain. These six bytes, or some subset thereof,
would be loaded with the future time at which the interrupt
will occur. Next, the appropriate bits in the Interrupt Control
Register 1 are enabled or disabled (refer to detailed description of Interrupt Control Register 1). The RTC then compares these bytes with the clock time. When all the enabled
compare registers equal the clock time an alarm interrupt is
issued, but only if the alarm compare interrupt is enabled
can the interrupt be generated externally. Each alarm compare bit in the Control Register will enable a specific byte for
comparison to the clock. Disabling a compare byte is the
same as setting its associated counter comparator to an
‘‘always equal’’ state. For example, to generate an interrupt
at 3:15 AM of every day, load the hours compare with 0 3
(BCD), the minutes compare with 1 5 (BCD) and the faster
counters with 0 0 (BCD), and then disable all other compare
registers. So every day when the time rolls over from
3:14:59.99, an interrupt is issued. This bit may be reset by
writing a one to bit D3 in the Main Status Register at any
time after the alarm has been generated.
If time comparison for an individual byte counter is disabled,
that corresponding RAM location can then be used as general purpose storage.
TABLE I. Registers that are Applicable
to Interrupt Control
Register Name
Register
Select
Address
Main Status Register
Periodic Flag Register
Interrupt Control Register 0
Interrupt Control Register 1
Output Mode Register
X
0
1
1
1
00H
03H
03H
04H
02H
The Interrupt Status Flag D0, in the Main Status Register,
indicates the state of INTR and MFO outputs. It is set when
either output becomes active and is cleared when all RTC
interrupts have been cleared and no further interrupts are
pending (i.e., both INTR and MFO are returned to their inactive state). This flag enables the RTC to be rapidly polled by
the mP to determine the source of an interrupt in a wiredÐ
OR interrupt system. (The Interrupt Status Flag provides a
true reflection of all conditions routed to the external pins.)
Status for the interrupts are provided by the Main Status
Register and the Periodic Flag Register. Bits D1–D5 of the
Main Status Register are the main interrupt bits.
These register bits will be set when their associated timing
events occur. Enabled Alarm comparisons that occur will
set its Main Status Register bit to a one. However, an external interrupt will only be generated if the Alarm interrupt
enable bit is set (see Figure 5 ).
Disabling the periodic interrupts will mask the Main Status
Register periodic bit, but not the Periodic Flag Register bits.
The Power Fail Interrupt bit is set when the interrupt is enabled and a power fail event has occurred, and is not reset
until the power is restored. If all interrupt enable bits are 0
no interrupt will be asserted. However, status still can be
read from the Main Status Register in a polled fashion (see
Figure 5 ).
To clear a flag in bits D2 and D3 of the Main Status Register
a 1 must be written back into the bit location that is to be
cleared. For the Periodic Flag Register reading the status
will reset all the periodic flags.
Interrupts Fall Into Three Categories:
1. The Alarm Compare Interrupt: Issued when the value in
the time compared RAM equals the counter.
2. The Periodic Interrupts: These are issued at every increment of the specific clock counter signal. Thus, an interrupt is issued every minute, second, etc. Each of these
interrupts occurs at the roll-over of the specific counter.
PERIODIC INTERRUPTS DESCRIPTION
The Periodic Flag Register contains six flags which are set
by real-time generated ‘‘ticks’’ at various time intervals, see
Figure 5 . These flags constantly sense the periodic signals
and may be used whether or not interrupts are enabled.
These flags are cleared by any read or write operation performed on this register.
To generate periodic interrupts at the desired rate, the associated Periodic Interrupt Enable bit in Interrupt Control Register 0 must be set. Any combination of periodic interrupts
may be enabled to operate simultaneously. Enabled periodic interrupts will now affect the Periodic Interrupt Flag in the
Main Status Register.
When a periodic event occurs, the Periodic Interrupt Flag in
the Main Status Register is set, causing an interrupt to be
generated. The mP clears both flag and interrupt by writing a
‘‘1’’ to the Periodic Interrupt Flag. The individual flags in the
periodic Interrupt Flag Register do not require clearing to
cancel the interrupt.
