LG T676
TOPLED, SMT LED with integrated reflector. With our
great experience in SMT LED we are able to offer a
high quality product for all kind of applications.
TOPLED, SMT-LED mit integriertem Reflektor. Mit
unserer großen Erfahrung in SMT LED sind wir in der
Lage, ein qualitativ hochwertiges Produkt für alle Arten
von Anwendungen anzubieten.
Features:
•
Package: white PLCC-2 package, colorless clear
resin
•
Viewing angle at 50 % IV: 120° (Lambertian
Emitter)
•
Color: green (570 nm)
•
Corrosion Robustness: Improved corrosion
robustness
Besondere Merkmale:
•
Gehäusetyp: weisses PLCC-2 Gehäuse,
farbloser klarer Verguss
•
Abstrahlwinkel bei 50 % IV: 120° (Lambertscher
Strahler)
•
Farbe: grün (570 nm)
•
Korrosionsstabilität: Verbesserte
Korrosionsstabilität
Applications
•
Optical Indicator
•
Coupling into Light Guides
•
Backlighting
•
Automotive Interior Lighting
•
Dashboard Backlighting
•
Outdoor displays
•
Signal and Symbol Luminary
Anwendungen
•
Optischer Indikator
•
Einkopplung in Lichtleiter
•
Hinterleuchtung
•
Automobilbeleuchtung innen
•
Instrumentenbeleuchtung
•
Informationsanzeigen im Außenbereich
•
Signal- und Symbolleuchten
2015-06-01
1
Version 1.2
LG T676
Ordering Information
Bestellinformation
Type:
Luminous Intensity 1) page 20
Ordering Code
Typ:
Lichtstärke 1) Seite 20
Bestellnummer
IF = 20 mA
IV [mcd]
LG T676-P1Q2-24
45 ... 112
Q65110A2178
LG T676-P2R1-24
56 ... 140
Q65110A4007
Note:
The above Type Numbers represent the order groups which include only a few brightness groups (see page 5). Only one group will
be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LG T676-P2R1-24 means that
only one group P2, Q1, Q2, R1 will be shippable for any packing unit.
In a similar manner for colors where wavelength groups are measured and binned, single wavelength groups will be shipped on any
one packing unit. E. g. LG T676-P2R1-24 means that only one wavelength group 2,3,4 will be shippable. LG T676-P2R1-24 means
that the device will be shipped within the specified limits as stated on page 5.
Anm.:
Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen
(siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LG T676-P2R1-24 bedeutet, dass
in einer Verpackungseinheit nur eine der Helligkeitsgruppen P2, Q1, Q2, R1 enhalten ist.
Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine
Wellenlängengruppe geliefert. Z. B. LG T676-P2R1-24 bedeutet, dass in einer Verpackungseinheit nur eine der
Wellenlängengruppen 2,3,4 enthalten ist (siehe Seite 5). LG T676-P2R1-24 bedeutet, dass das Bauteil innerhalb der spezifizierten
Grenzen geliefert wird.
2015-06-01
2
Version 1.2
LG T676
Maximum Ratings
Grenzwerte
Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
Operating temperature range
Betriebstemperatur
Top
-40 ... 100
°C
Storage temperature range
Lagertemperatur
Tstg
-40 ... 100
°C
Junction temperature
Sperrschichttemperatur
Tj
125
°C
Forward current
Durchlassstrom
(TS = 25 °C)
IF
30
mA
Surge current
Stoßstrom
(t ≤ 10 µs; D = 0.005; TS = 25 °C)
IFM
1000
mA
Reverse voltage 2) page 20
Sperrspannung 2) Seite 20
(TS = 25 °C)
VR
12
V
ESD withstand voltage
ESD Festigkeit
(acc. to ANSI/ESDA/JEDEC JS-001 - HBM)
VESD
up to 2
kV
2015-06-01
3
Version 1.2
LG T676
Characteristics (TS = 25 °C; IF = 20 mA)
Kennwerte
Parameter
Symbol
Values
Unit
Bezeichnung
Symbol
Werte
Einheit
Wavelength at peak emission
Wellenlänge d. emittierten Lichtes
(typ.)
λpeak
572
nm
Dominant Wavelength 3) page 20
Dominantwellenlänge 3) Seite 20
(min.)
