Back to Selector Page F64G Olympian Plus General Purpose Filter 1/4", 3/8", 1/2", 3/4" Port Sizes ● Olympian Plus plug in design ● High efficiency water and particle removal ● Quick release bayonet bowl ● High visibility prismatic sight glass* ● Optional service indicator * UK and other patents pending Technical Data Fluid: Compressed air Maximum pressure: Guarded transparent bowl: 10 bar (150 psig) Metal bowl: 17 bar (250 psig) Operating temperature*: Guarded transparent bowl: -20° to +50°C (0° to +125°F) Metal bowl: -20° to +80°C (0° to +175°F) * Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Partical removal: 5 µm, 25 µm or 40 µm. Within ISO 8573-1, Class 3 and Class 5 Typical flow at 6,3 bar (90 psig) inlet pressure and 0,5 bar (7 psig) pressure drop: 5 µm element: 55 dm3/s (116 scfm) 40 µm element: 70 dm3/s (148 scfm) Automatic drain connection: 1/8" Automatic drain operating conditions: Minimum pressure: 0,7 bar (10 psig). Drain opens when bowl pressure drops below 0,2 bar (3 psig). Minimum air flow: 1 dm3/s (2 scfm) required to close drain. Nominal bowl size: 0,2 litre (7 fluid ounce) Materials: Body: Zinc Yoke: Zinc Metal bowl: Aluminium Standard metal bowl prismatic liquid level indicator lens: Grilamid Optional metal bowl sight glass: Pyrex Optional transparent bowl: Polycarbonate Element: Sintered plastic Elastomers: Synthetic rubber Optional service life indicator: Body: Transparent nylon. Internal parts: Acetal Spring: Stainless steel Elastomers: Nitrile Ordering Information See Ordering Information on the following pages. ISO Symbols Automatic Drain 7/97 Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. Manual Drain N/AL.8.240.100.01 F64G Typical Performance Characteristics bar g psig FLOW CHARACTERISTICS PORT SIZE: 1/2" 40 µm ELEMENT 0,8 INLET PRESSURE - bar g (psig) PRESSURE DROP 1 2,5 (36) 0,6 4,0 (58) 6,3 (91) 8,0 10,0 (116) (150) 8 6 0,4 4 0,2 2 0 0 0 0 20 40 40 80 60 120 80 100 160 200 dm3/s 240 scfm AIR FLOW Ordering Information. Models listed include ISO G threads, automatic drain, metal bowl, 40 µm element. Models do not include the service life indicator. Port Size G1/4 G3/8 G1/2 G3/4 Model F64G-2GN-AD3 F64G-3GN-AD3 F64G-4GN-AD3 F64G-6GN-AD3 Flow† dm3/s (scfm) 33 (70) 66 (140) 70 (148) N.A. Weight kg (lb) 1,42 (3.13) 1,42 (3.13) 1,32 (2.91) 1,72 (3.79) † Typical flow with a 40 µm element at 6,3 bar (90 psig) inlet pressure and a 0,5 bar (7 psig) pressure drop. For replacement Filter (without yoke) substitute ‘N’ at the 5th and 6th digits eg: F64G-NNN-AD3. Alternative Models F 6 4 G - ★ ★ ★ - ★★ ★ Port Size 1/4" 3/8" 1/2" 3/4" Substitute 2 3 4 6 Element 5 µm 25 µm 40 µm Substitute 1 2 3 Threads PTF ISO Rc taper ISO G parallel Substitute A B G Bowl Metal with liquid level indicator Transparent with guard Closed bowl* Substitute D P E Service Life Indicator With Without Substitute D N Drain Manual Auto drain Substitute M A * For vacuum use. Accessories Wall Mounting Bracket Service Indicator 74504-50 Factory fit option only See alternative models table N/AL.8.240.100.02 Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. 7/97 F64G Dimensions mm (inches) 208 (8.19)† 224 (8.82)† 201 (7.91)† 217 (8.54)† 37 (1.46)† 74 (2.91) 37 (1.46) 105 (4.13)* † Minimum clearance required to remove bowl. * 157 mm (6.18") for G3/4 models Bracket Mounting Bracket Kit Reference Use 8 mm (5/16") screws to mount bracket to wall. Part Number 74504-50 93 (3.66) 114 (4.49) 11 (0.43) 110 (4.33) 8,2 (0.32) 143 (5.63) 30,5 (1.20) 85 (3.35) 48 (1.89) Item Wall Bracket 14,5 (0.57) Service Kits Item Service kit Elements Type Seal and gasket 5 µm 25 µm 40 µm Service Life Indicator Liquid level lens kit Replacement drains Prismatic Pyrex Automatic Manual Part Number 4380-200 4338-01 4338-99 4338-02 5797-50 4380-040 4380-041 3000-97 684-84 Service kit includes port seals, louvre o-ring, bowl o-ring and drain gasket. 7/97 Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. N/AL.8.240.100.03 F64G Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Water vapor will pass through these units and will condense into liquid if air temperature drops in the downstream system. Install an air dryer if water condensation could have a detrimental effect on the application. N/SH.8.240.100.04 Issue No.1 Revision 0 Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. 7/97