If all periodic interrupts are disabled and a periodic interrupt
is left pending (i.e., the Periodic Interrupt Flag is still set), the
Periodic Interrupt Flag will still be required to be cleared to
cancel the pending interrupt.
7
FIGURE 5. Interrupt Control Logic Overview
TL/F/9981 – 10
Functional Description (Continued)
8
Functional Description (Continued)
disconnected, and the device is now in the standby mode. If
indeterminate operation of the battery switch over circuit is
to be avoided, then the voltage at the VCC pin must not be
allowed to equal the voltage at the VBB pin.
After the generation of a lock-out signal, and eventual
switch in of the battery supply, the pins of the RTC will be
configured as shown in Table II. Outputs that have a pull-up
resistor should be connected to a voltage no greater than
VBB.
POWER FAIL INTERRUPTS DESCRIPTION
The Power Fail Status Flag in the Main Status Register
monitors the state of the internal power fail signal. This flag
may be interrogated by the mP, but it cannot be cleared; it is
cleared automatically by the RTC when system power is
restored. To generate an interrupt when the power fails, the
Power Fail Interrupt Enable bit in Interrupt Control Register
1 is set. Although this interrupt may not be cleared, it may
be masked by clearing the Power Fail Interrupt Enable bit.
POWER FAILURE CIRCUITRY FUNCTIONAL
DESCRIPTION
Since the clock must be operated from a battery when the
main system supply has been turned off, the DP8573A provides circuitry to simplify design in battery backed systems.
This switches over to the back up supply, and isolates itself
from the host system. Figure 6 shows a simplified block
diagram of this circuitry, which consists of three major sections; 1) power loss logic: 2) battery switch over logic: and 3)
isolation logic.
Detection of power loss occurs when PFAIL is low. Debounce logic provides a 30 ms – 63 ms debounce time, which
will prevent noise on the PFAIL pin from being interpreted
as a system failure. After 30 ms – 63 ms the debounce logic
times out and a signal is generated indicating that system
power is marginal and is failing. The Power Fail Interrupt will
then be generated.
If chip select is low when a power failure is detected, a
safety circuit will ensure that if a read or write is held active
continuously for greater than 30 ms after the power fail signal is asserted, the lock-out will be forced.
The battery switch over circuitry is completely independent
of the PFAIL pin. A separate circuit compares VCC to the
VBB voltage. As the main supply fails, the RTC will continue
to operate from the VCC pin until VCC falls below the VBB
voltage. At this time, the battery supply is switched in, VCC is
TABLE II. Pin Isolation during a Power Failure
Pin
PFAIL e
Logic 0
CS, RD, WR
A0 – A4
D0 – D7
Oscillator
PFAIL
INTR, MFO
Locked Out
Locked Out
Locked Out
Not Isolated
Not Isolated
Not Isolated
Standby Mode
VBB l VCC
Locked Out
Locked Out
Locked Out
Not Isolated
Not Isolated
Open Drain
The Interrupt Power Fail Operation bit in the Real-Time
Mode Register determines whether or not the interrupts will
continue to function after a power fail event.
As power returns to the system, the battery switch over circuit will switch back to VCC power as soon as it becomes
greater than the battery voltage. The chip will remain in the
locked out state as long as PFAIL e 0. When PFAIL e 1 the
chip is unlocked, but only after another 30 ms min x 63
ms max debounce time. The system designer must ensure
that his system is stable when power has returned.
The power fail circuitry contains active linear circuitry that
draws supply current from VCC. In some cases this may be
undesirable, so this circuit can be disabled by masking the
power fail interrupt. The power fail input can perform all
lock-out functions previously mentioned, except that no ex-
TL/F/9981 – 11
FIGURE 6. System-Battery Switchover (Upper Left), Power Fail
and Lock-Out Circuits (Lower Right)
9
Functional Description (Continued)
ternal interrupt will be issued. Note that the linear power fail
circuitry is switched off automatically when using VBB in
standby mode.