(typ.)
(max.)
λdom
λdom
λdom
566
570
575
nm
nm
nm
Viewing angle at 50 % IV
Abstrahlwinkel bei 50 % IV
(typ.)
2ϕ
120
°
Forward voltage 4) page 20
Durchlassspannung 4) Seite 20
(min.)
(typ.)
(max.)
VF
VF
VF
1.80
2.00
2.40
V
V
V
Reverse current
Sperrstrom
(VR = 12 V)
(typ.)
(max.)
IR
IR
0.01
10
µA
µA
Temperature coefficient of λpeak
Temperaturkoeffizient von λpeak
(typ.)
TCλpeak
0.12
nm/K
Temperature coefficient of VF
Temperaturkoeffizient von VF
(typ.)
TCV
-2.6
mV/K
Real thermal resistance junction / ambient 5) page 20 ,
(max.)
Rth JA real
500
K/W
(max.)
Rth JS real
280
K/W
6) page 20
Realer Wärmewiderstand Sperrschicht / Umgebung
5) Seite 20 , 6) Seite 20
Real thermal resistance junction / solder point
6) page 20
Realer Wärmewiderstand Sperrschicht / Lötpad
6) Seite 20
2015-06-01
4
Version 1.2
LG T676
Brightness Groups
Helligkeitsgruppen
Group
Luminous Intensity 1) page 20
Luminous Intensity 1) page 20
Luminous Flux 7) page 20
Gruppe
Lichtstärke 1) Seite 20
Lichtstärke 1) Seite 20
Lichtstrom 7) Seite 20
(min.) Iv [mcd]
(max.) Iv [mcd]
(typ.) ΦV [mlm]
P1
45
56
150
P2
56
71
190
Q1
71
90
240
Q2
90
112
305
R1
112
140
380
Dominant Wavelength Groups 3) page 20
Dominant Wellenlängengruppen 3) Seite 20
Group
green
Gruppe
(min.) λdom
[nm]
(max.) λdom
[nm]
2
566
569
3
569
572
4
572
575
Note:
No packing unit / tape ever contains more than one color group for each selection.
Anm.:
In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Farbe enthalten.
2015-06-01
5
Version 1.2
LG T676
Group Name on Label
Gruppenbezeichnung auf Etikett
Example: P2-2
Beispiel: P2-2
Brightness
Helligkeit
Wavelength
Wellenlänge
P2
2
Note:
No packing unit / tape ever contains more than one group for each selection.
Anm.:
In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
2015-06-01
6
Version 1.2
LG T676
Relative Spectral Emission - V(λ) = Standard eye response curve 7) page 20
Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 7) Seite 20
Irel = f (λ); TS = 25 °C; IF = 20 mA
Irel
LG T676
1.0
: Vλ
: green
0.8
0.6
0.4
0.2
0.0
350
400
450
500
550
600
650
700
750
800
λ [nm]
Radiation Characteristics 7) page 20
Abstrahlcharakteristik 7) Seite 20
Irel = f (ϕ); TS = 25 °C
40˚
30˚
20˚
10˚
0˚
ϕ
50˚
OHL01660
1.0
0.8
0.6
60˚
0.4
70˚
0.2
80˚
0
90˚
100˚
1.0
2015-06-01
0.8
0.6
0.4
0˚
20˚
7
40˚
60˚
80˚
100˚
120˚
Version 1.2
LG T676
Forward Current 7) page 20 , 8) page 20
Durchlassstrom 7) Seite 20 , 8) Seite 20
IF = f (VF); TS = 25 °C
Relative Luminous Intensity 7) page 20 , 8) page 20
Relative Lichtstärke 7) Seite 20 , 8) Seite 20
IV/IV(20 mA) = f(IF); TS = 25 °C
OHL00457
10 2
mA
OHL03883
10 1
pure green
green
IV
IF
IV (20 mA)
10 0
10 1
5
10 -1
10 0
5
10 -1
1.4
1.6
1.8
2.0
2.2
10 -2 0
10
V 2.6
Relative Luminous Intensity 7) page 20
Relative Lichtstärke 7) Seite 20
IV/IV(25)°C = f(Tj); IF = 20 mA
