FEATURES ►SIP Package with Industry Standard Pinout ► Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77”x 0.4”x 0.24”) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77”x 0.4”x 0.28”) 15V&24V Models ►Single and Dual Output Models ►I/O-Isolation 1000 VDC ►Operating Temp. Range -40°C to +85°C ►3 Years Product Warranty PRODUCT OVERVIEW The MAU100 series is a range of 1W DC/DC converters in a small SIP Package featuring I/O-isolation of 1000VDC. An excellent efficiency allows an operating temperature range of –40°C to +85°C. These converters offer an economical solution for many applications where a voltage has to be isolated i.e for noise reduction, ground loop elimination, digital interfaces or for board level power distribution. Model Selection Guide Model Number MAU101 MAU102 MAU103 MAU104 MAU105 MAU106 MAU107 MAU108 MAU109 MAU111 MAU112 MAU113 MAU114 MAU115 MAU116 MAU117 MAU118 MAU119 MAU151 MAU152 MAU153 MAU154 MAU155 MAU156 MAU121 MAU122 MAU123 MAU124 MAU125 MAU126 MAU127 MAU128 MAU129 Input Voltage (Range) VDC 5 (4.5 ~ 5.5) 12 (10.8 ~ 13.2) 15 (13.5 ~ 16.5) 24 (21.6 ~ 26.4) Output Voltage VDC 3.3 5 9 12 15 ±5 ±9 ±12 ±15 3.3 5 9 12 15 ±5 ±9 ±12 ±15 5 12 15 ±5 ±12 ±15 3.3 5 9 12 15 ±5 ±9 ±12 ±15 In Total Power International, Inc Output Current Max. mA 260 200 110 84 67 ±100 ±56 ±42 ±34 260 200 110 84 67 ±100 ±56 ±42 ±34 200 84 67 ±100 ±42 ±34 260 200 110 84 67 ±100 ±56 ±42 ±34 Min. mA 5 4 2 1.5 1 ±2 ±1 ±0.8 ±0.7 5 4 2 1.5 1 ±2 ±1 ±0.8 ±0.7 4 1.5 1 ±2 ±0.8 ±0.7 5 4 2 1.5 1 ±2 ±1 ±0.8 ±0.7 Input Current @Max. Load mA(typ.) 235 281 260 258 258 278 262 258 258 96 114 106 105 104 113 106 104 105 93 85 85 93 85 85 49 59 54 54 53 58 55 53 53 @No Load mA(typ.) Toll Free: 877-646-0900 30 12 11 7 Load Regulation Max. capacitive Load % (max.) 10 10 8 7 7 10 8 7 7 8 8 5 5 5 8 5 5 5 8 5 5 8 5 5 8 8 5 5 5 8 5 5 5 µF Efficiency (typ.) @Max. Load 220 100# 220 100# 220 100# 220 100# # For each output www.total-power.com % 73 71 76 78 78 72 77 78 79 74 73 78 80 80 74 79 81 81 72 79 79 72 80 80 73 71 76 78 79 72 76 79 80 MAU100 SERIES Total Power International, Inc. Input Specifications Parameter Input Voltage Range Input Surge Voltage (1 sec. max.) Reverse Polarity Input Current Internal Filter Type Internal Power Dissipation Output Specifications Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise Temperature Coefficient Short Circuit Protection DC/DC CONVERTER 1W, SIP-Package Model 5V Input Models 12V Input Models 15V Input Models 24V Input Models 5V Input Models 12V Input Models 15V Input Models 24V Input Models Min. 4.5 10.8 13.5 21.6 -0.7 -0.7 -0.7 -0.7 --- All Models --- Conditions Min. ------- Dual Output, Balanced Loads For Vin Change of 1% Io=20% to 100% max. 20MHz Bandwidth General Specifications Parameter 60 Seconds I/O Isolation Capacitance 100KHz, 1V I/O Isolation Resistance Min. Switching Frequency MTBF (calculated) 5V Input Models 500mA Slow-Blow Type 12V Input Models 200mA Slow-Blow Type Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) 70 Case Temperature 2,000,000 --- --- 100 MΩ pF 120 KHz Hours 24V Input Models 100mA Slow-Blow Type --- +90 ℃ --- Toll Free: 877-646-0900 Unit VDC Unit Free-Air convection Lead Temperature (1.5mm from case for 10Sec.) mV P-P %/℃ Max. -40 --- Cooling Unit % % % Min. -50 Humidity (non condensing) In Total Power International, Inc 100 15V Input Models Storage Temperature Range mW --- 60 150mA Slow-Blow Type Conditions A --- --- --- Natural Convection VDC Max. --- 1000 MIL-HDBK-217F@25℃, Ground Benign Input Fuse Typ. 1000 500 VDC Unit Typ. Max. ±1.0 ±3.0 ±0.1 ±1.0 ±1.2 ±1.5 See Model Selection Guide 50 75 ±0.01 ±0.02 0.5 Second Max. ----- Conditions I/O Isolation Voltage (rated) Typ. Max. 5 5.5 12 13.2 15 16.5 24 26.4 --9 --18 --18 --30 --0.3 Internal Capacitor --450 +85 +125 ℃ ℃ 95 % rel. H 260 ℃ www.total-power.com MAU100 SERIES Total Power International, Inc. DC/DC CONVERTER 1W, SIP-Package Power Derating Curve 100 Output Power (%) Natural Convection 20LFM 80 100LFM 60 200LFM 400LFM 40 20 0 -40 ~ 0 20 40 60 80 100 110 Ambient Temperature C (3.3V, 5V & ±5V} Notes 1 2 3 4 5 6 7 (all other output) Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. Ripple & Noise measurement bandwidth is 0-20MHz. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. All DC/DC converters should be externally fused at the front end for protection. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections Pin 19.5 [0.77] 2.54 5.08 2X2.54 [0.10] [0.20] [2X0.10] 4 5 [0.13] 3.2 0.5 [0.02] 2.4 [0.09] 2 10.2 [0.40] 0.5 [0.02] 1 6 Single Output +Vin Dual Output +Vin -Vin -Vout No Pin +Vout -Vin -Vout Common +Vout T: 6.1mm(0.24 inch) for 5V&12V Input Models T: 7.1mm(0.28 inch) for 15V&24V Input Models 18.5 [0.73] T Bottom View 0.50 [0.02] Physical Characteristics Case Size (5V&12V Input) Case Size (15V&24V Input) Case Material Pin Material Weight (5V&12V Input) Weight (15V&24V Input) 4 5 6 0.25 [0.01] 2 : : 19.5x6.1x10.2mm (0.77x0.24x0.40 inches) 19.5x7.1x10.2mm (0.77x0.28x0.40 inches) : Alloy 42 : : : ►All dimensions in mm (inches) ►Tolerance: X.X±0.25 (X.XX±0.01) 1.3 [0.05] 1 X.XX±0.13 ( X.XXX±0.005) ►Pins ±0.05 (±0.002) Non-Conductive Black Plastic (flammability to UL 94V-0 rated) 2.2g 2.6g In Total Power International, Inc Toll Free: 877-646-0900 www.total-power.com MAU100 SERIES Total Power International, Inc. DC/DC CONVERTER 1W, SIP-Package Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Scope Cout Cout Resistive Load Scope Copper Strip Technical Notes Maximum Capacitive Load The MAU100 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 100µF maximum capacitive load for dual outputs and 220µF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is commended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 2.2µF for the 5V input devices, a 1.0µF for the 12V,15V input devices and a 0.47µF for the 24V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.0µF capacitors at the output. + +Vin DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout Load -Out +Vin DC Power Source - +Out Dual Output DC / DC Com. Converter -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 50mm / 2in 15mm / 0.6in In Total Power International, Inc Air Flow DUT Toll Free: 877-646-0900 www.total-power.com