TABLE III. Register/Counter/RAM
Addressing for DP8573A
A0-4
INITIAL POWER ON DETECT AND
POWER FAIL TIME SAVE
There are two other functions provided on the DP8573A to
ease power supply control. These are an initial Power On
detect circuit, which also can be used as a time keeping
failure detect, and a time save on power failure.
On initial power up the Oscillator Fail Flag will be set to a
one and the real time clock start bit reset to a zero. This
indicates that an oscillator fail event has occurred, and time
keeping has failed.
The Oscillator Fail flag will not be reset until the real-time
clock is started. This allows the system to discriminate between an initial power-up and recovery from a power failure.
If the battery backed mode is selected, then bit D6 of the
Periodic Flag Register must be written low. This will not affect the contents of the Oscillator Fail Flag.
To relieve CPU overhead for saving time upon power failure,
the Time Save Enable bit is provided to do this automatically. (See also Reading the Clock: Latched Read.) The Time
Save Enable bit, when set, causes the Time Save RAM to
follow the contents of the clock. This bit can be reset by
software, but if set before a power failure occurs, it will automatically be reset when the clock switches to the battery
supply (not when a power failure is detected by the PFAIL
pin). Thus, writing a one to the Time Save bit enables both a
software write or power fail write.
RS
(Note 1)
Description
CONTROL REGISTERS
00
01
02
03
04
01
02
03
04
X
0
0
0
0
1
1
1
1
Main Status Register
N/A
N/A
Periodic Flag Register
Time Save Control Register
Real Time Mode Register
Output Mode Register
Interrupt Control Register 0
Interrupt Control Register 1
COUNTERS (CLOCK CALENDAR)
SINGLE POWER SUPPLY APPLICATIONS
The DP8573A can be used in a single power supply application. To achieve this, the VBB pin must be connected to
ground, and the power connected to VCC. The Oscillator
Failed/Single Supply bit in the Periodic Flag Register should
be set to a logic 1, which will disable the oscillator battery
reference circuit. The power fail interrupt should also be disabled. This will turn off the linear power fail detection circuits, and will eliminate any quiescent power drawn through
these circuits.
05
06
07
08
09
0A
0B
0C
0D
0E
X
X
X
X
X
X
X
X
X
X
1/100, 1/10 Seconds
Seconds
Minutes
Hours
Days of Month
Months
Years
RAM
D0, D1 bits only
Day of Week
0F
10
11
12
X
X
X
X
N/A
N/A
N/A
N/A
(0 – 99)
(0 – 59)
(0 – 59)
(1 – 12, 0 – 23)
(1 – 28/29/30/31)
(1 – 12)
(0 – 99)
(1 – 7)
TIME COMPARE RAM
13
14
15
16
17
18
DETAILED REGISTER DESCRIPTION
There are 5 external address bits: Thus, the host microprocessor has access to 28 locations at one time. An internal
switching scheme provides a total of 30 locations.
The only register that does not get switched is the Main
Status Register. It contains the register select bit as well as
status information.
A memory map is shown in Figure 2 and register addressing
in Table III. They show the name, address and page locations for the DP8573A.
X
X
X
X
X
X
Sec Compare RAM
Min Compare RAM
Hours Compare RAM
DOM Compare RAM
Months Compare RAM
DOW Compare RAM
(0 – 59)
(0 – 59)
(1 – 12, 0 – 23)
(1 – 28/29/30/31)
(1 – 12)
(1 – 7)
TIME SAVE RAM
19
1A
1B
1C
1D
X
X
X
X
X
Seconds Time Save RAM
Minutes Time Save RAM
Hours Time Save RAM
Day of Month Time Save RAM
Months Time Save RAM
1E
1F
1
X
RAM
RAM/Test Mode Register
Note 1: RSÐRegister Select (Bit D6 of Main Status Register)
10
Functional Description (Continued)
backed mode. Bit D6 is automatically set to 1 on initial power-up or an oscillator fail event. The oscillator fail flag is
reset by writing a one to the clock start/stop bit in the Real
Time Mode Register, with the crystal oscillating.