OHL00568
I V (25 ˚C)
2.5
2.0
pure-green
green
1.5
1.0
0.5
0
-40 -20
0
20
40
60
˚C 100
Tj
2015-06-01
5
10 1
mA 10 2
IF
VF
I V 3.0
pure green
green
8
Version 1.2
LG T676
Max. Permissible Forward Current
Max. zulässiger Durchlassstrom
IF = f (T)
OHL01031
35
I F mA
30
TS
25
TA
20
15
10
TA temp. ambient
TS temp. solder point
5
0
0
20
40
60
80 ˚C 100
T
Permissible Pulse Handling Capability
Zulässige Impulsbelastbarkeit IF = f(tp)
D: Duty cycle, TA = 25 °C
IF
100
A
5
Permissible Pulse Handling Capability
Zulässige Impulsbelastbarkeit IF = f(tp)
D: Duty cycle, TA = 85 °C
OHL00316
tP
D= T
tP
IF
IF
100
A
5
T
D=
10-1
tP
D= T
tP
IF
T
D=
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10-1
5
5
10-2 -5
10 10-4 10-3 10-2 10-1 10 0 101 s 10 2
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10-2 -5
10 10-4 10-3 10-2 10-1 10 0 101 s 10 2
tp
2015-06-01
OHL01432
tp
9
Version 1.2
LG T676
Package Outline 9) page 20
Maßzeichnung 9) Seite 20
2.1 (0.083)
3.0 (0.118)
2.6 (0.102)
2.3 (0.091)
1.7 (0.067)
0.1 (0.004) (typ.)
3.7 (0.146)
3.3 (0.130) 4˚±1
(2.4) (0.095)
3.4 (0.134)
3.0 (0.118)
2.1 (0.083)
0.9 (0.035)
0.7 (0.028)
A
0.5 (0.020)
Cathode marking
1.1 (0.043)
C
0.18 (0.007)
0.12 (0.005)
0.6 (0.024)
0.4 (0.016)
GPLY6724
Approximate Weight:
34 mg
Gewicht:
34 mg
Mark:
bevelled edge (Cathode)
Markierung:
abgeschrägte Ecke (Kathode)
Corrosion robustness:
Test conditions: 40 °C / 90 % rh / 15 ppm H2S /
336 h
= Stricter than IEC 60068-2-43 (H2S) [25°C / 75 %
rh / 10 ppm H2S / 21 days]
= Regarding relevant gas (H2S) stricter than EN
60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb
SO2, 200 ppb NO2,10 ppb Cl2 / 21 days]
Korrosionsfestigkeit:
Test Kondition: 40°C / 90 % rh / 15 ppm H2S / 336
h
= Besser als IEC 60068-2-43 (H2S) [25°C / 75 %
rh / 10 ppm H2S / 21 Tage]
= Bezogen auf das Gas (H2S) besser als EN
60068-2-60 (method 4) [25°C / 75 % rh / 200ppb
SO2, 200ppb NO2,10ppb Cl2 / 21 Tage]
2015-06-01
10
Version 1.2
LG T676
Recommended Solder Pad 9) page 20
Empfohlenes Lötpaddesign 9) Seite 20
Reflow soldering
Reflow-Löten
4.5 (0.177)
1.5 (0.059)
1.5 (0.059)
4.5 (0.177)
2.6 (0.102)
2.6 (0.102)
Padgeometrie für
verbesserte Wärmeableitung
Lötstopplack
Solder resist
Paddesign for
improved heat dissipation
Cu-Fläche > 16 mm 2
Cu-area > 16 mm 2
OHLPY970
9) page 20
Recommended Solder Pad
Empfohlenes Lötpaddesign 9) Seite 20
Reflow soldering
Reflow-Löten
Fläche darf bei Verwendung von TOPLED®
elektrisch nicht beschaltet werden.
For TOPLED® assembly do not use
this area for electrical contact
Padgeometrie für
verbesserte Wärmeableitung
Paddesign for
improved heat dissipation
3.3 (0.130)
3.3 (0.130)
Anode
2.3 (0.091)
11.1 (0.437)
1.5 (0.059)
1.1 (0.043)
3.7 (0.146)
0.8 (0.031)
0.7 (0.028)
Kathode/
Cathode
Fläche darf bei Verwendung von TOPLED®
elektrisch nicht beschaltet werden.
