I1000RU Series Ultra-Miniature 10W Wide 4:1 Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 10W Output Power • 4:1 Input Range • Ultra- Miniature Case • Remote On/Off Control • 1,500 VDC Isolation • >350 kHour MTBF • Standard Pin-Out Parameter Input Voltage Range Start-Up Voltage Under Voltage Shutdown Input Filter Conditions Min. Typ. Max. 24 VDC Input 9.0 24.0 36.0 48 VDC Input 18.0 48.0 75.0 24 VDC Input 9.0 48 VDC Input 18.0 24 VDC Input 8.5 48 VDC Input 17.0 (Pi) Filter, Meets EN55022 Class A Units Conditions Units % % % % VDC VDC VDC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Min. Dual Output , Balanced Loads Vin = Min to Max Iout = 15% to 100% Ripple & Noise (20 MHz), See Note 1 Transient Recovery Time, See Note 2 Transient Response Deviation Output Power Protection Temperature Coefficient Output Short Circuit Typ. ±1.0 ±1.0 ±0.3 ±0.5 60 Over Line, Load & Temperature 300 ±3.0 110 150 ±0.01 Continuous (Autorecovery) 25% Load Step Change Max. ±2.0 ±2.0 ±1.0 ±1.2 100 150 600 ±6.0 ±0.02 mV P - P µSec % % %/ºC General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,500 1,000 Typ. Max. Units VDC M pF kHz Max. +80 +100 +125 Units ºC ºC ºC 95 % 1,500 450 Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Derating Humidity Physical Case Size Case Material Weight Conditions Ambient Case Min. -40 Typ. +25 -50 Free Air Convection See Curve RH, Non-condensing 1.00 x 1.00 x 0.40 Inches (25.4 x 25.4 x 10.16 mm) Six-Sided Shielded Aluminum With Non-Conductive Base (UL94-V0) 0.52 Oz (15g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. 350 Typ. Max. Units kHours Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec Min. -0.7 -0.7 Typ. Max. 50.0 100.0 260 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC www.micropowerdirect.com Model Selection Guide Input Model Number I1001RU I1002RU I1003RU I1004RU I1005RU I1006RU I1007RU I1011RU I1012RU I1013RU I1014RU I1015RU I1016RU I1017RU Voltage (VDC) Nominal Range 24 24 24 24 24 24 24 48 48 48 48 48 48 48 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 9.0 - 36.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 Output Current (mA) Full-Load No-Load 352 496 483 474 496 477 474 180 248 241 237 248 238 237 30 30 30 30 30 30 30 20 20 20 20 20 20 20 Voltage Current Current (VDC) (mA, Max) (mA, Min) 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 2,200 2,000 830 660 ±1,000 ±410 ±330 2,200 2,000 830 660 ±1,000 ±410 ±330 Notes: 1. Output ripple is measured with a 0.47 µF ceramic capcitor connected across the outputs. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage the unit, but they may not Min Max meet all specifications. 2.5 VDC 50 VDC 4. The On/Off Control input (Pin 3) is referenced to -Vin (Pin 2). If it is On not used, the control pin should be left open. If the pin is shorted to Off 0.0 VDC 1.0 VDC -VIN, the unit will turn off. In. Current (on) 0.5 mA 6. It is recommended that a fuse be used on the input of a power In. Current (off) -0.5 mA supply for protection. See the Model Selection table above for the correct rating. Efficiency (%, Typ) 330 300 125 100 ±150 ±61 ±50 330 300 125 100 ±150 ±61 ±50 Capacitive Fuse Rating Load Slow-Blow 86 84 86 87 84 86 87 85 84 86 87 84 86 87 (µF Max) (mA) 560 560 150 150 ±220 ±100 ±100 560 560 150 150 ±220 ±100 ±100 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500 Pin Connections Pin 1 2 3 Single Dual +Vin +Vin -Vin -Vin Remote ON/OFF Pin Single Dual 4 5 6 +Vout No Pin -Vout +Vout Common -Vout Mechanical Dimensions Derating Curve - Without HeatSink Mechanical Dimensions - With HeatSink Derating Curve - With HeatSink Notes: MicroPower Direct • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]