When D6 is written to, it defines whether the TCP is being
used in battery backed (normal) or in a single supply mode
application. When set to a one this bit configures the TCP
for single power supply applications. This bit is automatically
set on initial power-up or an oscillator fail event. When set,
D6 disables the oscillator reference circuit. The result is that
the oscillator is referenced to VCC. When a zero is written to
D6 the oscillator reference is enabled, thus the oscillator is
referenced to VBB. This allows operation in standard battery
standby applications.
At initial power on, if the DP8573A is going to be programmed for battery backed mode, the VBB pin should be
connected to a potential in the range of 2.2V to VCC b
0.4V.
For single supply mode operation, the VBB pin should be
connected to GND and the PFAIL pin connected to VCC.
D7: Writing a one to this bit enables the test mode register
at location 1F (see Table III). This bit should be forced to
zero during initialization for normal operation. If the test
mode has been entered, clear the test mode register before
leaving test mode. (See separate test mode application
note for further details.)
MAIN STATUS REGISTER
TL/F/9981 – 12
The Main Status Register is always located at address 0
regardless of the register block selected.
D0: This read only bit is a general interrupt status bit that is
taken directly from the interrupt pins. The bit is a one when
an interrupt is pending on either the INTR pin or the MFO
pin (when configured as an interrupt). This is unlike D3
which can be set by an internal event but may not cause an
interrupt. This bit is reset when the interrupt status bits in the
Main Status Register are cleared.
D1 – D3: These three bits of the Main Status Register are the
main interrupt status bits. Any bit may be a one when any of
the interrupts are pending. Once an interrupt is asserted the
mP will read this register to determine the cause. These
interrupt status bits are not reset when read. Except for D1,
to reset an interrupt a one is written back to the corresponding bit that is being tested. D1 is reset whenever the PFAIL
pin e logic 1. This prevents loss of interrupt status when
reading the register in a polled mode. D1 and D3 are set
regardless of whether these interrupts are masked or not by
bits D6 and D7 of Interrupt Control Registers 0 and 1.
D4, D5 and D7: General purpose RAM bits.
D6: Bit D6 controls the register block to be accessed (see
memory map).
TIME SAVE CONTROL REGISTER
PERIODIC FLAG REGISTER
TL/F/9981 – 14
D0 – D5: General purpose RAM bits.
D6: Not Available, appears as logic 0 when read.
D7: Time Save Enable bit controls the loading of real-timeclock data into the Time Save RAM. When a one is written
to this bit the Time Save RAM will follow the corresponding
clock registers, and when a zero is written to this bit the time
in the Time Save RAM is frozen. This eliminates any synchronization problems when reading the clock, thus negating the need to check for a counter rollover during a read
cycle.
This bit must be set to a one prior to power failing to enable
the Time Save feature. When the power fails this bit is automatically reset and the time is saved in the Time Save RAM.
TL/F/9981 – 13
The Periodic Flag Register has the same bit for bit correspondence as Interrupt Control Register 0 except for D6
and D7. For normal operation (i.e., not a single supply application) this register must be written to on initial power up or
after an oscillator fail event. D0–D5 are read only bits, D6
and D7 are read/write.
D0 – D5: These bits are set by the real time rollover events:
(Time Change e 1). The bits are reset when the register is
read and can be used as selective data change flags.
D6: This bit performs a dual function. When this bit is read, a
one indicates that an oscillator failure has occurred and the
time information may have been lost. Some of the ways an
oscillator failure might be caused are: failure of the crystal,
shorting OSC IN or OSC OUT to GND or VCC, removal of
crystal, removal of battery when in the battery backed mode
(when a ‘‘0’’ is written to D6), lowering the voltage at the
VBB pin to a value less than 2.2V when in the battery
REAL TIME MODE REGISTER
TL/F/9981 – 15
11
Functional Description (Continued)
D0 – D1: These are the leap year counter bits. These bits are
written to set the number of years from the previous leap
year. The leap year counter increments on December 31st
and it internally enables the February 29th counter state.
This method of setting the leap year allows leap year to
occur whenever the user wishes to, thus providing flexibility
in implementing Japanese leap year function.