Cu Fläche / <_ 16 mm 2 per pad
Cu-area
For TOPLED® assembly do not use
this area for electrical contact
Lötstoplack
Solder resist
2015-06-01
11
OHLPY440
Version 1.2
LG T676
Note:
For superior solder joint connectivity results we
recommend soldering under standard nitrogen
atmosphere.
Package not suitable for ultra sonic cleaning.
Anm.:
Um eine verbesserte Lötstellenkontaktierung zu
erreichen, empfehlen wir, unter StandardStickstoffatmosphäre zu löten.
Das Gehäuse ist für Ultraschallreinigung nicht
geeignet.
2015-06-01
12
Version 1.2
LG T676
Reflow Soldering Profile
Reflow-Lötprofil
Product complies to MSL Level 2 acc. to JEDEC J-STD-020D.01
OHA04525
300
˚C
T 250
Tp 245 ˚C
240 ˚C
tP
217 ˚C
200
tL
150
tS
100
50
25 ˚C
0
0
50
100
150
200
s 300
250
t
OHA04612
Symbol
Symbol
Profile Feature
Profil-Charakteristik
Pb-Free (SnAgCu) Assembly
Minimum
)
Ramp-up rate to preheat*
25 °C to 150 °C
Time tS
TSmin to TSmax
tS
60
Ramp-up rate to peak*)
TSmax to TP
Recommendation
Maximum
2
3
100
120
2
3
Unit
Einheit
K/s
s
K/s
Liquidus temperature
TL
217
Time above liquidus temperature
tL
80
100
s
Peak temperature
TP
245
260
°C
Time within 5 °C of the specified peak
temperature TP - 5 K
tP
20
30
s
3
6
K/s
10
Ramp-down rate*
TP to 100 °C
480
Time
25 °C to TP
All temperatures refer to the center of the package, measured on the top of the component
* slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
2015-06-01
°C
13
s
Version 1.2
LG T676
Taping 9) page 20
Gurtung 9) Seite 20
2015-06-01
14
Version 1.2
LG T676
Tape and Reel
Gurtverpackung
8 mm tape with 2000 pcs. on ∅ 180 mm reel, 8000 pcs. on ∅ 330 mm reel
W1
D0
P0
A
N
F
W
E
13.0 ±0.25
P2
Label
P1
Direction of unreeling
Direction of unreeling
W2
Leader: min. 400 mm *
Trailer: min. 160 mm *
*) Dimensions acc. to IEC 60286-3; EIA 481-D
OHAY0324
Tape dimensions [mm]
Gurtmaße [mm]
Tape dim ensions in m m
W
P0
P1
P2
D0
E
F
8 + 0.3 / -0.1
4 ± 0.1
2 ± 0.05
or
4 ± 0.1
2 ± 0.05
1.5 ± 0.1
1.75 ± 0.1
3.5 ± 0.05
Reel dimensions [mm]
Rollenmaße [mm]
Reel dim ensions in m m
A
W
Nmin
W1
W2max
180
8
60
8.4 + 2
14.4
A
W
Nmin
W1
W2max
330
8
60
8.4 + 2
14.4
Reel dim ensions in m m
2015-06-01
15
Version 1.2
LG T676
Barcode-Product-Label (BPL)
Barcode-Produkt-Etikett (BPL)
OSRAM Opto
EX
A
RoHS Compliant
(6P) BATCH NO: 1234567890
(1T) LOT NO: 1234567890
BIN1: XX-XX-X-XXX-X
LX XXXX
Semiconductors
MP
(9D) D/C: 1234
ML Temp ST
X XXX °C X
Pack: RXX
LE
DEMY
XXX
X_X123_1234.1234 X
(X) PROD NO: 123456789(Q)QTY:
9999
(G) GROUP:
XX-XX-X-X
OHA04563
Dry Packing Process and Materials
Trockenverpackung und Materialien
Moisture-sensitive label or print
L
VE
el
LE
see
.
lab
e
H)
nk,
(R
bla cod
If
y
bar
.
dit
RH
mi
%
hu
e
/60
ve
ed ag
˚C
ati
rar ck
rel
30
s VE RS
_
<
inf pa
%
ainITI TO
of
to ak
90
urs
d
nt
).
<
ns
(pe
or
urs
d
co NSUC
Ho
de
,
cte
itio
urs
g SEND
Ho
an bje ing
co
˚C
72
nd
Ho urs
5
baRE CO
te
48
˚C su ss
e
Ho
co
±
ce
is
24 6
da
e
y
MI
40 be
tim
˚C
e
ThISTU
th
<
tor
ll pro
tim
SE
or
).
23
tim e
at t wi nt˚C
or
l wi
fac
MO
Flo
tim
s
TO
at
or
ca
at
re.
Flo
d
tha ale el
or
nth
OP
nti
Flo
uiv
du
if: rea
es
l 4 5
Flo
lab
mo
ide
ce
eq
low
g,
l
ve
vic
is
be
or
de
24
tin en
l 5a6
pro
ve
Le
de ,
e
te
co
,
g:
ve l
un wh
Le
ke
r
se
da
ve
%
ure
ba ed low ba
Le
mo
ba
e
al
d
ure
Le
ist
en ref e
e 10
tim
ure
se
for
ist
ale op se
for >
,
Mo
se
3
ist ure
is
or .
,
is ha
se
Mo
nk
be
ist
nk
rd
g
-03
Mo
in
n Flo
r-p
RH g,
bla
Mo
ba
TD
po If blathi
%
kin Ca
life s
(if
ar
t.
wi
10 ba tor
J-S
thi, va p.
elf
Ye ar ks
_
<
e icat me , C
1
Ye ee urs
Sh terlow tem ted at
ed
uir
>
1
W Ho
un
Af
Indno uir DE
1.
d
e
4 8
ref dy
reqy is
2.
JE
bo
e
Mo ore
tim
16
req
:
C/
e
es dit2b
a)
St
tim
or
mi
IP
ed
or g is
tim e
vic
b)
or
e
Hu
Flo
en
tim
or
De
2a kin nc
te
Flo
a)
op
or
3.
b) baere
Flo
da
e
l 1 2
Flo
If
al
ref
tim ve
l
4.
se
d
l 2a3
ve
Le
g
an
ve l
Le
Ba
te
ure
Le ve
ure
Le
ist
Da
ure
ist
Mo
ist ure
Mo
ist
Mo
Mo
Barcode label
N
TIO
U
A
C
M
RA
OS
Humidity indicator
Barcode label
Please check the HIC immidiately after
bag opening.
Discard if circles overrun.
Avoid metal contact.
Do not eat.
Comparator
check dot
WET
If wet,
examine units, if necessary
bake units
15%
If wet,
examine units, if necessary
bake units
10%
5%
If wet,
parts still adequately dry.
change desiccant
Humidity Indicator
MIL-I-8835
AM
OSR
Desiccant
OHA00539
Note:
Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card.
Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry
Pack”. Here you will also find the normative references like JEDEC.
Anm.:
Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte.
Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung”
unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten.
2015-06-01
16
Version 1.2
LG T676
Transportation Packing and Materials
Kartonverpackung und Materialien
Barcode label
8
Y
M
DE
R
18
-1
Q
P
-1
+
P:
C:
99
D/
21
00
(9
D)
21
:
20
00
:
14
2
5
(Q
)Q
TY
O
H
12
34
S S
em R
ic AM
on
du O
p
ct to
or
H
NO
s
TC
3G
BA
(6
P)
NO
: 12
11
00
LO
T
(1
T)
NO
:
OD
PR
)
(X
44
(G
)
G
RO
UP
:
P
-1
+
Q
-1
R
18
DE
M
Y
Bi n2 : Pn3 : Q 1: -1 20
M
-2
2 L
0
Te
2a
22 m
3
24 0 p ST
Ad 26 0 C R
C
R0 ditio 0 C R
PA 77 na RT
l TE
CK
VA
XT
R:
M
u L
lt S
iT Y
O T
P 67
L 6
E Bi
D Bi n1
(9
: 20
)Q
TY
00
D)
D/
C:
01
Muster
:
34
:
NO
O
PR
(X
)
Packing
Sealing label
Dimensions of transportation box in mm
Width
Length
Height
Breite
Länge
Höhe
200 ± 5
352 ± 5
195 ± 5
352 ± 5
30 ± 5
33 ± 5
2015-06-01
M
RA
OS
D
5
14 2
110 0
(Q
O
S
TC
(1
T)
LO
T
NO
(6
P)
: 12
BA
S
8
3G
em R
ic AM
o
n O
d
u p
ct to
o
H
rs
NO
2199
H
12
2100
01
44
el
A
C
OU
L
GR
E
V
LE
see
.