LY1
LY0
Leap Year
Counter
0
0
1
1
0
1
0
1
Leap Year Current Year
Leap Year Last Year
Leap Year 2 Years Ago
Leap Year 3 Years Ago
INTERRUPT CONTROL REGISTER 0
TL/F/9981 – 17
D0 – D5: These bits are used to enable one of the selected
periodic interrupts by writing a one into the appropriate bit.
These interrupts are issued at the rollover of the clock. For
example, the minutes interrupt will be issued whenever the
minutes counter increments. In all likelihood the interrupt
will be enabled asynchronously with the real time change.
Therefore, the very first interrupt will occur in less than the
periodic time chosen, but after the first interrupt all subsequent interrupts will be spaced correctly. These interrupts
are useful when minute, second, real time reading, or task
switching is required. When all six bits are written to a 0 this
disables periodic interrupts from the Main Status Register
and the interrupt pin. If battery backed mode is selected and
the DP8573A is in standby (VBB l VCC), then these bits are
controlled by D4 of the Real Time Mode Register.
D6 and D7: General purpose RAM.
D2: The count mode for the hours counter can be set to
either 24 hour mode or 12 hour mode with AM/PM indicator.
A one will place the clock in 12 hour mode.
D3: This bit is the master Start/Stop bit for the clock. When
a one is written to this bit the real time counter’s prescaler
and counter chain are enabled. When this bit is reset to zero
the contents of the real time counter is stopped. When the
RTC is initially powered up this bit will be held at a logic 0
until the oscillator starts functioning correctly after which
this bit may be modified. If an oscillator fail event occurs,
this bit will be reset to logic 0.
D4: This bit controls the operation of the interrupt output in
standby mode. If set to a one it allows Alarm, Periodic, and
Power Fail interrupts to be functional in standby mode. Note
that the MFO pin is configured as open drain in standby
mode.
If bit D4 is set to a zero then bits D0–D5 of Interrupt Control
Register 0 and bits D6 and D7 of Interrupt Control Register
1 will be reset when the RTC enters the standby mode.
They will have to be re-configured when system (VCC) power is restored.
D5 – D7: General purpose RAM bits.
INTERRUPT CONTROL REGISTER 1
OUTPUT MODE REGISTER
TL/F/9981 – 18
D0 – D5: Each of these bits are enable bits which will enable
a comparison between an individual clock counter and its
associated compare RAM. If any bit is a zero then that
clock-RAM comparator is set to the ‘‘always equal’’ state
and the associated TIME COMPARE RAM byte can be used
as general purpose RAM. However, to ensure that an alarm
interrupt is not generated at bit D3 of the Main Status Register, all bits must be written to a logic zero.
D6: In order to generate an external alarm compare interrupt to the mP from bit D3 of the Main Status Register, this
bit must be written to a logic 1. If battery backed mode is
selected and the DP8573A is in standby (VBB l VCC), then
this bit is controlled by D4 of the Real Time Mode Register.
D7: The MSB of this register is the enable bit for the Power
Fail Interrupt. When this bit is set to a one an interrupt will
be generated to the mP when VBB l VCC. If battery backed
mode is selected and the DP8573A is in standby (VBB l
VCC), then this bit is controlled by D4 of the Real Time
Mode Register.
TL/F/9981–16
D0 – D6: General purpose RAM bits.
D7: This bit is used to program the signal appearing at the
MFO output, as follows:
D7
MFO Output Signal
0
1
Power Fail Interrupt
Buffered Crystal Oscillator
12
Control and Status Register Address Bit Map
D7
D6
Main Status Register PS e X
R/W
R/W
RAM
Register
Select
D5
RS e X
R/W
RAM
Periodic Flag Register PS e 0
R/W
R/W4
Test
Mode
Osc. Fail/
Single Supply
N/A
RS e 0
RAM
1 ms
Flag
10 ms
Flag
MFO as
Crystal
RAM
RAM
RAM
Alarm
Interrupt
Enable
D0
R/W1
R2
R3
Periodic
Interrupt
Power Fail
Interrupt
Interrupt
Status
R5
R5
R5
Seconds
Flag
10 Second
Flag
Minute
Flag
RAM
RAM
RAM
All Bits R/W
12/24 Hr.
Mode
Leap Year
MSB
Leap Year
LSB
All Bits R/W
RAM
RAM
RAM
RAM
All Bits R/W
1 ms
Interrupt
Enable
Seconds
Interrupt
Enable
10 Second
Interrupt
Enable
Minute
Interrupt
Enable
All Bits R/W
DOW
Interrupt
Enable
Minute
Interrupt
Enable
Second
Interrupt
Enable
All Bits R/W
RAM
1. Reset by
writing
1 to bit.
2. Set/reset by
voltage at
PFAIL pin.
3. Reset when
all pending
interrupts
are removed.
4. Read Osc fail
Write 0 BattBacked Mode
Write 1 Single
Supply Mode
5. Reset by
positive edge
of read.
Address e 01H
Interrupt EN
on Back-Up
RS e 1
Interrupt Control Register 1 PS e 0
Power Fail
Interrupt
Enable
100 ms
Flag
RAM
RS e 1
Interrupt Control Register 0 PS e 0
RAM
D1
RS e 0 Address e 04H
RAM
Output Mode Register PS e 0
D2
Address e 03H
R5
R5
Real Time Mode Register PS e 0
RAM
Alarm
Interrupt
RAM
R5
Time Save Control Register PS e 0
Time Save
Enable
D4
D3
ADDRESS e 00H
R/W
R/W1
Clock
Start/Stop
Address e 02H
RAM
RS e 1
RAM
Address e 03H
10 ms
Interrupt
Enable
RS e 1
100 ms
Interrupt
Enable
Address e 04H
Month
Interrupt
Enable
DOM
Interrupt
Enable
Hours
Interrupt
Enable
Application Hints
4. Enter a software loop that does the following:
Set a 3 second(approx) software counter. The crystal
oscillator may take 1 second to start.
4.1 Write a 1 to bit D3 in the Real Time Mode Register (try
to start the clock). Under normal operation, this bit can
be set only if the oscillator is running. During the software loop, RAM, real time counters, output configuration, interrupt control and timer functions may be initialized.
Suggested Initialization Procedure for DP8573A in Battery Backed Applications that use the VBB Pin
1. Enter the test mode by writing a 1 to bit D7 in the Periodic Flag Register.
2. Write zero to the RAM/TEST mode Register located in
page 0, address HEX 1F.
3. Leave the test mode by writing a 0 to bit D7 in the Periodic Flag Register. Steps 1, 2, 3 guarantee that if the
test mode had been entered during power on (due to
random pulses from the system), all test mode conditions are cleared. Most important is that the OSC Fail
Disable bit is cleared. Refer to AN-589 for more information on test mode operation.
13
Application Hints (Continued)
The only method to ensure the chip is in the battery
backed mode is to measure the waveform at the OSC
OUT pin. If the battery backed mode was selected successfully, then the peak to peak waveform at OSC OUT
is referenced to the battery voltage. If not in battery
backed mode, the waveform is referenced to VCC. The
measurement should be made with a high impedance
low capacitance probe (10 MX, 10 pF oscilloscope
probe or better). Typical peak to peak swings are within
0.6V of VCC and ground respectively.
7. Write a 1 to bit D7 of Interrupt Control Register 1. This
action enables the PFAIL pin and associated circuitry.
8. Write a 1 to bit D4 of the Real Time Mode Register. This
action ensures that bit D7 of Interrupt Control Register 1
remains a 1 when VBB l VCC (Standby Mode).
9. Initialize the rest of the chip as needed.
5. Test bit D6 in the Periodic Flag Register:
IF a 1, go to 4.1. If this bit remains a 1 after 3 seconds,
then abort and check hardware. The crystal may be defective or not installed. There may be a short at OSC IN
or OSC OUT to VCC or GND, or to some impedance that
is less than 10 MX.
IF a 0, then the oscillator is running, go to step 7.