lab
e
H)
nk,
cod
(R
bla
r
If
ty
ba
.
idi
RH
m
hu
0%
e
/6
ive d
˚C
re ag
lat
ra ck
re
30
_
<
inf pa
%
k
s
of
to
90
ea
ur
s
d
).
<
ns
(p
or
ur
s
d
Ho
de
,
cteg
itio
ur s
Ho
an bje
co
˚C
72
sin
nd
Ho ur
5
te
48
˚C su es
e
Ho
IC
co
±
is UR
24 6
da
e
M
40 be oc
ry
tim
˚C
e
Th STSE
r
th
<
ll pr
tim
cto
).
r
OI
oo
23
wi nt
tim e
at
l wi
fa
r
M TO
Fl
oo
tim
s
at
at ale ˚C at
e.
ica
Fl
th
oo r
th
ur
el
OP
nt
Fl oo
on es uiv
if: read
ed
l 4 5
Fl
,
lab
m
ide
eq
low
l
oc
ve
vic
is
ingen
be
or
de
24
l 5a6
pr
ve
Le
de
nt wh
e
te
co
, w,
g:
ve l
Le
ke
r
re
ou
se
da
ba ed flo
Le ve
tu
re
m %
ba
e
ba
al
d
Le
r
en re
tu
re
e
re 10
ois
tim
se
fo
tu
re
ale op se
fo >
,
M
r
se
ois
3
is
,
is ha
se
M
ois tu
nk
be
oo .
03
nk
rd
g
M ois
in
r-p
bla
in Fl RH g,
DM
ba
po If blath
%
kin Ca
life is
(if
.
ar
ST
p.
wi
10 baator et
Jelf r th va
Ye ar ks s
m
_
<
m
ed
1
Ye ee ur
d, C
iredic t
Sh te w, te
at
nt
>
1
W Ho
Af flody
qu In no ire DE
1.
e
4 8
ou
re
ed re ty is
qu JE
2.
bo
e
M
or
tim
16
re C/
:
e
es idi 2b
r
a)
St
tim
mor
is IP
ed
r
oo
tim e
vic
b)
g e
r
Hu
Fl
en
oo
tim
De
2a kin nc
te
Fl
oo r
a)
op
3.
b) ba re
Fl oo
da
e
fe
l 1 2
Fl
If
al
re
tim ve
l
4.
se
d
l 2a3
ve
Le
g
an
ve l
Le
re
Ba
te
Le ve
tu
re
Le
tu
Da ois
re
tu re
M
ois
M
ois tu
M ois
M
Nns IVEORS
ai IT
CT
nt
TIO
co NS
DU
g SE
U
ba E ON
(G
)
M
u L
lt S
iT Y
O T67
P
L 6
Muster
E Bi
D Bi n1
Bi n2 : Pn3 : Q- 1: 1- 20
M
20
2 L
Te
2a
22 m
3
24 0 p ST
Ad 26 0 C R
0 C
R0 dit
ion C R
PA 77 al RT
CK
TE
VA
XT
R:
Barcode label
17
OHA02044
Version 1.2
LG T676
Notes
Hinweise
The evaluation of eye safety occurs according to the
standard IEC 62471:2008 ("photobiological safety of
lamps and lamp systems"). Within the risk grouping
system of this CIE standard, the LED specified in this
data sheet fall into the class Exempt group (exposure
time 10000 s). Under real circumstances (for
exposure time, eye pupils, observation distance), it is
assumed that no endangerment to the eye exists
from these devices. As a matter of principle,
however, it should be mentioned that intense light
sources have a high secondary exposure potential
due to their blinding effect. As is also true when
viewing other bright light sources (e.g. headlights),
temporary reduction in visual acuity and afterimages
can occur, leading to irritation, annoyance, visual
impairment, and even accidents, depending on the
situation.
Die Bewertung der Augensicherheit erfolgt nach
dem Standard IEC 62471:2008 ("photobiological
safety of lamps and lamp systems"). Im
Risikogruppensystem dieser CIE- Norm erfüllen die
in diesem Datenblatt angegebenen LEDs folgende
Gruppenanforderung - Exempt group
(Expositionsdauer 10000 s). Unter realen
Umständen (für Expositionsdauer, Augenpupille,
Betrachtungsabstand) geht damit von diesen
Bauelementen keinerlei Augengefährdung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass
intensive Lichtquellen durch ihre Blendwirkung ein
hohes sekundäres Gefahrenpotenzial besitzen.
Nach einem Blick in eine helle Lichtquelle (z.B.
Autoscheinwerfer), kann ein temporär
eingeschränktes Sehvermögen oder auch
Nachbilder zu Irritationen, Belästigungen,
Beeinträchtigungen oder sogar Unfällen führen.
For further application related informations
please visit www.osram-os.com/appnotes
Für weitere applikationsspezifische
Informationen besuchen Sie bitte
www.osram-os.com/appnotes
2015-06-01
18
Version 1.2
LG T676
Disclaimer
Disclaimer
Attention please!
The information describes the type of component and
shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved.
Due to technical requirements components may
contain dangerous substances.
For information on the types in question please contact
our Sales Organization.
If printed or downloaded, please find the latest version
in the Internet.
Packing
Please use the recycling operators known to you. We
can also help you – get in touch with your nearest sales
office.
By agreement we will take packing material back, if it is
sorted. You must bear the costs of transport. For
packing material that is returned to us unsorted or which
we are not obliged to accept, we shall have to invoice
you for any costs incurred.
Components used in life-support devices or
systems must be expressly authorized for such
purpose!
Critical components* may only be used in life-support
devices** or systems with the express written approval
of OSRAM OS.
Bitte beachten!
Lieferbedingungen und Änderungen im Design
vorbehalten. Aufgrund technischer Anforderungen
können die Bauteile Gefahrstoffe enthalten. Für weitere
Informationen zu gewünschten Bauteilen, wenden Sie
sich bitte an unseren Vertrieb. Falls Sie dieses
Datenblatt ausgedruckt oder heruntergeladen haben,
finden Sie die aktuellste Version im Internet.
Verpackung
Benutzen
Sie
bitte
die
Ihnen
bekannten
Recyclingwege. Wenn diese nicht bekannt sein sollten,
wenden Sie sich bitte an das nächstgelegene
Vertriebsbüro. Wir nehmen das Verpackungsmaterial
zurück, falls dies vereinbart wurde und das Material
sortiert ist. Sie tragen die Transportkosten. Für
Verpackungsmaterial,
das unsortiert
an uns
zurückgeschickt wird oder das wir nicht annehmen
müssen, stellen wir Ihnen die anfallenden Kosten in
Rechnung.
Bauteile, die in lebenserhaltenden Apparaten und
Systemen eingesetzt werden, müssen für diese
Zwecke ausdrücklich zugelassen sein!
Kritische Bauteile* dürfen in lebenserhaltenden
Apparaten und Systemen** nur dann eingesetzt
werden, wenn ein schriftliches Einverständnis von
OSRAM OS vorliegt.
*) A critical component is a component used in a
life-support device or system whose failure can
reasonably be expected to cause the failure of that
life-support device or system, or to affect its safety or
the effectiveness of that device or system.
**) Life support devices or systems are intended (a) to
be implanted in the human body, or (b) to support
and/or maintain and sustain human life. If they fail, it is
reasonable to assume that the health and the life of the
user may be endangered.
2015-06-01
*) Ein kritisches Bauteil ist ein Bauteil, das in
lebenserhaltenden
Apparaten
oder
Systemen
eingesetzt wird und dessen Defekt voraussichtlich zu
einer
Fehlfunktion
dieses
lebenserhaltenden
Apparates oder Systems führen wird oder die
Sicherheit oder Effektivität dieses Apparates oder
Systems beeinträchtigt.
**) Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper oder
(b) für die Lebenserhaltung bestimmt. Falls Sie
versagen, kann davon ausgegangen werden, dass die
Gesundheit und das Leben des Patienten in Gefahr ist.
19
Version 1.2
LG T676
Glossary
Glossar
1)
Brightness: Brightness values are measured during
a current pulse of typically 25 ms, with an internal
reproducibility of ± 8 % and an expanded uncertainty
of ± 11 % (acc. to GUM with a coverage factor of
k = 3).
1)
Helligkeit: Helligkeitswerte werden während eines
Strompulses einer typischen Dauer von 25 ms, mit
einer internen Reproduzierbarkeit von ± 8 % und
einer erweiterten Messunsicherheit von ± 11 %
gemessen (gemäß GUM mit Erweiterungsfaktor
k = 3).
2)
Reverse Voltage: Not
designed
for
reverse
operation. Continuous reverse voltage can cause
migration and LED damage.
2)
Sperrspannung: Die
LED
kann
nicht
in
Sperrrichtung betrieben werden. Kontinuierlicher
Rückwärtsbetrieb kann Migration und eine
Beschädigung der LED zur Folge haben.
3)
Wavelength: The wavelength is measured at a
current pulse of typically 25 ms, with an internal
reproducibility of ± 0.5 nm and an expanded
uncertainty of ± 1 nm (acc. to GUM with a coverage
factor of k = 3).
3)
Wellenlänge: Die Wellenläge wird während eines
Strompulses einer typischen Dauer von 25 ms, mit
einer internen Reproduzierbarkeit von ± 0,5 nm und
einer erweiterten Messunsicherheit von ± 1 nm
gemessen (gemäß GUM mit Erweiterungsfaktor
k = 3).
4)
Forward Voltage: The forward voltage is measured
during a current pulse of typically 8 ms, with an
internal reproducibility of ± 0.05 V and an expanded
uncertainty of ± 0.1 V (acc. to GUM with a coverage
factor of k = 3).
4)
Durchlassspannung: Vorwärtsspannungen
werden während eines Strompulses einer typischen
Dauer
von
8 ms,
mit
einer
internen
Reproduzierbarkeit von ± 0,05 V und einer
erweiterten Messunsicherheit von ± 0,1 V gemessen
(gemäß GUM mit Erweiterungsfaktor k = 3).
5)
Thermal Resistance: RthJA results from mounting
on PC board FR 4 (pad size 16mm² per pad)
5)
Wärmewiderstand: RthJA ergibt sich bei Montage
auf PC-Board FR 4 (Padgröße 16mm² je pad)
6)
Thermal Resistance: Rth max is based on statistic
values (6σ).
6)
Wärmewiderstand: Rth
statistischen Werten (6σ).
7)
Typical Values: Due to the special conditions of the
manufacturing processes of LED, the typical data or
calculated correlations of technical parameters can
only reflect statistical figures. These do not
necessarily correspond to the actual parameters of
each single product, which could differ from the
typical data and calculated correlations or the typical
characteristic line. If requested, e.g. because of
technical improvements, these typ. data will be
changed without any further notice.
7)
Typische Werte: Wegen
der
besonderen
Prozessbedingungen bei der Herstellung von LED
können typische oder abgeleitete technische
Parameter nur aufgrund statistischer Werte
wiedergegeben werden. Diese stimmen nicht
notwendigerweise mit den Werten jedes einzelnen
Produktes überein, dessen Werte sich von typischen
und abgeleiteten Werten oder typischen Kennlinien
unterscheiden können. Falls erforderlich, z.B.
aufgrund technischer Verbesserungen, werden
diese typischen Werte ohne weitere Ankündigung
geändert.
8)
Characteristic curve: In the range where the line of
the graph is broken, you must expect higher
differences between single LEDs within one packing
unit.
8)
Kennlinien: Im gestrichelten Bereich der Kennlinien
muss mit erhöhten Abweichungen zwischen
Leuchtdioden innerhalb einer Verpackungseinheit
gerechnet werden.
9)
Tolerance of Measure: Unless otherwise noted in
drawing, tolerances are specified with ±0.1 and
dimensions are specified in mm.
9)
Maßtoleranz: Wenn in der Zeichnung nicht anders
angegeben, gilt eine Toleranz von ±0,1. Maße
werden in mm angegeben.
2015-06-01
20
max
basiert
auf
Version 1.2
LG T676
Published by OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com © All Rights Reserved.
2015-06-01
21
Similar pages