6. Write a 0 to bit D6 in the Periodic Flag Register. This
action puts the clock chip in the battery backed mode.
This mode can be entered only if the OSC fail flag (bit
D6 of the Periodic Flag Register) is a 0. Reminder, bit D6
is a dual function bit. When read, D6 returns oscillator
status. When written, D6 causes either the Battery
Backed Mode, or the Single Supply Mode of operation.
Typical Application
TL/F/9981 – 19
*These components may be necessary to meet UL requirements
for lithium batteries. Consult battery manufacturer.
14
Typical Performance Characteristics
Operating Current vs
Supply Voltage
(Single Supply Mode
FOSC e 32.768 kHz)
Operating Current vs
Supply Voltage
(Battery Backed Mode
FOSC e 32.768 kHz)
Standby Current vs Power
Supply Voltage
(FOSC e 32.768 kHz)
TL/F/9981 – 22
TL/F/9981–20
TL/F/9981 – 21
Physical Dimensions inches (millimeters)
Molded Dual-In-Line Package (N)
Order Number DP8573AN
NS Package Number N24C
15
DP8573A Real Time Clock (RTC)
Physical Dimensions inches (millimeters) (Continued)
Plastic Chip Carrier Package (V)
Order Number DP8573AV
NS Package Number V28A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or
systems which, (a) are intended for surgical implant
into the body, or (b) support or sustain life, and whose
failure to perform, when properly used in accordance
with instructions for use provided in the labeling, can
be reasonably expected to result in a significant injury
to the user.
National Semiconductor
Corporation
2900 Semiconductor Drive
P.O. Box 58090
Santa Clara, CA 95052-8090
Tel: 1(800) 272-9959
TWX: (910) 339-9240
National Semiconductor
GmbH
Livry-Gargan-Str. 10
D-82256 F4urstenfeldbruck
Germany
Tel: (81-41) 35-0
Telex: 527649
Fax: (81-41) 35-1
National Semiconductor
Japan Ltd.
Sumitomo Chemical
Engineering Center
Bldg. 7F
1-7-1, Nakase, Mihama-Ku
Chiba-City,
Ciba Prefecture 261
Tel: (043) 299-2300
Fax: (043) 299-2500
2. A critical component is any component of a life
support device or system whose failure to perform can
be reasonably expected to cause the failure of the life
support device or system, or to affect its safety or
effectiveness.
National Semiconductor
Hong Kong Ltd.
13th Floor, Straight Block,
Ocean Centre, 5 Canton Rd.
Tsimshatsui, Kowloon
Hong Kong
Tel: (852) 2737-1600
Fax: (852) 2736-9960
National Semiconductores
Do Brazil Ltda.
Rue Deputado Lacorda Franco
120-3A
Sao Paulo-SP
Brazil 05418-000
Tel: (55-11) 212-5066
Telex: 391-1131931 NSBR BR
Fax: (55-11) 212-1181
National Semiconductor
(Australia) Pty, Ltd.
Building 16
Business Park Drive
Monash Business Park
Nottinghill, Melbourne
Victoria 3168 Australia
Tel: (3) 558-9999
Fax: (3) 558-9998
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Audio
www.ti.com/audio
Communications and Telecom www.ti.com/communications
Amplifiers
amplifier.ti.com
Computers and Peripherals
www.ti.com/computers
Data Converters
dataconverter.ti.com
Consumer Electronics
www.ti.com/consumer-apps
DLP® Products
www.dlp.com
Energy and Lighting
www.ti.com/energy
DSP
dsp.ti.com
Industrial
www.ti.com/industrial
Clocks and Timers
www.ti.com/clocks
Medical
www.ti.com/medical
Interface
interface.ti.com
Security
www.ti.com/security
Logic
logic.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Power Mgmt
power.ti.com
Transportation and Automotive www.ti.com/automotive
Microcontrollers
microcontroller.ti.com
Video and Imaging
RFID
www.ti-rfid.com
OMAP Mobile Processors
www.ti.com/omap
Wireless Connectivity
www.ti.com/wirelessconnectivity
TI E2E Community Home Page
www.ti.com/video
e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated